File size: 2,459 Bytes
b24351f
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
{
  "ticketNumber" : "753020",
  "reporterName" : "Bill Johns",
  "rankPoints" : "46985",
  "resolutionStatus" : "Resolved",
  "ticketName" : "[FAQ] BQ24040 and BQ2404X family Charge Complete Pin Behavior, /CHG",
  "rankName" : "Mastermind",
  "replies" : " 1",
  "views" : " 2396",
  "queryText" : "The BQ2404X family of charger has a charge complete pin, /CHG to indicate charge in progress or complete. But under some conditions the battery charge has stopped (no current to battery) but /CHG indicates charge. In other case the battery is charging (current to battery) but /CHG does not indicate charge in progress.",
  "partNumber" : "NA",
  "allResponseList" : [ {
    "contentId" : "2781522",
    "userName" : "Bill Johns",
    "rankPoints" : "46985",
    "rankName" : "Mastermind",
    "date" : "Dec 5, 2018 10:34 PM",
    "userId" : "244698",
    "content" : "This also applies to BQ21040, BQ24050, BQ24090 and BQ25100 family of devices. The /CHRG pin in an open drain output used to indicate that a battery charge cycle is in progress. The pin will go low when the device detects a valid power supply and starts charging the battery. The pin will go high impedance when the device detects that the battery is fully charged (Change Complete/ Termination). In order to optimize end user experience the charger behavior under the particular cases below is as follows: 1.) If TS (NTC) pin indicates an over temp condition charge is suspended, but the /CHG pin will remain low since termination or charge complete has not been detected. Charge will resume when temp is reduced and the /CHG pin will remain low. 2.) The BQ2404X will automatically restart charge if after termination/charge complete the battery voltage drops to Recharge (V-RCH). This is done to maintain the battery fully charged. In this case the /CHG pin will remain high-Z after termination even if the recharge has started. 3.) During OVP shutdown or Charge Timer Fault /CHG is high –Z Note on First Charge Cycle-- will start when power is applied, disable / enable using TS pin or detect battery insertion, /CHG is low. Start charge cycle but not First charge cycle exiting TTDM mode or battery voltage below V-RCH. Additional info see BQ24040 Data Sheet Charge Complete Data Sheet section 8.3.7 also see Table in section 8.4.1. Note -- Updated section 2 May 20, 2019 -- To remain high-Z"
  } ],
  "tags" : [ "/support/power-management/f/196/tags/BQ24040" ],
  "fourmType" : "TI"
}