example_id
stringlengths
36
36
content
stringlengths
32
568
processed_content
stringlengths
33
590
label
stringlengths
24
812
metadata
stringlengths
29
67
ef4ec541-e1a7-47d4-9a83-94715d8900ba
Where one or more parking spaces are within a covered car park, the requirement to install electric vehicle charge points should be met by installing charge points in parking spaces that are not within a covered car park.
Where one or more parking spaces are within a covered car park , the requirement to install electric vehicle charge points should be met by installing charge points in parking spaces that are not within a covered car park .
O B-value O O B-object I-object O O O B-quality B-object I-object O O B-object B-quality I-quality I-quality I-quality I-quality I-quality O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '89_UK_DocS_InfrastructureForChargingOfElectricalVehicles'}
a5e9c36f-358f-4375-943c-6d5b89c82647
Any abrupt level differences of over 0.7 metres and any precipices located in the vicinity of common play and recreation areas associated with buildings with more than two dwellings must be indicated by appropriate barriers or suitable planted areas, or outfitted with a base that cushions any fall.
Any abrupt level differences of over 0.7 metres and any precipices located in the vicinity of common play and recreation areas associated with buildings with more than two dwellings must be indicated by appropriate barriers or suitable planted areas , or outfitted with a base that cushions any fall .
O B-quality B-property I-property O O B-value I-value O O B-object O O O B-property O B-quality I-quality O B-quality B-object O O B-object O O O B-value B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '92_Finnish_SafetyOfUse'}
0a6d6be2-bb25-4a7d-ac98-33351e1a2bb7
Wheelchair-accessible bedrooms should be sufficiently spacious to enable a wheelchair user to transfer to one side of a bed, with or without assistance.
Wheelchair-accessible bedrooms should be sufficiently spacious to enable a wheelchair user to transfer to one side of a bed , with or without assistance .
B-quality B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '144_UK_DocM_V2_AccessAndUseOfBuildings'}
7e369e4c-7768-4a7a-bd9c-41e2aa037b43
The air flows shall be designed so that the average carbon monoxide concentration in a parking garage for motor vehicles during the hour of use assessed as the most critical does not exceed 35 mg/m3 (30 ppm).
The air flows shall be designed so that the average carbon monoxide concentration in a parking garage for motor vehicles during the hour of use assessed as the most critical does not exceed 35 mg/m3 ( 30 ppm ) .
O B-object I-object O O B-quality O O O B-property I-property I-property I-property O O B-object I-object B-quality I-quality I-quality B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O B-value I-value I-value I-value I-value I-value O
{'ID': '61_Finnish_Health-IndoorClimateAndVentilation'}
2a2dbb92-88af-47f5-bd1e-b3ddea4c1ec9
The approach route should be safe and convenient for everyone, be at the shallowest gradient that can reasonably be achieved, and be stepfree, irrespective of the storey on which the dwelling is located.
The approach route should be safe and convenient for everyone , be at the shallowest gradient that can reasonably be achieved , and be stepfree , irrespective of the storey on which the dwelling is located .
O B-object I-object O O B-quality I-quality I-quality I-quality I-quality O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O B-quality I-quality O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '70_UK_DocM_V1_AccessAndUseOfBuildings'}
9953a539-8775-467a-9028-f51fe6d0f9f6
Grommets or flexible collars should be used around incoming services and sealed to the air barrier with air-sealing tape or sealant.
Grommets or flexible collars should be used around incoming services and sealed to the air barrier with air-sealing tape or sealant .
B-object O B-object I-object O O B-quality I-quality I-quality I-quality O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '179_UK_DocL_V1_ConsrvationOfFuelAndPower'}
c145afb4-469c-49a7-a14f-167094cf055e
People should be able to appreciate easily where to place their feet by highlighting nosings and avoiding open rises.
People should be able to appreciate easily where to place their feet by highlighting nosings and avoiding open rises .
B-object O O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '54_UK_DocM_V2_AccessAndUseOfBuildings'}
b6e6ebce-e75f-4fae-b9a2-e35c164b3fb4
Where onsite electricity generation and storage is installed, such as photovoltaic panels or battery storage, systems should be an appropriate size for the site, available infrastructure and onsite energy demand.
Where onsite electricity generation and storage is installed , such as photovoltaic panels or battery storage , systems should be an appropriate size for the site , available infrastructure and onsite energy demand .
O B-object I-object I-object I-object I-object O B-quality O O O B-object I-object O B-object I-object O B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '342_UK_DocL_V1_ConsrvationOfFuelAndPower'}
e061791c-7881-43fe-a272-beec4a972b0c
The panel should be securely held in place.
The panel should be securely held in place .
O B-object O O B-quality I-quality I-quality I-quality O
{'ID': '31_UK_DocQ_Security_Dwellings'}
1d10aa43-7650-46b1-83c3-867f212ab9c3
Background ventilators should meet the performance standards for both of the following: a. air flow from outside to inside the dwelling; b. air flow from inside the dwelling to outside.
Background ventilators should meet the performance standards for both of the following : a . air flow from outside to inside the dwelling ; b . air flow from inside the dwelling to outside .
B-object I-object O O O B-property I-property O O O O O O O O B-object I-object B-quality I-quality I-quality I-quality I-quality I-quality O O O B-object I-object B-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '58_UK_DocF_V1_Ventilation'}
043258d7-d35e-42d9-87c5-b83565c39ad6
Before elements are concealed by subsequent work, an onsite audit should be undertaken to confirm that the designed details have been constructed.
Before elements are concealed by subsequent work , an onsite audit should be undertaken to confirm that the designed details have been constructed .
O B-object O B-quality I-quality I-quality I-quality O O B-quality B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '133_UK_DocL_V1_ConsrvationOfFuelAndPower'}
dae0db09-fd4b-4f2c-99c0-cd742b19d17a
A glass structure or other light-permeable structure, along with its mountings, must withstand the load to which it is normally subject, unless the structure is protected by a fixed collision barrier.
A glass structure or other light-permeable structure , along with its mountings , must withstand the load to which it is normally subject , unless the structure is protected by a fixed collision barrier .
O B-object I-object O O B-object I-object O O O B-object B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O B-object O B-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '68_Finnish_SafetyOfUse'}
4d80c4d1-08ee-481a-9f9c-e9151ce1094d
The area of windows, roof windows, rooflights and doors should not exceed 25 of the total floor area of the dwelling.
The area of windows , roof windows , rooflights and doors should not exceed 25 of the total floor area of the dwelling .
O B-property O B-object O B-object I-object O B-object O B-object O O O B-value O O B-property I-property I-property O O B-object O
{'ID': '421_UK_DocL_V1_ConsrvationOfFuelAndPower'}
ca1e0369-2dfe-4cf2-8194-87f72ee5a633
Vertical, horizontal and slinky ground arrays in particular should be flushed in both directions.
Vertical , horizontal and slinky ground arrays in particular should be flushed in both directions .
B-quality O B-quality O B-quality B-object I-object O O O O B-quality I-quality I-quality I-quality O
{'ID': '385_UK_DocL_V1_ConsrvationOfFuelAndPower'}
07565483-7508-43fc-b15e-82d95881e81e
The average dwelling primary energy rate, dwelling emission rate and dwelling fabric energy efficiency rate should be calculated using the same averaging methodology.
The average dwelling primary energy rate , dwelling emission rate and dwelling fabric energy efficiency rate should be calculated using the same averaging methodology .
O B-quality B-property I-property I-property I-property O B-property I-property I-property O B-property I-property I-property I-property I-property O O B-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '70_UK_DocL_V1_ConsrvationOfFuelAndPower'}
d56a51f7-6ec0-457b-a9ed-263fffe3a3e2
Once open, all doors to accessible entrances should be wide enough to allow unrestricted passage for a variety of users, including wheelchair users, people carrying luggage, people with assistance dogs, and parents with pushchairs and small children.
Once open , all doors to accessible entrances should be wide enough to allow unrestricted passage for a variety of users , including wheelchair users , people carrying luggage , people with assistance dogs , and parents with pushchairs and small children .
O B-quality O O B-object O B-quality B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '66_UK_DocM_V2_AccessAndUseOfBuildings'}
a894077e-cebf-4559-9254-ce964bc11b0f
Air flow rates for mechanical ventilation in new dwellings must be measured.
Air flow rates for mechanical ventilation in new dwellings must be measured .
B-property I-property I-property O B-quality B-object O B-quality B-object O O B-quality O
{'ID': '182_UK_DocF_V1_Ventilation'}
656aa2fa-18cb-41ee-ae28-28deb3dffcc3
The water temperature of the water in the hot water system shall be at least 55 degrees Celsius and available from the hot water plumbing fixture within 20 seconds.
The water temperature of the water in the hot water system shall be at least 55 degrees Celsius and available from the hot water plumbing fixture within 20 seconds .
O B-property I-property O O B-object O O B-object I-object I-object O O O O B-value I-value I-value O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '61_Finnish_Health-WaterAndSewerage'}
6465e5b9-4c10-41ec-9839-3e7cb7114911
Programmable room thermostats with an override feature should be provided for all direct electric zones of the electric underfloor heating system.
Programmable room thermostats with an override feature should be provided for all direct electric zones of the electric underfloor heating system .
B-quality B-object I-object B-quality I-quality I-quality I-quality O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '314_UK_DocL_V1_ConsrvationOfFuelAndPower'}
6414854d-01f9-481f-a7f4-c4581e48d8b1
Special safety features are not necessary if the ladder is not more than 6m long.
Special safety features are not necessary if the ladder is not more than 6m long .
B-quality B-object I-object O B-quality I-quality O O B-object O O O O B-value B-property O
{'ID': '112_UK_DocK_ProtectionFromFalling'}
9494f4b9-aae0-4668-aebb-1d8851dd0824
In refreshment facilities, bars and counters (or sections of them) should be at a level suitable for wheelchair users.
In refreshment facilities , bars and counters ( or sections of them ) should be at a level suitable for wheelchair users .
O B-object I-object O B-object I-object I-object O O B-property O O O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '127_UK_DocM_V2_AccessAndUseOfBuildings'}
108b5709-f035-4697-ba25-56edd2ce60fc
Where permanent or removable seating is provided as part of the design, allowance should be made for disabled people to have a choice of seating location at spectator events.
Where permanent or removable seating is provided as part of the design , allowance should be made for disabled people to have a choice of seating location at spectator events .
O B-quality O B-quality B-object O B-quality I-quality I-quality I-quality I-quality I-quality O O O O O O B-object I-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '126_UK_DocM_V2_AccessAndUseOfBuildings'}
c384013b-c40f-4925-acbe-465e1ca5bc13
One photograph per detail should be recorded.
One photograph per detail should be recorded .
B-value B-object B-quality I-quality O O B-quality O
{'ID': '480_UK_DocL_V1_ConsrvationOfFuelAndPower'}
12f51746-1632-4628-9d8a-98dcf58ed9fc
Doors must be capable of opening outwards - in wheelchair adaptable bathrooms the door may open inwards providing that the door can be easily rehung to open outwards (e.g. door stops are planted and easily moved).
Doors must be capable of opening outwards - in wheelchair adaptable bathrooms the door may open inwards providing that the door can be easily rehung to open outwards ( e.g . door stops are planted and easily moved ) .
B-object O O B-quality I-quality I-quality I-quality O O B-quality I-quality B-object O B-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O O O O O O O O O O
{'ID': '116_UK_DocM_V1_AccessAndUseOfBuildings'}
2f75848b-a39a-41d3-a6bf-25ef1154bcff
Where appropriate, these should be automated (with manual override) so that energy savings are maximised.
Where appropriate , these should be automated ( with manual override ) so that energy savings are maximised .
O O O B-object O O B-quality I-quality I-quality I-quality I-quality I-quality O O B-object I-object O B-quality O
{'ID': '322_UK_DocM_V2_AccessAndUseOfBuildings'}
2f89cb06-3ee9-49b5-ac36-46f31ae3928f
Hot water pipework should be insulated in all areas inside and outside the building unless it can be demonstrated that the heat is always useful.
Hot water pipework should be insulated in all areas inside and outside the building unless it can be demonstrated that the heat is always useful .
B-object I-object I-object O O B-quality O O B-object B-quality O B-quality O B-object O O O O O O O B-object O B-quality I-quality O
{'ID': '170_UK_DocM_V2_AccessAndUseOfBuildings'}
d04d6702-5170-4b50-9bda-7367a24e9322
NOTE: The network distribution point could be in a cabinet, a box mounted on a wall or on a telegraph pole.
NOTE : The network distribution point could be in a cabinet , a box mounted on a wall or on a telegraph pole .
O O O B-object I-object I-object O O O O B-object O O B-object B-quality I-quality I-quality I-quality O O O B-object I-object O
{'ID': '5_UK_DocR_V1_InfrastructureForElectircalCommunications'}
9a574829-3211-4b4f-8c0c-c7a7ab9cfd54
The whole building ventilation rate should be met.
The whole building ventilation rate should be met .
O B-quality B-object B-property I-property O O B-quality O
{'ID': '47_UK_DocF_V2_Ventilation'}
aaca648c-5f60-4300-a30f-887da252ebd0
The use of visually and acoustically reflective wall surfaces should be minimised within the lifting platform to prevent discomfort for people with visual and hearing impairment.
The use of visually and acoustically reflective wall surfaces should be minimised within the lifting platform to prevent discomfort for people with visual and hearing impairment .
O B-property O B-quality O B-quality I-quality B-object I-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '116_UK_DocM_V2_AccessAndUseOfBuildings'}
a8b3e54e-902c-4502-99a2-8c41d46f1416
If there are more than 60 chairs in a space, they must be linked to one another in at least four groups, unless the chairs are placed around tables.
If there are more than 60 chairs in a space , they must be linked to one another in at least four groups , unless the chairs are placed around tables .
O O O O O B-value B-object O O B-object O B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O B-object O B-quality I-quality I-quality O
{'ID': '106_Finnish_SafetyOfUse'}
992e8f11-81ac-4d2f-b7d1-60e46b4b7261
Wheelchair accessible dwellings must also provide both a level access shower and a bath.
Wheelchair accessible dwellings must also provide both a level access shower and a bath .
B-quality I-quality B-object O O O O O B-quality I-quality B-object O O B-object O
{'ID': '108_UK_DocM_V1_AccessAndUseOfBuildings'}
29c431ee-ea93-491d-ab13-06418d93c488
If luminous efficacy is greater than 75 light source lumens per circuit-watt, manual control is acceptable.
If luminous efficacy is greater than 75 light source lumens per circuit-watt , manual control is acceptable .
O B-property I-property O O O B-value I-value I-value I-value I-value I-value O B-quality B-object O B-quality O
{'ID': '338_UK_DocL_V1_ConsrvationOfFuelAndPower'}
3d0bbf85-327f-4f92-a468-201f81080779
The roof insulation should be installed when the eaves are still accessible.
The roof insulation should be installed when the eaves are still accessible .
O B-object B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '169_UK_DocL_V1_ConsrvationOfFuelAndPower'}
d791b3d9-ff45-46d6-90d4-39fdaf9d0879
Lighting should be designed based on CIBSEs SLL Lighting Handbook or an equivalent design guide.
Lighting should be designed based on CIBSEs SLL Lighting Handbook or an equivalent design guide .
B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '310_UK_DocM_V2_AccessAndUseOfBuildings'}
87c9c5f5-18dc-4107-b4af-b44dfb2b9627
The effective rated output should be assessed based on the final installed capacity of the heating or air-conditioning system.
The effective rated output should be assessed based on the final installed capacity of the heating or air-conditioning system .
O B-quality B-property I-property O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '326_UK_DocM_V2_AccessAndUseOfBuildings'}
333110c1-ba9e-4c1d-9249-6604f49ba09a
The presence of doors, whether open or closed, should be apparent to visually impaired people through the careful choice of colour and material for the door and its surroundings.
The presence of doors , whether open or closed , should be apparent to visually impaired people through the careful choice of colour and material for the door and its surroundings .
O B-property O B-object O O B-quality O B-quality O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '91_UK_DocM_V2_AccessAndUseOfBuildings'}
07336e23-ffc0-4625-9dca-73c1eb5808c7
Purge ventilation should be capable of extracting at least four air changes per hour per room directly to the outside.
Purge ventilation should be capable of extracting at least four air changes per hour per room directly to the outside .
B-object I-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '47_UK_DocF_V1_Ventilation'}
80221d2c-8ba8-4700-b219-c35fde50f35e
No more than two drainage wells may be connected to a floor drain and they may be located at a maximum distance of three meters from the floor drain.
No more than two drainage wells may be connected to a floor drain and they may be located at a maximum distance of three meters from the floor drain .
O O O B-value B-object I-object O O O O O B-object I-object O O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '125_Finnish_Health-WaterAndSewerage'}
83ff563b-077a-4849-b526-382fbb012647
The breaking of a glass structure or other light-permeable structure of a building must not cause a danger of falling or a danger of injury from fragments falling onto persons below.
The breaking of a glass structure or other light-permeable structure of a building must not cause a danger of falling or a danger of injury from fragments falling onto persons below .
O B-property O O B-object I-object O O B-object I-object O O B-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '67_Finnish_SafetyOfUse'}
5962048f-577c-408a-be59-cbf79bd74630
Requirements for accessibility should be balanced against preserving historic buildings or environments.
Requirements for accessibility should be balanced against preserving historic buildings or environments .
B-object O B-quality O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '7_UK_DocM_V1_AccessAndUseOfBuildings'}
8e7e4d9a-05b8-4512-91c5-e8dbb9488685
At night, windows, patio doors and balcony doors should be modelled as closed.
At night , windows , patio doors and balcony doors should be modelled as closed .
B-quality I-quality O B-object O B-object I-object O B-object I-object O O B-quality I-quality I-quality O
{'ID': '55_UK_DocO_Overheating'}
1e3d8e3a-93fd-47e2-833e-d7f36c901c77
Skirtings totalling up to 50mm total thickness and shallow projecting ducts or casings above 1800mm may be discounted when measuring clear width.
Skirtings totalling up to 50mm total thickness and shallow projecting ducts or casings above 1800mm may be discounted when measuring clear width .
B-object O O O B-value B-property I-property O B-property I-property B-object O B-object O B-value O O B-quality I-quality I-quality I-quality I-quality O
{'ID': '131_UK_DocM_V1_AccessAndUseOfBuildings'}
70cd7164-bc50-4b16-95b0-432188db4ea5
Buildings located near to significant local pollution sources should be designed to minimise the intake of external air pollutants.
Buildings located near to significant local pollution sources should be designed to minimise the intake of external air pollutants .
B-object B-quality I-quality I-quality I-quality I-quality I-quality I-quality O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '80_UK_DocO_Overheating'}
113b8bf8-1856-45f5-a54b-d65ef100b437
If a gas-fired combination boiler is installed in an existing dwelling, at least one of the following energy efficiency measures, appropriate to the system, should be installed.
If a gas-fired combination boiler is installed in an existing dwelling , at least one of the following energy efficiency measures , appropriate to the system , should be installed .
O O B-quality B-object I-object O O O O B-quality B-object O O O B-value O O B-quality B-property I-property I-property O B-quality I-quality I-quality I-quality O O O O O
{'ID': '262_UK_DocL_V1_ConsrvationOfFuelAndPower'}
a43037b0-8e35-45a2-9f23-c2d65f6c5a64
Where access to the dwelling can be gained via an interconnecting doorset from the garage, then either the garage doorset (pedestrian and vehicular) or the interconnecting doorset should be a secure doorset.
Where access to the dwelling can be gained via an interconnecting doorset from the garage , then either the garage doorset ( pedestrian and vehicular ) or the interconnecting doorset should be a secure doorset .
O B-quality O O B-object O O B-object I-object I-object I-object I-object I-object I-object I-object O O O O B-object I-object O B-quality O B-quality O O O B-object I-object O O O B-object I-object O
{'ID': '8_UK_DocQ_Security_Dwellings'}
f2e57c55-e340-4fa2-87c5-03f4bf8e5942
Where the dwelling is defined as wheelchair adaptable, it should be easy to install a lift.
Where the dwelling is defined as wheelchair adaptable , it should be easy to install a lift .
O O B-object O O O B-quality I-quality O O O O B-quality I-quality I-quality I-quality I-quality O
{'ID': '82_UK_DocM_V1_AccessAndUseOfBuildings'}
fb3922fb-8844-40e2-98f5-86e8cccabc72
Cable routes should be provided from a metered electricity supply point to the future connection location.
Cable routes should be provided from a metered electricity supply point to the future connection location .
B-object I-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '107_UK_DocS_InfrastructureForChargingOfElectricalVehicles'}
0fdce0b1-7992-401f-aa84-ad7f2acca23d
Cavity walls: the inner block leaf mortar joint should be fully filled and pointed within the cavity.
Cavity walls : the inner block leaf mortar joint should be fully filled and pointed within the cavity .
B-object I-object O O B-quality B-object I-object B-object I-object O O B-quality I-quality O B-quality I-quality I-quality I-quality O
{'ID': '184_UK_DocL_V1_ConsrvationOfFuelAndPower'}
2af8ee5f-9d05-4023-9365-d093ebdfba1f
Where building work is carried out in a kitchen or bathroom, any existing fans (including cooker hoods, where they extract to the outside) should be retained or replaced.
Where building work is carried out in a kitchen or bathroom , any existing fans ( including cooker hoods , where they extract to the outside ) should be retained or replaced .
O B-object I-object O O O O O B-object O B-object O O B-quality B-object I-object I-object I-object I-object I-object I-object I-object I-object I-object I-object I-object I-object O O B-quality O B-quality O
{'ID': '168_UK_DocF_V1_Ventilation'}
2695c899-0ada-478c-9b2d-796f79ea4c52
Glazing, with which people are likely to come into contact whilst moving in or about the building shall: (a) if broken on impact, break in a way which is unlikely to cause injury; or (b) resist impact without breaking; or (c) be shielded or protected from impact.
Glazing , with which people are likely to come into contact whilst moving in or about the building shall : ( a ) if broken on impact , break in a way which is unlikely to cause injury ; or ( b ) resist impact without breaking ; or ( c ) be shielded or protected from impact .
B-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O O O O B-quality I-quality I-quality O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O O O B-quality I-quality I-quality I-quality O O O O O B-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '92_UK_DocK_ProtectionFromFalling'}
16f6f10e-f32f-48b2-85f9-123cdb5448ee
Any unavoidable gaps between boards should be infilled using compressible tape (e.g. for boards within roof rafters) or low expansion foam (e.g. for boards within wall cavities).
Any unavoidable gaps between boards should be infilled using compressible tape ( e.g . for boards within roof rafters ) or low expansion foam ( e.g . for boards within wall cavities ) .
O B-quality B-object B-quality I-quality O O B-quality O B-object I-object O O O O O O O O O O B-object I-object I-object O O O O O O O O O O
{'ID': '147_UK_DocL_V1_ConsrvationOfFuelAndPower'}
64aead92-11dc-49ab-9086-c86f6d1f9c3e
A dynamic calculation tool shall be used for the calculation of the room temperature for the summer season.
A dynamic calculation tool shall be used for the calculation of the room temperature for the summer season .
O B-quality B-object I-object O O O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '162_Finnish_EnergyEfficiency'}
45338082-ca66-418b-8fe1-8f2be926f330
A cube of no more than 100 millimetres may pass between the stair steps.
A cube of no more than 100 millimetres may pass between the stair steps .
O B-object O O O O B-value I-value O B-quality I-quality I-quality I-quality I-quality O
{'ID': '52_Finnish_SafetyOfUse'}
590ab551-79e8-42f5-bc52-749f8899c088
Extinguishing routes to basement storeys shall be arranged so that basement storeys can be reached from the ground level without a need to pass through the exits of the storeys.
Extinguishing routes to basement storeys shall be arranged so that basement storeys can be reached from the ground level without a need to pass through the exits of the storeys .
B-object I-object B-quality I-quality I-quality O O B-quality O O B-object I-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '242_Finnish_FireSafety'}
c0a6d35c-cc20-428b-941d-c3e3e6365c74
In a tier that is uninterrupted by cross-gangways, and where the pitch exceeds 25, use a maximum number of steps of 40.
In a tier that is uninterrupted by cross-gangways , and where the pitch exceeds 25 , use a maximum number of steps of 40 .
O O B-object O O B-quality I-quality I-quality O O O O B-property O B-value O O O B-quality B-property O B-property O B-value O
{'ID': '25_UK_DocK_ProtectionFromFalling'}
7f3f59a4-fc7e-4b14-8074-384f6cacf548
The height of a barrier in a dwellings indoor areas may, however, be at least 0.9 metres if the drop is less than three metres.
The height of a barrier in a dwellings indoor areas may , however , be at least 0.9 metres if the drop is less than three metres .
O B-property O O B-object O O B-object B-object I-object O O O O O O O B-value I-value O O B-property O O O B-value I-value O
{'ID': '45_Finnish_SafetyOfUse'}
85cf77b8-70aa-4453-8d95-00f55a63c4ca
The provision made must be sufficient to (a) allow simple adaptation of the dwelling to meet the needs of occupants who use wheelchairs; or (b) meet the needs of occupants who use wheelchairs.
The provision made must be sufficient to ( a ) allow simple adaptation of the dwelling to meet the needs of occupants who use wheelchairs ; or ( b ) meet the needs of occupants who use wheelchairs .
O B-object O O O O O O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '65_UK_DocM_V1_AccessAndUseOfBuildings'}
6cd271a0-e7d4-4853-868f-38e8b5012a95
The approach route should be safe and convenient for everyone, including older and disabled people and some wheelchair users.
The approach route should be safe and convenient for everyone , including older and disabled people and some wheelchair users .
O B-object I-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '13_UK_DocM_V1_AccessAndUseOfBuildings'}
8102cb27-2e2a-4008-99d6-a53f5045f6e2
Structures with surfaces exposed to moisture must be resistant to the effects of water.
Structures with surfaces exposed to moisture must be resistant to the effects of water .
B-object O B-property B-quality I-quality I-quality O O B-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '36_Finnish_Health-Humidity'}
fdd9e41e-20a5-4f5b-9dae-91653467c3ec
Multiple cooling units should be provided with controls that ensure that the combined plant operates in its most efficient modes.
Multiple cooling units should be provided with controls that ensure that the combined plant operates in its most efficient modes .
B-quality B-object I-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '275_UK_DocM_V2_AccessAndUseOfBuildings'}
d988e207-c3f9-4314-9a16-f99b334595f4
The tread must be no less than 270 millimetres.
The tread must be no less than 270 millimetres .
O B-property O O O O O B-value I-value O
{'ID': '26_Finnish_SafetyOfUse'}
015b966c-962b-4505-b742-21eaabe0240a
Where there is a prevailing wind direction, exhaust outlets should be downwind of intakes.
Where there is a prevailing wind direction , exhaust outlets should be downwind of intakes .
O O O O B-property I-property I-property O B-object I-object O O B-quality I-quality I-quality O
{'ID': '130_UK_DocF_V1_Ventilation'}
a9944ed0-7168-4ec7-b761-0641e3e3228b
The sewerage system shall be equipped with cleanouts that are easy to handle and lockable in both horizontal and vertical sewers.
The sewerage system shall be equipped with cleanouts that are easy to handle and lockable in both horizontal and vertical sewers .
O B-object I-object O O O O B-object O O B-quality I-quality I-quality O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '157_Finnish_Health-WaterAndSewerage'}
7575211d-616b-42bb-b112-73a949e7ca6a
Any combined facility should be divided into distinct wet and dry areas.
Any combined facility should be divided into distinct wet and dry areas .
O B-quality B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '176_UK_DocM_V2_AccessAndUseOfBuildings'}
23619605-28c0-46ef-bdbb-d1dc11691b8f
Water must not drift into or migrate as a capillary flow from the wet rooms to the surrounding structures and rooms.
Water must not drift into or migrate as a capillary flow from the wet rooms to the surrounding structures and rooms .
B-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '109_Finnish_Health-Humidity'}
01bd7c41-594c-4440-8058-c34f1c4bad09
When determining the free area available for ventilation during sleeping hours, only the proportion of openings that can be opened securely should be considered to provide useful ventilation.
When determining the free area available for ventilation during sleeping hours , only the proportion of openings that can be opened securely should be considered to provide useful ventilation .
O O O B-object I-object B-quality I-quality I-quality I-quality I-quality I-quality O O O B-value O B-object O O O B-quality I-quality O O B-quality I-quality I-quality I-quality I-quality O
{'ID': '82_UK_DocO_Overheating'}
26f33f06-e967-4d55-9e73-30990f52ac82
Loft hatches: where the roof is insulated at ceiling level, hatches should be suitably designed and installed to ensure optimum airtightness.
Loft hatches : where the roof is insulated at ceiling level , hatches should be suitably designed and installed to ensure optimum airtightness .
B-object I-object O O O B-object O B-quality I-quality I-quality I-quality O B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '189_UK_DocL_V1_ConsrvationOfFuelAndPower'}
197b9463-397e-4729-a08d-12739f9db069
For variable refrigerant flow (VRF) systems, any calculations must include indoor and outdoor conditions, the power input from controls, and indoor units.
For variable refrigerant flow ( VRF ) systems , any calculations must include indoor and outdoor conditions , the power input from controls , and indoor units .
O B-quality B-object I-object I-object I-object I-object I-object O B-quality B-property O O B-property I-property I-property I-property O O B-property I-property I-property I-property O O B-property I-property O
{'ID': '283_UK_DocM_V2_AccessAndUseOfBuildings'}
b5aa20f2-571e-48d8-9943-4102c9f9bd1a
In exit passageways and fire-compartmented elevator shafts, means must be arranged for both smoke extraction and flow of replacement air.
In exit passageways and fire-compartmented elevator shafts , means must be arranged for both smoke extraction and flow of replacement air .
O B-object I-object O B-quality B-object I-object O B-object O O O O O B-quality I-quality O B-quality I-quality I-quality I-quality O
{'ID': '250_Finnish_FireSafety'}
9b329413-b6d6-4953-9b34-c82d3a2e9c44
Before a new heating appliance is installed, all central heating and primary hot water circuits should be thoroughly cleaned and flushed out.
Before a new heating appliance is installed , all central heating and primary hot water circuits should be thoroughly cleaned and flushed out .
O O O B-object I-object O B-quality O O B-object I-object O B-quality B-object I-object I-object O O B-quality I-quality I-quality I-quality I-quality O
{'ID': '216_UK_DocM_V2_AccessAndUseOfBuildings'}
2702a3b3-b2a8-4457-86e8-3e7de2498dc3
landing call buttons are located between 900mm and 1100mm from the floor of the landing and at least 500mm from any return wall.
landing call buttons are located between 900mm and 1100mm from the floor of the landing and at least 500mm from any return wall .
B-object I-object I-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '185_UK_DocM_V2_AccessAndUseOfBuildings'}
956efc87-87de-4d3c-99fb-dc58eab9353b
A dwelling that is intended for sheltered housing or supported housing of a person with mobility or functional impairment shall have at least one toilet and washing facility which has a free space with a diameter of at least 1,500 millimetres.
A dwelling that is intended for sheltered housing or supported housing of a person with mobility or functional impairment shall have at least one toilet and washing facility which has a free space with a diameter of at least 1,500 millimetres .
O B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O O B-value B-object I-object I-object I-object O O O B-object I-object O O B-property O O O B-value I-value O
{'ID': '42_Finnish_Accessibility'}
fe2a31f5-7b10-4b21-ad13-154856ecdcc8
Where sheathing board forms the air barrier, airsealing tape should be applied at junctions and edges.
Where sheathing board forms the air barrier , airsealing tape should be applied at junctions and edges .
O B-object I-object B-quality I-quality I-quality I-quality O B-object I-object O O B-quality I-quality I-quality I-quality I-quality O
{'ID': '186_UK_DocL_V1_ConsrvationOfFuelAndPower'}
ffbc85cb-4301-4bcb-9a56-7487c95cf16d
Only the proportion of openings which can be opened with a very low risk of occupants falling from height should be considered to form part of the overheating mitigation strategy.
Only the proportion of openings which can be opened with a very low risk of occupants falling from height should be considered to form part of the overheating mitigation strategy .
O O B-value O B-object O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '83_UK_DocO_Overheating'}
5f7b8ff7-50d0-46a2-a48b-fa19786c98fd
If the domestic hot water cylinder is located inside the building envelope, 50 of the calculated domestic hot water cylinder heat loss shall be added to the thermal load of the spaces of the building.
If the domestic hot water cylinder is located inside the building envelope , 50 of the calculated domestic hot water cylinder heat loss shall be added to the thermal load of the spaces of the building .
O O B-quality B-object I-object I-object O B-quality I-quality I-quality I-quality I-quality O B-value O O B-quality B-property I-property I-property I-property I-property I-property O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '105_Finnish_EnergyEfficiency'}
d30364dd-539e-4351-9d53-89ad358a4b44
U-values for rooflights or rooflight-and-kerb assemblies should be based on the outer developed surface area, which is often greater than the area of the roof opening.
U-values for rooflights or rooflight-and-kerb assemblies should be based on the outer developed surface area , which is often greater than the area of the roof opening .
B-property O B-object O B-object I-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '122_UK_DocL_V1_ConsrvationOfFuelAndPower'}
7d877df3-9aa7-4dff-a64d-5356a66c944d
In public outdoor and indoor spaces, and in business and service premises, a handrail must continue at least 300 millimetres past the start and end points of the structure, and in the case of stairs or ramps that have a width exceeding 2.4 metres and are located in assembly areas, it must also be placed so as to divide the passageway into parts no wider than the abovementioned width.
In public outdoor and indoor spaces , and in business and service premises , a handrail must continue at least 300 millimetres past the start and end points of the structure , and in the case of stairs or ramps that have a width exceeding 2.4 metres and are located in assembly areas , it must also be placed so as to divide the passageway into parts no wider than the abovementioned width .
O B-quality B-object I-object I-object I-object O O O B-quality O B-quality B-object O O B-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O O O O B-object O B-object O O O B-property O B-value I-value O O B-quality I-quality I-quality I-quality O O O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '59_Finnish_SafetyOfUse'}
09b2a395-5293-4b7d-82d4-5312482d59e9
Door entry controls, where provided, are mounted 900-1000mm above finished ground level, and at least 300mm away from any projecting corner.
Door entry controls , where provided , are mounted 900-1000mm above finished ground level , and at least 300mm away from any projecting corner .
B-object I-object I-object O O O O O B-quality B-value B-property B-quality B-object I-object O O O O B-value B-property O O B-object I-object O
{'ID': '46_UK_DocM_V1_AccessAndUseOfBuildings'}
f050b9bc-ce9e-4e51-8291-bbabda986732
all dimensions are minimum except where noted.
all dimensions are minimum except where noted .
O B-property O B-quality I-quality I-quality I-quality O
{'ID': '88_UK_DocM_V1_AccessAndUseOfBuildings'}
a372d2c4-f734-479d-bc8d-d3a8aa15362d
A wide range of people, including accompanied wheelchair users, should be able to access and use the lift.
A wide range of people , including accompanied wheelchair users , should be able to access and use the lift .
O B-quality I-quality O B-object O O B-object I-object I-object O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '49_UK_DocM_V1_AccessAndUseOfBuildings'}
263dec16-c53e-4169-91d3-b6961fcda501
The water system shall be leakproof.
The water system shall be leakproof .
O B-object I-object O O B-quality O
{'ID': '84_Finnish_Health-WaterAndSewerage'}
8b9e1d32-efa8-409b-873b-22e2eae5b537
External walls and their various layers must form a whole that prevents water from harmfully penetrating into the structures.
External walls and their various layers must form a whole that prevents water from harmfully penetrating into the structures .
B-quality B-object O O O B-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '95_Finnish_Health-Humidity'}
759d26ff-821f-4949-9096-a7e15c5580f6
Windows and doors: should be installed in such a way that the thermal integrity of the insulated plane is maintained.
Windows and doors : should be installed in such a way that the thermal integrity of the insulated plane is maintained .
B-object O B-object O O O B-quality O O O O O O B-property I-property O O B-object I-object O B-property O
{'ID': '137_UK_DocL_V1_ConsrvationOfFuelAndPower'}
6a553c19-481f-4947-9047-fd2c4d0daa44
Any floors, walls and doors that have been installed to allow the potential liftway to be used as storage or for other purposes could be easily removed without structural alteration.
Any floors , walls and doors that have been installed to allow the potential liftway to be used as storage or for other purposes could be easily removed without structural alteration .
O B-object O B-object O B-object O O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O O B-quality I-quality I-quality I-quality I-quality O
{'ID': '83_UK_DocM_V1_AccessAndUseOfBuildings'}
9c9a27b6-b4be-4946-854a-c46ee812140c
In general, accessible bedrooms should be no less advantageously situated than other bedrooms.
In general , accessible bedrooms should be no less advantageously situated than other bedrooms .
O O O B-quality B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '142_UK_DocM_V2_AccessAndUseOfBuildings'}
6594919a-cde6-4dd8-be04-eb61e30f99bb
Snow or rain-water shall not be allowed to ingress the ventilation system via externally mounted air transfer devices in quantities causing damage to the system, lowering air quality or impairing the functioning of the system.
Snow or rain-water shall not be allowed to ingress the ventilation system via externally mounted air transfer devices in quantities causing damage to the system , lowering air quality or impairing the functioning of the system .
B-object O B-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '67_Finnish_Health-IndoorClimateAndVentilation'}
e46efdc3-02a8-4440-870d-a6cdc1b34430
NOTE: Rooms that are designed to contain printers and photocopiers in substantial use (more than 30 minutes per hour) should not be designed to be occupied.
NOTE : Rooms that are designed to contain printers and photocopiers in substantial use ( more than 30 minutes per hour ) should not be designed to be occupied .
O O B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O B-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '44_UK_DocF_V2_Ventilation'}
28433761-e537-456b-9ff8-00e786b43143
Consumer units should be mounted so that the switches are between 1350mm and 1450mm above floor level.
Consumer units should be mounted so that the switches are between 1350mm and 1450mm above floor level .
B-object I-object O O B-quality O O O B-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '126_UK_DocM_V1_AccessAndUseOfBuildings'}
4abb3268-3ba6-47e8-a8b7-4676dbaa9a16
For buildings other than dwellings and for common access areas in buildings that contain flats, Provide all means of escape routes with a minimum clear headroom of 2m, except in doorways.
For buildings other than dwellings and for common access areas in buildings that contain flats , Provide all means of escape routes with a minimum clear headroom of 2m , except in doorways .
O B-object B-quality I-quality I-quality O O B-quality B-object I-object O B-object B-quality I-quality I-quality O O B-quality B-property O B-object I-object O O B-quality B-quality B-property O B-value O B-quality I-quality I-quality O
{'ID': '28_UK_DocK_ProtectionFromFalling'}
bd033057-ac6c-45bb-92c7-ca58bf22dab1
The lobby should be large enough and of a shape to allow a wheelchair user or a person pushing a pram to move clear of one door before opening the second door.
The lobby should be large enough and of a shape to allow a wheelchair user or a person pushing a pram to move clear of one door before opening the second door .
O B-object O O B-quality I-quality O O O B-property B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '80_UK_DocM_V2_AccessAndUseOfBuildings'}
8421f806-70f2-46a9-a308-90a40da3541d
Where the gradient of the approach, whether over its whole length or in part, is 1:20 or steeper, that part of the approach should be designed as ramped access.
Where the gradient of the approach , whether over its whole length or in part , is 1:20 or steeper , that part of the approach should be designed as ramped access .
O O B-property O O B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O O B-value O O O B-object I-object O O B-object O O B-quality I-quality I-quality I-quality O
{'ID': '41_UK_DocM_V2_AccessAndUseOfBuildings'}
0edb92b7-a2e1-480f-b708-e7e6c9951a79
The foundation drainage water shall flow away from the property in such a way that it does not cause problems to the waste water and storm water systems.
The foundation drainage water shall flow away from the property in such a way that it does not cause problems to the waste water and storm water systems .
O B-object B-object I-object O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '173_Finnish_Health-WaterAndSewerage'}
5e7d4831-4ec8-48f9-9e60-0422fcc1eae4
When replacing an existing system, the installed generation capacity of the new system should be no less than that of the existing system, except where a smaller system can be demonstrated to be more appropriate or effective (e.g. replacing an existing system with one which is better matched to the dwelling's energy demand).
When replacing an existing system , the installed generation capacity of the new system should be no less than that of the existing system , except where a smaller system can be demonstrated to be more appropriate or effective ( e.g . replacing an existing system with one which is better matched to the dwelling 's energy demand ) .
O B-quality O B-quality B-object O O B-property I-property I-property O O B-quality B-object O O O O O B-property O O B-quality B-object O O O O B-quality B-object O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality O O O O O O O O O O O O O O O O O O O O O
{'ID': '344_UK_DocL_V1_ConsrvationOfFuelAndPower'}
493ec553-7761-4d1e-aa98-05d925ddf955
The opening of a horizontal hatch must be at least 600 x 600 millimetres.
The opening of a horizontal hatch must be at least 600 x 600 millimetres .
O B-property O O B-quality B-object O O O O B-value I-value I-value I-value O
{'ID': '84_Finnish_SafetyOfUse'}
03bdab65-fc14-4101-add9-f26c25f41e82
A drainage point shall be equipped with a cleansable water seal.
A drainage point shall be equipped with a cleansable water seal .
O B-object I-object O O O O O B-quality B-object I-object O
{'ID': '134_Finnish_Health-WaterAndSewerage'}
77f993c6-dff1-4f9a-8f66-73221d3cbaff
If the dwelling only has one habitable room, a minimum ventilation rate of 13l/s should be used.
If the dwelling only has one habitable room , a minimum ventilation rate of 13l/s should be used .
O O B-object O O B-value B-object I-object O O O B-property I-property O B-value O O O O
{'ID': '43_UK_DocF_V1_Ventilation'}
0cfe8c0e-45e4-4c4c-bf9b-906e26e28c75
There should be sufficient space for people to approach the building, pass others who are travelling in the opposite direction and carry out all necessary manoeuvres.
There should be sufficient space for people to approach the building , pass others who are travelling in the opposite direction and carry out all necessary manoeuvres .
O O O B-quality B-object O B-object O B-quality I-quality I-quality O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O B-quality I-quality I-quality I-quality I-quality O
{'ID': '43_UK_DocM_V2_AccessAndUseOfBuildings'}
8e83d841-dcab-479c-a131-a5ce80cd416d
The fan speed should be set to achieve the desired continuous flow rate.
The fan speed should be set to achieve the desired continuous flow rate .
O B-object B-property O O B-quality I-quality I-quality I-quality I-quality I-quality I-quality I-quality O
{'ID': '197_UK_DocF_V1_Ventilation'}
e505b13c-7b62-4857-aa2d-544dc986e9c0
For dwellings, for external tapered steps and stairs that are part of the building the going of each step should be a minimum of 280mm.
For dwellings , for external tapered steps and stairs that are part of the building the going of each step should be a minimum of 280mm .
O B-object O O B-quality B-quality B-property O B-property B-quality I-quality I-quality I-quality I-quality I-quality O B-property O B-quality B-property O O O O O B-value O
{'ID': '18_UK_DocK_ProtectionFromFalling'}
78a7dc3d-5e1e-4858-8913-b319e30f2ff1
The air extract rate should be 20 litres per second per machine during use.
The air extract rate should be 20 litres per second per machine during use .
O B-property I-property I-property O O B-value I-value I-value I-value O B-object B-quality I-quality O
{'ID': '46_UK_DocF_V2_Ventilation'}