license: cc-by-nc-sa-4.0 |
|
task_categories: |
|
- audio-classification |
|
tags: |
|
- medical |
|
configs: |
|
- config_name: default |
|
data_files: |
|
- split: csa |
|
path: aware_csa.csv |
|
--- |
|
Acoustic Waveform Airway and Respiratory Examination (AWARE/PTEase) Dataset |
|
=================================================================================================== |
|
|
|
Guidelines |
|
=================================================================================================== |
|
AWARE/PTEase is a smartphone-based sensing system that examines human airway's internal physiological conditions, developed by the Intelligent Systems Laboratory at University of Pittsburgh. AWARE/PTEase probes the airway with acoustic pulses through mouth, and collect the airway's reflections for analysis. Please refer to [our paper](https://doi.org/10.1145/3581791.3596854) and [github repo](https://github.com/pittisl/PTEase) for more details. |
|
|
|
This dataset includes the raw and pre-processed acoustic data of airway measurements collected from 382 human subjects recruited at the Children’s Hospital of Pittsburgh. Demographics of the recruited human subjects are as follows: |
|
| Category | Characteristics | Number | |
|
|--------------------|----------------------|----------------| |
|
| Demographics | Age (years) | 22.55 ± 15.63 | |
|
| | Adults (%) | 166 (43.46) | |
|
| | Female (%) | 205 (53.66) | |
|
| | Caucasian (%) | 287 (75.13) | |
|
| | African-American (%) | 93 (24.35) | |
|
| Body Conditions | Height (cm) | 159.76 ± 15.67 | |
|
| | Weight (kg) | 65.79 ± 27.28 | |
|
| Disease Conditions | Healthy (%) | 115 (30.10) | |
|
| | Asthma (%) | 190 (49.74) | |
|
| | Cystic Fibrosis (%) | 64 (16.75) | |
|
| | COPD (%) | 8 (2.09) | |
|
| | Others (%) | 5 (1.31) | |
|
|
|
The contents of this dataset include three parts: |
|
|
|
- Raw WAV files |
|
|
|
- "aware_raw.zip" |
|
|
|
- Subfolders are named by the subjects' ID (from 1 to 382). In each subfolder, there are three "cali_X.wav" files and multiple "test_X.wav" files |
|
|
|
- "cali_1.wav" : Calibration step 1 - long tube calibration - consists of 12 pairs of received pulses. Each pair contains one wide-band (0-16Hz) pulse and one narrow-band (0-200Hz) pulse. The narrow-band pulses are deperacated and only the wide-band pulses are used. Transmitting period for each pair is 0.4 sec. |
|
|
|
- "cali_2.wav" : Calibration step 2 - standard tube close-end calibration - is the same as above except the calibrations are conducted in a different setting. |
|
|
|
- "cali_3.wav" : Calibration step 3 - standard tube open-end calibration - is the same as above except the calibrations are conducted in a different setting. |
|
|
|
- "test_X.wav" : Test number X - the subject's X-th attempt of conducting the test - follows the protocol of "Nasal breathing -> Inhale -> Exhale -> Inhale -> Exhale -> Inhale -> Exhale". Each segment contains 25 pulses collected at an interval of 0.2 sec. NOTE: Some of the samples have 50 pulses for the "Nasal breathing" phase. |
|
|
|
|
|
- Segmented and aligned acoustic pulses |
|
|
|
- "aware_segmented.pkl" |
|
|
|
- Python pandas.DataFrame saved as a PICKLE file. Same contents as "aware_segmented.csv", but without flattening. |
|
|
|
- To load the data, use the following commands: |
|
|
|
``` python |
|
import pandas as pd |
|
df = pd.read_pickle("aware_segmented.pkl") |
|
``` |
|
- Column 0-45 : Basic subject information, including demographics, clinical measurements and labels. |
|
- Column 0 : Subject ID |
|
- Column 1-9 : Demographics |
|
- Column 10 : Disease label |
|
- Column 11-21 : Impulse Oscillometry Measurements |
|
- Column 22-30 : Spirometry measurements |
|
- Column 31-44 : Spirometry measurements in post-bronchodilator test |
|
- Column 45 : Test number |
|
|
|
- Column 46-55 : Acoustic signals (16-bit PCM, sample rate = 48000) arranged by different phases. Each calibration phase contains 12 measurements and each testing phase contains 25 measurements. Each measurement lasts for 0.1 sec (4800 sample points). |
|
- Column 46 : Phase "Calibration #1". Each element is a [12,4800] NumPy ndarray |
|
- Column 47 : Phase "Calibration #2". Each element is a [12,4800] NumPy ndarray |
|
- Column 48 : Phase "Calibration #3". Each element is a [12,4800] NumPy ndarray |
|
- Column 49 : Phase "Nasal breathing". Each element is a [25,4800] NumPy ndarray |
|
- Column 50 : Phase "Inhale #1". Each element is a [25,4800] NumPy ndarray |
|
- Column 51 : Phase "Inhale #2". Each element is a [25,4800] NumPy ndarray |
|
- Column 52 : Phase "Inhale #3". Each element is a [25,4800] NumPy ndarray |
|
- Column 53 : Phase "Exhale #1". Each element is a [25,4800] NumPy ndarray |
|
- Column 54 : Phase "Exhale #2". Each element is a [25,4800] NumPy ndarray |
|
- Column 55 : Phase "Exhale #3". Each element is a [25,4800] NumPy ndarray |
|
|
|
- "aware_segmented.csv" and "headers.txt" |
|
|
|
- NOTE: Directly loading this CSV file is not recommended. It could be time-consuming and buggy. Try "aware_segmented.pkl" first. |
|
|
|
- NOTE: "aware_segmented.csv" has no headers. See column definition below. |
|
|
|
- Column 0-45 : Basic subject information, including demographics, clinical measurements and labels. |
|
- Column 0 : Subject ID |
|
- Column 1-9 : Demographics |
|
- Column 10 : Disease label |
|
- Column 11-21 : Impulse Oscillometry Measurements |
|
- Column 22-30 : Spirometry measurements |
|
- Column 31-44 : Spirometry measurements in post-bronchodilator test |
|
- Column 45 : Test number |
|
|
|
- Column 46-1012845 : Acoustic signals (16-bit PCM, sample rate = 48000) arranged by different phases. Each calibration phase contains 12 measurements and each testing phase contains 25 measurements. Each measurement lasts for 0.1 sec (4800 sample points). |
|
- Column 46-57645 : Phase "Calibration #1". Flattened from [12,4800] by row-major order. |
|
- Column 57646-115245 : Phase "Calibration #2". Flattened from [12,4800] by row-major order. |
|
- Column 115246-172845 : Phase "Calibration #3". Flattened from [12,4800] by row-major order. |
|
- Column 172846-292845 : Phase "Nasal breathing". Flattened from [25,4800] by row-major order. |
|
- Column 292846-412845 : Phase "Inhale #1". Flattened from [25,4800] by row-major order. |
|
- Column 412846-532845 : Phase "Inhale #2". Flattened from [25,4800] by row-major order. |
|
- Column 532846-652845 : Phase "Inhale #3". Flattened from [25,4800] by row-major order. |
|
- Column 652846-772845 : Phase "Exhale #1". Flattened from [25,4800] by row-major order. |
|
- Column 772846-892845 : Phase "Exhale #2". Flattened from [25,4800] by row-major order. |
|
- Column 892846-1012845 : Phase "Exhale #3". Flattened from [25,4800] by row-major order. |
|
|
|
- Processed airway cross-sectional area (CSA) curves inferred from the acoustic signals |
|
|
|
- "aware_csa.csv" |
|
|
|
- NOTE: Not all raw samples are used for airway CSA reconstructions. Low-quality data is discarded, thus the sample size of this part is smaller than above |
|
|
|
- Column 0-45 : Basic subject information. Same as "aware_segmented.csv". |
|
|
|
- Column 46-129: Reconstructed airway cross-sectional area at different depths from mouth. |
|
|
|
|
|
For more information about this dataset please contact: [email protected] |
|
|
|
Citation |
|
=================================================================================================== |
|
Use of this dataset in publications must be acknowledged by referencing the following publication: |
|
|
|
``` |
|
@inproceedings{yin2023ptease, |
|
title={PTEase: Objective Airway Examination for Pulmonary Telemedicine using Commodity Smartphones}, |
|
author={Yin, Xiangyu and Huang, Kai and Forno, Erick and Chen, Wei and Huang, Heng and Gao, Wei}, |
|
booktitle={Proceedings of the 21st Annual International Conference on Mobile Systems, Applications and Services}, |
|
pages={110--123}, |
|
year={2023}, |
|
url = {https://doi.org/10.1145/3581791.3596854}, |
|
doi = {10.1145/3581791.3596854} |
|
} |
|
``` |
|
|
|
Other Related Publications: |
|
=================================================================================================== |
|
``` |
|
@inproceedings{yin2022out, |
|
title={Out-Clinic Pulmonary Disease Evaluation via Acoustic Sensing and Multi-Task Learning on Commodity Smartphones}, |
|
author={Yin, Xiangyu and Huang, Kai and Forno, Erick and Chen, Wei and Huang, Heng and Gao, Wei}, |
|
booktitle={Proceedings of the 20th ACM Conference on Embedded Networked Sensor Systems}, |
|
pages={1182--1188}, |
|
year={2022}, |
|
url = {https://doi.org/10.1145/3560905.3568437}, |
|
doi = {10.1145/3560905.3568437} |
|
} |
|
``` |
|
|
|
License |
|
=================================================================================================== |
|
[![CC BY-NC-SA 4.0][cc-by-nc-sa-shield]][cc-by-nc-sa] |
|
|
|
This work is licensed under a |
|
[Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License][cc-by-nc-sa]. |
|
|
|
[![CC BY-NC-SA 4.0][cc-by-nc-sa-image]][cc-by-nc-sa] |
|
|
|
[cc-by-nc-sa]: http://creativecommons.org/licenses/by-nc-sa/4.0/ |
|
[cc-by-nc-sa-image]: https://licensebuttons.net/l/by-nc-sa/4.0/88x31.png |
|
[cc-by-nc-sa-shield]: https://img.shields.io/badge/License-CC%20BY--NC--SA%204.0-lightgrey.svg |
|
|