TPS61089: How to improve the performance of load transient | |
Part Number: TPS61089 Hicompany team , My customer used TPS61089 which comp circuit is the same as Typical Application in specfication. But they found the load transmit are not both quickly and good(Test conditons:0A@ 0.5ms ->2A @ 0.5ms) And there is a huge voltage-drop like the following picture. we will appreciate ifcompany can give some advice to improve performance of load transient.Thank you! | |
Dear Sir, We need to know Vin, Vo and your current schematic. | |
Hi Helen , The VIn is 7.2V and the OUT is 12V/3A. The attachment is their sch. Thank you! | |
I found you use a 0.1uF VCC cap, please change it to 2.2uF/16V rating cap. 0.1uF is really too small. But this may not the root cause of the output voltage drop. You can increase the Rcomp=30k, ccomp=2.2nF for a double check, by the way, what is the output cap effective capacitance under 12VDC bias? | |