Search is not available for this dataset
PICKUP VOLTAGE
float64 0
100
| RELEASE VOLTAGE
float64 0
75
| PICKUP TIME
float64 0
100
| RELEASE TIME
float64 0
100
| COIL RESISTANCE
float64 85
115
| LIFE TIME
int64 0
96k
|
---|---|---|---|---|---|
30 | 26 | 10 | 5 | 90 | 0 |
30 | 42 | 0 | 50 | 88 | 0 |
10 | 65 | 60 | 15 | 91 | 0 |
90 | 10 | 70 | 80 | 90 | 9,831 |
80 | 51 | 10 | 10 | 112 | 53,927 |
66 | 5 | 90 | 65 | 103 | 71,030 |
56 | 50 | 65 | 85 | 95 | 67,015 |
66 | 10 | 5 | 70 | 100 | 79,136 |
80 | 51 | 0 | 5 | 115 | 54,569 |
90 | 50 | 5 | 75 | 95 | 13,761 |
100 | 75 | 45 | 65 | 112 | 2,388 |
70 | 60 | 70 | 55 | 114 | 72,321 |
90 | 26 | 0 | 100 | 107 | 12,590 |
10 | 0 | 40 | 15 | 97 | 0 |
90 | 26 | 40 | 85 | 91 | 11,933 |
20 | 42 | 20 | 50 | 91 | 0 |
0 | 1 | 100 | 55 | 85 | 0 |
85 | 51 | 100 | 10 | 85 | 29,131 |
60 | 0 | 50 | 20 | 93 | 64,588 |
90 | 42 | 30 | 60 | 107 | 12,879 |
56 | 34 | 45 | 40 | 100 | 69,773 |
20 | 10 | 0 | 65 | 91 | 0 |
70 | 50 | 65 | 85 | 97 | 84,673 |
80 | 75 | 25 | 15 | 92 | 53,088 |
20 | 1 | 95 | 15 | 103 | 0 |
40 | 5 | 35 | 30 | 106 | 31,932 |
66 | 65 | 70 | 50 | 86 | 68,523 |
0 | 10 | 50 | 75 | 107 | 0 |
40 | 60 | 95 | 65 | 97 | 28,424 |
0 | 10 | 100 | 65 | 95 | 0 |
75 | 42 | 95 | 35 | 108 | 84,044 |
66 | 42 | 35 | 10 | 113 | 83,846 |
100 | 5 | 80 | 70 | 87 | 3,534 |
90 | 26 | 10 | 70 | 103 | 12,809 |
56 | 26 | 45 | 85 | 91 | 64,708 |
40 | 65 | 55 | 15 | 90 | 30,114 |
20 | 34 | 90 | 45 | 106 | 0 |
66 | 65 | 5 | 75 | 93 | 73,522 |
40 | 34 | 55 | 90 | 110 | 35,332 |
90 | 5 | 90 | 5 | 100 | 10,655 |
70 | 5 | 65 | 20 | 108 | 76,434 |
75 | 51 | 20 | 35 | 94 | 80,481 |
40 | 60 | 65 | 25 | 92 | 30,712 |
20 | 34 | 100 | 85 | 101 | 0 |
85 | 42 | 30 | 10 | 103 | 36,326 |
50 | 75 | 75 | 20 | 85 | 41,439 |
66 | 10 | 35 | 100 | 114 | 71,896 |
75 | 51 | 30 | 50 | 104 | 78,333 |
0 | 10 | 40 | 60 | 104 | 0 |
10 | 34 | 55 | 15 | 110 | 0 |
60 | 34 | 20 | 95 | 90 | 75,188 |
70 | 10 | 90 | 10 | 111 | 77,867 |
0 | 18 | 30 | 55 | 109 | 0 |
75 | 42 | 25 | 75 | 98 | 87,784 |
60 | 0 | 20 | 60 | 114 | 61,715 |
90 | 1 | 50 | 60 | 100 | 8,897 |
0 | 5 | 100 | 60 | 98 | 0 |
10 | 34 | 35 | 5 | 96 | 0 |
90 | 75 | 95 | 30 | 115 | 7,766 |
60 | 0 | 35 | 20 | 97 | 66,316 |
100 | 50 | 60 | 20 | 91 | 7,899 |
80 | 0 | 10 | 50 | 97 | 53,295 |
50 | 10 | 30 | 85 | 114 | 46,494 |
10 | 0 | 25 | 50 | 91 | 0 |
0 | 75 | 70 | 10 | 95 | 0 |
85 | 34 | 90 | 80 | 93 | 31,296 |
40 | 65 | 35 | 85 | 114 | 25,699 |
66 | 60 | 75 | 15 | 109 | 72,384 |
56 | 51 | 65 | 35 | 113 | 57,313 |
0 | 18 | 15 | 15 | 92 | 0 |
40 | 75 | 40 | 65 | 111 | 24,096 |
20 | 5 | 90 | 25 | 104 | 0 |
60 | 5 | 5 | 20 | 95 | 73,189 |
66 | 34 | 5 | 35 | 98 | 86,877 |
100 | 0 | 50 | 15 | 89 | 3,295 |
20 | 51 | 55 | 95 | 103 | 0 |
0 | 75 | 20 | 55 | 89 | 0 |
90 | 65 | 15 | 0 | 109 | 10,606 |
70 | 50 | 60 | 5 | 94 | 89,141 |
40 | 1 | 0 | 75 | 109 | 28,511 |
80 | 60 | 35 | 0 | 112 | 53,024 |
90 | 65 | 60 | 40 | 90 | 9,094 |
50 | 65 | 20 | 40 | 91 | 47,168 |
60 | 60 | 15 | 45 | 91 | 68,963 |
0 | 65 | 95 | 60 | 96 | 0 |
85 | 60 | 95 | 80 | 97 | 29,064 |
70 | 0 | 25 | 10 | 95 | 76,701 |
66 | 0 | 80 | 40 | 91 | 67,322 |
10 | 60 | 95 | 35 | 89 | 0 |
56 | 75 | 40 | 100 | 98 | 54,491 |
70 | 42 | 10 | 95 | 86 | 84,938 |
40 | 26 | 20 | 75 | 102 | 39,152 |
50 | 50 | 60 | 80 | 112 | 52,696 |
75 | 26 | 5 | 85 | 108 | 84,917 |
100 | 34 | 25 | 10 | 113 | 7,940 |
10 | 42 | 45 | 25 | 106 | 0 |
40 | 34 | 90 | 50 | 89 | 36,400 |
10 | 0 | 45 | 35 | 108 | 0 |
56 | 60 | 5 | 5 | 95 | 65,882 |
80 | 5 | 50 | 45 | 89 | 51,328 |
End of preview. Expand
in Dataset Viewer.
Miniature Control Relay Dataset
Overview
This dataset provides detailed performance and lifespan data for the Miniature Control Relay (C9-A41X/DC24VR). It includes key electrical and timing characteristics necessary for analyzing relay efficiency, reliability, and suitability for various industrial and control applications.
Fields & Descriptions
- PICKUP VOLTAGE (V) – The minimum voltage required to activate the relay and switch its contacts.
- RELEASE VOLTAGE (V) – The voltage at which the relay deactivates and returns to its default state.
- PICKUP TIME (ms) – The time delay between applying the activation voltage and the relay switching on.
- RELEASE TIME (ms) – The time delay for the relay to return to its original state after voltage removal.
- COIL RESISTANCE (Ω) – The electrical resistance of the relay coil, affecting power consumption and efficiency.
- LIFE TIME (cycles) – The estimated number of operational cycles the relay can complete before failure.
Applications
This dataset is valuable for:
- Industrial Automation – Evaluating relay reliability in control systems.
- Predictive Maintenance – Estimating relay lifespan based on usage conditions.
- Electrical Engineering Research – Analyzing switching characteristics and performance.
- Component Comparison – Comparing the Miniature Control Relay with other relays in the market.
Dataset Access
The dataset is hosted on Hugging Face for easy access and analysis.
License
Specify the license for usage (e.g., MIT, CC BY 4.0, or proprietary).
Citation
If using this dataset in research or projects, please cite:
Pradeep (2024). Miniature Control Relay Dataset.
- Downloads last month
- 20