Spaces:

arjun.a
commit
b24351f
raw
history blame
2.55 kB
{
"ticketNumber" : "892352",
"reporterName" : "Betty Guo",
"rankPoints" : "3070",
"resolutionStatus" : "Resolved",
"ticketName" : "TPS23755: start current of TPS23755",
"rankName" : "Expert",
"replies" : " 4",
"views" : " 31",
"queryText" : "Part Number: TPS23755 Hi team, we want to check how much the startup current? I find that TPS23755 use advance startup, and integrate the current source.",
"partNumber" : " TPS23755",
"allResponseList" : [ {
"contentId" : "3299730",
"userName" : "Michael Pahl",
"rankPoints" : "4915",
"rankName" : "Expert",
"date" : "Mar 27, 2020 10:27 PM",
"userId" : "6102321",
"content" : "Hello Betty, The EVM has a startup waveform that shows the input current on page 6: That will include the current used in advanced startup. If this post answers your question, please indicate so by marking this thread as resolved. Thank you. Regards, Michael P. Applications Engineer customer organization"
}, {
"contentId" : "3300156",
"userName" : "Betty Guo",
"rankPoints" : "3070",
"rankName" : "Expert",
"date" : "Mar 30, 2020 1:35 AM",
"userId" : "5039529",
"content" : "hi Michael, I sitll not clear about the startup current. In the page 6, the Iin is the startup current,right? And, why it have a step and then spike? The startup current is less than 50mA?"
}, {
"contentId" : "3301057",
"userName" : "Michael Pahl",
"rankPoints" : "4915",
"rankName" : "Expert",
"date" : "Mar 30, 2020 5:21 PM",
"userId" : "6102321",
"content" : "Betty, The current shown in page 6 is the input current for the board. This will include the current in the startup circuit. Or, are you needing the specific current associated with the internal current source? If so, why is that number needed versus the overall input current required? The large current spike is inrush, which is limited by the IC. If this post answers your question, please indicate so by marking this thread as resolved. Thank you. Regards, Michael P. Applications Engineer customer organization"
}, {
"contentId" : "3324520",
"userName" : "Michael Pahl",
"rankPoints" : "4915",
"rankName" : "Expert",
"date" : "Apr 22, 2020 3:30 PM",
"userId" : "6102321",
"content" : "Hello, This thread has been inactive for many weeks now. I am going to close it, but feel free to reopen it or start a new thread. Thank you. Regards, Michael Pahl"
} ],
"tags" : [ "/support/power-management/f/196/tags/TPS23755" ],
"fourmType" : "TI"
}