ICSA-23-348-09 | Siemens Simantic S7-1500 CPU family | Affected devices improperly handle specially crafted packets sent to port 102/tcp.
This could allow an attacker to create a denial of service condition. A restart is needed to restore
normal operations. | [] | null | 7.5 | null | null |
ICSA-24-123-02 | Delta Electronics DIAEnergie | Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the script Handler_CFG.ashx. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed. Delta Electronics DIAEnergie is vulnerable to an SQL injection vulnerability that exists in the GetDIACloudList endpoint. An authenticated attacker can exploit this issue to potentially compromise the system on which DIAEnergie is deployed. Delta Electronics DIAEnergie has insufficient input validation which makes it possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten. | [] | null | 8.8 | null | null |
ICSA-17-192-01 | Siemens SIMATIC Logon | Specially crafted packets sent to the SIMATIC Logon Remote Access service on Port 16389/TCP could cause a denial-of-service condition. The service restarts automatically.CVE-2017-9938 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). | [] | null | null | 5.3 | null |
ICSA-23-059-01 | Hitachi Energy Gateway Station | A NULL pointer dereference was found in affected versions of OpenLDAP. An unauthenticated attacker could remotely crash the slapd process by sending a specially crafted request, causing a denial-of-service condition on the user authentication function. CVE-2020-25692 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). A vulnerability exists in the OpenSSL’s BN_mod_sqrt() function, which computes a modular square root containing a bug that can cause it to loop forever for non-prime moduli. Internally, this function is used when parsing certificates containing elliptic curve public keys in compressed form or explicit elliptic curve parameters with a base point encoded in compressed form. Successful exploitation may cause a denial-of-service condition. CVE-2022-0778 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-20-343-06 | Siemens XHQ Operations Intelligence | The application's web server could expose non-sensitive information about the server's architecture. This could allow an attacker to adapt further attacks to the version in place. The web interface could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify content of particular web pages, causing the application to behave in unexpected ways for legitimate users. The web interface could allow injections that could lead to XSS attacks if unsuspecting users are tricked into accessing a malicious link. The web interface could allow SQL injection attacks if an attacker is able to modify content of particular web pages. The web interface could allow attackers to traverse through the file system of the server based by sending specially crafted packets over the network without authentication. The web interface could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. | [] | null | 8.1 | null | null |
ICSA-25-007-02 | Nedap Librix Ecoreader | The affected product is missing authentication for critical functions that could allow an unauthenticated attacker to potentially execute malicious code. | [] | null | 8.6 | null | null |
ICSA-24-081-01 | Advantech WebAccess/SCADA | There is a SQL Injection vulnerability in Advantech's WebAccess/SCDA software that allows an authenticated attacker to remotely inject SQL code on the database. Successful exploitation of this vulnerability could allow an attacker to read or modify data on the remote database. | [] | null | 6.4 | null | null |
ICSA-19-141-01 | Computrols CBAS Web | Users can perform certain actions via HTTP requests without performing any validity checks, which may allow unauthorized actions with administrative privileges if a logged-in user visits a malicious website.CVE-2019-10847 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L). The application suffers from a username enumeration weakness. The device behaves differently or sends different responses in a way that may expose security-relevant information about the state of the product.CVE-2019-10848 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). Specific parameters passed to scripts is not sanitized before being returned to the user, which may allow an attacker to execute arbitrary code in a user 's browser session in context of an affected site.CVE-2019-10846 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N). The application incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component, which could allow attackers to execute commands directly on the operating system.CVE-2019-10854 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The application has an unprotected subversion directory, which may allow an attacker to download the entire firmware codebase and discover sensitive information about the inner workings of the underlying OS.CVE-2019-10849 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). Several scripts contain a hard-coded encryption key for database backup file decryption, which may allow an authenticated attacker to gain access to the full database of the device and discover sensitive information.CVE-2019-10851 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N). Improper validation of parameters passed to different scripts may allow a remote authenticated attacker to execute arbitrary SQL commands in the application 's database.CVE-2019-10852 has been assigned to this vulnerability. A CVSS v3 base score of 6.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L). Sending specific parameters to a function will enable the auth flag, which may allow an unauthenticated attacker to bypass authentication and gain full control of the device.CVE-2019-10853 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The application stores the passwords in the database using the MD5 hash. The MD5 algorithm is vulnerable to known cryptographic attacks, which may allow discovery of passwords.CVE-2019-10855 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). | [] | null | null | 5.3 | null |
ICSA-20-303-01 | Mitsubishi Electric MELSEC iQ-R, Q, and L Series (Update D) | Mitsubishi Electric MELSEC iQ-R, Q, and L Series CPU modules are vulnerable to uncontrolled resource consumption. When the CPU module receives a specially crafted packet from a malicious attacker, Ethernet communication may enter a denial-of-service condition and a reset is required to recover it. | [] | null | 7.5 | null | null |
ICSA-23-206-02 | Rockwell Automation ThinManager ThinServer | An executable used in the affected products can be configured to enable an API feature in the HTTPS server settings. This feature is disabled by default. When the API is enabled and handling requests, a path traversal vulnerability exists that could allow a remote actor to leverage the server's file system privileges and read arbitrary files stored in it. A malicious user could exploit this vulnerability by executing a path that contains manipulating variables. | [] | null | null | 7.5 | null |
ICSA-23-026-04 | Sierra Wireless AirLink Router with ALEOS Software | AirLink router versions with ALEOS software are vulnerable when users with valid ACEManager credentials and access to the ACEManager interface could manipulate the IP logging operation to execute arbitrary shell commands on the device.-CVE-2022-46649 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). AirLink router versions with ALEOS software are vulnerable when users with valid ACEManager credentials and access to the ACEManager interface could reconfigure the device to expose the ACEManager credentials on the pre-login status page.-CVE-2022-46650 has been assigned to this vulnerability. A CVSS v3 base score of 4.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:N/A:N). | [] | null | null | 4.5 | null |
ICSA-23-040-03 | Johnson Controls System Configuration Tool (SCT) | System Configuration Tool (SCT) versions 14 and 15 are vulnerable during a cross-site scripting attack. This could allow an attacker to access cookies and take control of an affected system.-CVE-2022-21939 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H). System Configuration Tool (SCT) versions 14 and 15 are vulnerable during a cross-site scripting attack. This could allow an attacker to access cookies and take control of an affected system.-CVE-2022-21940 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.5 | null |
ICSMA-17-227-01 | ICSMA-17-227-01_BMC Medical and 3B Medical Luna CPAP Machine | An improper input validation vulnerability has been identified, which may allow an authenticated attacker to crash the CPAP 's Wi-Fi module resulting in a denial-of-service condition. | [] | null | null | 4.6 | null |
ICSA-22-242-01 | Hitachi Energy FACTS Control Platform (FCP) Product | Hitachi Energy is aware of public reports of multiple vulnerabilities in open-source software components (OpenSSL and Node.JS) used in the FACTS Control Platform (FCP) product. Versions are available to remediate the identified vulnerabilities.CVE-2020-1968, CVE-2020-8172, CVE-2020-8174, CVE-2020-8201, CVE-2020-8252, CVE-2020-8265, and CVE-2020-8287 have been assigned to these vulnerabilities in open-source components used by FCP. A CVSS v3 base score of 8.1 has been calculated for the worst case; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.1 | null |
ICSA-17-150-01 | Automated Logic Corporation ALC WebCTRL, Liebert SiteScan, Carrier i-VU | An attacker could enter malicious input to WebCTRL, i-Vu, or SiteScan Web through a weakly configured XML parser causing the application to execute arbitrary code or disclose file contents from a server or connected network.CVE-2016-5795 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:L). | [] | null | null | 6.5 | null |
ICSA-22-347-03 | Contec CONPROSYS HMI System (CHS) | CONPROSYS HMI System versions 3.4.4 and prior are vulnerable to an OS Command Injection, which could allow an unauthenticated remote attacker to send specially crafted requests that could execute commands on the server. CVE-2022-44456 has been assigned to this vulnerability. A CVSS v3 base score of 10.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H). In CONPROSYS HMI System Ver.3.4.5 and prior, user credential information could be altered by a remote unauthenticated attacker. CVE-2023-22331 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). In CONPROSYS HMI System Ver.3.4.5 and prior, user credentials could be obtained via a machine-in-the-middle attack. CVE-2023-22334 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N). In CONPROSYS HMI System Ver.3.4.5 and prior, an arbitrary script could be executed on the web browser of the administrative user logging into the product. This could result in sensitive information being obtained. CVE-2023-22373 has been assigned to this vulnerability. A CVSS v3 base score of 5.7 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:N). In CONPROSYS HMI System Ver.3.4.5 and prior, a remote unauthenticated attacker could obtain the server certificate, including the private key of the product. CVE-2023-22339 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 7.5 | null |
ICSA-24-165-17 | Rockwell Automation FactoryTalk View SE | A privilege escalation vulnerability exists in FactoryTalk View SE. The vulnerability allows low-privilege users to edit scripts, bypassing Access Control Lists, and potentially gaining further access within the system. | [] | null | 7.8 | null | null |
ICSA-21-168-03 | Advantech WebAccess/SCADA (Update A) | The affected product is vulnerable to redirection, which may allow an attacker to send a maliciously crafted URL that could result in redirecting a user to a malicious webpage.CVE-2021-32956 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). The affected product is vulnerable to a directory traversal, which may allow an attacker to remotely read arbitrary files on the file system.CVE-2021-32954 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 6.5 | null |
ICSA-17-353-05 | WECON Technology Co., Ltd. LeviStudio HMI Editor | The heap-based buffer overflow vulnerability has been identified, which may allow remote code execution.CVE-2017-16717 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). | [] | null | null | 7.3 | null |
ICSA-18-254-02 | Fuji Electric V-Server Lite | A maliciously crafted project file may cause a buffer overflow, which may allow the attacker to execute arbitrary code.CVE-2018-10637 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-21-042-02 | Rockwell Automation DriveTools SP and Drives AOP | DriveTools and Drives AOP both contain a vulnerability that a local attacker with limited privileges may be able to exploit resulting in privilege escalation and complete control of the system.CVE-2021-22665 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:R/S:C/C:H/I:H/A:H). | [] | null | null | 7.5 | null |
ICSA-21-056-04 | ProSoft Technology ICX35 | Changing the password on the module webpage does not require the user to type in the current password first. Thus, the password could be changed by a user or external process without knowledge of the current password.CVE-2021-22661 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L). | [] | null | null | 8.2 | null |
ICSA-21-189-01 | Rockwell Automation MicroLogix 1100 | A remote, unauthenticated attacker sending specially crafted commands could cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault when the controller is switched to RUN mode.CVE-2021-33012 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H). | [] | null | null | 8.6 | null |
ICSMA-18-107-01 | Abbott Laboratories Defibrillator | The device 's authentication algorithm, which involves an authentication key and time stamp, can be compromised or bypassed, which may allow a nearby attacker to issue unauthorized commands to the ICD or CRT-D via RF communications.CVE-2017-12712 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The ICDs and CRT-Ds do not restrict or limit the number of correctly formatted RF wake-up commands that can be received, which may allow a nearby attacker to repeatedly send commands to reduce device battery life. CVE-2017-12714 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H).. Abbott is a U.S.-based company headquartered in Abbott Park, Illinois. Abbott is a U.S.-based company headquartered in Abbott Park, Illinois.. The affected ICDs and CRT-Ds are implantable medical devices designed to deliver high voltage electrical pulses to correct a fast or irregular heartbeat. According to Abbott, these devices are deployed across the healthcare and public health sector. Abbott indicates that these products are used worldwide.CVE-2017-12714 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 5.3 | null |
ICSA-17-117-01B | GE Multilin SR, UR, and URplus Protective Relays (Update B) | Cipher text versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Cipher text of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.CVE-2017-7905 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.1 | null |
ICSA-22-195-13 | Siemens Mendix | In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords. | [] | null | 4.9 | null | null |
ICSA-23-194-06 | Honeywell Experion PKS, LX and PlantCruise | Experion Server or Console Station could experience a denial-of-service condition due to a heap overflow during the handling of a specially crafted message for a specific configuration operation. Experion Server or Console Station could experience a denial-of-service condition or remote code execution due to a stack overflow during the handling of a specially crafted message for a specific configuration operation. C300 could leak configuration data when an error is generated in response to a specially crafted message. C300 could experience a denial-of-service condition due to a buffer overflow in the handling of a specially crafted message received by the controller. C300 could experience a denial-of-service condition due to a stack overflow when decoding a message from the server. C300 could experience a denial-of-service condition due to a buffer overflow when an error is generated in response to a specially crafted message. C300 may be loaded with malicious firmware which could enable remote code execution. Experion Server may experience a denial-of-service condition due to an incorrect comparison when handling a specially crafted message. Experion Server may experience a denial-of-service condition due to a heap overflow which could occur when handling a specially crafted message. | [] | null | null | 9.8 | null |
ICSMA-17-017-02 | BD Alaris 8015 PC Unit (Update B) | An unauthorized user with physical access to an Alaris 8015 PC unit may be able to obtain unencrypted wireless network authentication credentials and other sensitive technical data by removing the external Wi-Fi card from an Alaris 8015 PC unit and connecting a pre-programmed malicious CF (CompactFlash) card to perform the attack.CVE-2016-8375 has been assigned to this vulnerability. A CVSS v3 base score of 4.9 has been calculated; the CVSS vector string is (AV:P/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N). An unauthorized user with physical access to an Alaris 8015 PC unit may be able to disassemble the device to access the removable flash memory, allowing read-and-write access to device memory. Physical access to the CF card allows an attacker to overwrite application and internal data (logs, drug library, etc.). Older software versions of the Alaris 8015 PC unit (Version 9.5 and prior) store wireless network authentication credentials and other sensitive technical data on the affected device 's removable flash memory. It is not difficult to obtain this data, but very difficult to interpret and change it to create an exploit that is progressive. In addition, the proprietary nature of the stored data format makes it unlikely modification of the CF card would go undetected.CVE-2016-9355 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 6.8 | null |
ICSA-22-286-03 | Siemens Solid Edge | The affected application contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted DWG files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17627) | [] | null | 7.8 | null | null |
ICSA-20-289-01 | Advantech WebAccess/SCADA | The WADashboard component of WebAccess/SCADA may allow an attacker to control or influence a path used in an operation on the filesystem and remotely execute code as an administrator.CVE-2020-25161 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.8 | null |
ICSA-24-226-06 | Rockwell Automation FactoryTalk View Site Edition | A code execution vulnerability exists in the affected product. The vulnerability occurs due to improper default file permissions allowing any user to edit or replace files, which are executed by account with elevated permissions. | [] | null | 8.8 | null | null |
ICSA-18-158-01 | Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway | An unquoted search path or element may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.CVE-2018-10619 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). | [] | null | null | 8.8 | null |
ICSA-18-317-04 | Siemens SCALANCE S | The integrated web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user must be logged into the web interface in order for the exploitation to succeed. At the stage of publishing this security advisory no public exploitation is known. | [] | null | null | 4.7 | null |
ICSA-23-101-01 | FANUC ROBOGUIDE-HandlingPRO | FANUC ROBOGUIDE-HandlingPRO Versions 9 Rev.ZD and prior is vulnerable to a path traversal, which could allow an attacker to remotely read files on the system running the affected software. CVE-2023-1864 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N). | [] | null | null | 6.8 | null |
ICSA-19-192-03 | Siemens TIA Administrator (TIA Portal) | The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | [] | null | null | 8 | null |
ICSA-18-144-01 | Schneider Electric Floating License Manager | OpenSSL incorrectly uses pointer arithmetic for heap-buffer boundary checks, which may allow denial of service attacks or other unspecified behavior.CVE-2016-2177 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). This vulnerability can be exploited to cause an out-of-bounds memory read access, which may allow remote code execution with system privileges.CVE-2016-10395 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). An open redirect vulnerability has been identified, which may allow remote attackers to redirect users to arbitrary websites for phishing attacks.CVE-2017-5571 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). | [] | null | null | 6.1 | null |
ICSA-23-348-02 | Johnson Controls Kantech Gen1 ioSmart | Kantech Gen1 ioSmart card readers with firmware versions prior to 1.7.2 do not properly release memory after its effective lifetime. An attacker with physical access to the Kantech Gen1 ioSmart card reader in certain circumstances can recover the reader's communication memory between the card and reader. CWE-200: Exposure of Sensitive Information to an Unauthorized Actor also applies to this vulnerability. | [] | null | 7.5 | null | null |
ICSA-22-249-02 | AVEVA Edge 2020 R2 SP1 and all prior versions | The scripting capability provided by AVEVA Edge is unrestricted; a user could abuse this to achieve arbitrary code execution.CVE-2022-36970 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A vulnerability exists in AVEVA Edge that could allow a malicious actor with access to the file system to achieve arbitrary code execution and cause escalation by tricking AVEVA Edge into loading an unsafe DLL.CVE-2022-28686 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists in AVEVA Edge that could allow a malicious actor with access to the file system to achieve arbitrary code execution and cause escalation by tricking AVEVA Edge into loading an unsafe DLL.CVE-2022-28687 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists in AVEVA Edge that could allow a malicious actor with access to the file system to achieve arbitrary code execution and cause escalation by tricking AVEVA Edge into loading an unsafe DLL.CVE-2022-28688 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists in AVEVA Edge that, if exploited, could allow a user to tamper with project files to achieve arbitrary code execution.CVE-2022-28685has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). This vulnerability, if exploited, could allow a malicious actor to cause a denial-of-service condition in AVEVA Edge or to extract arbitrary files from the host running AVEVA Edge.CVE-2022-36969 has been assigned to this vulnerability. A CVSS v3 base score of 6.6 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:N/A:H). | [] | null | null | 6.6 | null |
ICSA-18-352-05 | Siemens TIM 1531 IRC Modules | The device was missing proper authentication on port 102/tcp, although configured. Successful exploitation requires an attacker to be able to send packets to port 102/tcp of the affected device. No user interaction and no user privileges are required to exploit the vulnerability. At the time of advisory publication no public exploitation of this vulnerability was known. | [] | null | 10 | null | null |
ICSA-22-356-04 | Omron CX-Programmer | CX-Programmer is vulnerable to a Out-of-bounds Write when a user opens a specially crafted CXP file. This could cause a loss of sensitive information or arbitrary code execution.CVE-2022-43509 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSMA-18-156-01 | Philips' IntelliVue Patient and Avalon Fetal Monitors | The vulnerability allows an unauthenticated attacker to access memory (write-what-where) from an attacker-chosen device address within the same subnet.CVE-2018-10597 has been assigned to this vulnerability. A CVSS v3 base score of 8.3 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H). The vulnerability allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.CVE-2018-10599 has been assigned to this vulnerability. A CVSS v3 base score of 6.4 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L). The vulnerability exposes an echo service, in which an attacker-sent buffer to an attacker-chosen device address within the same subnet is copied to the stack with no boundary checks, hence resulting in stack overflow.CVE-2018-10601 has been assigned to this vulnerability. A CVSS v3 base score of 8.2 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:C/C:H/I:L/A:H). | [] | null | null | 8.2 | null |
ICSA-22-195-15 | Siemens SIMATIC eaSie Core Package | The affected systems do not properly validate input that is sent to the underlying message passing framework. This could allow a remote attacker to trigger a denial of service of the affected system. The underlying MQTT service of affected systems does not perform authentication in the default configuration. This could allow an unauthenticated remote attacker to send arbitrary messages to the service and thereby issue arbitrary requests in the affected system. | [] | null | 10 | null | null |
ICSA-21-252-03 | Mitsubishi Electric Europe B.V. smartRTU and INEA ME-RTU | The affected product allows an attacker to execute arbitrary commands due to the passing of unsafe user supplied data to the system shell.CVE-2019-14931 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). It is possible to download the affected product 's configuration file, which contains sensitive data, through the URL.CVE-2019-14927 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The affected product 's web configuration software allows an authenticated user to inject malicious data into the application that can then be executed in a victim 's browser, allowing stored cross-site scripting.CVE-2019-14928 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N). Hard-coded SSH keys have been identified in the affected product 's firmware. As the secure keys cannot be regenerated by a user and are not regenerated on firmware updates, all deployed affected products utilize the same SSH keys.CVE-2019-14926 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected products contain undocumented user accounts with hard-coded password credentials. An attacker could exploit this vulnerability by using the accounts to login to affected RTU 's.CVE-2019-14930 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected products store password credentials in plain text in a configuration file. An unauthenticated user can obtain the exposed password credentials to gain access to the specific services.CVE-2019-14929 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected products store and reads configuration settings from a file that has insecure world-readable permissions assigned. This could allow all users on the system to read the configuration file containing usernames and plain text password combinations, as well as other sensitive configuration information of the RTU.CVE-2019-14925 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 6.5 | null |
ICSA-20-105-03 | Triangle MicroWorks SCADA Data Gateway | This vulnerability allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.CVE-2020-10615 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). This vulnerability allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.CVE-2020-10613 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N). This vulnerability allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.CVE-2020-10611 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSMA-21-175-01 | Philips Interoperability Solution XDS | The affected product is vulnerable to clear text transmission of sensitive information when configured to use LDAP via TLS and where the domain controller returns LDAP referrals, which may allow an attacker to remotely read LDAP system credentials.CVE-2021-32966 has been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N). | [] | null | null | 3.7 | null |
ICSA-24-354-03 | Delta Electronics DTM Soft | The affected product deserializes objects, which could allow an attacker to execute arbitrary code. | [] | null | 7.8 | null | null |
ICSA-18-352-01 | ABB GATE-E2 | These devices do not allow authentication to be configured on administrative telnet or web interfaces, which could enable various effects vectors, including conducting device resets, reading or modifying registers, and changing configuration settings such as IP addresses.CVE-2018-18995 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). Using the administrative web interface, an unauthenticated attacker can insert an HTML/Javascript payload into any of the device properties, which may allow an attacker to display/execute the payload in a visitor browser.CVE-2018-18997 has been assigned to this vulnerability. A CVSS v3 base score of 7.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L). | [] | null | null | 7.1 | null |
ICSA-23-193-01 | Rockwell Automation Select Communication Modules | Where this vulnerability exists in the 1756 EN2* and 1756 EN3* products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device. Where this vulnerability exists in the 1756-EN4* products, it could allow a malicious user to cause a denial-of-service condition by asserting the target system through maliciously crafted CIP messages. | [] | null | null | 7.5 | null |
ICSA-21-208-01 | KUKA KR C4 | An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials.CVE-2021-33016 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An attacker can gain VxWorks Shell after login due to hard-coded credentials.CVE-2021-33014 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.8 | null |
ICSA-22-277-01 | Johnson Controls Metasys ADX Server | The affected product software does not prove or insufficiently validates user identity claims.CVE-2022-21936 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H). | [] | null | null | 8.1 | null |
ICSA-23-033-05 | Delta Electronics DX-2100-L1-CN | The web configuration service of the affected device contains an authenticated command injection vulnerability. It can be used to execute system commands on the operating system (OS) from the device in the context of the user "root." If the attacker has credentials for the web service, then the device could be fully compromised.CVE-2022-42140 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The affected device contains a stored cross-site scripting vulnerability in the "net diagnosis" function in the web configuration service. This can be exploited in the context of a victim's session. An attacker could deliver a large variety of payloads that could lead to possibilities, such as remote code execution.-CVE-2023-0432 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H). | [] | null | 9 | null | null |
ICSA-23-075-04 | Siemens SCALANCE W1750D Devices | A timing based side channel exists in the OpenSSL RSA Decryption implementation which could be sufficient to recover a plaintext across a network in a Bleichenbacher style attack. To achieve a successful decryption an attacker would have to be able to send a very large number of trial messages for decryption. The vulnerability affects all RSA padding modes: PKCS#1 v1.5, RSA-OEAP and RSASVE. For example, in a TLS connection, RSA is commonly used by a client to send an encrypted pre-master secret to the server. An attacker that had observed a genuine connection between a client and a server could use this flaw to send trial messages to the server and record the time taken to process them. After a sufficiently large number of messages the attacker could recover the pre-master secret used for the original connection and thus be able to decrypt the application data sent over that connection. The function PEM_read_bio_ex() reads a PEM file from a BIO and parses and decodes the "name" (e.g. "CERTIFICATE"), any header data and the payload data. If the function succeeds then the "name_out", "header" and "data" arguments are populated with pointers to buffers containing the relevant decoded data. The caller is responsible for freeing those buffers. It is possible to construct a PEM file that results in 0 bytes of payload data. In this case PEM_read_bio_ex() will return a failure code but will populate the header argument with a pointer to a buffer that has already been freed. If the caller also frees this buffer then a double free will occur. This will most likely lead to a crash. This could be exploited by an attacker who has the ability to supply malicious PEM files for parsing to achieve a denial of service attack. The functions PEM_read_bio() and PEM_read() are simple wrappers around PEM_read_bio_ex() and therefore these functions are also directly affected. These functions are also called indirectly by a number of other OpenSSL functions including PEM_X509_INFO_read_bio_ex() and SSL_CTX_use_serverinfo_file() which are also vulnerable. Some OpenSSL internal uses of these functions are not vulnerable because the caller does not free the header argument if PEM_read_bio_ex() returns a failure code. These locations include the PEM_read_bio_TYPE() functions as well as the decoders introduced in OpenSSL 3.0. The OpenSSL asn1parse command line application is also impacted by this issue. The public API function BIO_new_NDEF is a helper function used for streaming ASN.1 data via a BIO. It is primarily used internally to OpenSSL to support the SMIME, CMS and PKCS7 streaming capabilities, but may also be called directly by end user applications. The function receives a BIO from the caller, prepends a new BIO_f_asn1 filter BIO onto the front of it to form a BIO chain, and then returns the new head of the BIO chain to the caller. Under certain conditions, for example if a CMS recipient public key is invalid, the new filter BIO is freed and the function returns a NULL result indicating a failure. However, in this case, the BIO chain is not properly cleaned up and the BIO passed by the caller still retains internal pointers to the previously freed filter BIO. If the caller then goes on to call BIO_pop() on the BIO then a use-after-free will occur. This will most likely result in a crash. This scenario occurs directly in the internal function B64_write_ASN1() which may cause BIO_new_NDEF() to be called and will subsequently call BIO_pop() on the BIO. This internal function is in turn called by the public API functions PEM_write_bio_ASN1_stream, PEM_write_bio_CMS_stream, PEM_write_bio_PKCS7_stream, SMIME_write_ASN1, SMIME_write_CMS and SMIME_write_PKCS7. Other public API functions that may be impacted by this include i2d_ASN1_bio_stream, BIO_new_CMS, BIO_new_PKCS7, i2d_CMS_bio_stream and i2d_PKCS7_bio_stream. The OpenSSL cms and smime command line applications are similarly affected. There is a type confusion vulnerability relating to X.400 address processing inside an X.509 GeneralName. X.400 addresses were parsed as an ASN1_STRING but the public structure definition for GENERAL_NAME incorrectly specified the type of the x400Address field as ASN1_TYPE. This field is subsequently interpreted by the OpenSSL function GENERAL_NAME_cmp as an ASN1_TYPE rather than an ASN1_STRING. When CRL checking is enabled (i.e. the application sets the X509_V_FLAG_CRL_CHECK flag), this vulnerability may allow an attacker to pass arbitrary pointers to a memcmp call, enabling them to read memory contents or enact a denial of service. In most cases, the attack requires the attacker to provide both the certificate chain and CRL, neither of which need to have a valid signature. If the attacker only controls one of these inputs, the other input must already contain an X.400 address as a CRL distribution point, which is uncommon. As such, this vulnerability is most likely to only affect applications which have implemented their own functionality for retrieving CRLs over a network. | [] | null | 7.4 | null | null |
ICSA-23-208-03 | Mitsubishi Electric CNC Series (Update E) | In Mitsubishi Electric CNC series devices, a malicious remote attacker could cause a denial-of-service condition and execute malicious code by sending specially crafted packets. | [] | null | null | 9.8 | null |
ICSA-21-287-06 | Siemens Solid Edge | The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process. The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations. The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.
An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files.
An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13703). The affected application contains a use-after-free vulnerability while parsing OBJ files.
An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13771). The affected application contains a use-after-free vulnerability while parsing OBJ files.
An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13778). The affected application contains a use-after-free vulnerability while parsing OBJ files.
An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13789). The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files.
An attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770). The affected application contains a use-after-free vulnerability while parsing OBJ files.
An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13773). The affected application contains a use-after-free vulnerability while parsing OBJ files.
An attacker could leverage this vulnerability to execute code in the context of the current process (ZDI-CAN-13776). | [] | null | 7.8 | null | null |
ICSA-23-215-02 | Mitsubishi Electric GT and GOT Series Products | Information disclosure vulnerability exists in the Data Transfer Security function on GT Designer3, GOT2000 Series, GOT SIMPLE Series and GT SoftGOT2000. This vulnerability allows an attacker to obtain plaintext passwords by sniffing packets containing encrypted passwords and decrypting the encrypted passwords. | [] | null | null | 7.5 | null |
ICSA-23-096-06 | mySCADA myPRO | mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands. CVE-2023-28400 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands. CVE-2023-28716 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands. CVE-2023-28384 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands. CVE-2023-29169 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands. CVE-2023-29150 has been assigned to this vulnerability. A CVSS v3 base score of 9.9 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). | [] | null | null | 9.9 | null |
ICSA-22-223-03 | Schneider Electric EcoStruxure, EcoStruxure Process Expert, SCADAPack RemoteConnect for x70 | A memory corruption vulnerability exists in the XML-parsing ParseAttribs functionality of AT&T Labs ' Xmill 0.7. A specially crafted XML file can lead to a heap buffer overflow. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21810 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A heap-based buffer overflow vulnerability exists in the XML Decompression. PlainTextUncompressor::UncompressItem functionality of AT&T Labs ' Xmill 0.7. A specially crafted XMI file could lead to remote code execution. An attacker could provide a malicious file to trigger this vulnerability.CVE-2021-21825 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A heap-based buffer overflow vulnerability exists in the XML Decompression EnumerationUncompressor::UncompressItem functionality of AT&T Labs ' Xmill 0.7. A specially crafted XMI file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21829 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A heap-based buffer overflow vulnerability exists in the XML Decompression LabelDict::Load functionality of AT&T Labs ' Xmill 0.7. A specially crafted XML file can lead to remote code execution. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21830 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A memory corruption vulnerability exists in the XML-parsing CreateLabelOrAttrib functionality of AT&T Labs ' Xmill 0.7. The product subtracts one value from another such that the result is less than the minimum allowable integer value, which produces a value not equal to the correct result. CVE-2021-21811 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT&T Labs ' Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a static sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger these vulnerabilities.CVE-2021-21812 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). Within the function HandleFileArg, the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to memcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow.CVE-2021-21813 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strlen to determine the ending location of the char* passed in by the user, no checks are done to see if the passed in char* is longer than the staticly sized buffer data is memcpy-d into, but after the memcpy a null byte is written to what is assumed to be the end of the buffer to terminate the char*, but without length checks, this null write occurs at an arbitrary offset from the buffer. An attacker can provide malicious input to trigger this vulnerability.CVE-2021-21814 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A stack-based buffer overflow vulnerability exists in the command-line-parsing HandleFileArg functionality of AT&T Labs' Xmill 0.7. Within the function HandleFileArg the argument filepattern is under control of the user who passes it in from the command line. filepattern is passed directly to strcpy copying the path provided by the user into a staticly sized buffer without any length checks resulting in a stack-buffer overflow. An attacker can provide malicious input to trigger this vulnerability.CVE-2021-21815 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT&T Labs Xmill 0.7. Within `DecodeTreeBlock,` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer.CVE-2021-21826 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A heap-based buffer overflow vulnerability exists in the XML Decompression DecodeTreeBlock functionality of AT&T Labs Xmill 0.7. Within `DecodeTreeBlock` which is called during the decompression of an XMI file, a UINT32 is loaded from the file and used as trusted input as the length of a buffer. An attacker can provide a malicious file to trigger this vulnerability.CVE-2021-21827 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). In the command-line-parsing HandleFileArg functionality of AT&T Labs ' Xmill 0.7, an attacker could trigger the vulnerability by using a specially crafted command-line argument that can lead to code execution.CVE-2021-21828 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file could lead to remote code execution.CVE-2022-26507 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-20-287-02 | LCDS LAquis SCADA | An attacker who convinces a valid user to open a specially crafted project file to exploit could execute code under the privileges of the application due to an out-of-bounds read vulnerability.CVE-2020-25188 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-23-339-01 | Zebra ZTC Industrial ZT400 and ZTC Desktop GK420d | A vulnerability of authentication bypass has been found in Zebra Technologies ZTC Industrial ZT410 and ZTC Desktop GK420d. This vulnerability allows an attacker that is in the same network as the printer to change the username and password for the web page by sending a specially crafted POST request to the setvarsResults.cgi file. For this vulnerability to be exploitable, the printer's protected mode must be disabled. | [] | null | null | 5.4 | null |
ICSA-22-298-04 | Hitachi Energy MicroSCADA X DMS600 | A vulnerability exists when Hitachi Energy MicroSCADA X DMS600 v4.5 uses an affected version of PostgreSQL. While modifying certain SQL array values, missing bounds checks let authenticated database users write arbitrary bytes to a wide area of server memory. Successful exploitation of this vulnerability could allow attackers to gain access to the data, causing confidentiality and integrity issues.CVE-2021-32027 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A vulnerability exists when Hitachi Energy MicroSCADA X DMS600 v4.5 uses an affected version of PostgreSQL. When using an INSERT ... ON CONFLICT ... DO UPDATE command on a purpose-crafted table, an authenticated database user could read arbitrary bytes of server memory.CVE-2021-32028 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 6.5 | null |
ICSA-19-311-01 | Mitsubishi Electric MELSEC-Q Series and MELSEC-L Series CPU Modules | A remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.CVE-2019-13555 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-17-222-04 | Fuji Electric Monitouch V-SFT | The stack-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution.CVE-2017-9659 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). A heap-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution.CVE-2017-9660 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). Monitouch V-SFT is installed in a directory with weak access controls by default, which could allow an authenticated attacker with local access to escalate privileges.CVE-2017-9662 has been assigned to this vulnerability. A CVSS v3 base score of 4.5 has been assigned; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L). | [] | null | null | 4.5 | null |
ICSA-24-226-03 | Rockwell Automation GuardLogix/ControlLogix 5580 Controller | A denial-of-service vulnerability exists in the affected products. The vulnerability occurs when a malformed CIP packet is sent over the network to the device and results in a major nonrecoverable fault causing a denial-of-service. | [] | null | 7.5 | null | null |
ICSA-21-236-01 | Hitachi ABB Power Grids TropOS | The 802.11 standard that underpins Wi-Fi protected access (WPA, WPA2, and WPA3) and wired equivalent privacy (WEP) does not require received fragments be cleared from memory after (re)connecting to a network. Under the right circumstances, when another device sends fragmented frames encrypted using WEP, CCMP, or GCMP, this vulnerability can be exploited to inject arbitrary network packets and/or exfiltrate user data.CVE-2020-24586 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). The 802.11 standard that underpins Wi-Fi protected access (WPA, WPA2, and WPA3) and wired equivalent privacy (WEP) does not require all fragments of a frame are encrypted under the same key. An adversary could exploit this vulnerability to decrypt selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP encryption key is periodically renewed.CVE-2020-24587 has been assigned to this vulnerability. A CVSS v3 base score of 2.6 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N). The 802.11 standard that underpins Wi-Fi protected access (WPA, WPA2, and WPA3) and wired equivalent privacy (WEP) does not require the A-MSDU flag in the plaintext QoS header field be authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary could exploit this vulnerability to inject arbitrary network packets.CVE-2020-24588 has been assigned to this vulnerability. A CVSS v3 base score of 3.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N). An access point (AP) forwards EAPOL frames to other clients even though the sender has not yet successfully authenticated to the AP. This might be abused in projected Wi-Fi networks to launch denial-of-service attacks against connected clients and makes it easier to exploit other vulnerabilities in connected clients.CVE-2020-26139 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H). The WEP, WPA, WPA2, and WPA3 implementations accept plaintext frames in a protected Wi-Fi network. An adversary can exploit this vulnerability to inject arbitrary data frames independent of the network configuration.CVE-2020-26140 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). The Wi-Fi implementation does not verify the message integrity check (authenticity) of fragmented TKIP frames. An adversary can exploit this vulnerability to inject and decrypt packets in WPA or WPA2 networks that support the TKIP data-confidentiality protocol.CVE-2020-26141 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). The WEP, WPA, WPA2, and WPA3 implementations treat fragmented frames as full frames. An adversary can exploit this vulnerability to inject arbitrary network packets independent of the network configuration.CVE-2020-26142 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). The WEP, WPA, WPA2, and WPA3 implementations accept fragmented plaintext frames in a protected Wi-Fi network. An adversary can exploit this vulnerability to inject arbitrary data frames independent of the network configuration.CVE-2020-26143 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). The WEP, WPA, WPA2, and WPA3 implementations accept plaintext A-MSDU frames as long as the first eight bytes correspond to a valid RFC1042 (i.e., LLC/SNAP) header for EAPOL. An adversary can exploit this vulnerability to inject arbitrary network packets independent of the network configuration.CVE-2020-26144 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). The WEP, WPA, WPA2, and WPA3 implementations accept second (or subsequent) broadcast fragments when sent in plaintext and process them as full unfragmented frames. An adversary can exploit this vulnerability to inject arbitrary network packets independent of the network configuration.CVE-2020-26145 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). The WPA, WPA2, and WPA3 implementations reassemble fragments with non-consecutive packet numbers. An adversary can exploit this vulnerability to exfiltrate selected fragments. This vulnerability is exploitable when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used. Note: WEP is vulnerable to this attack by design.CVE-2020-26146 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:N). The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. An adversary can exploit this vulnerability to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.CVE-2020-26147 has been assigned to this vulnerability. A CVSS v3 base score of 5.4 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:R/S:U/C:L/I:H/A:N). | [] | null | null | 5.4 | null |
ICSA-21-110-04 | Delta Electronics CNCSoft ScreenEditor | The affected product is vulnerable to an out-of-bounds read while processing project files, which may allow an attacker to execute arbitrary code.CVE-2021-22668 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-21-005-05 | Delta Electronics DOPSoft | The affected product is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code.CVE-2020-27275 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The affected product has a null pointer dereference issue while processing project files, which may allow an attacker to execute arbitrary code.CVE-2020-27277 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-21-350-07 | Siemens POWER METER SICAM Q100 | The affected firmware contains a buffer overflow vulnerability in the web application that could allow a remote attacker with engineer or admin priviliges to potentially perform remote code execution. | [] | null | 9.1 | null | null |
ICSA-24-074-12 | Delta Electronics DIAEnergie | Privileges are not fully verified server-side, which can be abused by a user with limited privileges to bypass authorization and access privileged functionality SQL injection vulnerability exists in the script Handler_CFG.ashx. SQL injection vulnerability exists in the script DIAE_tagHandler.ashx. SQL injection vulnerability exists in GetDIAE_astListParameters. SQL injection vulnerability exists in GetDIAE_slogListParameters. SQL injection vulnerability exists in GetDIAE_unListParameters. SQL injection vulnerability exists in GetDIAE_usListParameters. It is possible to perform a path traversal attack and write outside of the intended directory. If a file name is specified that already exists on the file system, then the original file will be overwritten. Path traversal attack is possible and write outside of the intended directory and may access sensitive information. If a file name is specified that already exists on the file system, then the original file will be overwritten. Improper Neutralization of Input within the affected product could lead to cross-site Scripting. | [] | null | 4.6 | null | null |
ICSA-22-300-01 | Rockwell Automation FactoryTalk Alarm and Events Server | An unauthenticated attacker with network access to a victim's Rockwell Automation FactoryTalk Alarm and Events service could open a connection, causing the service to fault and become unavailable. The affected port could be used as a server ping port and uses messages structured with XML.CVE-2022-38744 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-22-032-02 | Advantech ADAM-3600 | The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.CVE-2022-22987 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-21-040-10 | Siemens DIGSI 4 | Several folders in the %PATH% are writeable by normal users. As these folders are included in the search for dlls, an attacker could place dlls there with code executed by SYSTEM. | [] | null | 7.8 | null | null |
ICSA-20-042-04 | Siemens PROFINET-IO Stack (Update H) | Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit
internal resource allocation when multiple legitimate diagnostic package
requests are sent to the DCE-RPC interface.
This could lead to a denial of service condition due to lack of memory
for devices that include a vulnerable version of the stack.
The security vulnerability could be exploited by an attacker with network
access to an affected device. Successful exploitation requires no system
privileges and no user interaction. An attacker could use the vulnerability
to compromise the availability of the device. CVE-2019-13946 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | 7.5 | null | null |
ICSA-19-120-01 | ICSA-19-120-01_Rockwell Automation CompactLogix 5370 | An attacker could send a crafted HTTP/HTTPS request to render the web server unavailable and/or lead to remote code execution caused by a stack-based buffer overflow vulnerability. A cold restart is required for recovering the system.CVE-2019-10952 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). An attacker could send crafted SMTP packets to cause a denial-of-service condition where the controller enters a major non-recoverable faulted state (MNRF). CVE-2019-10954 has been assigned to this vulnerability. A CVSS v3 base score of 8.6 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H). | [] | null | null | 8.6 | null |
ICSA-21-180-04 | JTEKT TOYOPUC PLC | When the affected products receive an invalid frame, the outside area of a receive buffer for FL-net are overwritten. As a result, the PLC CPU detects a system error, and the affected products stop.CVE-2021-27477 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 6.5 | null |
ICSA-18-123-01 | Lantech IDS 2102 | Nearly all input fields allow for arbitrary input on the device.CVE-2018-8869 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A stack-based buffer overflow vulnerability has been identified which may allow remote code execution.CVE-2018-8865 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-23-131-14 | Rockwell Automation PanelView 800 | The affected product is vulnerable to an out-of-bounds write, which could allow an attacker to accomplish a heap buffer overflow if the user has the email feature enabled in the project file WolfSSL uses. This feature is disabled by default. CVE-2020-36177 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The affected product is vulnerable to an out-of-bounds read, which could allow an attacker to accomplish a heap buffer overflow if the user has the email feature enabled in the project file WolfSSL uses. This feature is disabled by default. CVE-2019-16748 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | 7.8 | null | null |
ICSMA-17-250-02A | Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump Vulnerabilities (Update A) | A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. CVE-2017-12724 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. CVE-2017-12724 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. CVE-2017-12726 been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. CVE-2017-12724 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. CVE-2017-12726 been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). The pump does not validate host certificate, leaving the pump vulnerable to a man-in-the-middle (MITM) attack. CVE-2017-12721 been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). A third-party component used in the pump does not verify input buffer size prior to copying, leading to a buffer overflow, allowing remote code execution on the target device. The pump receives the potentially malicious input infrequently and under certain conditions, increasing the difficulty of exploitation. CVE-2017-12718 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module. CVE-2017-12722 been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). The pump with default network configuration uses hard-coded credentials to automatically establish a wireless network connection. The pump will establish a wireless network connection even if the pump is Ethernet connected and active; however, if the wireless association is established and the Ethernet cable is attached, the pump does not attach the network stack to the wireless network. In this scenario, all network traffic is instead directed over the wired Ethernet connection. CVE-2017-12725 been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump does not require authentication if the pump is configured to allow FTP connections. CVE-2017-12720 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). The FTP server on the pump contains hardcoded credentials, which are not fully initialized. The FTP server is only accessible if the pump is configured to allow FTP connections. CVE-2017-12724 been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). Telnet on the pump uses hardcoded credentials, which can be used if the pump is configured to allow external communications. Smiths Medical assesses that it is not possible to upload files via Telnet and the impact of this vulnerability is limited to the communications module. CVE-2017-12726 been assigned to this vulnerability. A CVSS v3 base score of 5.6 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L). The pump does not validate host certificate, leaving the pump vulnerable to a man-in-the-middle (MITM) attack. CVE-2017-12721 been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). The pump stores some passwords in the configuration file, which are accessible if the pump is configured to allow external communications. CVE-2017-12723 been assigned to this vulnerability. A CVSS v3 base score of 3.7 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N). | [] | null | null | 3.7 | null |
ICSA-19-164-02 | WAGO Industrial Managed Switches 852-303, 852-1305, and 852-1505 | An attacker with access to the hard-coded credentials may gain access to the operating system of the managed switch with root privileges, which may allow manipulation of the operating system of the managed switch.CVE-2019-12550 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An attacker with access to the hard-coded SSH key may disrupt communication or compromise the managed switch. The SSH-keys cannot be regenerated by users and all switches use the same key. CVE-2019-12549 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).. 3.2.3 USING COMPONENTS WITH KNOWN VULNERABILITIES 3.2.3 USING COMPONENTS WITH KNOWN VULNERABILITIES. The listed managed switches use outdated third-party components with known vulnerabilities. See the full list of CVE identifiers in CERT@VDE advisory number VDE-2019-013.CVE-2019-12549 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-23-131-09 | Rockwell Automation Kinetix 5500 | Rockwell Automation Kinetix 5500 devices manufactured between May 2022 and January 2023 running Version 7.13 have telnet and file transfer protocol (FTP) ports open by default. This could allow an attacker access to the device. CVE-2023-1834 has been assigned to this vulnerability. A CVSS v3 base score of 9.4 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H). | [] | null | 9.4 | null | null |
ICSA-21-131-12 | Siemens SIMATIC SmartVNC HMI WinCC Products (Update B) | SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the server side when sending data from the client, which could result in a Denial-of-Service condition. SmartVNC has an out-of-bounds memory access vulnerability that could be triggered on the client side when sending data from the server, which could result in a Denial-of-Service condition. SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition. SmartVNC has a heap allocation leak vulnerability in the server Tight encoder, which could result in a Denial-of-Service condition. SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution. A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition. SmartVNC has a heap allocation leak vulnerability in the device layout handler on client side, which could result in a Denial-of-Service condition. | [] | null | 7.5 | null | null |
ICSA-21-110-05 | Delta Electronics CNCSoft-B | The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.CVE-2021-22660 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). The affected product is vulnerable to an out-of-bounds write, which may allow an attacker to execute arbitrary code.CVE-2021-22664 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). | [] | null | null | 7.8 | null |
ICSA-22-088-01 | Rockwell Automation ISaGRAF | When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality. CVE-2022-1018 has been assigned to this vulnerability. A CVSS v3 base score of 5.5 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N). | [] | null | null | 5.5 | null |
ICSMA-22-251-01 | Baxter Sigma Spectrum Infusion Pump (Update A) | The Baxter Spectrum WBM (v16, v16D38, v17, v17D19, v20D29 to v20D32, and v22D19 to v22D28) stores network credentials and patient health information (PHI) in unencrypted form. PHI is only stored in Spectrum IQ pumps using auto programming. An attacker with physical access to a device without all data and settings erased may be able to extract sensitive information. CVE-2022-26390 has been assigned to this vulnerability. A CVSS v3 base score of 4.2 has been calculated; the CVSS vector string is (AV:P/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N). The Baxter Spectrum WBM (v16, v16D38, v17, v17D19, and v20D29 to v20D32) when in superuser mode is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM, potentially accessing sensitive information. The Baxter Spectrum WBM (v16, v16D38) and Baxter Spectrum WBM (v17, v17D19, v20D29 to v20D32), when in superuser mode, are susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information. CVE-2022-26392 has been assigned to this vulnerability. A CVSS v3 base score of 3.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:N/A:N). The Baxter Spectrum WBM (v20D29) is susceptible to format string attacks via application messaging. An attacker could use this to read memory in the WBM to access sensitive information or cause a denial-of-service condition on the WBM. CVE-2022-26393 has been assigned to this vulnerability. A CVSS v3 base score of 5.0 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:L/UI:N/S:U/C:L/I:L/A:L). The Baxter Spectrum WBM (v16, v16D38, v17, v17D19, and v20D29 to v20D32) does not perform mutual authentication with the gateway server host. This could allow an attacker to perform a machine-in-the-middle attack that modifies parameters, making the network connection fail. Alternatively, an attacker could spoof the server host and send specifically crafted data. CVE-2022-26394 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:C/C:L/I:H/A:L). | [] | null | null | 7.5 | null |
ICSA-24-354-03 | Delta Electronics DTM Soft | The affected product deserializes objects, which could allow an attacker to execute arbitrary code. | [] | null | 7.8 | null | null |
ICSA-22-055-03 | Schneider Electric Easergy P5 and P3 | If an attacker were to obtain the SSH cryptographic key for the device and take active control of the local operational network connected to this product, they could observe and manipulate traffic associated with product configuration. This could result in information disclosure. CVE-2022-22722 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A buffer copy without checking size of input vulnerability exists in Easergy P5 devices that could lead to a buffer overflow, causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping functions via GOOSE can be impacted. CVE-2022-22723 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A buffer copy without checking size of input vulnerability exists in Easergy P3 devices that could lead to a buffer overflow, causing program crashes and arbitrary code execution when specially crafted packets are sent to the device over the network. Protection functions and tripping functions via GOOSE can be impacted. CVE-2022-22725 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An Improper Input Validation vulnerability exists in Easergy P5 devices that cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. CVE-2022-34758 has been assigned to this vulnerability. A CVSS v3 base score of 5.1 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:L). | [] | null | null | 5.1 | null |
ICSA-23-348-07 | Siemens SIMATIC STEP 7 (TIA Portal) | An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application. | [] | null | 4.2 | null | null |
ICSA-17-283-02 | JanTek JTC-200 | An attacker could perform actions with the same permissions as a victim user, provided the victim has an active session and is induced to trigger the malicious request.CVE-2016-5789 has been assigned to this vulnerability. A CVSS v3 base score of 8.0 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H). The improper authentication could provide undocumented Busybox Linux shell accessible over Telnet service without any authentication.CVE-2016-5791 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 9.8 | null |
ICSA-23-348-12 | Siemens SCALANCE and RUGGEDCOM M-800/S615 Family | Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device. An Improper Neutralization of Special Elements used in an OS Command with root privileges vulnerability exists in the parsing of the IPSEC configuration. This could allow malicious local administrators to issue commands on system level after a new connection is established. | [] | null | 7.2 | null | null |
ICSA-24-074-11 | Siemens RUGGEDCOM APE1808 with Fortigate NGFW Devices | An improper certificate validation vulnerability [CWE-295] in FortiOS 7.2.0 through 7.2.3, 7.0.0 through 7.0.7, 6.4 all versions, 6.2 all versions, 6.0 all versions and FortiProxy 7.0.0 through 7.0.6, 2.0 all versions, 1.2 all versions may allow a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the communication channel between the FortiOS/FortiProxy device and remote servers hosting threat feeds (when the latter are configured as Fabric connectors in FortiOS/FortiProxy) A cleartext transmission of sensitive information vulnerability [CWE-319] in Fortinet FortiOS version 7.2.0 through 7.2.4, 7.0.0 through 7.0.8, FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.8 allows an authenticated attacker with readonly superadmin privileges to intercept traffic in order to obtain other adminstrators cookies via diagnose CLI commands. A improper limitation of a pathname to a restricted directory vulnerability ('path traversal') [CWE-22] in Fortinet FortiOS version 7.2.0 through 7.2.3, 7.0.0 through 7.0.9 and before 6.4.11 allows a privileged attacker to read and write files on the underlying Linux system via crafted CLI commands. An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in Fortinet FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.7, FortiOS version 7.2.0 through 7.2.3 and 7.0.0 through 7.0.9 allows an unauthenticated attackers to obtain sensitive logging informations on the device via crafted HTTP GET requests. An improper neutralization of input during web page generation vulnerability ('Cross-site Scripting') [CWE-79] in Fortinet FortiOS version 7.2.0 through 7.2.3, version 7.0.0 through 7.0.9, version 6.4.0 through 6.4.11 and before 6.2.12 and FortiProxy version 7.2.0 through 7.2.1 and before 7.0.7 allows an unauthenticated attacker to perform an XSS attack via crafted HTTP GET requests. An improper neutralization of input during web page generation [CWE-79] vulnerability in FortiOS versions 7.0.0 to 7.0.7 and 7.2.0 to 7.2.3 may allow a remote, unauthenticated attacker to launch a cross site scripting (XSS) attack via the "redir" parameter of the URL seen when the "Sign in with FortiCloud" button is clicked. A permissive list of allowed inputs vulnerability [CWE-183] in FortiGate version 7.2.3 and below, version 7.0.9 and below Policy-based NGFW Mode may allow an authenticated SSL-VPN user to bypass the policy via bookmarks in the web portal. A relative path traversal vulnerability [CWE-23] in Fortinet FortiOS version 7.2.0 through 7.2.3, version 7.0.0 through 7.0.9 and before 6.4.12, FortiProxy version 7.2.0 through 7.2.1 and 7.0.0 through 7.0.7, FortiSwitchManager version 7.2.0 through 7.2.1 and before 7.0.1 allows an privileged attacker to delete arbitrary directories from the filesystem through crafted HTTP requests. A relative path traversal vulnerability [CWE-23] in Fortinet FortiOS version 7.2.0 through 7.2.2, 7.0.0 through 7.0.8 and before 6.4.11, FortiProxy version 7.2.0 through 7.2.2 and 7.0.0 through 7.0.8 allows privileged VDOM administrators to escalate their privileges to super admin of the box via crafted CLI requests. An improper restriction of excessive authentication attempts vulnerability [CWE-307] in Fortinet FortiOS version 7.2.0 through 7.2.3 and before 7.0.10, FortiProxy version 7.2.0 through 7.2.2 and before 7.0.8 administrative interface allows an attacker with a valid user account to perform brute-force attacks on other user accounts via injecting valid login sessions. A use of externally-controlled format string in Fortinet FortiOS version 7.2.0 through 7.2.4, FortiOS all versions 7.0, FortiOS all versions 6.4, FortiOS all versions 6.2, FortiProxy version 7.2.0 through 7.2.1, FortiProxy version 7.0.0 through 7.0.7 allows attacker to execute unauthorized code or commands via specially crafted commands. An access of uninitialized pointer vulnerability [CWE-824] in the SSL VPN portal of Fortinet FortiOS version 7.2.0 through 7.2.3, version 7.0.0 through 7.0.9 and before 6.4.11 and FortiProxy version 7.2.0 through 7.2.1, version 7.0.0 through 7.0.7 and before 2.0.11 allows a remote authenticated attacker to crash the sslvpn daemon via an HTTP GET request. A out-of-bounds write in Fortinet FortiOS version 7.2.0 through 7.2.3, FortiOS version 7.0.0 through 7.0.10, FortiOS version 6.4.0 through 6.4.12, FortiOS all versions 6.2, FortiOS all versions 6.0, FortiProxy version 7.2.0 through 7.2.2, FortiProxy version 7.0.0 through 7.0.8, FortiProxy all versions 2.0, FortiProxy all versions 1.2, FortiProxy all versions 1.1, FortiProxy all versions 1.0 allows attacker to escalation of privilege via specifically crafted commands. A out-of-bounds write in Fortinet FortiOS version 7.2.0 through 7.2.3, FortiOS version 7.0.0 through 7.0.10, FortiOS version 6.4.0 through 6.4.11, FortiOS version 6.2.0 through 6.2.13, FortiOS all versions 6.0, FortiProxy version 7.2.0 through 7.2.1, FortiProxy version 7.0.0 through 7.0.7, FortiProxy all versions 2.0, FortiProxy all versions 1.2, FortiProxy all versions 1.1, FortiProxy all versions 1.0 allows an authenticated attacker to execute unauthorized code or commands via specifically crafted requests. A url redirection to untrusted site ('open redirect') in Fortinet FortiOS version 7.2.0 through 7.2.3, FortiOS version 7.0.0 through 7.0.9, FortiOS versions 6.4.0 through 6.4.12, FortiOS all versions 6.2, FortiOS all versions 6.0, FortiProxy version 7.2.0 through 7.2.2, FortiProxy version 7.0.0 through 7.0.8, FortiProxy all versions 2.0, FortiProxy all versions 1.2, FortiProxy all versions 1.1, FortiProxy all versions 1.0 allows an authenticated attacker to execute unauthorized code or commands via specially crafted requests. A buffer underwrite ('buffer underflow') vulnerability in FortiOS, FortiManager, FortiAnalyzer, FortiWeb, FortiProxy & FortiSwitchManager administrative interface may allow a remote unauthenticated attacker to execute arbitrary code on the device and/or perform a DoS on the GUI, via specifically crafted requests. An insertion of sensitive information into log file vulnerability in Fortinet FortiOS 7.2.0 through 7.2.4 and FortiProxy 7.0.0 through 7.0.10. 7.2.0 through 7.2.1 allows an attacker to read certain passwords in plain text. A heap-based buffer overflow vulnerability [CWE-122] in FortiOS version 7.2.4 and below, version 7.0.11 and below, version 6.4.12 and below, version 6.0.16 and below and FortiProxy version 7.2.3 and below, version 7.0.9 and below, version 2.0.12 and below, version 1.2 all versions, version 1.1 all versions SSL-VPN may allow a remote attacker to execute arbitrary code or commands via specifically crafted requests. An insufficient session expiration in Fortinet FortiOS 7.0.0 - 7.0.12 and 7.2.0 - 7.2.4 allows an attacker to execute unauthorized code or commands via reusing the session of a deleted user in the REST API. An improper validation of integrity check value vulnerability [CWE-354] in FortiOS VMs may allow a local attacker with admin privileges to boot a malicious image on the device and bypass the filesystem integrity check in place. An improper certificate validation vulnerability [CWE-295] in FortiOS 6.2 all versions, 6.4 all versions, 7.0.0 through 7.0.10, 7.2.0 and FortiProxy 1.2 all versions, 2.0 all versions, 7.0.0 through 7.0.9, 7.2.0 through 7.2.3 may allow a remote and unauthenticated attacker to perform a Man-in-the-Middle attack on the communication channel between the vulnerable device and the remote FortiGuard's map server. A access of uninitialized pointer vulnerability [CWE-824] in Fortinet FortiProxy version 7.2.0 through 7.2.3 and before 7.0.9 and FortiOS version 7.2.0 through 7.2.4 and before 7.0.11 allows an authenticated attacker to repetitively crash the httpsd process via crafted HTTP or HTTPS requests. A NULL pointer dereference vulnerability [CWE-476] in FortiOS may allow an authenticated attacker to crash the SSL-VPN daemon via specially crafted HTTP requests to the /proxy endpoint A NULL pointer dereference vulnerability [CWE-476] in FortiOS may allow a remote unauthenticated attacker to crash the SSL-VPN daemon via specially crafted HTTP requests. A use of externally-controlled format string vulnerability [CWE-134] in the Fclicense daemon of FortiOS may allow a remote authenticated attacker to execute arbitrary code or commands via specially crafted requests. An improper neutralization of input during web page generation ('Cross-site Scripting') vulnerability [CWE-79] in FortiProxy 7.2.0 through 7.2.4, 7.0.0 through 7.0.10 and FortiOS 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.12, 6.2.0 through 6.2.14 GUI may allow an authenticated attacker to trigger malicious JavaScript code execution via crafted guest management setting. An improper access control vulnerability in Fortinet FortiOS 7.2.0 - 7.2.4 and 7.4.0 allows an attacker to access a restricted resource from a non trusted host. A loop with unreachable exit condition ('infinite loop') in Fortinet FortiOS version 7.2.0 through 7.2.4, FortiOS version 7.0.0 through 7.0.10, FortiOS 6.4 all versions, FortiOS 6.2 all versions, FortiOS 6.0 all versions, FortiProxy version 7.2.0 through 7.2.3, FortiProxy version 7.0.0 through 7.0.9, FortiProxy 2.0 all versions, FortiProxy 1.2 all versions, FortiProxy 1.1 all versions, FortiProxy 1.0 all versions, FortiWeb version 7.2.0 through 7.2.1, FortiWeb version 7.0.0 through 7.0.6, FortiWeb 6.4 all versions, FortiWeb 6.3 all versions allows attacker to perform a denial of service via specially crafted HTTP requests. A NULL pointer dereference vulnerability [CWE-476] in SSL-VPN may allow an authenticated remote attacker to trigger a crash of the SSL-VPN service via crafted requests. A NULL pointer dereference vulnerability [CWE-476] in SSL-VPN may allow an authenticated remote attacker to trigger a crash of the SSL-VPN service via crafted requests. A stack-based overflow vulnerability [CWE-124] in Fortinet FortiOS version 7.0.0 through 7.0.10 and 7.2.0 through 7.2.3 and FortiProxy version 7.0.0 through 7.0.9 and 7.2.0 through 7.2.2 allows a remote unauthenticated attacker to execute arbitrary code or command via crafted packets reaching proxy policies or firewall policies with proxy mode alongside deep or full packet inspection. An improper neutralization of script-related html tags in a web page (basic xss) in Fortinet FortiOS 7.2.0 - 7.2.4 allows an attacker to execute unauthorized code or commands via the SAML and Security Fabric components. A use of externally-controlled format string in Fortinet FortiProxy versions 7.2.0 through 7.2.4, 7.0.0 through 7.0.10, FortiOS versions 7.4.0, 7.2.0 through 7.2.4, 7.0.0 through 7.0.11, 6.4.0 through 6.4.12, 6.2.0 through 6.2.15, 6.0.0 through 6.0.17, FortiPAM versions 1.0.0 through 1.0.3 allows attacker to execute unauthorized code or commands via specially crafted API requests. A null pointer dereference [CWE-476] in FortiOS and FortiProxy SSL VPN may allow an authenticated attacker to perform a DoS attack on the device via specifically crafted HTTP requests. A use of GET request method with sensitive query strings vulnerability in Fortinet FortiOS 7.0.0 - 7.0.12, 7.2.0 - 7.2.5 and 7.4.0 allows an attacker to view plaintext passwords of remote services such as RDP or VNC, if the attacker is able to read the GET requests to those services. A interpretation conflict in Fortinet IPS Engine versions 7.321, 7.166 and 6.158 allows attacker to evade IPS features via crafted TCP packets. A use after free vulnerability [CWE-416] in FortiOS version 7.2.0 through 7.2.4 and version 7.0.0 through 7.0.10 and FortiProxy version 7.2.0 through 7.2.2 and version 7.0.0 through 7.0.8 may allow an unauthenticated remote attacker to crash the WAD process via multiple crafted packets reaching proxy policies or firewall policies with proxy mode alongside SSL deep packet inspection. An improper authorization vulnerability in Fortinet FortiOS 7.0.0 - 7.0.11 and 7.2.0 - 7.2.4 allows an attacker belonging to the prof-admin profile to perform elevated actions. | [] | null | 8.1 | null | null |
ICSA-20-044-02 | Schneider Electric Magelis HMI Panels | When the device receives a high rate of frames, the HMI may temporarily freeze. When the attack stops, the buffered commands are processed by the HMI.CVE-2019-6833 has been assigned to this vulnerability. A CVSS v3 base score of 7.4 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:N/A:H). | [] | null | null | 7.4 | null |
ICSA-21-159-11 | Siemens SIMATIC NET CP 443-1 OPC UA | The rate limiting feature in NTP 4.x before 4.2.8p4 and 4.3.x before 4.3.77 allows remote attackers to have unspecified impact via a large number of crafted requests. The datalen parameter in the refclock driver in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to execute arbitrary code or cause a denial of service (crash) via a negative input value. NTP before 4.2.8p6 and 4.3.x before 4.3.90 allows remote attackers to bypass the origin timestamp validation via a packet with an origin timestamp set to zero. An off-path attacker can cause a preemptible client association to be demobilized in NTP 4.2.8p4 and earlier and NTPSec a5fb34b9cc89b92a8fef2f459004865c93bb7f92 by sending a crypto NAK packet to a victim client with a spoofed source address of an existing associated peer. This is true even if authentication is enabled. An attacker can spoof a packet from a legitimate ntpd server with an origin timestamp that matches the peer->dst timestamp recorded for that server. After making this switch, the client in NTP 4.2.8p4 and earlier and NTPSec aa48d001683e5b791a743ec9c575aaf7d867a2b0c will reject all future legitimate server responses. It is possible to force the victim client to move time after the mode has been changed. ntpq gives no indication that the mode has been switched. An exploitable vulnerability exists in the message authentication functionality of libntp in ntp 4.2.8p4 and NTPSec a5fb34b9cc89b92a8fef2f459004865c93bb7f92. An attacker can send a series of crafted messages to attempt to recover the message digest key. The MATCH_ASSOC function in NTP before version 4.2.8p9 and 4.3.x before 4.3.92 allows remote attackers to cause an out-of-bounds reference via an addpeer request with a large hmode value. ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (ephemeral-association demobilization) by sending a spoofed crypto-NAK packet with incorrect authentication data at a certain time. The process_packet function in ntp_proto.c in ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (peer-variable modification) by sending spoofed packets from many source IP addresses in a certain scenario, as demonstrated by triggering an incorrect leap indication. ntpd in NTP 4.x before 4.2.8p8, when autokey is enabled, allows remote attackers to cause a denial of service (peer-variable clearing and association outage) by sending (1) a spoofed crypto-NAK packet or (2) a packet with an incorrect MAC value at a certain time. ntpd in NTP 4.x before 4.2.8p8 allows remote attackers to cause a denial of service (interleaved-mode transition and time change) via a spoofed broadcast packet. NOTE: this vulnerability exists because of an incomplete fix for CVE-2016-1548. NTP before 4.2.8p9 allows remote attackers to bypass the origin timestamp protection mechanism via an origin timestamp of zero. NOTE: this vulnerability exists because of a CVE-2015-8138 regression. NTP before 4.2.8p9 does not properly perform the initial sync calculations, which allows remote attackers to unspecified impact via unknown vectors, related to a "root distance that did not include the peer dispersion." An exploitable denial of service vulnerability exists in the origin timestamp check functionality of ntpd 4.2.8p9. A specially crafted unauthenticated network packet can be used to reset the expected origin timestamp for target peers. Legitimate replies from targeted peers will fail the origin timestamp check (TEST2) causing the reply to be dropped and creating a denial of service condition. Multiple buffer overflows in the ctl_put* functions in NTP before 4.2.8p10 and 4.3.x before 4.3.94 allow remote authenticated users to have unspecified impact via a long variable. | [] | null | 8.8 | null | null |
ICSA-21-103-13 | Siemens SIMOTICS CONNECT 400 (Update A) | The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure. The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition. The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving. | [] | null | 5.3 | null | null |
ICSA-23-306-02 | Mitsubishi Electric MELSEC iQ-F/iQ-R Series CPU Module (Update A) | A denial-of-service vulnerability exists in the web server function of the MELSEC iQ-F/iQ-R Series CPU module, which could allow an attacker to prevent legitimate users from logging in to the web server function for a certain period of time. The impact of this vulnerability will persist while the attacker continues to attempt the attack. | [] | null | 5.3 | null | null |
ICSA-24-228-01 | Siemens SCALANCE M-800, RUGGEDCOM RM1224 | Affected devices do not properly validate the length of inputs when performing certain configuration changes in the web interface allowing an authenticated attacker to cause a denial of service condition. The device needs to be restarted for the web interface to become available again. Affected devices do not properly validate input in specific VPN configuration fields. This could allow an authenticated remote attacker to execute arbitrary code on the device. Affected devices do not properly enforce isolation between user sessions in their web server component. This could allow an authenticated remote attacker to escalate their privileges on the devices. Affected devices insert sensitive information about the generation of 2FA tokens into log files. This could allow an authenticated remote attacker to forge 2FA tokens of other users. | [] | null | 6.5 | null | null |
ICSA-17-054-03 | Schneider Electric Modicon M340 PLC (Update A) | A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution.CVE-2017-6017 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-19-213-03 | 3S-Smart Software Solutions GmbH CODESYS V3 | The CODESYS Gateway does not correctly verify the ownership of a communication channel. CVE-2019-9010 has been assigned to this vulnerability. A CVSS v3 base score of 9.0 has been assigned; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H). A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. CVE-2019-9012 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). | [] | null | null | 7.5 | null |
ICSA-23-108-01 | Omron CS/CJ Series | Omron CS/CJ series programmable logic controllers are missing authentication for the file system. This could allow an attacker to access the file system (via memory card or EM file memory) and obtain all available sensitive information. CVE-2022-45794 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). | [] | null | null | 7.5 | null |
ICSA-23-192-03 | Panasonic Control FPWin Pro7 | In Panasonic Control FPWIN versions 7.6.0.3 and prior, a stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or a parameter to a function). Panasonic Control FPWIN versions 7.6.0.3 and prior allocates or initializes a resource such as a pointer, object, or variable using one type, but later accesses that resource using a type that is incompatible with the original type. Panasonic Control FPWIN performs operations on a memory buffer, but can read from or write to a memory location that is outside of the intended boundary of the buffer. | [] | null | null | 7.8 | null |
ICSA-23-166-08 | Siemens SIMATIC STEP 7 and Derived Products | The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.
An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server. | [] | null | 9.9 | null | null |
ICSA-19-337-02 | Moxa AWK-3121 | The device uses HTTP traffic by default allowing insecure communication to the web server, which could allow an attacker to compromise sensitive data such as credentials.CVE-2018-10690 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). An attacker can navigate to a URL and download the system log without authentication, which may allow access to sensitive information.CVE-2018-10691 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). A cross-site scripting attack allows access to session cookies, which may allow an attacker to login into the device.CVE-2018-10692 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). An unauthorized user may execute network troubleshooting commands to cause a buffer overflow condition, which may allow the attacker to execute commands on the device.CVE-2018-10693 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The Wi-Fi connection used to set up the device is not encrypted by default, which may allow an attacker to capture sensitive data.CVE-2018-10694 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N). An unauthorized user may cause a buffer overflow using the device alert functionality, which may allow the attacker to execute commands on the device.CVE-2018-10695 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The web interface is not protected against CSRF attacks, which may allow an attacker to trick a user into executing commands or actions by clicking a malicious link.CVE-2018-10696 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). An unauthorized user may inject malicious commands into the system while using network troubleshooting functions, which may allow the attacker to execute unauthorized commands on the device.CVE-2018-10697 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). The system enables an insecure service by default, which may allow an attacker to view sensitive information or modify information being transmitted through a man-in-the-middle attack.CVE-2018-10698 has been assigned to this vulnerability. A CVSS v3 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). An unauthorized user can inject malicious commands while using system certificate functions, which may allow the attacker to execute unauthorized commands on the device.CVE-2018-10699 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). An unauthorized user can execute an XSS attack, which may allow the injection of a malicious payload on the server.CVE-2018-10700 has been assigned to this vulnerability. A CVSS v3 base score of 6.1 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N). An unauthorized user may cause a buffer overflow on the system using system troubleshooting functions, which may allow the attacker to execute commands.CVE-2018-10701 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). An unauthorized user may inject malicious commands on the system using system troubleshooting functions, which may allow the attacker to execute commands on the device.CVE-2018-10702 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). An unauthorized user may cause a buffer overflow on the system using system troubleshooting functions, which may allow the attacker to execute commands on the device.CVE-2018-10703 has been assigned to this vulnerability. A CVSS v3 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). | [] | null | null | 8.8 | null |