{"spec": "NAVAIR 941AS100", "model no.": "T17-1FH", "cap": [{"value": "17", "unit": "ton"}], "hyd fluid": "MIL-PRF-83282", "stock no.": "1730-00-781-9711", "contract no.": "N0038301CP125", "fscm": "COLUMBUS JACK CORP. 00994"}
{"spec": "Dot peen", "model": "ADP120160", "s/n": "R3246CAFC", "pin": "M3M30-001"}
{"model": "RY-F50", "laser power": [{"value": "50", "unit": "W"}], "working area": [{"value": "300x300", "unit": "mm"}], "marking speed": [{"value": "7000", "unit": "mm/s"}], "marking line width": [{"value": "<0.15", "unit": "mm"}], "laser classification": "Class 4", "work voltage": [{"value": "220", "unit": "V"}], "serial no": "19RY0207DK", "rate power": [{"value": "<1000W", "unit": "W"}], "date": "03.11.2019"}
{"m/n": "13ACF-036-230-05", "s/n": "5808J08896", "factory change": [{"value": "5", "unit": "LBS"}, {"value": "12", "unit": "OZS"}], "design pressure hi": [{"value": "278", "unit": "PSIG"}], "design pressure lo": [{"value": "144", "unit": "PSIG"}], "electrical rating": [{"value": "1", "unit": "PH"}, {"value": "60", "unit": "HZ"}], "nominal volts": "208/230", "nominal volts min": "197", "nominal volts max": "253", "compressor": [{"value": "1", "unit": "PH"}, {"value": "14.4", "unit": "RLA"}, {"value": "77", "unit": "LRA"}], "fan motor": [{"value": "1", "unit": "PH"}, {"value": "1.0", "unit": "FLA"}, {"value": "1/5", "unit": "HP"}], "min. ckt ampacity amperage minimum": "19.1", "max fuse or ckt bkr fusible/coupe circuit (hacr per nec)": "30"}
{"model": "R-2800", "mpg ser no": "FP", "prop rotation hand": "RIGHT", "blower ratios": "7.60 - 1", "impeller diameters": "11''", "contract no.": "W535AC16528", "comp ratio": "6.65 - 1", "m. rod location": "B&13", "valve timing clearance intake": ".143", "valve timing clearance exhaust": ".143", "valve timing clearance i.c.": "76", "valve timing clearance e.o.": "76", "reset cold valve clearance intake": "SEE", "reset cold valve clearance exhaust": "MANUAL", "min. cruising oil press.": [{"value": "60", "unit": "LBS/SQ. IN"}], "spark advance": [{"value": "20", "unit": "B.T.C."}], "firing order": "1-12-5-16-9-2-13-6-17-10-3-14-7-18-11-4-15-8", "manufactured by": "FORD MOTOR CO."}
{"serial no": "202404280005W0210", "laser power/wavelength": [{"value": "100", "unit": "W"}, {"value": "1064", "unit": "cm"}], "consumption power": [{"value": "1000", "unit": "W"}], "model": "BY-100GS", "voltage": [{"value": "110", "unit": "V"}, {"value": "50/60", "unit": "Hz"}], "production": "2024.5.06"}
{"no.": "468863", "type": "MMB", "form": "C", "watts": "50000", "hours": "2", "volts": "220/440-30000", "cycles": "25"}
{"type": "3LT50-440/230-Dyn11-23", "frequency": [{"value": "60", "unit": "Hz"}], "ip": "23", "art. no": "3-020-000815", "order": "2876872 - 1", "built (w-y)": "10 - 2011", "kva": "50", "tot. weight": [{"value": "243", "unit": "Kg"}], "insul cf": "F", "duty": "CONT.", "cooling": "AN", "according to": "IEC-60D7680726", "ambient temp": [{"value": "45", "unit": "C"}]}
{"electrical rating": [{"value": "1", "unit": "PH"}, {"value": "60", "unit": "HZ"}], "nominal volts": "208/230", "nominal volts min": "197", "nominal volts max": "253", "compressor": [{"value": "1", "unit": "PH"}, {"value": "21.2", "unit": "RLA"}, {"value": "20", "unit": "LRA"}], "fan motor": [{"value": "1", "unit": "PH"}, {"value": "2.8", "unit": "FLA"}, {"value": "1/3", "unit": "HP"}], "min. ckt ampacity amperage minimum": "29.3", "max fuse or ckt bkr fusible/coupe circuit (hacr per nec)": "50"}
{"kva": "834", "hz": "60", "ph": "1", "pri": [{"value": "4.71/6.09/7.47MHY", "unit": "V"}, {"value": "138-105", "unit": "AMPS"}], "spec": "9873", "s/n": "21600-7", "type": "CLR", "temp. rise": [{"value": "115", "unit": "C"}]}
{"manufactured by": "CAPACITY OF TEXAS", "vin": "4LMBB2118XL011180", "date": "04/99", "vehicle type": "TRUCK", "model": "TJ5000", "wheelbase": [{"value": "116", "unit": "inches"}]}
{"type": "6-030-732021", "power": [{"value": "12.5", "unit": "KVA"}], "frequency": [{"value": "50/60", "unit": "Hz"}], "input": [{"value": "480", "unit": "V"}, {"value": "15.5", "unit": "A"}], "output": [{"value": "400", "unit": "V"}, {"value": "18.0", "unit": "A"}], "connect": "Dyn11", "enclosure": "TYPE 1", "temp": "F", "class": [{"value": "155", "unit": "C"}], "weight": [{"value": "112", "unit": "kg"}], "date": "Oct, 14"}
{"piston": [{"value": "82", "unit": "ID"}, {"value": "N/A", "unit": "DD"}], "factory charged": [{"value": "6.63", "unit": "LBS"}, {"value": "3.01", "unit": "Kg"}], "indoor txv subcooling": [{"value": "17", "unit": "F"}], "power supply": [{"value": "208-230", "unit": "volts"}, {"value": "1", "unit": "pk"}, {"value": "60", "unit": "hz"}], "permissible voltage at unit": [{"value": "253", "unit": "max"}, {"value": "197", "unit": "min"}], "compressor": [{"value": "1", "unit": "ph"}, {"value": "60", "unit": "hz"}, {"value": "24.4", "unit": "RLA"}, {"value": "140.0", "unit": "LRA"}], "fan motor": [{"value": "1/4", "unit": "hp"}, {"value": "1.4", "unit": "FLA"}, {"value": "1", "unit": "ph"}, {"value": "60", "unit": "hz"}], "minimum circuit amps": "31.9", "max fuse": "50"}
{"model": "PowerLine E. Air-25", "equipment no": "40192021", "manufactured": "03/2010"}
{"mfg by": "Falcon Trailers", "vim": "jw32512027410C079", "built by": "Falcon Trailers", "model no": "81202", "wheels": "16"}
{"m/n": "RSG1436S1P", "s/n": "1922A04412", "factory charge": [{"value": "7", "unit": "LBS"}, {"value": "1", "unit": "OZ"}], "design pressure hi": [{"value": "448", "unit": "PSIG"}], "design pressure lo": [{"value": "236", "unit": "PSIG"}], "electrical rating": [{"value": "1", "unit": "PH"}, {"value": "60", "unit": "HZ"}], "nominal volts": "208/230", "nominal volts max": "253", "nominal volts min": "197", "compressor": [{"value": "1", "unit": "PH"}, {"value": "13.6", "unit": "RLA"}, {"value": "79.0", "unit": "LRA"}], "fan motor": [{"value": "1", "unit": "PH"}, {"value": "1.6", "unit": "FLA"}, {"value": "1/6", "unit": "HP"}]}
{"serial number": "1358", "vac": "120", "amp": "5.0", "p/c": "701759", "p/n": "592004-001", "mfg code": "01", "made in": "USA"}
{"mawp": [{"value": "200", "unit": "PSI"}, {"value": "100", "unit": "F"}], "mdmt": [{"value": "32", "unit": "F"}, {"value": "200", "unit": "PSI"}], "capacity": [{"value": "2", "unit": "Gallons"}], "part code": "W232CH1120", "flowserve factory order no.": "07MEX915508", "serial number": "07MEX915508-AA A", "year built": "2007"}
{"catalog no.": "35-LM015", "pri. volts": [{"value": "240x480", "unit": "V"}], "sec. volts": [{"value": "24x48", "unit": "V"}], "phase": "SINGLE", "hertz": "50/60", "kva": "150", "weight": [{"value": "6.5", "unit": "LBS"}], "serial no.": "P20224", "encl. rtg": "NEMA TYPE 3R", "ins. system": "416-105", "ins. class": [{"value": "105", "unit": "C"}], "temp. rise": [{"value": "55", "unit": "C"}]}
{"m/n": "HS29-042-5P", "s/n": "5805K60276", "factory charge": [{"value": "5", "unit": "LBS"}, {"value": "7", "unit": "OZS"}], "design pressure hi": [{"value": "278", "unit": "PSIG"}], "design pressure lo": [{"value": "144", "unit": "PSIG"}], "electrical rating": [{"value": "1", "unit": "PH"}, {"value": "60", "unit": "HZ"}], "nominal volts": "208/230", "nominal volts max": "253", "nominal volts min": "197", "compressor": [{"value": "1", "unit": "PH"}, {"value": "20.3", "unit": "RLA"}, {"value": "127", "unit": "LRA"}], "fan motor": [{"value": "1", "unit": "PH"}, {"value": "1.0", "unit": "FLA"}, {"value": "1/6", "unit": "HP"}], "min. ckt ampacity amperage minimum": "26.4", "max fuse or ckt bkr fusible/coupe circuit (hacr per nec)": "40"}
{"p/n": "RHX-CW-FDI", "s/n": "RHX-CW-FDI-43", "the date of manufacture": "December 2004", "power supply": [{"value": "100-240", "unit": "V"}, {"value": "50/60", "unit": "Hz"}], "maximum electric power": [{"value": "500", "unit": "W"}], "wavelength": [{"value": "1.3", "unit": "nm"}], "maximum laser output power": [{"value": "600", "unit": "mW"}]}
{"series no": "2021031901", "laser power": [{"value": "20", "unit": "W"}], "voltage": [{"value": "110-220", "unit": "w"}, {"value": "50-60", "unit": "Hz"}], "marking size": [{"value": "175*175", "unit": "mm"}], "mfd": "Mar 16, 2021"}
{"power supply": [{"value": "208-230", "unit": "Volts"}, {"value": "1", "unit": "PH"}, {"value": "60", "unit": "HZ"}], "permissible voltage at unit": [{"value": "253", "unit": "max"}, {"value": "197", "unit": "min"}], "compressor": [{"value": "208/230", "unit": "TS AC"}, {"value": "1", "unit": "PH"}, {"value": "60", "unit": "HZ"}, {"value": "23.7", "unit": "RLA"}, {"value": "129.0", "unit": "LRA"}], "fan motor": [{"value": "208/230", "unit": "LTS AC"}, {"value": "1/4", "unit": ""}, {"value": "1.4", "unit": "FLA"}, {"value": "1", "unit": "PH"}, {"value": "60", "unit": "HZ"}], "design/test pressure gage hi": [{"value": "300", "unit": "PSI"}, {"value": "2068", "unit": "kPa"}], "design/test pressure gage lo": [{"value": "150", "unit": "PSI"}, {"value": "1034", "unit": "kPa"}], "minimum circuit amps": "31.0", "max fuse": "50", "max ckt - bkr ()": "50"}
{"cat. no.": "DC8H1P1", "serial": "I99", "transformer": "3 PH. ISO.", "insulation class": "220", "pri. volt": "460 DELTA H1-H2-H3", "sec. volt": "460Y/226 X0-X1-X2-X3"}
{"model": [{"name": "LV1", "laser wave length": [{"value": "615", "unit": "nm red"}], "emit power": [{"value": "<1", "unit": "mw"}], "function": "1V1H", "laser class": "class 2", "laser accuracy": [{"value": "+-2.5", "unit": "mm"}, {"value": "5", "unit": "m"}], "laser width": [{"value": "2.5", "unit": "mm"}, {"value": "5", "unit": "m"}], "compensater range": "4*+-1*", "working range": [{"value": "5", "unit": "m in door"}]}, {"name": "LV1G", "laser wave length": [{"value": "520", "unit": "nm greej"}], "emit power": [{"value": "<1", "unit": "mw"}], "function": "1V1H", "laser class": "class 2", "laser accuracy": [{"value": "+-2.5", "unit": "mm"}, {"value": "5", "unit": "m"}], "laser width": [{"value": "2.5", "unit": "mm"}, {"value": "5", "unit": "m"}], "compensater range": "4*+-1*", "working range": [{"value": "5", "unit": "m in door"}]}]}
{"cat. no.": "1552H", "types": ["CY.60", "CL H150"], "h.v.": "240X480", "l.v.": "120/240", "h.v.amps": "62/31", "approx wt.": "235"}
{"made by": "INTERNATIONAL HARVESTER CO.", "model": "C30-157WP", "rating": [{"value": "1 1/2", "unit": "TON"}], "chassis no": "C30-26771", "chassis": "3731", "body, cab, load & equip": "6250", "total gross weight": "9981"}
{"serial num": "SVC1-005", "volts": "110", "amps": "1/2 A", "freq.": [{"value": "60", "unit": "Hz"}], "phase": "1", "psi": "0 to 60 PSI"}
{"power supply": [{"value": "208/230", "unit": "volts"}, {"value": "1", "unit": "Ph"}, {"value": "60", "unit": "Hz"}], "voltage range max": "253", "voltage range min": "187", "min ckt amp": "35.0", "max fuse/hacr cb amp": "50.0", "compressor": [{"value": "208/230", "unit": "volts"}, {"value": "1", "unit": "Ph"}, {"value": "60", "unit": "Hz"}, {"value": "21.0", "unit": "RLA"}, {"value": "NA", "unit": "LRA"}], "fan motor": [{"value": "208/230", "unit": "volts"}, {"value": "1", "unit": "Ph"}, {"value": "60", "unit": "Hz"}, {"value": "1.0x2", "unit": "FLA"}, {"value": "0.11", "unit": "Hp"}, {"value": "85", "unit": "W OUT"}], "refrigerant charge": [{"value": "10.13", "unit": "R410A LBS"}], "design/test pressure gage high": [{"value": "550", "unit": "PSIG"}], "design/test pressure gage low": [{"value": "340", "unit": "PSIG"}]}
{"m/n": "ML14XC1S030-230A04", "s/n": "1922D14393", "factory charge": [{"value": "5", "unit": "LBS"}, {"value": "8", "unit": "OZS"}], "design pressure hi": [{"value": "448", "unit": "PSIG"}], "design pressure lo": [{"value": "236", "unit": "PSIG"}], "electrical rating": [{"value": "1", "unit": "PH"}, {"value": "60", "unit": "HZ"}], "nominal volts": "208/230", "nominal volts max": "253", "nominal volts min": "197", "compressor": [{"value": "1", "unit": "PH"}, {"value": "12.8", "unit": "RLA"}, {"value": "67.3", "unit": "LRA"}], "fan motor": [{"value": "1", "unit": "PH"}, {"value": "1.0", "unit": "FLA"}, {"value": "1/6", "unit": "HP"}], "min. ckt ampacity amperage minimum": "17.0", "max fuse or ckt bkr fusible/coupe circuit (hacr per nec)": "25"}
{"kva": "63", "ph": "3", "hz": "60", "type": "DIT", "class": "AA", "voltage": "460 +/- 5%", "delta": "460Y/266", "current": [{"value": "84 --- 79.1", "unit": "AMPS"}], "wt.": [{"value": "523", "unit": "LBS"}], "insul. sy.": [{"value": "220, 150 rise", "unit": "C"}], "imp": [{"value": "6.9% at 170", "unit": "C"}], "cat. no.": "03006344H6 0298", "sn": "046709-0001"}
{"indoor txu sub cooling": [{"value": "10", "unit": "F"}], "power supply": [{"value": "208/230", "unit": "volts ac"}, {"value": "1", "unit": "Ph"}, {"value": "60", "unit": "Hz"}], "permissible voltage at unit max": "253", "permissible voltage at unit min": "197", "compressor": [{"value": "208/230", "unit": "volts"}, {"value": "1", "unit": "Ph"}, {"value": "60", "unit": "Hz"}, {"value": "13.5", "unit": "RLA"}, {"value": "58.3", "unit": "LRA"}], "fan motor": [{"value": "208/230", "unit": "volts"}, {"value": "1", "unit": "Ph"}, {"value": "60", "unit": "Hz"}, {"value": "0.77", "unit": "FLA"}, {"value": "1/10", "unit": "Hp"}], "design/test pressure gage hi": [{"value": "450", "unit": "PSI"}, {"value": "3103", "unit": "KPA"}], "design/test pressure gage lo": [{"value": "250", "unit": "PSI"}, {"value": "1724", "unit": "KPA"}]}
{"dsgn act": "56529", "p/n": "061481-100", "mfr.": "56529", "nsn": "4920-01-546-5962", "cont. no.": "SPE4A6-19-F9562", "ser. no.": "190262-061481-100-080", "mfr. date": "05/2019"}
{"model": [{"name": "Primary", "kva": "115", "v": "480", "a": "138.5", "ph": "1", "duty": "CONT"}, {"name": "Secondary", "kva": "115", "v": "5.1k/10.2k", "a": "6.5", "ph": "1", "duty": "CONT"}]}
{"type": "AtEX Ex4000", "model": "Ex4000RC-SO", "diff": [{"value": "450", "unit": "MBAR"}], "serial no.": "0705046", "pp": [{"value": "21", "unit": "BAR"}], "mwt": [{"value": "90", "unit": "C"}], "tag no.": "A4097", "y.o.m.": "2007"}