instruction
stringlengths
150
244
output
stringclasses
28 values
Consider the scope on 'Major Non Intrusive Insp TA921C' in the functional location GIR/FPSOT/CRS/SAFE /TA921C, the given unit name UA921C-DAY TANK DIESEL OIL (T), the corresponding item class discipline would be
Non Structural Tank
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/WAT/WINJ /TO-PSV-54265B the given unit name of Overhaul - CLV - FPSOT/TO-PSV-54265B the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'VIE' in the functional location GIR/FPSOT/COF/INERT/DA895-B, the given unit name NITROGEN STORAGE DRUM (V), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on TA048/COR CP Measurement in the functional location GIR/FPSOH/HSG/STRUC/TA048 the given unit name of WATER BALLAST 4 STARBOARD (T) the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on Insp-GIR-FPSOH/RISER PROTECTOR SB in the functional location GIR/FPSOH/HSG/STRUC/RISER PROTECTOR SB the given unit name of RISER PROTECTOR STARBOARD the corresponding item class discipline would be
FU Items
Consider the scope on Scrap/Replace in the functional location CLV/FPSOT/GAS/COMP /TO-TSV-31459A the given unit name of STANDBY LUBE OIL COOLER THERMAL SAF. VLV the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'UTC + VIE' in the functional location DAL/FPSOT/COF/INWAT/IPN-_NW-0641-02-B513, the given unit name LINE GROUP,H2O TREAT,WATER,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on BV Class Intermediate Survey in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8610B the given unit name of STARBOARD CENTRAL BALLAST 2S the corresponding item class discipline would be
FU Items
Consider the scope on COR - WBT6P - CP Measurement in the functional location DAL/FPSOH/HSG/STRUC/5-TA-8160 the given unit name of NO.6 WATER BALLAST TANK (P) the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on 'VII' in the functional location PAZ/FPSOT/WAT/WFLT /TO-TR-5121, the given unit name HYPOCHLORITE STORAGE TANK, the corresponding item class discipline would be
Non Structural Tank
Consider the scope on 'VIE' in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-51-D670, the given unit name LINE GROUP,HP GAS,GAS,SS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on VIE in the functional location GIR/FPSOT/CRS/AIR /IPN-IA-_407-02-B571 the given unit name of PIPING GROUP AIR GENERATION the corresponding item class discipline would be
Piping
Consider the scope on FI Visual Inspection of complete struct. in the functional location CLV/FPSOT/HSG/STRUC/M120 the given unit name of M120 Structural Module PALLET LAYDOWN the corresponding item class discipline would be
Structure
Consider the scope on Scrap/Replace 6-PSV1-41555A2 in the functional location DAL/FPSOT/COF/INWAT/6-PSV1-41555A2 the given unit name of PRES. SAFETY VALVE, ON DEOIL. HYDROCYCL. the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'VIE' in the functional location GIR/FPSOT/COF/CHEM /IPN-XF-_475-29-B580, the given unit name PIPING GROUP CHEMICAL INJECTION, the corresponding item class discipline would be
Piping
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/CRS/HVAC /HU-PSV-092677 the given unit name of CIRCUIT 1 ECONOMIZER HP PRE-SAFETY VALVE the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Pre-Pop test, overhaul & recalibration in the functional location CLV/FPSOH/OIL/STAB /HU-PVSV-21301A the given unit name of HU-TR-2140A PRESSURE VACUUM SAFETY VALVE the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'CVI' in the functional location DAL/FPSOA/CRS/TELE, the given unit name COMMUNICATION/TELECOM, the corresponding item class discipline would be
Structure
Consider the scope on PAZ-FLOR_X-RAY YEARLY CAMPAIGN in the functional location PAZ/FPSOT the given unit name of PAZFLOR Topsides the corresponding item class discipline would be
Campaign
Consider the scope on 'VIE' in the functional location GIR/FPSOT/OIL/SEP /IPN-GH-_420-20-C513, the given unit name PIPING GROUP OIL SEPARATION, the corresponding item class discipline would be
Piping
Consider the scope on TANKER CHAFFING CHAIN PS/WEAR MEASUR in the functional location GIR/BUOY /OIL/LOAD /PS MOORING TANKER the given unit name of PS MOORING TANKER SIDE the corresponding item class discipline would be
FU Items
Consider the scope on VIE in the functional location DAL/FPSOT/GAS/DEHYD/IPN-_NC-0655-01-F710 the given unit name of LINE GROUP,GAS DEHYD,RAW COND,DUPLEX,IPN the corresponding item class discipline would be
Piping
Consider the scope on CLV/TO-V-35696 FLAME ARRESTOR in the functional location CLV/FPSOH/OIL/STORE/TO-V-35696 the given unit name of FLAME ARRESTOR, VENT COT_1P, HU-TR-2411 the corresponding item class discipline would be
Flame Arrestor
Consider the scope on MOD.GAS INJ. UB516 Insp of tertiary stru in the functional location GIR/FPSOT/HSG/STRUC/MOD GAS INJEC UB516 the given unit name of STRUCTURAL MODULE GAS INJECT fr 71 the corresponding item class discipline would be
Structure
Consider the scope on VIE in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0656-06-G600 the given unit name of LINE GROUP,GAS LIFT,GAS,SS,IPN the corresponding item class discipline would be
Piping
Consider the scope on UTC + VIE in the functional location CLV/FPSOT/COF/COOLW/IPN-_CW-TO76-33-D01 the given unit name of Cooling water piping group the corresponding item class discipline would be
Piping
Consider the scope on 'COR - WB2P - CP Measurement' in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8611B, the given unit name PORT WING BALLAST 2P, the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on 'VIE' in the functional location DAL/FPSOT/EXT/EWELL/IPN-_NH-0630-53-F513, the given unit name LINE GROUP,OIL RAW,OIL,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on PSV-Scrap/Replace in the functional location PAZ/FPSOT/ELE/PWG /TO-TSV-602585A the given unit name of LUB OIL STANDBY COOLER TSV the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on SCD + VIE in the functional location GIR/FPSOT/WAT/WINJ /IPN-DS-_454-06-C670 the given unit name of PIPING GROUP WATER INJECTION the corresponding item class discipline would be
Piping
Consider the scope on VIE in the functional location DAL/FPSOT/EXT/EWELL/IPN-_NH-0630-94-G600 the given unit name of LINE GROUP,OIL RAW,OIL,SS,IPN the corresponding item class discipline would be
Piping
Consider the scope on VIE in the functional location PAZ/FPSOT/ELE/PWG /TO-TZ-6031E the given unit name of MAIN TGE RUN DOWN TANK the corresponding item class discipline would be
Non Structural Tank
Consider the scope on VIE in the functional location PAZ/FPSOT/COF/CHEM /TO-TZ-7566 the given unit name of LDHI BUFFER TANK the corresponding item class discipline would be
Non Structural Tank
Consider the scope on VIE in the functional location GIR/FPSOT/ELE/PWG /DA983-31 the given unit name of YA982-3-STARTING DRYER AIR DRUM the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on 'VIE' in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0654-06-G800, the given unit name LINE GROUP,GAS COMP,GAS,INCONEL,IPN, the corresponding item class discipline would be
Piping
Consider the scope on 'NDE' in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P51-PRM-STR, the given unit name Fourth Topside P51 Structure Inspection, the corresponding item class discipline would be
Structure
Consider the scope on Visual Inspec & Function Test in the functional location PAZ/FPSOT/COF/LIFT /HU-JA-7801B the given unit name of S1 PROCESS DECK PEDESTAL CRANE the corresponding item class discipline would be
Lifting
Consider the scope on 'VIE' in the functional location PAZ/FPSOT/WAT/WFLT /TO-VF-5120D, the given unit name CIP/EFM FILTER FILTER UNIT, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on VIE in the functional location DAL/FPSOT/COF/INWAT/6-DA-4111A1 the given unit name of SAND ACCUMULATOR DRUM the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on 'NDE' in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P41-PRM-STR, the given unit name MODULE P41,TOPSIDE PRIMARY STRUCTURE, the corresponding item class discipline would be
Structure
Consider the scope on Major Non Intrusive Insp TA845 in the functional location GIR/FPSOT/COF/CHEM /TA845 the given unit name of ANTI-SCALE PROCESS TANK (T) the corresponding item class discipline would be
Non Structural Tank
Consider the scope on Major Non Intrusive Insp TA842A in the functional location GIR/FPSOT/COF/CHEM /TA842A the given unit name of BIOCIDE PROCESS TANK (T) the corresponding item class discipline would be
Non Structural Tank
Consider the scope on 'UTC + VIE' in the functional location PAZ/FPSOH/OIL/STORE/IPN-_HL-HU24-32-B03, the given unit name Hydrocarbon liquid piping group, the corresponding item class discipline would be
Piping
Consider the scope on PSD Replacement in the functional location CLV/FPSOT/CRS/HVAC /HU-PSV-092698 the given unit name of CIRCUIT 1 ECONOMIZER HP PRE-SAFETY VALVE the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'BV Class Intermediate Survey' in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8611G, the given unit name PORT WING BALLAST 7P, the corresponding item class discipline would be
FU Items
Consider the scope on 'CLASS PSV GIR/41-PSV-0120-Révision B.V' in the functional location GIR/FPSOT/OIL/STORE/41-PSV0120, the given unit name TA012 SOUPAPE DE SECURITE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'Major Non Intrusive Insp TA971' in the functional location GIR/FPSOT/COF/INERT/TA971, the given unit name DIESEL OIL TANK FOR GENERATION N2 (V), the corresponding item class discipline would be
Non Structural Tank
Consider the scope on GIR/41-PSV-8533C-Replace/Scrap in the functional location GIR/FPSOT/COF/CHEM /41-PSV8533C the given unit name of SOUPAPE SUR., SORTIE POMPE INJ. BLEND the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on PIPERAC6_Visual inspect of complet struc in the functional location GIR/FPSOT/HSG/STRUC/MOD PIPERACK 6 the given unit name of STRUCTURAL MODULE PIPERACK 6 fr 71-78 the corresponding item class discipline would be
Structure
Consider the scope on VII in the functional location GIR/FPSOT/OIL/SEP /DS301 the given unit name of FIRST STAGE PRODUCTION SEPARATOR (V) the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on VIE in the functional location DAL/FPSOT/OIL/SEP /IPN-_GH-0631-15-C513 the given unit name of LINE GROUP,OIL 1ST,OILY EFLUENT,CS,IPN the corresponding item class discipline would be
Piping
Consider the scope on VII in the functional location PAZ/FPSOT/OIL/SEP /TO-VF-2001 the given unit name of PRODUCED WATER SAND JETTING FILTER UNIT the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on VII in the functional location PAZ/FPSOT/GAS/DEHYD/TO-ES-3001B the given unit name of DEHYDRATION INLET COOLER B HEATER B the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on 'VIE' in the functional location PAZ/FPSOT/COF/INERT/TO-VZ-7411B, the given unit name INERT GAS GENERATOR SKID DRUM, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on VIE in the functional location CLV/FPSOH/CRS/SAFE /HU-TZ-0203 the given unit name of WORKBOAT HYDRAULIC UNIT OIL TANK the corresponding item class discipline would be
Non Structural Tank
Consider the scope on 'GIR/41-PSV-8431A--Replace/Scrap' in the functional location GIR/FPSOT/COF/CHEM /41-PSV8431A, the given unit name GX842A SOUPAPE DE SECURITE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'RB_PS-visual inspection of tertiary stru' in the functional location PAZ/FPSOH/HSG/STRUC/RISER BALCONY PS, the given unit name RISER BALCONY PORTSIDE, the corresponding item class discipline would be
Structure
Consider the scope on 'VIE' in the functional location PAZ/FPSOH/CRS/HVAC /HU-EL-0911A, the given unit name MAIN CHW UNIT A CONDENSER COOLING A, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on VIE in the functional location CLV/FPSOT/GAS/DEHYD/TO-EZ-3021A the given unit name of HOT RICH/LEAN TEG EXCHANGER the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Scrap/Replace in the functional location CLV/FPSOT/COF/CHEM /TO-PSV-75554B the given unit name of INHIB. PUMP B OUTLET PRESS. SAFETY VALVE the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'VIE' in the functional location GIR/FPSOT/COF/INERT/IF97111A, the given unit name NITROGEN FILTER (V), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on SCD + VIE in the functional location GIR/FPSOT/COF/FG /IPN-FG-_470-05-B670 the given unit name of PIPING GROUP FUEL GAS the corresponding item class discipline would be
Piping
Consider the scope on 'Pre-pop test & Recalibration' in the functional location DAL/FPSOT/CRS/AIR /6-PSV-11506D, the given unit name PRES/ SAFETY VALVE, ON MOISTURE SEP/, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on VIE in the functional location PAZ/FPSOH/OIL/STORE/IPN-_HL-HU24-02-B03 the given unit name of Hydrocarbon liquid piping group the corresponding item class discipline would be
Piping
Consider the scope on VII in the functional location CLV/FPSOT/GAS/FLARE/TO-FA-36055 the given unit name of FLAME ARRESTOR, ON VENT 4-VE-TO36055-B49 the corresponding item class discipline would be
Flame Arrestor
Consider the scope on 'VIE' in the functional location GIR/FPSOT/COF/FG /DS802, the given unit name SCRUBBER FUEL GAS BP (V), the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on 'BUOY CHAFFING CHAIN PS/WEAR MEASUR' in the functional location GIR/BUOY /OIL/LOAD /PS MOORING BUOY, the given unit name PS MOORING BUOY SIDE, the corresponding item class discipline would be
FU Items
Consider the scope on VIE in the functional location DAL/FPSOT/OIL/DRAIN/IPN-_DF-0637-65-D513 the given unit name of LINE GROUP,CLOSED DRAIN,DRAIN,CS,IPN the corresponding item class discipline would be
Piping
Consider the scope on UTC + VIE in the functional location PAZ/FPSOH/OIL/DRAIN/IPN-_HL-HU28-05-B05 the given unit name of Hydrocarbon liquid piping group the corresponding item class discipline would be
Piping
Consider the scope on 'GVI' in the functional location DAL/FPSOH/HSG/STRUC/DOUBLE-BOTTOM-TK-AFT, the given unit name DOUBLE BOTTOM TANK, the corresponding item class discipline would be
FU Items
Consider the scope on UTC + VIE in the functional location CLV/FPSOT/CRS/FWAT /IPN-_FW-TO01-03-_92 the given unit name of Fire water piping group the corresponding item class discipline would be
Piping
Consider the scope on 'UTC + VIE' in the functional location DAL/FPSOT/COF/INWAT/IPN-_NW-0641-20-B513, the given unit name LINE GROUP,H2O TREAT,OIL,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on 'PUMP SKID GX304Insp of complet structure' in the functional location GIR/FPSOT/HSG/STRUC/MOD PUMPS SKID GX304, the given unit name STRUCTURAL MODULE DEHYD SKID fr 67-70, the corresponding item class discipline would be
Structure
Consider the scope on UTC + VIE in the functional location PAZ/FPSOH/COF/COOLW/IPC-_CW-HU76-01-_01 the given unit name of Cooling water piping group the corresponding item class discipline would be
Piping
Consider the scope on 'VIE' in the functional location CLV/FPSOT/GAS/COMP /TO-EP-3110-1B, the given unit name of STANDBY LUBE OIL COOLER, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on TO-PSV-250531B-Replace/Scrap in the functional location PAZ/FPSOT/OIL/LOAD /TO-PSV-250531B the given unit name of PRESSURE SAFETY VALVE the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'UTC + VIE' in the functional location DAL/FPSOT/COF/INWAT/IPN-_NW-0641-13-B513, the given unit name LINE GROUP,H2O TREAT,OIL,CS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on VIE in the functional location PAZ/FPSOT/GAS/COMP /TO-V_-3130B the given unit name of LP COMPRESSOR SUCTION SCRUBBER B the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on 'GVI' in the functional location DAL/FPSOH/CRS/FWAT, the given unit name FIRE FIGHTING GENERATION/DISTRIBUTION, the corresponding item class discipline would be
Flame Arrestor
Consider the scope on 'VIE' in the functional location DAL/FPSOT/OIL/SEP /IPC-_GH-0632-01-C513, the given unit name LINE GROUP,OIL HEAT,OILY EFLUENT,CS,IPC, the corresponding item class discipline would be
Piping
Consider the scope on DAL/6-PSV2-52101A-R沤vision in the functional location DAL/FPSOT/GAS/COMP /6-PSV2-52101A the given unit name of PRES. SAFETY VALVE, ON SUCTION SCRUBBER the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'VIE' in the functional location PAZ/FPSOT/WAT/WDEOX/TO-VZ-5320C, the given unit name SRU MEMBRANE HOUSING TRAIN 3, the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on VII in the functional location GIR/FPSOT/OIL/METER/IF312A the given unit name of UA312-FILTER LINE 1 (V) the corresponding item class discipline would be
Pressure Vessel (VII)
Consider the scope on COR - WB3S - CP Measurement in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8612C the given unit name of STARBOARD WING BALLAST 3S the corresponding item class discipline would be
Corrosion Monitoring
Consider the scope on 'UTC + VIE' in the functional location GIR/FPSOT/COF/INERT/IPN-GN-_474-05-C511, the given unit name PIPING GROUP INERT GAS, the corresponding item class discipline would be
Piping
Consider the scope on Pre-Pop test, overhaul & recalibration in the functional location CLV/FPSOT/GAS/COMP /TO-PSV-31309A1 the given unit name of Overhaul - CLV - FPSOT/TO-PSV-31309A1 the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'RB_SB-INSPECTION RISER BALCONY PORTSIDE' in the functional location PAZ/FPSOH/HSG/STRUC/RISER BALCONY SB, the given unit name RISER BALCONY STARBOARD, the corresponding item class discipline would be
Structure
Consider the scope on 'VIE' in the functional location DAL/FPSOT/COF/CHEM /IPN-_XD-0636-05-G580, the given unit name LINE GROUP,CHEM INJECT°,CHEMICAL,SS,IPN, the corresponding item class discipline would be
Piping
Consider the scope on VIE in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0656-08-F513 the given unit name of LINE GROUP,GAS LIFT,GAS,CS,IPN the corresponding item class discipline would be
Piping
Consider the scope on 'Overhaul' in the functional location PAZ/FPSOT/OIL/SEP /TO-PSV4-20145B, the given unit name TO V-2011B PRESSURE SAFETY VALVE, the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + VIE in the functional location PAZ/FPSOT/GAS/DEHYD/IPN-_HG-TO30-02-F03 the given unit name of Hydrocarbon gas piping group the corresponding item class discipline would be
Piping
Consider the scope on Replace/Scrap in the functional location CLV/FPSOT/COF/INERT/TO-PSV-74260B the given unit name of DIE. OIL PUMP B OUTLET PRESS. SAF. VALVE the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on Overhaul in the functional location PAZ/FPSOT/COF/CHEM /TO-PSV-75064B the given unit name of OUTLET PRES SAFETY VALVE B the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on 'FI Visual Inspection of complete struct.' in the functional location CLV/FPSOT/HSG/STRUC/R145-SEC_STR, the given unit name of Secondary structure of R145 Piperack, the corresponding item class discipline would be
Structure
Consider the scope on CLV/HUTZ2875 - Intrusive Major Insp. in the functional location CLV/FPSOH/OIL/DRAIN/HU-TZ-2875 the given unit name of MS BOTTOM STBD FWD BILGE WELL TANK the corresponding item class discipline would be
FU Items
Consider the scope on 'UTC + VIE' in the functional location PAZ/FPSOT/GAS/COMP /IPN-_HG-TO31-12-J21N, the given unit name Fuel gas piping group, the corresponding item class discipline would be
Piping
Consider the scope on VIE+NDT in the functional location CLV/FPSOT/GAS/DEHYD/TO-VZ-3021B the given unit name of GLYCOL REBOILER B the corresponding item class discipline would be
Pressure Vessel (VIE)
Consider the scope on Overhaul in the functional location PAZ/FPSOT/OIL/STAB /TO-PSV-21015B2 the given unit name of HEATER PRESSURE SAFETY VALVE the corresponding item class discipline would be
Pressure Safety Device
Consider the scope on UTC + VIE in the functional location PAZ/FPSOH/OIL/STORE/IPN-_HL-HU24-29-B03 the given unit name of Hydrocarbon liquid piping group the corresponding item class discipline would be
Piping
Consider the scope on 'VIE' in the functional location CLV/FPSOT/WAT/WATLF/TO-EP-5010D, the given unit name of HEAT EXCHANGER D, the corresponding item class discipline would be
Pressure Vessel (VIE)