both both tracks tracks slack slack Assemble assemble CQMS CQMS package package UPS UPS needed needed powering powering up up after after cable cable job job Am/fm AM / FM aerial aerial needs needs replacing replacing under under carriage carriage grease grease hose hose blown blown 7897 Exhaust exhaust Fan fan No2 number Overhaul overhaul Elec/Mech electrical / mechanical Air air con conditioner freezing freezing up/low up / low flow flow to to cab cabin Pump pump servo servo line line crimps crimps weeping weeping Large large cable cable reroute reroute for for blast blast Pre pre-cleaner cleaner bowl bowl broken broken / / needs needs replacin replacing Change change out out u/s unserviceable swing swing brake brake cylinder cylinder 060 Worn worn Horizontal horizontal Roller roller x x 2 Replace replace inspect inspect and and repair repair all all rtd's RTDs 22 Bar bar Compressor compressor Service service replace replace short short steer steering U-bolts U-bolts adjust adjust #2 number &3 and hoist hoist brakes brakes cab cabin insulation insulation fallen fallen down down onto onto exhaust exhaust Tie tie Down down Straps straps For for DL DL Cranes cranes Replace replace door door strut strut Grease grease lines lines broken broken 060 Air air reg/drain/filter regulator / drain / filter assy assembly leaking leaking INSPECT inspect HEATER heater N/W not working PROPERLY properly reset reset tritronics/PLC Tri-Tronics / PLC link link modbus Modbus card card Engine engine stopped stopped wil will not not start start main main grease grease supply supply hose hose blown blown No no drag drag excitaion excitation gearshift gearshift indication indication label label u/s unserviceable 7897 Intake intake Fan fan No10 number Overhaul-Elec/Mech overhaul - electrical / mechanical hyd hydraulic hose hose leaking leaking in in centre centre of of machine machine REPAIR repair SUCTION suction PUMP pump N/W not working Crack crack under under L/H left hand propel propel floor floor repair repair teeth teeth cable cable reroute reroute to to eastern eastern sub sub Hi-pressure high pressure clean clean Fairleads fairleads area area Blowout blowout cieling ceiling mounted mounted aircon air conditioner filters filters RH5571 Fuel fuel leak leak @ at Transfer transfer pump pump Empty empty old old service service truck truck grease grease pods pods neutral neutral plane plane adjustment adjustment 1.5mm . mm AP4 Machine machine wont won't take take fuel fuel dirt dirt shute chute sheave sheave segment segment bracket bracket bolts bolts 5H MOBILE mobile LABOUR labour W/ with START start 06/10 pipe pipe missing missing clamp clamp Change change tail tail cable cable ll124 GD9992 Eng engine Elec electrical 24WK week Audit audit replace replace hose hose end end Isolation isolation Handle handle Faulty faulty R air air leak leak from from supply supply hose hose 7897 Tub tub Hook hook Lubrication lubrication & and Inspect inspect Relocate relocate oil oil catcher catcher drain drain hose hose 888 Clar 5172R - - 2000 Hr hour Service service hoist hoist generator generator 1sparking sparking Clearance clearance light light repairs repairs NDT NDT - - Sus suspension Rope rope A A-frame Frame End end Loc location 8 RT RT coolant coolant pump pump not not pumping pumping broken broken grease grease hose hose on on h H-link link Drag drag gen generator overvoltage overvoltage alarms alarms resocket resocket hoist hoist rope rope change change out out leaking leaking injector injector cab cabin leaning leaning bac back check check cab cabin leveling leveling valve valve J Rinachi Exc excavator - - 500hr hour Machine machine Service service Boot boot racks racks & and Tar tar paper paper Racks racks Lost lost gears gears RTD RTD on on Hoist hoist Box box #2 number inner inner input input earth earth strap strap missing missing CLEAN clean MOBILE mobile WORKSHOP workshop WEEK week 01/09 Monitor monitor SRB SRB in in FJ1 hoist hoist chain chain pin pin fell fell out out Remove remove and and overhaul overhaul generator generator 7897 Swing swing No1 number Vertical vertical Shaft-Mechanical shaft - mechanical 7897 Propel propel No3 number Motor motor O/haul-Elec/Mech overhaul - electrical / mechanical Remove remove the the 3rd third inside inside wear wear plate plate 7897 Rear rear A A-frame Frame Legs legs Changeoutut-Mech change out - mechanical Clar 5172R - - Machine machine Service service 500hr hour 7897 - - NDT NDT Sus suspension Rope rope Boom boom End end Loc location 9 EG9576 ladder ladder raise raise fault fault input input seal seal into into l/h left hand walk walk g/b gearbox is is leaking leaking replace replace onrom Omron timer timer on on sinc synchronous motor motor 4 rv6535 rear rear work work light light u/s unserviceable bolts bolts missing missing W/Place workplace Insp inspection - - 0162 Maint maintenance Blg building Ground ground Lvl level Rotating rotating light light inop inoperable Cable cable work work li648 28/01/0012 8664 24WK week HV high voltage Collector collector Ring ring Service service 985 - - 2000 Hr hour Service service stick stick cylinder cylinder leaking leaking Repair repair 2X x cracks cracks in in rear rear floor floor castings castings lighting lighting faults faults No number 5 Hoist hoist Gearbox gearbox lube lube filter filter blocked blocked Elec electrical 1 Wk week Service service Hoist hoist Motor motor #2 number Interpole interpole Cable cable dump dump block block sheave sheave shaft shaft broken broken hoist hoist electrical electrical fault fault 5H Lean lean for for Remington Wksp workshop WK week 16 7897 Lower lower Vert vertical Fairlead fairlead Sheave sheave C/Out change out Overheating overheating -cutting -cutting out out TACHO tachometer NOT not WORKING working GE GE to to attend attend site site and and investigate investigate faults faults top top up up #4 number swing swing gear gearcase case ERRATIC erratic THROTTLE throttle OR or FUEL fuel SOLENOID solenoid Change change over over to to hydranuts HydraNuts RP85 RH right hand Luffing luffing Cylinder cylinder Change change CLEAN clean MOBILE mobile WORKSHOP workshop WEEK week 25/08/0009 +0977 1WK week GET GET Sled sled and and Bucket bucket Insp inspection 5H Lean lean for for Remington Wksp workshop WK week 12 Crack crack in in L/H/S left hand side Bucket bucket rail rail outer outer l/h left hand tooth tooth and and adapter adapter missing missing Replace replace L/Hand left hand wing wing shroud shroud Bkt bucket # number 7 REPLACE replace FRONT front BUMPER bumper R Replace replace all all Undercarriage undercarriage rollers rollers replace replace missing missing battery battery box box bolts bolts Floor floor crack crack repair repair PY5 Compressor compressor 4 Water water Contamination contamination tidy tidy up up tyre tyre bay bay fuel fuel leak leak at at filter filter REPLACE replace DRIVERS drivers FLOOR floor MAT mat Replace replace broken broken lever lever for for trailer trailer ramps ramps scope scope up up problem problem with with fan fan belt belt alignment alignment 7897 Propel propel Motor motor Lube lube Remove remove cable cable out out of of line line 8664 NDT NDT 48WK week Pressure pressure Vessel vessel Insp inspection secure secure broken broken suspension suspension rope rope Cracking cracking in in bulk bulk head head under under opperator operator ca cabin 7897 Pre pre-service Service Inspection inspection Electrical electrical REPLACE replace FRT front RADIATOR radiator PROTECTION protection BAR bar Get GET Sled sled sort sort out out Drivers drivers side side mirror mirror missing missing I2V Lower lower Hoist hoist Chain chain LH left hand access access door door not not shutting shutting track track frames frames worn worn earrth earth continuity continuity fault fault 5635 Swing swing Motor/Blower motor / blower Connection connection Insp inspection 5635 Pre pre-service Service Inspect inspect Elect electrical Platform platform support support cracks cracks above above RHS right hand side Crane crane trace trace and and repair repair air air gauges gauges n/w not working Swing swing Motor motor Number number 3 Field field Coil coil Shorted shorted propel propel grease grease light light 5635 Propel propel Motor/Blower motor / blower Lube lube inspect inspection Remove remove ESCO ESCO SA923 sled sled rear rear hyd hydraulic sight sight glass glass u/s unserviceable Bucket bucket cracking cracking in in LHS left hand side RHS right hand side transitions transitions Cab cabin & and Bonnet bonnet repairs repairs - - Off-site off-site plc PLC fault fault replace replace rear rear cab cabin rollers rollers Lose lose bolt bolt on on upper upper LH left hand fairlead fairlead retainer retainer Potential potential cable cable work work requested requested Inspect inspect YV4 Thrust thrust bearing bearing components components MOBILE mobile Step-up step-up Labour labour W45 week Resocket resocket drag drag ropes ropes 526 Replace replace both both drag drag sockets sockets 5H Lean lean for for Remington Wksp workshop WK week 12 Door door strut strut u/s unserviceable grease grease hoses hoses crushed crushed on on 'h' H-link link T reported reported broken broken spreader spreader bar bar drag drag gen generator over overvoltage voltage refit refit missing missing pin pin in in dump dump rope rope socket socket Safety safety hook hook latched latched cracked cracked C 5542 7 Weekly weekly Servic service Electric electric -Attac - attachement Replace replace GET GET on on Bkt bucket # number 9 Crack crack repair repair to to dampner damper mount mount Replace replace upper upper wiper wiper motor motor Tripping tripping main main circuit circuit breaker breaker Dove 742K - - 2000 Hr hour Air air Con conditioner Service service has has b been TIGHTEN tighten LOOSE loose ROUND round HYD hydraulic TANK tank FK2694 NEW new TYRES tyres POS position 1&2 and ROTATE rotate POS position 7 DC DC 534 Welder welder Blowout blowout Clean clean A/C air conditioner Evaporator evaporator Core core replace replace leaking leaking diff differential through through shaft shaft seal seal Wacky to to install install Brethrs breathers on on DL dragline GBoxs gearboxes NR2 Replace replace control control circuit circuit breaker breaker Cable cable work work ll124 15/04/0011 FI0830 Swing swing No2 number Motor motor Changeout change out FIT fit BUMP bump RUBBERS rubbers UNDER under FRONT front / / MODULE module INSIDE inside SUNSHADE sunshade MISSING missing PA3124 REPAIR repair LEAK leak FROM from TANK tank RETURN return PIPE pipe Fluro Fluro not not working working 060 - - Inspection inspection of of H high V voltage Changeover changeover Swth switch engine engine shutdown shutdown -cable - cable u/s unserviceable REPLACE replace RHS right hand TOP top STEP step ASSM assembly SU1902 c/o change out u/s unserviceable pos position 1 tyre tyre Change change Oil oil PX9 Thrust thrust Clean clean up up walk walk motor motor 8 commutator commutator Change change out out u/s unserviceable grease grease pump pump on on B sys system R/H right hand check check oil oil leak leak on on drag drag Rain rain water water leaking leaking into into cab cabin 526 Change change out out 1-5 - adaptors adaptors + and LH left hand wing wing shroud shroud INSTALL install 526 PEDESTAL pedestal BEARING bearing TEMPERATURE temperature EG9576 Pos position 1 turbo turbo failure failure pin pin hole hole broken broken out out of of dump dump block block roller roller air air horn horn too too loud loud MOBILE mobile 5H Internal internal Labour labour W47 week Lost lost all all gears gears DD1106 - - REPLACE replace FRONT front CRANKSHAFT crankshaft SEAL seal Crib crib hut hut brakes brakes req requires adjusting adjusting Argon H14H - - Overhaul overhaul Serv service Brake brake Front front cab cabin floor floor rusted rusted out out blower blower motor motor u/s unserviceable please please change change repair repair damaged damaged drag drag drum drum guard guard REPORTED reported BLOWN blown HYDRAULIC hydraulic HOSE hose remove remove radiator radiator to to be be sent sent to to Natrad Natrad 7897 - - NDT NDT Sus suspension Rope rope A A-frame Frame End end Loc location 8 Make make no no entry entry gates gates aroung aroung MG motor generator sets sets I change change out out u/s unserviceable pump pump i injection system system repairs repairs to to bucket bucket floor floor lifting lifting CABLE cable MOVED moved AROND around TUB tub replace replace LHS left hand side front front guard guard missing missing plate plate bolts bolts loose loose no no tie tie wire wire Map map out out SA923 cable cable route route Weld weld repair repair to to Dirt dirt chute chute REAR rear RH right hand LIGHT light N/W not working replace replace swing swing vibraguard Vibraguard resistor resistor 5 JY8 Roller roller U/S unserviceable and and 4 bolts bolts missing missing DCS DCS to to come come to to site site for for problems problems on on D/L dragline 5H Lean lean for for Remington Wksp workshop WK week 52 KY5634 a/c air conditioner not not working working Resocket resocket Drag drag ropes ropes 526 D/line dragline Change change oil oil YV4 Lkp0 RH right hand TOP top PLASTIC plastic STEP step BROKEN broken Becket Becket Cyl- cylinder - Bolt bolt Replace replace measure measure jackshaft jackshaft worn worn in in slip slip yoke yoke Hoist hoist motor motor field field fault fault 15W40 W/ PUMP pump FILTERS filters REQUIRE requires REPLACING replacing Assist assist DCS DCS Check/Fit check / fit Reverse reverse alarm alarm Fortnightly fortnightly SA923 sub sub inspection inspection I reported reported engine engine oil oil over over engine engine drad drag temp temperature alarm alarm LK621 Rinachi 2000hr hour Service service Synch synchronous motor motor unbalance unbalance shutdown shutdown Inspect inspect and and repair repair brake brake pins pins quip Kwik tip Tip KI673 Rinachi Daily daily Inspections inspections WK week 52 Remove remove cable cable from from in-line inline grease grease leaks leaks on on H H-link link LK621 Rinachi 1000 Hr hour Service service top top steering steering box box seal seal leaking leaking 5635 Lube lube Service service Aux auxiliary Eng engine -Mech - mechanical grease grease line line off off RH right hand door door strut strut not not working working REPLACE replace LUBE lube MODULE module DOOR door LATCHES latches Spare spare Motor motor Heaters heaters connection connection LK621 Rinachi 4000hr hour Services services Plan plan 5635 Weekly weekly Service service Mechanical mechanical WK week Swing swing Mtr motor Brake brake Exhaust exhaust to to be be checked checked Replace replace R/H/S right hand side propel propel strainer strainer o-ring o-ring engine engine wont won't run run DD1106 c/o change out blown blown hyd hydraulic hose hose r/hand right hand bucket bucket Investigate investigate pump pump drive drive wear wear 9 monthly monthly stat statutory testing testing ll124 spreader spreader bar bar broken broken Grease grease pump pump compressor compressor engine engine no no go go RQ1927 oil oil level level dipstick dipstick U/S unserviceable LK621 Rinachi Daily daily Inspections inspections WK10 week air air leak leak @ at rear rear of of middle middle air air tank tank HYDRAULIC hydraulic SYS system - - BLOWN blown HOSE hose Turnbuckle turnbuckle broken broken on on LH left hand ramp ramp steer steering hubs hubs water water contamination contamination 8664 24WK week Swing swing Mounting mounting Bolt bolt Insp inspection reported reported ripper ripper pin pin u/s unserviceable tracks tracks loose loose Alternator alternator over over charging charging compresor compressor pin pin hole hole 5635 Swing swing Coupling coupling Lube lube & and Inspection inspection REPLACE replace WIRING wiring & and SEAL seal RHR right hand rear ELECTRICAL electrical BOX box REPAIR repair AIR air CLEANER cleaner HOUSING housing engine engine shut shut off off mechanism mechanism n/w not working properly properly LHR left hand rear pos position #7 number  and number rock rock ejector ejector needs needs welding welding Machoona JP 095-6HY Mech mechanical 680 Insp inspection 5635 Hoist hoist Ropes ropes RH right hand Changeout-Mechanical change out - mechanical tighten tighten loose loose module module retaining retaining bolts bolts boom boom point point sheave sheave bumper bumper rubber rubber cracked cracked 3Month month Tool tool Insp inspection Y Crew crew - - Heavy heavy Drag drag generator generator voltage voltage problem problem RH right hand Walk walk Motor motor requires requires 2 arc arc horns horns Dove 742K - - 500 Hr hour Service service 526 1 Weekly weekly Service service Mechanical mechanical REPLACE replace DOOR door LATCH latch 5635 Pre pre-service - Service Inspect inspect Electrical electrical Drivers drivers door door hinges hinges worn worn out out Change change Compressor compressor oil oil 7897 Propel propel Bullgear bullgear LH left hand Changeout-Mech change out - mechanical drag drag in in limit limit not not close close enough enough fit fit passengers passengers side side seatbelt seatbelt Fortnightly fortnightly sub sub inspection inspection FI463 Wear wear plate plate material material hanging hanging off off tub tub swing swing lube lube motor motor #5 number laser laser striker striker fowling fowling on on bottle bottle bolts bolts fit fit ladder ladder storage storage holders holders LK621 Rinachi Service service Day day Wash wash SWING swing LOOP loop 6 GROUND ground FAULT fault grease grease pump pump wont won't run run 220 Argon GI4 - - 500 Hr hour Service service this this ser service Missing missing oil oil filler filler cap cap 5635 VistaCam System system inspect inspect & and Clean clean float float wont won't build build up up air air 8664 12WK week Portable portable Appliance appliance Service service replace replace drive drive spring spring & and trunnion trunnion bushes bushes bp9386 inspections inspections remove remove & and change change over over drivers drivers door door r/h right hand trammel trammel all all welds welds broken broken cable cable work work and and walk walk 888 - - 500 Hr hour Service service Crack crack repair repair LHS left hand side back back of of the the arch arch service service mcc MCC tripping tripping Replace replace quick Kwik tips Tips on on Bkt bucket # number 9 5635 Propel propel Motor/Blower motor / blower Conn connection Inspect inspect CAB cabin SUSPENSION suspension N/W not working HYD hydraulic PIPING piping & and HOSES hoses - - HYD hydraulic HOSE hose stopped stopped with with no no alarms alarms ladder ladder location location sensor sensor struck struck by by paddle paddle 5635 Intake intake Fan fan No1 number Overhaul-Elec/Mech overhaul - electrical / mechanical adjust adjust left left fairlead fairlead anchor anchor rope rope Repair repair hinge hinge on on WS workshop press pressure access access gate gate Power power tripped tripped drag drag motion motion trip trip o system system short short cycling cycling I cam cam lube lube LR2095 Strg storage pump pump case case drain drain hose hose leak leak revolving revolving frame frame light light need need repairs repairs Swing swing Pinion pinion Bolts bolts Replace replace Boom boom rope rope lube lube valve valve leaking leaking Drag drag field field loss loss warning/alarm warning / alarm ladder ladder rung rung missing missing deflection deflection tower tower 985 Argon H14H - - Ansul Ansul System system Service service Reseal reseal all all temp temperature probes probes on on all all MG motor generator sets sets front front wiper wiper blade blade u/s unserviceable 3Month month Tool tool Insp inspection W Crew crew - - Mobile mobile 47 Week week Tool tool Inspection inspection 'O' Crew crew Mobile mobile Argon H14H - - Fuel fuel Injectors injectors Changeout change out check check front front diff differential lock lock ingauging engaging & and dising dosing Cable cable re-route re-route from from O1 to to Milton 534 Rinachi Daily daily Inspections inspections drop drop 8 cables cables out out of of line line RHS right hand side Lower lower Camframe cam frame Inspect inspect - - post post Shut shutdown Cutting cutting Blade blade to to be be turned turned broken broken link link l/h left hand drag drag chain chain C/O change out dump dump blocks blocks swing swing resolver resolver fault fault 7897 - - Weekly weekly Rope rope Work work - - teco TECO 5635 Pre pre-service Service Inspect inspect Electrical electrical R/H/S right hand side Dump dump rope rope damaged damaged a/c air conditioner not not working working shutdown shutdown at at sub sub Upper upper Spreader spreader Bar bar C/O change out Repair repair flood flood light light rear rear rhs right hand side under under deck deck CM-NDT CM - NDT - - A A-frame Frame Walkways walkways VI VI MT MT dump dump rope rope failed failed Resample resample SA923 UG8 Geg5 Oil oil Replace replace r/h right hand machine machine end end connecting connecting link link filter filter housing housing off off RH right hand chassis chassis rail rail 2 monthlyLube monthlyLube Room room Panel panel Service service front front diff differential filter filter mount mount and and pipe pipe leaking leaking cable cable sheathing sheathing damaged damaged MECHANICAL mechanical - - PIN pin TRACK track ROLLER roller Dump dump Block block Ass assembly C/O change out hoist hoist blower blower 6 tripping tripping out out instantaneous instantaneous shutdown shutdown 5635 - - Swing swing Blower blower #4 number to to be be replaced replaced Power power tripped tripped at at sub sub No no restart restart li648 Cracks cracks near near propell propell boxes boxes L/Hside left hand side Argon H14H - - 2000 Hr hour Air air Con conditioner Service service drag drag limits limits reset reset after after crop crop Update update ll124 cable cable run run map map INSPECT inspect BRAKE brake WARNING warning LIGHT light COMING coming UP up LHF left hand front module module compartment compartment mount mount bolts bolts u/s unserviceable recalibrate recalibrate for for bucket bucket # number 3 RHS right hand side Shoe shoe access access handrail handrail broken broken Repair repair r/h right hand rear rear trammel trammel Inspect inspect A/C air conditioner Compressor compressor bolts bolts and and belt belt Welding welding d/b distributor e/l electrical trip trip Clean clean exit exit light light /fan / fan house house light light difuse diffuser 8664 NDT NDT Boom boom Structure structure Insp inspection dragline dragline 3 hoist hoist lube lube valve valve replacement replacement C/O change out upper upper hoist hoist spreader spreader Bar bar Boom boom point point winch winch E/Leakage electrical leakage relay relay faulty faulty Light light Vehicle vehicle 680 Inspection inspection C/O change out No number 6 lip lip shroud shroud Brush brush Arm arm Insulators insulators to to be be fitted fitted noise noise in in no1 number swing swing gearbox gearbox front front sway sway bar bar bushes bushes worn worn out out R/H/S right hand side Propel propel filter filter needs needs changing changing Change change out out #2 number Propel propel mtr motor swing swing loop loop #2 number ground ground fault fault CHECK check ALL all BRAKES brakes 7897 Drag drag Ropes ropes LH left hand Changeout-Mechanical change out - mechanical Fortnigntly fortnightly sub sub inspection inspection Gq142 Both both A-frame A-frame upper upper lights lights out out 7897 Propel propel Bullgear bullgear RH right hand Changeout-Mech change out - mechanical 7897 - - House house Roller roller Bushes bushes Grease grease Go go over over last last 5 days days of of Minvu MinVu reports reports RH right hand DOOR door REQUIRES requires MAINTAINENCE maintenance C 5542 Drag drag Ropes ropes Changeout change out - - Mechanica mechanical CM condition monitoring Oil oil Sampling sampling Dragline dragline 526 PERFORM perform VALVE valve SET/ set / TAPPIT tappit ADJ adjust replace replace lost lost arch arch anchor anchor link link pin pin Unit unit ran ran out out of of fuel fuel MG motor generator 6 overspeed overspeed switch switch faulty faulty Cable cable reroute reroute Crack crack in in boom boom at at # number 4 Bchord chord on on 060 985 Argon H14H 250 Hr hour Service14 service 05 2009