Spaces:
Runtime error
Runtime error
BQ24707A: IFAULT not tripping when conditions met | |
Part Number: BQ24707A My Ifault pin is pulled up through a 100k resistor to 3.3V. When I apply a dummy load of 3A from ACN to GND, well above the 128mA input current limit of the 0x3f register (by setting 0x3f to 0x0100. nothing causes a trip. is there something wrong with my setyup? here are my registers in format: register: High byte, low byte 0x12: 0x19, 0x04 0x14: 0x08, 0x00 0x15: 0x32, 0x00 0x3f: 0x01, 0x00 because of these register values, acoc should be enabled. I draw 1amp of current, way above 2x the limit of acoc, and the ifault doesn't trip. I've also noticed that the outside pin is exactly correct when charge current is chosen (200mV @ 1A), but the iout pin is wildly inaccurate when input current is chosen (75mV @ 1A charging). this doesnt make sense because the input current is the charging current plus what it takes to run the ic. I've verified we are using a 10m resistor between acn and acp. | |
Hi Alex, Thanks for the information! To keep the forum organized, I have replied to your original thread and will continue the discussion there: <secret URL>/support/power-management/f/196/t/897804 Best regards, Angelo | |