Ticket Name: TDA2HA-17: Q: Should the power consumption for TDA2x ES2.0 and ES1.1 be equivalent or 'the same' assuming identical configuration? |
|
|
|
Query Text: |
|
Part Number: TDA2HA-17 Question: Should the power consumption for TDA2x ES2.0 and ES1.1 be equivalent or 'the same' assuming identical configuration? Alternatively, should a TI EVM with a TDA2x ES2.0 device have the same or similar power consumption as a TI EVM with a TDA2x ES1.1 device? Alternatively, should a customer target board with a TDA2x ES2.0 device have the same or similar power consumption as a customer target board with a TDA2x ES1.1 device? Does TI have available a spreadsheet that calculates power consumption for a set of used components and IP? Is there a version for TDA2x ES2.0 and TDA ES1.1? Or are they available separately? Many thanks! |
|
|
|
Responses: |
|
Hi Jason, I have forwarded the question to an expert to help. Regards, Yordan |
|
|
|