Unnamed: 0
int64 0
5k
| description
stringlengths 1
492
| medical_specialty
stringclasses 40
values | sample_name
stringlengths 5
69
| transcription
stringlengths 11
18.4k
⌀ | keywords
stringlengths 1
916
⌀ |
---|---|---|---|---|---|
1,200 | Austin-Akin bunionectomy with internal screw fixation of the first right metatarsophalangeal joint. Weil osteotomy with internal screw fixation, first right metatarsal. Arthroplasty, second right PIP joint. | Surgery | Austin-Akin Bunionectomy | TITLE OF OPERATION:,1. Austin-Akin bunionectomy with internal screw fixation of the first right metatarsophalangeal joint.,2. Weil osteotomy with internal screw fixation, first right metatarsal.,3. Arthroplasty, second right PIP joint.,PREOPERATIVE DIAGNOSES:,1. Bunion deformity, right foot.,2. Dislocated second right metatarsophalangeal joint.,3. Hammertoe deformity, second right digit.,POSTOPERATIVE DIAGNOSES:,1. Bunion deformity, right foot.,2. Dislocated second right metatarsophalangeal joint.,3. Hammertoe deformity, second right digit.,ANESTHESIA:, Monitored anesthesia care with 20 mL of 1:1 mixture of 0.5% Marcaine and 1% lidocaine plain.,HEMOSTASIS:, 60 minutes, a right ankle tourniquet set at 250 mmHg.,ESTIMATED BLOOD LOSS: , Less than 10 mL.,PREOPERATIVE INJECTABLES: ,1 g Ancef IV 30 minutes preoperatively.,MATERIALS USED: , 3-0 Vicryl, 4-0 Vicryl, 5-0 Prolene, as well as two 16-mm partially treaded cannulated screws of the OsteoMed system, one 18-mm partially treaded cannulated screw of the OsteoMed system of the 3.0 size. One 10-mm 2.0 partially threaded cannulated screw of the OsteoMed system.,DESCRIPTION OF THE PROCEDURE: ,The patient was brought to the operating room and placed on the operating table in the supine position. After adequate sedation was achieved by the anesthesia team, the above-mentioned anesthetic mixture was infiltrated directly into the patient's right foot to anesthetize the future surgical sites. The right ankle was covered with cast padding and an 18-inch ankle tourniquet was placed around the right ankle and set up at 250 mmHg. The right foot was then prepped, scrubbed, and draped in a normal sterile technique. The right ankle tourniquet was then inflated. Attention was then directed on the dorsomedial aspect of the first right metatarsophalangeal joint where a 6-cm linear incision was placed parallel and medial to the course of the extensor hallucis longus tendon to the right great toe. The incision was deepened through subcutaneous tissues. All the bleeders were identified, cut, clamped, and cauterized. The incision was deepened to the level of the capsule and the periosteum of the first right metatarsophalangeal joint. All the tendinous and neurovascular structures were identified and retracted from the site to be preserved. Using sharp and dull dissection, the periosteal and capsular tissues were mobilized from the head and neck of the first right metatarsal and the base of the proximal phalanx of the right great toe. The conjoint tendon was identified on the lateral plantar aspect of the base of the proximal phalanx and resected transversely.,A lateral capsulotomy was also performed at the level of the first right metatarsophalangeal joint. Using sharp and dull dissection, the dorsomedial prominence of the first right metatarsal head was adequately exposed and resected with the use of a sagittal saw. The same saw was used to perform the Austin osteotomy on the capital aspect of the first right metatarsal with its apex distal and its base proximal. The dorsal arm of the osteotomy was longer than the plantar arm and noted to accommodate for the future internal fixation. The capital fragment of the first right metatarsal was then transposed laterally and impacted on the shaft of the first right metatarsal. Two wires of the OsteoMed system were also used as provisional fixation wires and also as guidewires for the insertion of the future screws. The wires were inserted dorsal distal to plantar proximal through the dorsal arm of the osteotomy. The two screws from the 3.0 OsteoMed system were inserted over the wires using AO technique. One screw measured 16 mm, second screw measured 18 mm in length. Both 3.0 screws were then evaluated for the fixation of the osteotomy after the wires were removed. Fixation of the osteotomy was found to be excellent. The dorsomedial prominence of the first right metatarsal shaft was then resected with the sagittal saw. To improve the correction of the hallux abductus angle, an Akin osteotomy was also performed on the base of the proximal phalanx of the right great toe with its base medially and its apex laterally. Upon removal of the base wedge from the base of the proximal phalanx, the osteotomy was reduced with the OsteoMed smooth wire, which was also used as a guidewire for the insertion of a 16-mm partially threaded cannulated screw from the OsteoMed 3.0 system. Upon insertion of the screw, using AO technique, the wire was removed. The screw was inserted proximal medial to distal lateral through the osteotomy of the base of the proximal phalanx of the right great toe. Fixation of the osteotomy was found to be excellent. Reduction of the bunion deformity was also found to be excellent and position of the first right metatarsophalangeal joint was found to be anatomical. Range of motion of that joint was uninhibited. The area was flushed copiously with saline. Then, 3-0 suture material was used to approximate the periosteum and capsular tissues, 4-0 was used to approximate the subcutaneous tissues, and Steri-Strips were used to reinforce the incision. Attention was directed over the neck of the second right metatarsal head where a 3-cm linear incision was placed directly over the surgical neck of the second right metatarsal. The incision was deepened through subcutaneous tissues. All the bleeders were identified, cut, clamped and cauterized. The incision was deepened through the level of the periosteum over the surgical neck of the second right metatarsal. All the tendinous and neurovascular structures were identified and retracted from the site to be preserved. Using sharp and dull dissection, the surgical neck of the second right metatarsal was adequately exposed and then Weil-type osteotomy was performed from dorsal distal to plantar proximal through the surgical neck of the second right metatarsal. The capital fragment was then transposed proximally and impacted on the shaft of the second right metatarsal.,The 2.0 Osteo-Med system was also used to fixate this osteotomy wire from that system was inserted dorsal proximal to plantar distal through the second right metatarsal osteotomy and the wire was used as a guidewire for the insertion of the 10-mm partially threaded 2.0 cannulated screw. Upon insertion of the screw, using AO technique, the wire was then removed. Fixation of the osteotomy with 2.0 screw was found to be excellent. The second right metatarsophalangeal joint was then relocated and the dislocation of that joint was completely reduced. Range of motion of the second right metatarsophalangeal joint was found to be excellent. Then, 3-0 Vicryl suture material was used to approximate the periosteal tissues. Then, 4-0 Vicryl was used to approximate the skin incision. Attention was then directed at the level of the PIP joint of the second right toe where two semi-elliptical incisions were placed directly over the bony prominence at the level of the second right PIP joint. The island of skin between the two semi-elliptical incisions was resected in toto. The dissection was carried down to the level of extensor digitorum longus of the second right toe, which was resected transversely at the level of the PIP joint. A capsulotomy and a medial and lateral collateral ligament release of the PIP joint of the second right toe was also performed and head of the proximal phalanx of the second right digit was adequately exposed. Using the double-action bone cutter, the head of the proximal phalanx of the second right toe was then resected. The area was copiously flushed with saline. The capsular and periosteal tissues were approximated with 2-0 Vicryl and 3-0 Vicryl suture material was also used to approximate the extensor digitorum longus to the second right toe. A 5-0 Prolene was used to approximate the skin edges of the two semi-elliptical incisions. Correction of the hammertoe deformity and relocation of the second right metatarsophalangeal joint were evaluated with the foot loaded and were found to be excellent and anatomical. At this time, the patient's three incisions were covered with Xeroform, copious amounts of fluff and Kling, stockinette, and Ace bandage. The patient's right ankle tourniquet was deflated, time was 60 minutes. Immediate hyperemia was noted on the entire right lower extremity upon deflation of the cuffs.,The patient's right foot was placed in a surgical shoe and the patient was transferred to the recovery room under the care of anesthesia team with the vital signs stable and the vascular status at appropriate levels. The patient was given instructions and education on how to continue caring for her right foot surgery. The patient was eventually discharged from Hospital according to nursing protocol and was advised to follow up with Dr. X's office in one week's time for her first postoperative appointment. | surgery, austin-akin bunionectomy, weil osteotomy, internal screw fixation, first right metatarsal, metatarsophalangeal joint, hammertoe deformity, extensor digitorum longus, austin akin bunionectomy, threaded cannulated screw, semi elliptical incisions, ankle tourniquet, surgical neck, cannulated screws, pip joint, proximal phalanx, fixation, metatarsophalangeal, proximal, screw, metatarsal, osteotomy, austin, joint, tourniquet, osteomed, phalanx, incision, |
1,201 | Erythema of the right knee and leg, possible septic knee. Aspiration through the anterolateral portal of knee joint. | Surgery | Aspiration - Knee Joint | PREOPERATIVE DIAGNOSES: , Erythema of the right knee and leg, possible septic knee.,POSTOPERATIVE DIAGNOSES:, Erythema of the right knee superficial and leg, right septic knee ruled out.,INDICATIONS: , Mr. ABC is a 52-year-old male who has had approximately eight days of erythema over his knee. He has been to multiple institutions as an outpatient for this complaint. He has had what appears to be prepatellar bursa aspirated with little to no success. He has been treated with Kefzol and 1 g of Rocephin one point. He also reports, in the emergency department today, an attempt was made to aspirate his actual knee joint which was unsuccessful. Orthopedic Surgery was consulted at this time. Considering the patient's physical exam, there is a portal that would prove to be outside of the erythema that would be useful for aspiration of the knee. After discussion of risks and benefits, the patient elected to proceed with aspiration through the anterolateral portal of his knee joint.,PROCEDURE: ,The patient's right anterolateral knee area was prepped with Betadine times two and a 20-gauge spinal needle was used to approach the knee joint approximately 3 cm anterior and 2 cm lateral to the superolateral pole of the patella. The 20-gauge spinal needle was inserted and entered the knee joint. Approximately, 4 cc of clear yellow fluid was aspirated. The patient tolerated the procedure well.,DISPOSITION: , Based upon the appearance of this synovial fluid, we have a very low clinical suspicion of a septic joint. We will send this fluid to the lab for cell count, crystal exam, as well as culture and Gram stain. We will follow these results. After discussion with the emergency department staff, it appears that they tend to try to treat his erythema which appears to be cellulitis with IV antibiotics. | surgery, knee and leg, anterolateral portal, emergency department, spinal needle, septic knee, knee joint, knee, emergency, department, gauge, spinal, needle, aspiration, anterolateral, portal, aspirated, fluid, septic, erythema, joint, aspiraion, |
1,202 | Ash split venous port insertion. The right anterior chest and supraclavicular fossa area, neck, and left side of chest were prepped with Betadine and draped in a sterile fashion. | Surgery | Ash Split Venous Port | ASH SPLIT VENOUS PORT,PROCEDURE DETAILS: ,The patient was taken to the operating room and placed in supine position and monitored anesthesia care provided by the anesthetist. The right anterior chest and supraclavicular fossa area, neck, and left side of chest were prepped with Betadine and draped in a sterile fashion. Xylocaine 1% was infiltrated in the supraclavicular area and anterior chest along the planned course of the catheter. The patient was placed into Trendelenburg position.,The right internal jugular vein was accessed by a supraclavicular 19-gauge, thin-walled needle as demonstrated by easy withdrawal of venous blood on the first pass of the needle. Under fluoroscopic control, a J-wire was advanced into the right atrium. The needle was removed and the skin puncture site enlarged to about 8 mm with the scalpel. A second incision was made 5 cm inferior to the right midclavicular line, through which an Ash split catheter was advanced, using the tunneling rod, in a gently curving pass to exit the skin of the neck incision. The tunneling needle was removed and the catheter split up to the marker as indicated in the recommended use of the catheter.,Sequential dilators were advanced over the J-wire under fluoroscopic control to dilate the subcutaneous tunnel followed by advancement of a dilator and sheath into the right superior vena cava under fluoroscopic control. The dilator and wire were removed, leaving the sheath in position, through which a double-lumen catheter was advanced into the central venous system. The sheath was peeled away, leaving the catheter into position. Each port of the catheter was flushed with dilute heparinized saline.,The patient was returned to the flat position. The catheter was secured to the skin of the anterior chest using 2-0 Ethilon suture placed through the suture "wings.",The neck incision was closed with 3-0 Vicryl subcuticular closure and pressure dressing applied. Fluoroscopic examination of the chest revealed no evidence of pneumothorax upon completion of the procedure and the catheter was in excellent position.,The patient was returned to the recovery room for postoperative care. | surgery, ash split venous port, venous port, anterior chest, incision, dilators, sheath, port, supraclavicular, needle, fluoroscopic, venous, insertion, catheter |
1,203 | Hemarthrosis, left knee, status post total knee replacement, rule out infection. Arthrotomy, irrigation and debridement, and polyethylene exchange, left knee. No complications were encountered throughout the procedure. | Surgery | Arthrotomy & I&D | PREOPERATIVE DIAGNOSIS: , Hemarthrosis, left knee, status post total knee replacement, rule out infection.,POSTOPERATIVE DIAGNOSIS: , Hemarthrosis, left knee, status post total knee replacement, rule out infection.,OPERATIONS:,1. Arthrotomy, left total knee.,2. Irrigation and debridement, left knee.,3. Polyethylene exchange, left knee.,COMPLICATION: , None.,TOURNIQUET TIME: ,58 minutes.,ESTIMATED BLOOD LOSS: , Minimal.,ANESTHESIA: ,General.,INDICATIONS: ,This patient underwent an uncomplicated left total knee replacement. Postoperatively, unfortunately did not follow up with PT/INR blood test and he was taking Coumadin. His INR was seemed to elevated and developed hemarthrosis. Initially, it did look very benign, although over the last 24 hours it did become irritable and inflamed, and he therefore was indicated with the above-noted procedure.,This procedure as well as alternatives was discussed in length with the patient and he understood them well. Risks and benefits were also discussed. Risks such as bleeding, infection, damage to blood vessels, damage to nerve roots, need for further surgeries, chronic pain with range of motion, risk of continued discomfort, risk of need for further reconstructive procedures, risk of need for total knee revision, risk of blood clots, pulmonary embolism, myocardial infarction, and risk of death were discussed. He understood them well. All questions were answered and he signed consent for the procedure as described.,DESCRIPTION OF PROCEDURE: , The patient was placed on operating table and general anesthesia was achieved. The left lower extremity was then prepped and draped in the usual sterile manner. The leg was elevated and the tourniquet was inflated to 325 mmHg. A longitudinal incision was then made and carried down through subcutaneous tissues. This was made through the prior incision site. There were some fatty necrotic tissues through the incision region and all necrotic tissue was debrided sharply on both sides of the incision site. Medial and lateral flaps were then made. The prior suture was identified, the suture removed and then a medial parapatellar arthrotomy was then performed. Effusion within the knee was noted. All hematoma was evacuated. I then did flex the knee and removed the polyethylene. Once the polyethylene was removed I did irrigate the knee with total of 9 liters of antibiotic solution. Further debridement was performed of all inflamed tissue and thickened synovial tissue. A 6 x 16-mm Stryker polyethylene was then snapped back in position. The knee has excellent stability in all planes and I did perform a light manipulation to improve the flexion of the knee. Further irrigation was performed on the all soft tissue in the knee with additional 3 liters of normal saline. The knee was placed in a flexed position and the extensor mechanism was reapproximated using #2 Ethibond suture in a figure-of-eight manner. The subcutaneous tissue was reapproximated in layers using #1 and 2-0 Vicryl sutures, and the skin was reapproximated using staples. Prior to closure a Hemovac drain was inserted through a superolateral approach into the knee joint.,No complications were encountered throughout the procedure, and the patient tolerated the procedure well. The patient was taken to recovery room in stable condition. | surgery, |
1,204 | Arthroscopy of the left knee, left arthroscopic medial meniscoplasty of medial femoral condyle, and chondroplasty of the left knee as well. Chondromalacia of medial femoral condyle. Medial meniscal tear, left knee. | Surgery | Arthroscopy, Meniscoplasty, & Chondroplasty | PREOPERATIVE DIAGNOSIS:, Medial meniscal tear, left knee.,POSTOPERATIVE DIAGNOSIS: , Chondromalacia of medial femoral condyle.,PROCEDURE PERFORMED:,1. Arthroscopy of the left knee.,2. Left arthroscopic medial meniscoplasty of medial femoral condyle.,3. Chondroplasty of the left knee as well.,ESTIMATED BLOOD LOSS: , 80 cc.,TOTAL TOURNIQUET TIME: , 19 minutes.,DISPOSITION: , The patient was taken to PACU in stable condition.,HISTORY OF PRESENT ILLNESS: ,The patient is a 41-year-old male with left knee pain for approximately two years secondary to hockey injury where he did have a prior MCL sprain. He has had a positive symptomology of locking and pain since then. He had no frank instability to it, however.,GROSS OPERATIVE FINDINGS: , We did find a tear to the medial meniscus as well as a large area of chondromalacia to the medial femoral condyle.,OPERATIVE PROCEDURE: ,The patient was taken to the operating room. The left lower extremity was prepped and draped in the usual sterile fashion. Tourniquet was applied to the left thigh with adequate Webril padding, not inflated at this time. After the left lower extremity had been prepped and draped in the usual sterile fashion, we applied an Esmarch tourniquet, exsanguinating the blood and inflated the tourniquet to 325 mmHg for a total of 19 minutes. We established the lateral port of the knee with #11 blade scalpel. We put in the arthroscopic trocar, instilled with water and inserted the camera.,On inspection of the patellofemoral joint, it was found to be quite smooth. Pictures were taken there. There was no evidence of chondromalacia, cracking, or fissuring of the articular cartilage. The patella was well centered over the trochlear notch. We then directed the arthroscope to the medial compartment of the knee. It was felt that there was a tear to the medial meniscus. We also saw large area of chondromalacia with grade-IV changes to bone over the medial femoral condyle. This area was debrided with forceps and the arthroscopic shaver. The cartilage was also smoothened over the medial femoral condyle. This was curetted after the medial meniscus had been trimmed. We looked into the notch. We saw the ACL appeared stable, saw attachments to tibial as well as the femoral insertion with some evidence of laxity, wear and tear. Attention then was taken to the lateral compartment with some evidence of tear to the lateral meniscus and the arterial surface of both the tibia as well as the femur were pristine in the lateral compartment. All instruments were removed. All loose cartilaginous pieces were suctioned from the knee and water was suctioned at the end. We removed all instruments. Marcaine was injected into the portal sites. We placed a sterile dressing and stockinet on the left lower extremity. He was transferred to the gurney and taken to PACU in stable condition. | surgery, medial meniscoplasty, arthroscopic, chondroplasty, arthroscopy, medial femoral condyle, medial meniscus, knee, meniscal, cartilage, meniscoplasty, meniscus, chondromalacia, condyle, femoral |
1,205 | Arthrotomy, removal humeral head implant, right shoulder. Repair of torn subscapularis tendon (rotator cuff tendon) acute tear. Debridement glenohumeral joint. Biopsy and culturing the right shoulder. | Surgery | Arthrotomy & Subscapularis Tendon Repair | TITLE OF OPERATION: ,1. Arthrotomy, removal humeral head implant, right shoulder.,2. Repair of torn subscapularis tendon (rotator cuff tendon) acute tear.,3. Debridement glenohumeral joint.,4. Biopsy and culturing the right shoulder.,INDICATION FOR SURGERY: , The patient had done well after a previous total shoulder arthroplasty performed by Dr. X. However, the patient was lifted with subsequent significant pain and apparent tearing of his subscapularis. Risks and benefits of the procedure had been discussed with the patient at length including, but not exclusive of infection, nerve or artery damage, stiffness, loss of range of motion, incomplete relief of pain, incomplete return of function, continued instability, retearing of the tendon, need for revision of his arthroplasty, permanent nerve or artery damage, etc. The patient understood and wished to proceed.,PREOP DIAGNOSIS: ,1. Torn subscapularis tendon, right shoulder.,2. Right total shoulder arthroplasty (Biomet system).,POSTOP DIAGNOSIS: ,1. Torn subscapularis tendon, right shoulder.,2. Right total shoulder arthroplasty (Biomet system).,3. Diffuse synovitis, right shoulder.,PROCEDURE: , The patient was anesthetized in the supine position. A Foley catheter was placed in his bladder. He was then placed in a beach chair position. He was brought to the side of the table and the torso secured with towels and tape. His head was then placed in the neutral position with no lateral bending or extension. It was secured with paper tape over his forehead. Care was taken to stay off his auricular cartilages and his orbits. Right upper extremity was then prepped and draped in the usual sterile fashion. The patient was given antibiotics well before the beginning of the procedure to decrease any risk of infection. Once he had been prepped and draped with the standard prep, he was prepped a second time with a chlorhexidine-type skin prep. This was allowed to dry and the skin was then covered with Ioban bandages also to decrease his risk of infection.,Also, preoperatively, the patient had his pacemaker defibrillator function turned off as a result during this case. Bipolar type cautery had to be used as opposed to monopolar cautery.,The patient's deltopectoral incision was then opened and extended proximally and distally. The patient had significant amount of scar already in this interval. Once we got down to the deltoid and pectoralis muscle, there was no apparent cephalic vein present, as a result the rotator cuff interval had to be developed through an area of scar. This created a significant amount of bleeding. As a result a very slow and meticulous dissection was performed to isolate his coracoid and then his proximal humerus. Care was taken to stay above the pectoralis minor and the conjoint tendon. The deltoid had already started to scar down the proximal humerus as a result a very significant amount of dissection had to be performed to release the deltoid from proximal humerus. Similarly, the deltoid insertion had to be released approximately 50% of its width to allow us enough mobility of the proximal humerus to be able to visualize the joint or the component. It was clear that the patient had an avulsion of the subscapularis tendon as the tissue on the anterior aspect of the shoulder was very thin. The muscle component of the subscapularis could be located approximately 1 cm off the glenoid rim and approximately 3 cm off the lesser tuberosity. The soft tissue in this area was significantly scarred down to the conjoint tendon, which had to be very meticulously released. The brachial plexus was identified as was the axillary nerve. Once this was completed, an arthrotomy was then made leaving some tissue attached to the lesser tuberosity in case it was needed for closure later. This revealed sanguineous fluid inside the joint. We did not feel it was infected based upon the fluid that came from the joint. The sutures for the subscapularis repair were still located in the proximal humerus with no tearing through the bone, which was fortunate because in that we could use the bone later for securing the sutures. The remaining sutures were seen to be retracted medially to an area of the subscapularis as mentioned previously. Some more capsule had to be released off the inferior neck in order for us to gain exposure during the scarring. This was done also very meticulously. The upper one half of the latissimus dorsi tendon was also released. Once this was completed, the humerus could be subluxed enough laterally that we could remove the head. This was done with no difficulty. Fortunately, the humeral component stayed intact. There were some exudates beneath the humeral head, which were somewhat mucinous. However, these do not really appear to be infected, however, we sent them to pathology for a frozen section. This frozen section later returned as possible purulent material. I discussed this personally with the pathologist at that point. We told him that the procedure is only 3 weeks old, but he was concerned that there might be more white blood cells in the tissue than he would expect. As a result, all the mucinous exudates were carefully removed. We also performed a fairly extensive synovectomy of the joint primarily to gain vision of the components, but also we irrigated the joint throughout the case with antibiotic impregnated irrigation. At that point, we also had sent portions of this mucinous material to pathology for a stat Gram stain. This came back as no organisms seen. We also sent portions for culture and sensitivity both aerobic and anaerobic.,Once this was completed, attention was then directed to the glenoid. The patient had significant amount of scar already. The subscapularis itself was significantly scarred down to the anterior rim. As a result, the adhesions along the anterior edge were released using a knife. Also adhesions in the subcoracoid space area were released very carefully and meticulously to prevent any injury to the brachial plexus. Two long retractors were placed medially to protect the brachial plexus during all portions of suturing of the subscapularis. The subscapularis was then tagged with multiple number 2 Tycron sutures. Adhesions were released circumferentially and it was found that with the arm in internal rotation about neutral degrees, the subscapularis could reach the calcar region without tension. As a result, seven number 2 Tycron sutures were placed from the bicipital groove all the way down to the inferior calcar region of the humerus. These all had excellent security in bone. Once the joint had been debrided and irrigated, the real humeral head was then placed back on the proximal humerus. Care was taken to remove fluid off the Morse taper. The head was then impacted. It should be noted that we tried multiple head sizes to see if a smaller or larger head size might be more appropriate for this patient. Unfortunately, any of the larger head sizes would overstep the joint and any smaller sizes would not give good coverage to the proximal humerus. As a result, it was felt to place the offset head back on the humerus, we did insert a new component as opposed to using the old component. The old component was given to the family postoperatively.,With the arm in internal rotation, the Tycron sutures were then placed through the subscapularis tendon in the usual horizontal mattress fashion. Also, it should be noted that the rotator cuff interval had to be released as part of the exposure. We started the repair by closing the rotator cuff interval. Anterior and posterior translation was then performed and was found to be very stable. The remaining sutures were then secured through the subscapularis tendon taking care to make sure that very substantial bites were obtained. This was then reinforced with the more flimsy tissue laterally being sewn into the tissue around the bicipital tuberosity essentially provided us with a two-layer repair of the subscapularis tendon. After the tendon had been repaired, there was no tension on repair until 0 degrees external rotation was reached with the arm to the side. Similarly with the arm abducted 90 degrees, tension was on repair at 0 degrees of external rotation. It should be noted that the wound was thoroughly irrigated throughout with antibiotic impregnated irrigation. The rotator cuff interval was closed with multiple number 2 Tycron sutures. It was reinforced with 0 Vicryl sutures. Two Hemovac drains were then placed inferiorly at the deltoid. The deltopectoral interval was then closed with 0 Vicryl sutures. A third drain was placed in the subcutaneous tissues to prevent any infections or any fluid collections. This was sewn into place with the drain pulled out superiorly. Once all the sutures have been secured and the drain visualized throughout this part of the closure, the drain was pulled distally until it was completely covered. There were no signs that it had been tagged or hung up by any sutures.,The superficial subcutaneous tissues were closed with interrupted with 2-0 Vicryl sutures. Skin was closed with staples. A sterile bandage was applied along with a cold therapy device and a shoulder immobilizer. The patient was sent to the intensive care unit in stable and satisfactory condition.,Due to the significant amount of scar and bleeding in this patient, a 22 modifier is being requested for this case. This was a very difficult revision case and was significantly increased in technical challenges and challenges in the dissection and exposure of this implant compared to a standard shoulder replacement. Similarly, the repair of the subscapularis tendon presented significantly more challenges than that of a standard rotator cuff repair because of the implant. This was being dictated for insurance purposes only and reflects no inherent difficulties with this case. The complexity and the time involved in this case was approximately 30% greater than that of a standard shoulder replacement or of a rotator cuff repair. This is being dictated to indicate this was a revision case with significant amount of scar and bleeding due to the patient's situation with his pacemaker. This patient also had multiple medical concerns, which increased the complexity of this case including the necessity to place him in intensive care unit postoperatively for observation. | surgery, arthrotomy, repair of torn subscapularis tendon, glenohumeral joint, biomet system, arthroplasty, diffuse synovitis, proximal humerus, torn subscapularis tendon, subscapularis tendon, rotator cuff, humerus, sutures, tendon, head, shoulder, subscapularis, torn, |
1,206 | Diagnostic arthroscopy exam under anesthesia, left shoulder. Debridement of chondral injury, left shoulder. Debridement, superior glenoid, left shoulder. Arthrotomy. Bankart lesion repair. Capsular shift, left shoulder (Mitek suture anchors; absorbable anchors with nonabsorbable sutures). | Surgery | Arthroscopy, Arthrotomy, Bankart lesion repair | TITLE OF OPERATION:,1. Diagnostic arthroscopy exam under anesthesia, left shoulder.,2. Debridement of chondral injury, left shoulder.,3. Debridement, superior glenoid, left shoulder.,4. Arthrotomy.,5. Bankart lesion repair.,6. Capsular shift, left shoulder (Mitek suture anchors; absorbable anchors with nonabsorbable sutures).,INDICATION FOR SURGERY: , The patient was seen multiple times preoperatively and found to have chronic instability of her shoulder. Risks and benefits of the procedure had been discussed in length including but not exclusive of infection, nerve or artery damage, stiffness, loss of range of motion, incomplete relief of pain, continued instability, recurrent instability, medical complications, surgical complications, and anesthesia complications. The patient understood and wishes to proceed.,PREOP DIAGNOSIS: , Anterior instability, left shoulder.,POSTOP DIAGNOSES:,1. Anterior instability, left shoulder.,2. Grade 4 chondromalacia, 10% humeral head, chondral defect 1 cm squared, left shoulder.,3. Type 1 superior labrum anterior and posterior lesion, left shoulder.,4. Anteroinferior glenoid erosions 10% bony surface, left shoulder.,5. Bankart lesion, left shoulder.,PROCEDURE: , The patient was placed in a supine position and both shoulders examined systematically. She had full range of motion with no joint adhesions. She had equal range of motion bilaterally. She had Hawkins 2 anteriorly and posteriorly in both shoulders with a grade 1 sulcus sign in both shoulders. This was the same when the arm was in neutral or in external rotation. The patient was then turned to right lateral decubitus position, axillary roll was placed, and beanbag was inflated. Peroneal nerve was well protected. All bony prominences were well protected.,The left upper extremity was then prepped and draped in the usual sterile fashion. The patient was given antibiotics well before the start of the procedure to decrease the risk of infection. The arm was placed in a arm holder with 10 pounds of traction. A posterior portal was created in the usual manner by isolating gently with the spinal needle, it was insufflated with 30 cubic centimeters of saline. A small incision was made after infiltrating the skin with Marcaine and epinephrine. The scope was introduced into the shoulder with no difficulty. It was then examined systematically. The patient did have diffuse synovitis throughout her shoulder. Her posterior humeral head showed an enlarged bold spot with some other areas of chondromalacia on the posterior head. She also had an area 1 cm in diameter, which was on more central portion of the head and more inferiorly which appeared to be more of an impaction-type injury. This had some portions of fibrillated and loose cartilage, hanging from the edges. These were later debrided, but the dissection was proximally 10 to 15% of the humeral surface.,The biceps tendon appeared to be normal. The supraspinatus, infraspinatus tendons were normal. The inferior pouch was normal with no capsular tearing and no HAGL lesions. The posteroinferior labrum was normal as well as the posterosuperior labrum. There was some fraying in the posterosuperior labrum, which was later debrided. It was found essentially to be a type 1 lesion anteriorly and superiorly. The anterosuperior labrum appeared to be detached, which appeared to be more consistent with a sublabral hole. The middle glenohumeral ligament was present as an entire sheath, but attach to the labrum. The labrum did appeared to be detached from the anterior glenoid from the 11 o'clock position all the way down to the 6 o'clock position. The biceps anchor itself was later probed and found to be stable and normal. The subscapularis tendon was normal. The anterior band of the glenohumeral ligament was present, but it was clearly avulsed off the glenoid. There was some suggestion of anteroinferior bony erosions, which was later substantiated when the shoulder was opened. The patient was missing about 10 to 15% of her anteroinferior glenoid rim. The patient had a positive drive-through sign.,The arm was then moved to lateral and placed through range of motion. There was contact of the rotator cuff to the superior glenoid in flexion at 115 degrees, maximum flexion was 150 degrees. The arm abducted and externally rotated. There was contact to the rotator cuff with posterosuperior labrum. This occurred with the arm position of 90 degrees with abduction at 55 degrees of external rotation. It should be noted that the maximum abduction is 150 degrees and with the arm abducted 90 degrees, maximum external rotation was 95 degrees. The patient did have a positive relocation maneuver. The posterior labrum did appear to tilt-off, but did not appear to peel off.,The arm was then placed back in the arm holder. Anterior portal was created with Wissinger rod. A blue cannula was inserted into the shoulder without difficulty. Shaver was introduced in the labrum. Also the area of chondromalacia as mentioned above was debrided. The labrum was found to be stable with only a type 1 SLAP lesion, and there was no evidence as there was really a type 2 SLAP lesion. The instruments were then removed along with excess fluid. The posterior portals were closed with single 4-0 nylon suture. The anterior portal was left open. The patient was then placed in a supine position, and the extremity was reprepped and draped in anticipation of performing open capsular shift.,The patient's anterior incision made just lateral to the coracoid in the skin line. Mediolateral skin flaps were developed, and cephalic vein was identified and protected throughout the case. The interval was developed down the clavipectoral fascia. The conjoined tendon was retracted medially and the deltoid laterally. The patient's subscapularis was intact, and the subscapularis split was then made between the upper one half and lower one half in line with muscle fibers. The capsule could easily be detached from the muscle, and the interval developed very easily. A retractor was placed inferiorly to protect the axillary nerve. Then Gelpi retractor was used to hold the subscapularis split open.,Next, an arthrotomy was made down at the 9 o'clock position. The labrum was identified and found to be attached all the way down to 6 o'clock position. The inferior flap was then created in a usual manner and tied with a 0 Vicryl suture. The patient's glenoid rim did have some erosion as mentioned above with some bone loss and flattening. This was debrided with the soft tissue. Three Mitek suture anchors were then placed into the glenoid rim right at the margin of articular cartilage to the scapular neck. These were absorbable anchors with nonabsorbable sutures. They had excellent fixation once they had been placed.,Next, the capsular shift and Bankart repair were performed in the usual manner with the number 2 Ti-Cron sutures as an outside in and then inside out technique. This brought the capsule right up to the edge of the glenoid rim. With the arm in internal rotation and posterior pressure on the head, the capsule was then secured to the rim with no difficulty under direct visualization. The capsule did come right up into the joint as expected with this type of repair. The superior flap was then closed, the inferior flap over the superior anchor. The interval between two flaps was closed with multiple number 2 Ti-Cron sutures. Once this has been completed, there was no tension on the repair with the arm to side until 10 degrees of external rotation was reached. The arm abducted 90 degrees. There was tension on the repair until 20 degrees of external rotation reached.,The wound was thoroughly irrigated throughout with antibiotic-impregnated irrigation. The subscapularis split was closed with interrupted 0 Vicryl sutures. The deep subcutaneous tissues were closed with interrupted 0 Vicryl sutures. The superficial subcutaneous tissues were closed with number 2-0 Vicryl sutures. The skin was closed with 4-0 subcuticular Prolene, reinforced with Steri-Strips. A sterile bandage was applied along with a cold therapy device and a shoulder immobilizer. The patient was sent to the recovery room in stable and satisfactory condition. | surgery, diagnostic arthroscopy, chondral injury, debridement, superior glenoid, arthrotomy, bankart lesion, capsular shift, mitek suture, absorbable anchors, anterior instability, chondromalacia, superior labrum, glenoid erosion, glenoid rim, external rotation, glenoid, labrum, shoulder, arthroscopy, |
1,207 | Excision of capsular mass and arthrotomy with ostectomy of lateral femoral condyle, right knee. Soft tissue mass and osteophyte lateral femoral condyle, right knee. | Surgery | Arthrotomy & Ostectomy & Capsular Mass Excision | PREOPERATIVE DIAGNOSIS:, Soft tissue mass, right knee.,POSTOPERATIVE DIAGNOSES:,1. Soft tissue mass, right knee.,2. Osteophyte lateral femoral condyle, right knee.,PROCEDURES PERFORMED:, Excision of capsular mass and arthrotomy with ostectomy of lateral femoral condyle, right knee.,SPECIFICATION: , The entire operative procedure was done in Inpatient Operating Suite, room #1 at ABCD General Hospital. This was done under a local and IV sedation via the Anesthesia Department.,HISTORY AND GROSS FINDINGS:, This is a 37-year-old African-American male with a mass present at the posterolateral aspect of his right knee. On aspiration, it was originally attempted to no avail. There was a long-standing history of this including two different MRIs, one about a year ago and one very recently both of which did not delineate the mass present. During aspiration previously, the patient had experienced neuritic type symptoms down his calf, which have mostly resolved by the time that this had occurred. The patient continued to complain of pain and dysfunction to his calf. This was discussed with him at length. He wished this to be explored and the mass excised even though knowing the possibility that they would not change his pain pattern with the potential of reoccurrence as well as the potential of scar stiffness, swelling, and peroneal nerve palsy. With this, he decided to proceed.,Upon observation preoperatively, the patient was noted to have a hard mass present to the posterolateral aspect of the right knee. It was noted to be tender. It was marked preoperatively prior to an anesthetic. Upon dissection, the patient was noted to have significant thickening of the posterior capsule. The posterolateral aspect of the knee above the posterolateral complex at the gastroc attachment to the lateral femoral condyle. There was also noted to be prominence of the lateral femoral condyle ridge. The bifurcation at the tibial and peroneal nerves were identified and no neuroma was present.,OPERATIVE PROCEDURE: ,The patient was laid supine upon the operating table. After receiving IV sedation, he was placed prone. Thigh tourniquet was placed. He was prepped and draped in the usual sterile manner. A transverse incision was carried down across the crease with a mass had been palpated through skin and subcutaneous tissue after exsanguination of the limb and tourniquet utilized. The nerve was identified and carefully retracted throughout the case. Both nerves were identified and carefully retracted throughout the case. There was noted to be no neuroma present. This was taken down until the gastroc was split. There was gross thickening of the joint capsule and after arthrotomy, a section of the capsule was excised. The lateral femoral condyle was then osteophied. We then smoothed off with a rongeur. After this, we could not palpate any mass whatsoever placing pressure upon the area of the nerve. Tourniquet was deflated. It was checked again. There was no excessive swelling. Swanson drain was placed to the depth of the wound and interrupted #2-0 Vicryl was utilized for subcutaneous fat closure and #4-0 nylon was utilized for skin closure. Adaptic, 4x4s, ABDs, and Webril were placed for compression dressing. Digits were warm _______ pulses distally at the end of the case. The tourniquet as stated has been deflated prior to closure and hemostasis was controlled. Expected surgical prognosis on this patient is guarded. | surgery, soft tissue mass, osteophyte, lateral femoral condyle, excision, capsular mass, arthrotomy, ostectomy, knee, soft tissue, femoral condyle, mass, subcutaneous, capsular, tourniquet, femoral, condyle, |
1,208 | Partial rotator cuff tear, left shoulder. Arthroscopy of the left shoulder with arthroscopic rotator cuff debridement, soft tissue decompression of the subacromial space of the left shoulder. | Surgery | Arthroscopy - Shoulder | PREOPERATIVE DIAGNOSIS: , Partial rotator cuff tear, left shoulder.,POSTOPERATIVE DIAGNOSIS: , Partial rotator cuff tear, left shoulder.,PROCEDURE PERFORMED:, Arthroscopy of the left shoulder with arthroscopic rotator cuff debridement, soft tissue decompression of the subacromial space of the left shoulder.,ANESTHESIA: ,Scalene block with general anesthesia.,ESTIMATED BLOOD LOSS: , 30 cc.,COMPLICATIONS: , None.,DISPOSITION: ,The patient went to the PACU stable.,GROSS OPERATIVE FINDINGS: , There was no overt pathology of the biceps tendon. There was some softening and loss of the articular cartilage over the glenoid. The labrum was ________ attached permanently to the glenoid. The biceps tendon was nonsubluxable. Upon ranging of the shoulder in internal and external rotation showed no evidence of rotator cuff tear on the articular side. Subacromial space did show excessive soft tissue causing some overstuffing of the subacromial space. There was reconstitution of the bursa noted as well.,HISTORY OF PRESENT ILLNESS:, This is a 51-year-old female had left shoulder pain of chronic nature who has had undergone prior rotator cuff debridement in May with partial pain relief and has had continued pain in the left shoulder. MRI shows partial rotator cuff tear.,PROCEDURE: , The patient was taken to the operating room and placed in a beachchair position. After all bony prominences were adequately padded, the head was placed in the headholder with no excessive extension in the neck on flexion. The left extremity was prepped and draped in usual fashion. The #18 gauge needles were inserted into the left shoulder to locate the AC joint, the lateral aspect of the acromion as well as the pass of the first trocar to enter the shoulder joint from the posterior aspect. We took an #11 blade scalpel and made a small 1-cm skin incision posteriorly approximately 4-cm inferior and medial to the lateral port of the acromion. A blunt trocar was used to bluntly cannulate the joint and we put the camera into the shoulder at that point of the joint and instilled sterile saline to distend the capsule and begin our arthroscopic assessment of the shoulder. A second port was established superior to the biceps tendon anteriorly under direct arthroscopic visualization using #11 blade on the skin and inserted bluntly the trocar and the cannula. The operative findings found intra-articularly were as described previously gross operative findings. We did not see any evidence of acute pathology. We then removed all the arthroscopic instruments as well as the trocars and tunneled subcutaneously into the subacromial space and reestablished the portal and camera and inflow with saline. The subacromial space was examined and found to have excessive soft tissue and bursa that was in the subacromial space that we debrided using arthroscopic shaver after establishing a lateral portal. All this was done and hemostasis was achieved. The rotator cuff was examined from the bursal side and showed no evidence of tears. There was some fraying out laterally near its attachment over the greater tuberosity, which was debrided with the arthroscopic shaver. We removed all of our instruments and suctioned the subacromial space dry. A #4-0 nylon was used on the three arthroscopic portal and on the skin we placed sterile dressing and the arm was placed in an arm sling. She was placed back on the gurney, extubated and taken to the PACU in stable condition. | surgery, subacromial space, arthroscopic, biceps tendon, labrum, glenoid, cartilage, partial rotator cuff tear, rotator cuff tear, shoulder arthroscopy, rotator cuff, arthroscopy, shoulder, tissue, subacromial, rotator, cuff, |
1,209 | Diagnostic arthroscopy with partial chondroplasty of patella, lateral retinacular release, and open tibial tubercle transfer with fixation of two 4.5 mm cannulated screws. Grade-IV chondromalacia patella and patellofemoral malalignment syndrome. | Surgery | Arthroscopy & Chondroplasty | PREOPERATIVE DIAGNOSES:,1. Chondromalacia patella.,2. Patellofemoral malalignment syndrome.,POSTOPERATIVE DIAGNOSES:,1. Grade-IV chondromalacia patella.,2. Patellofemoral malalignment syndrome.,PROCEDURE PERFORMED:,1. Diagnostic arthroscopy with partial chondroplasty of patella.,2. Lateral retinacular release.,3. Open tibial tubercle transfer with fixation of two 4.5 mm cannulated screws.,ANESTHESIA:, General.,COMPLICATIONS: , None.,TOURNIQUET TIME: , Approximately 70 minutes at 325 mmHg.,INTRAOPERATIVE FINDINGS: , Grade-IV chondromalacia noted to the central and lateral facet of the patella. There was a grade II to III chondral changes to the patellar groove. The patella was noted to be displaced laterally riding on the edge of the lateral femoral condyle. The medial lateral meniscus showed small amounts of degeneration, but no frank tears were seen. The articular surfaces and the remainder of the knee appeared intact. Cruciate ligaments also appeared intact to direct stress testing.,HISTORY: ,This is a 36-year-old Caucasian female with a long-standing history of right knee pain. She has been diagnosed in the past with chondromalacia patella. She has failed conservative therapy. It was discussed with her the possibility of a arthroscopy lateral release and a tubercle transfer (anterior medialization of the tibial tubercle) to release stress from her femoral patellofemoral joint. She elected to proceed with the surgical intervention. All risks and benefits of the surgery were discussed with her. She was in agreement with the treatment plan.,PROCEDURE: , On 09/04/03, she was taken to Operating Room at ABCD General Hospital. She was placed supine on the operating table with the general anesthesia administered by the Anesthesia Department. Her leg was placed in a Johnson knee holder and sterilely prepped and draped in the usual fashion. A stab incision was made in inferolateral and parapatellar regions. Through this the cannula was placed and the knee was inflated with saline solution. Intraoperative pictures were obtained. The above findings were noted. Second portal site was initiated in the inferomedial parapatellar region. Through this, a arthroscopic shaver was placed and the chondroplasty in the patella was performed and removed the loose articular debris. Next, the camera was placed through the inferomedial portal. An arthroscopic Bovie was placed through the inferolateral portal. A release of lateral retinaculum was then performed using the Bovie. Hemostasis was controlled with electrocautery. Next, the knee was suctioned dry. An Esmarch was used to exsanguinate the lower extremity. Tourniquet was inflated to 325 mmHg. An oblique incision was made along the medial parapatellar region of the knee. The subcuticular tissues were carefully dissected and the hemostasis was again controlled with electrocautery. The retinaculum was then incised in line with the incision. The patellar tendon was identified. The lateral and medial border of the tibial tubercle were cleared of all soft tissue debris. Next, an osteotome was then used to cut the tibial tubercle to 45 degree angle leaving the base of the bone incision intact. The tubercle was then pushed anteriorly and medially decreasing her Q-angle and anteriorizing the tibial tubercle. It was then held in place with a Steinmann pin. Following this, a two 4.5 mm cannulated screws, partially threaded, were drilled in place using standard technique to help fixate the tibial tubercle. There was excellent fixation noted. The Q-angle was noted to be decreased to approximately 15 degrees. She was transferred approximately 1 cm in length. The wound was copiously irrigated and suctioned dry. The medial retinaculum was then plicated causing further medialization of the patella. The retinaculum was reapproximated using #0 Vicryl. Subcuticular tissue were reapproximated with #2-0 Vicryl. Skin was closed with #4-0 Vicryl running PDS suture. Sterile dressing was applied to the lower extremities. She was placed in a Donjoy knee immobilizer locked in extension. It was noted that the lower extremity was warm and pink with good capillary refill following deflation of the tourniquet. She was transferred to recovery room in apparent stable and satisfactory condition.,Prognosis of this patient is poor secondary to the advanced degenerative changes to the patellofemoral joint. She will remain in the immobilizer approximately six weeks allowing the tubercle to reapproximate itself to the proximal tibia. | surgery, diagnostic arthroscopy, patellofemoral malalignment syndrome, cannulated, partial chondroplasty, retinacular, chondromalacia patella, tibial tubercle, patella, tubercle, arthroscopy, tourniquet, chondroplasty, chondromalacia, patellofemoral, |
1,210 | Rotator cuff tear, right shoulder. Superior labrum anterior and posterior lesion (peel-back), right shoulder. Arthroscopy with arthroscopic SLAP lesion. Repair of soft tissue subacromial decompression rotator cuff repair, right shoulder. | Surgery | Arthroscopic SLAP lesion | PREOPERATIVE DIAGNOSIS: , Rotator cuff tear, right shoulder.,POSTOPERATIVE DIAGNOSIS: , Superior labrum anterior and posterior lesion (peel-back), right shoulder.,PROCEDURE PERFORMED:,1. Arthroscopy with arthroscopic SLAP lesion.,2. Repair of soft tissue subacromial decompression rotator cuff repair, right shoulder.,SPECIFICATIONS: , The entire operative procedure was done in Inpatient Operating Suite, room #1 at ABCD General Hospital. This was done under a interscalene block anesthetic and subsequent general anesthetic in the modified beachchair position.,HISTORY AND GROSS FINDINGS: ,This is a 54-year-old white female suffering an increasing right shoulder pain for a few months prior to surgical intervention. She had an injury to her right shoulder when she fell off a bike. She was diagnosed preoperatively with a rotated cuff tear.,Intra-articularly besides we noted a large SLAP lesion, superior and posterior to the attachment of the glenoid labrum from approximately 12:30 back to 10:30. This acted as a peel-back type of mechanism and was displaced into the joint beyond the superior rim of the glenoid. This was an obvious avulsion into subchondral bone with bone exposed. The anterior aspect had degenerative changes, but did not have evidence of avulsion. The subscapular was noted to be intact. On the joint side of the supraspinatus, there was noted to be a laminated type of tearing to the rotated cuff to the anterior and mid-aspect of the supraspinatus attachment.,This was confirmed subacromially. The patient had a type-I plus acromion in outlet view and thus it was elected to not perform a subacromial decompression, but soft tissue release of the CA ligament in a releasing resection type fashion.,OPERATIVE PROCEDURE: , The patient was placed supine upon the operative table after she was given interscalene and then general anesthesia by the Anesthesia Department. She was safely placed in a modified beachchair position. She was prepped and draped in the usual sterile manner. The portals were created from outside the ends, posterior to the scope and anteriorly for an intraoperative portal and then laterally. She had at least two other portals appropriate for both repair mechanisms described above.,Attention was then turned to the SLAP lesion. The edges were debrided both on the bony side as well as soft tissue side. We used the anterior portal to lift up the mechanism and created a superolateral portal through the rotator cuff and into the edge of the labrum. Further debridement was carried out here. A drill hole was made just on the articular surface superiorly for a knotless anchor. A pull-through suture of #2 fiber wire was utilized with the ________. This was pulled through. It was tied to the leader suture of the knotless anchor. This was pulled through and one limb of the anchor loop was grabbed and the anchor impacted with a mallet. There was excellent fixation of the superior labrum. It was noted to be solid and intact. The anchor was placed safely in the bone. There was no room for further knotless or other anchors. After probing was carried out, hard copy Polaroid was obtained.,Attention was then turned to the articular side for the rotator cuff. It was debrided. Subchondral debridement was carried out to the tuberosity also. Care was taken to go to the subchondral region but not beyond. The bone was satisfactory.,Scope was then placed in the subacromial region. Gross bursectomy was carried out with in the lateral portal. This was done throughout as well as in the gutters anterolaterally and posteriorly. Debridement was carried out further to the rotator cuff. Two types of fixation were carried out, one with a superolateral portal a drill hole was made and anchor of the _knotless suture placed after PDS leader suture placed with a Caspari punch. There was an excellent reduction of the tear posteriorly and then anteriorly. Tendon to tendon repair was accomplished by placing a fiber wire across the tendon and tying sutured down through the anterolateral portal. This was done with a sliding stitch and then two half stitches. There was excellent reduction of the tear.,Attention was then turned to the CA ligament. It was released along with periosteum and the undersurface of the anterior acromion. The CA ligament was not only released but resected. There was noted to be no evidence of significant spurring with only a mostly type-I acromion. Thus, it was not elected to perform subacromial decompression for bone with soft tissue only. A pain buster catheter was placed separately. It was cut to length. An interrupted #4-0 nylon was utilized for portal closure. A 0.5% Marcaine was instilled subacromially. Adaptic, 4x4s, ABDs, and Elastoplast tape placed for dressing. The patient's arm was placed in a arm sling. She was transferred to PACU in apparent satisfactory condition. Expected surgical prognosis on this patient is fair. | surgery, rotator cuff tear, shoulder, labrum, lesion, decompression, subacromial, arthroscopic slap lesion, slap lesion, rotator cuff, anterior, arthroscopy, arthroscopic, slap, cuff |
1,211 | Arthroscopic rotator cuff repair, arthroscopic subacromial decompression, and arthroscopic extensive debridement, superior labrum anterior and posterior tear. | Surgery | Arthroscopic Rotator Cuff Repair - 2 | PROCEDURES,1. Arthroscopic rotator cuff repair.,2. Arthroscopic subacromial decompression.,3. Arthroscopic extensive debridement, superior labrum anterior and posterior tear.,PROCEDURE IN DETAIL: , After written consent was obtained from the patient, the patient was brought back into the operating room and identified. The patient was placed on the operating room table in supine position and given general anesthetic. Once the patient was under general anesthetic, a careful examination of the shoulder was performed. It revealed no patholigamentous laxity. The patient was then carefully positioned into a beach-chair position. We maintained the natural alignment of the head, neck, and thorax at all times. The shoulder and upper extremity was then prepped and draped in the usual sterile fashion.,Once we fully prepped and draped, we then began the surgery. We injected the glenohumeral joint with sterile saline with a spinal needle. This consisted of 60 cc of fluid. We then made a posterior incision for our portal, 2 cm inferior and 2 cm medial to the posterolateral angle of the acromion. Through this incision, a blunt trocar and cannula were placed in the glenohumeral joint. Through the cannula, a camera was placed; and the shoulder was insufflated with sterile saline through a preoperative feed. We then carefully examined the glenohumeral joint.,We found the articular surface to be in good condition. There was a superior labral tear (SLAP). This was extensively debrided using a shaver through an anterior portal. We also found a full thickness rotator cuff tear. We then drained the glenohumeral joint. We redirected our camera into the subacromial space. An anterolateral portal was made, both superior and inferior.,We then proceeded to perform a subacromial decompression using high-speed shaver. The bursa was extensively debrided. We then abraded the bone over the footprint of where the rotator cuff is usually attached. The corkscrew anchors were used to perform a rotator cuff repair. Pictures were taken.,Through a separate incision, an indwelling pain catheter was then placed. It was carefully positioned. Pictures were taken. We then drained the joint. All instruments were removed. The patient did receive IV antibiotic preoperatively. All portals were closed using 4-0 nylon sutures.,Xeroform, 4 x 4s, and OpSite were applied over the pain pump. ABD, tape, and a sling were also applied. A Cryo/Cuff was also placed over the shoulder. The patient was taken out of the beach-chair position maintaining the neutral alignment of the head, neck, and thorax. The patient was extubated and brought to the recovery room in stable condition. I then went out and spoke with the family, going over the case, postoperative instructions, and followup care. | surgery, debridement, superior labrum, patholigamentous, laxity, arthroscopic rotator cuff repair, subacromial decompression, glenohumeral joint, rotator cuff, arthroscopic, decompression, repair, glenohumeral, subacromial, rotator, cuff, |
1,212 | Arthroscopy of the arthroscopic glenoid labrum, rotator cuff debridement shaving glenoid and humeral head, and biceps tenotomy, right shoulder. Massive rotator cuff tear, right shoulder, near complete biceps tendon tear of right shoulder, chondromalacia of glenohumeral joint or right shoulder, and glenoid labrum tear of right shoulder. | Surgery | Arthroscopy - Glenoid Labrum | PREOPERATIVE DIAGNOSIS:, Rotator cuff tear, right shoulder.,POSTOPERATIVE DIAGNOSES:,1. Massive rotator cuff tear, right shoulder.,2. Near complete biceps tendon tear, right shoulder.,3. Chondromalacia of glenohumeral joint, right shoulder.,4. Glenoid labrum tear, right shoulder.,PROCEDURE PERFORMED: ,1. Arthroscopy of the arthroscopic glenoid labrum.,2. Rotator cuff debridement shaving glenoid and humeral head.,3. Biceps tenotomy, right shoulder.,SPECIFICATION: , The entire operative procedure was done in Inpatient Operating Suite, room #1 at ABCD General Hospital. This was done under interscalene block anesthetic in the modified beachchair position.,HISTORY AND GROSS FINDINGS: , This is a 61-year-old white male who is dominantly right-handed. He had increasing right shoulder pain and dysfunction for a number of years prior to surgical intervention. This was gradually done over a period of time. No specific accident or injury could be seen or pointed. He was refractory to conservative outpatient therapy. After discussing alternatives of the care as well as the advantages, disadvantages, risks, complications, and expectations, he elected to undergo the above-stated procedure on this date.,Preoperatively, the patient did not have limitation of motion. He had gross weakness to his supraspinatus, mildly to the infraspinatus and subscapularis upon strength testing prior to his anesthetic.,Intraarticularly, the patient had an 80% biceps tendon tear that was dislocated. His rotator interval was resolved as well as his subscapularis with tearing. The supraspinatus was completely torn, retracted back beyond the level of the labrum and approximately one-third or so of the infraspinatus was involved with the remaining portion being greatly thinned as far as we could observe. Glenoid labrum had degenerative tear in the inferior surface. Gross chondromalacia was present to approximately 50% of the humeral head and approximately the upper 40% of the glenoid surface.,OPERATIVE PROCEDURE: , The patient was laid supine upon the operative table. After receiving interscalene block anesthetic by the Anesthesia Department, he was safely placed in a modified beachchair position. He was prepped and draped in the usual sterile manner. The portals were created outside the end posteriorly and then anteriorly. A full and complete diagnostic arthroscopy was carried out with the above-noted findings. The shaver was placed anteriorly. Debridement was carried out to the glenoid labrum tear and the last 20% of the biceps tendon tear was completed. Debridement was carried out to the end or attachment of the bicep itself.,Debridement was carried out to what could be seen of the remaining rotator cuff there, but then the scope was redirected in a subacromial direction and gross bursectomy carried out. Debridement was then carried out to the rotator cuff remaining tendon near the tuberosity. No osteophytes were present. Because of the massive nature of the tear, the CA ligament was maintained and there were no substantial changes to the subacromial region to necessitate burring. There was concern because of instability that could be present at the end of this.,Another portal was created laterally to do all of this. We did what we could to mobilize all sections of the rotator cuff, superiorly, posteriorly, and anteriorly. We took this back to the level of coracoid base. We released the coracohumeral ligament basically all but there was no excursion basically all to the portion of the rotator cuff torn. Because of this, further debridement was carried out. Debridement had been previously carried out to the humeral head as well as glenoid surface to debride the chondromalacia and take this down to the smooth edge. Care was taken to not to debride deeper than that. This was done prior to the above.,All instrumentation was removed. A Pain-Buster catheter was placed into a separate anterolateral portal cut to length. Interrupted #4-0 nylon was utilized for portal closures. Adaptic, 4x4s, ABDs, Elastoplast tape were placed for a compression dressing.,The patient's arm was placed in an arm sling. He was transferred to his cart and to the PACU in apparent satisfactory condition. Expected surgical prognosis on this patient is quite guarded because of the above-noted pathology. | surgery, modified beachchair position, rotator cuff tear, glenoid labrum tear, glenohumeral joint, interscalene block, glenoid labrum, rotator cuff, rotator, debridement, glenoid, shoulder, tear, arthroscopy, arthroscopic, tenotomy, glenohumeral, supraspinatus, infraspinatus, subscapularis, chondromalacia, biceps, labrum, cuff, |
1,213 | Arthroscopy with arthroscopic subacromial decompression of the left shoulder. Impingement syndrome, left shoulder. Rule out superior labrum anterior and posterior lesion, left shoulder. | Surgery | Arthroscopic Subacromial Decompression - Shoulder | PREOPERATIVE DIAGNOSES:,1. Impingement syndrome, left shoulder.,2. Rule out superior labrum anterior and posterior lesion, left shoulder.,POSTOPERATIVE DIAGNOSES:, Impingement syndrome, left shoulder.,PROCEDURE PERFORMED:, Arthroscopy with arthroscopic subacromial decompression of the left shoulder.,ANESTHESIA: , The procedure was done under an interscalene block and subsequent general anesthetic in the modified beachchair position.,SPECIFICATIONS: , The entire operative procedure was done in Inpatient Operating Suite, room #1 at ABCD General Hospital.,HISTORY AND GROSS FINDINGS: , This is a 30-year-old white female suffering increasing left shoulder pain for a number of months prior to surgical intervention. She was completely refractory to conservative outpatient therapy. She had subacromial injection, which relieved the majority of her pain. She also had medial bordered scapular pain unrelated directly to the present problem. She had plus minus SLAP lesion testing preoperatively.,Operative findings in the joint included labrum was intact, long head of the biceps intact, laxity of 1+ all around, but clinically intact and without laxity. Subacromially, type-II plus acromion and no evidence of significant rotator cuff tear with scuffing only.,She also had evidence of calcium deposition in the CA ligament and undersurface of the AC joint.,OPERATIVE PROCEDURE: , The patient was laid supine upon the operative table. After receiving interscalene block general anesthetic by Anesthesia Department, she was placed in modified beachchair position. She was prepped and draped in the usual sterile manner. Portals were created outside the end, anterior and posterior, posterior and anterior, and subsequently laterally. A full and complete diagnostic arthroscopy was carried out in the intraarticular aspect of the joint with the above noted findings.,Attention was then turned to the subacromial region. The scope was placed. A lateral portal was created. Gross bursectomy was carried out. This was done with a 4.2 meniscal shaver as well as a hot Bovie. Calcium deposition mentioned was removed. With the rotator cuff intact, the periosteum was burned off the undersurface of the acromion and the CA ligament released anteriorly. A subacromial decompression sequentially from laterally to medially was then carried out. There was an excellent decompression. Debridement was carried out to the bursa. The portals were ultimately closed with #4-0 after Pain Buster catheter had been placed. Subacromial region was flooded with 0.5% Marcaine at approximately 15 cc or so. Adaptic, 4x4s, ABDs, and Elastoplast tape placed for dressing. The patient was awoken and transferred to PACU in apparent satisfactory condition. Expected surgical prognosis on this patient is fair. | surgery, impingement syndrome, shoulder, arthroscopic subacromial decompression, beachchair position, subacromial region, arthroscopic, interscalene, arthroscopy, impingement, labrum, acromion, portals, decompression, subacromial, |
1,214 | Right shoulder arthroscopy, subacromial decompression, distal clavicle excision, bursectomy, and coracoacromial ligament resection, carpal tunnel release, left knee arthroscopy, and partial medial and lateral meniscectomy. | Surgery | Arthroscopy Shoulder/Knee | PREOPERATIVE DIAGNOSES:,1. Medial meniscal tear, posterior horn of left knee.,2. Carpal tunnel syndrome chronic right hand with intractable pain, numbness, and tingling.,3. Impingement syndrome, right shoulder with acromioclavicular arthritis, bursitis, and chronic tendonitis.,POSTOPERATIVE DIAGNOSES:,1. Carpal tunnel syndrome, right hand, severe.,2. Bursitis, tendonitis, impingement, and AC arthritis, right shoulder.,3. Medial and lateral meniscal tears, posterior horn old, left knee.,PROCEDURE:,1. Right shoulder arthroscopy, subacromial decompression, distal clavicle excision, bursectomy, and coracoacromial ligament resection.,2. Right carpal tunnel release.,3. Left knee arthroscopy and partial medial and lateral meniscectomy.,ANESTHESIA: , General with regional.,COMPLICATIONS: ,None.,DISPOSITION: , To recovery room in awake, alert, and in stable condition.,OPERATIVE INDICATIONS: , A very active 50-year-old gentleman who had the above problems and workup revealed the above problems. He failed nonoperative management. We discussed the risks, benefits, and possible complications of operative and continued nonoperative management, and he gave his fully informed consent to the following procedure.,OPERATIVE REPORT IN DETAIL: , The patient was brought to the operating room and placed in the supine position on the operating room table. After adequate induction of general anesthesia, he was placed in the left lateral decubitus position. All bony prominences were padded. The right shoulder was prepped and draped in the usual sterile manner using standard Betadine prep, entered through three standard arthroscopic portals anterolateral and posterior incising the skin with a knife using sharp and blunt trocar.,Serial examination of the intraarticular portion of the shoulder showed all the structures to be normal including the biceps tendon ligaments, articular surfaces, and labrum. Subacromial space was entered. Visualization was poor due to the hemorrhagic bursitis, and this was resected back. It was essentially a type-3 acromion, which was converted to a type 1 by aiming the burr anterior from the posterior portal excising the larger anterior spur. Rotator cuff was little bit fray, but otherwise intact. Thus, the deep deltoid bursa and the markedly thickened coracoacromial ligament were removed. The burr was then introduced to the anterior portal and the distal clavicle excision carried out. The width of burr about 6 mm being careful to preserve the ligaments in the capsule, but removing the spurs and the denuded arthritic joint.,The patient tolerated the procedure very well. The shoulder was then copiously irrigated, drained free of any residual debris. The wound was closed with 3-0 Prolene. Sterile compressive dressing applied.,The patient was then placed on his back in the supine position and the right upper extremity and the left lower extremity were prepped and draped in usual sterile manner using a standard Betadine prep.,The attention was first turned to the right hand where it was elevated, exsanguinated using an Esmarch bandage, and the tourniquet was inflated to 250 mmHg for about 25 minutes. Volar approach to the carpal ligament was performed incising the skin with a knife and using cautery for hemostasis. Tenotomy and forceps dissection carried out through the superficial palmar fascia, carried down to the volar carpal ligament, which was then transected sharply with a knife and carried proximal and distal under direct vision using the scissors being careful to avoid the neurovascular structures.,Cautery was used for hemostasis. The never had an hourglass appearance where it was a kind of constricted as a result of the compression from the ligament, and so a small amount of Celestone was dripped onto the nerve to help quite it down. The patient tolerated this portion of the procedure very well. The hand was then irrigated, closed with Monocryl and Prolene, and sterile compressive dressing was applied and the tourniquet deflated.,Attention was then turned to the left knee where it was entered through inferomedial and inferolateral portals incising the skin with a knife and using sharp and blunt trocars. After entering the knee through inferomedial and inferolateral standard arthroscopic portals, examination of the knee showed a displaced bucket-handle tear in the medial meniscus and a radial tear at the lateral meniscus. These were resected back to the stable surface using a basket forceps and full-radius shaver. There was no evidence of any other significant arthritis in the knee. There was a lot of synovitis, and so after the knee was irrigated out and free of any residual debris, the knee was injected with Celestone and Marcaine with epinephrine.,The patient tolerated the procedure very well, and the wounds were closed with 3-0 Prolene and sterile compressive dressing was applied, and then the patient was taken to the recovery room, extubated, awake, alert, and in stable condition. | |
1,215 | Primary right shoulder arthroscopic rotator cuff repair with subacromial decompression. | Surgery | Arthroscopic Rotator Cuff Repair | PROCEDURE: , Primary right shoulder arthroscopic rotator cuff repair with subacromial decompression.,PATIENT PROFILE:, This is a 42-year-old female. Refer to note in patient chart for documentation of history and physical. Due to the nature of the patient's increasing pain, surgery is recommended. The alternatives, risks and benefits of surgery were discussed with the patient. The patient verbalized understanding of the risks as well as the alternatives to surgery. The patient wished to proceed with operative intervention. A signed and witnessed informed consent was placed on the chart. Prior to initiation of the procedure, patient identification and proposed procedure were verified by the surgeon in the pre-op area, and the operative site was marked by the patient and verified by the surgeon.,PRE-OP DIAGNOSIS: , Acute complete tear of the supraspinatus, Shoulder impingement syndrome.,POST-OP DIAGNOSIS:, Acute complete tear of the supraspinatus, Shoulder impingement syndrome.,ANESTHESIA: , General - Endotracheal.,FINDINGS:,ACROMION:,1. There was a medium-sized (5 - 10 mm) anterior acromial spur.,2. The subacromial bursa was inflamed.,3. The subacromial bursa was thickened.,4. There was thickening of the coracoacromial ligament.,LIGAMENTS / CAPSULE: , Joint capsule within normal limits.,LABRUM: , The labrum is within normal limits.,ROTATOR CUFF: , Full thickness tear of the supraspinatus tendon, 5 mm anterior to posterior, by 10 mm medial to lateral. Muscles and Tendons: The biceps tendon is within normal limits.,JOINT:, Normal appearance of the glenoid and humeral surfaces.,DESCRIPTION OF PROCEDURE:,PATIENT POSITIONING: , Following induction of anesthesia, the patient was placed in the beach-chair position on the standard operating table. All body parts were well padded and protected to make sure there were no pressure points. Subsequently, the surgical area was prepped and draped in the appropriate sterile fashion with Betadine.,INCISION TYPE:,1. Scope Ports: Anterior Portal.,2. Scope Ports: Posterior Portal.,3. Scope Ports: Accessory Anterior Portal.,INSTRUMENTS AND METHODS:,1. The arthroscope and instruments were introduced into the shoulder joint through the arthroscopic portals.,2. The subacromial space and bursa, biceps tendon, coracoacromial and glenohumeral ligaments, biceps tendon, rotator cuff, supraspinatus, subscapularis, infraspinatus, teres minor, capsulo-labral complex, capsule, glenoid labrum, humeral head, and glenoid, including the inner and outer surfaces of the rotator cuff, were visualized and probed.,3. The subacromial bursa, subacromial soft tissues and frayed rotator cuff tissue were resected and debrided using a motorized resector and 4.5 Synovial Resector.,4. The anterior portion of the acromion and acromial spur were resected with the 5.5 acromionizer burr. Approximately 5 mm of bone was removed. The coracoacromial ligament was released with the bony resection. The shoulder joint was thoroughly irrigated.,5. The edges of the cuff tissue were prepared, prior to the fixation, using the motorized resector.,6. The supraspinatus tendon was reattached and sutured using the arthroscopic knot pusher and Mitek knotless anchor system and curved pointed suture passer and large bore cannula (to pass the sutures). The repair was accomplished in a side-to-side and a tendon-to-bone fashion using three double loaded Mitek G IV suture anchors with 1 PDS suture.,7. The repair was stable to palpation with the probe and watertight.,8. The arthroscope and instruments were removed from the shoulder.,PATHOLOGY SPECIMEN: , No pathology specimens.,WOUND CLOSURE:, The joint was thoroughly irrigated with 7 L of sterile saline. The portal sites were infiltrated with 1% Xylocaine. The skin was closed with 4-0 Vicryl using interrupted subcuticular technique.,DRAINS / DRESSING:, Applied sterile dressing including gauze, iodoform gauze and Elastoplast.,SPONGE / INSTRUMENT / NEEDLE COUNTS:, Final counts were correct. | null |
1,216 | Recurrent anterior dislocating left shoulder. Arthroscopic debridement of the left shoulder with attempted arthroscopic Bankart repair followed by open Bankart arthroplasty of the left shoulder. | Surgery | Arthroscopic Debridement - Shoulder | PREOPERATIVE DIAGNOSIS: , Recurrent anterior dislocating left shoulder.,POSTOPERATIVE DIAGNOSIS:, Recurrent anterior dislocating left shoulder.,PROCEDURE PERFORMED:, Arthroscopic debridement of the left shoulder with attempted arthroscopic Bankart repair followed by open Bankart arthroplasty of the left shoulder.,PROCEDURE: ,The patient was taken to OR #2, administered general anesthetic after ineffective interscalene block had been administered in the preop area. The patient was positioned in the modified beachchair position utilizing the Mayfield headrest. The left shoulder was propped posteriorly with a rolled towel. His head was secured to the Mayfield headrest. The left shoulder and upper extremity were then prepped and draped in the usual manner. A posterior lateral port was made for _____ the arthroscopic cannula. The scope was introduced into the glenohumeral joint. There was noted to be a complete tear of the anterior glenoid labrum off from superiorly at about 11:30 extending down inferiorly to about 6 o'clock. The labrum was adherent to the underlying capsule. The margin of the glenoid was frayed in this area. The biceps tendon was noted to be intact. The articular surface of the glenoid was fairly well preserved. The articular surface on the humeral head was intact; however, there was a large Hill-Sachs lesion on the posterolateral aspect of the humeral head. The rotator cuff was visualized and noted to be intact. The axillary pouch was visualized and it was free of injury. There were some cartilaginous fragments within the axillary pouch. Attention was first directed after making an anterior portal to fixation of the anterior glenoid labrum. Utilizing the Chirotech system through the anterior cannula, the labrum was secured with the pin and drill component and was then tacked back to the superior glenoid rim at about the 11 o'clock position. A second tack was then placed at about the 8 o'clock position. The labrum was then probed and was noted to be stable. With some general ranging of the shoulder, the tissue was pulled out from the tacks. An attempt was made at placement of two other tacks; however, the tissue was not of good quality to be held in position. Therefore, all tacks were either buried down to a flat surface or were removed from the anterior glenoid area. At this point, it was deemed that an open Bankart arthroplasty was necessary. The arthroscopic instruments were removed. An anterior incision was made extending from just lateral of the coracoid down toward the axillary fold. The skin incision was taken down through the skin. Subcutaneous tissues were then separated with the coag Bovie to provide hemostasis. The deltopectoral fascia was identified. It was split at the deltopectoral interval and the deltoid was reflected laterally. The subdeltoid bursa was then removed with rongeurs. The conjoint tendon was identified. The deltoid and conjoint tendons were then retracted with a self-retaining retractor. The subscapularis tendon was identified. It was separated about a centimeter from its insertion, leaving the tissue to do sew later. The subscapularis was reflected off superiorly and inferiorly and the muscle retracted medially. This allowed for visualization of the capsule. The capsule was split near the humeral head insertion leaving a tag for repair. It was then split longitudinally towards the glenoid at approximately 9 o'clock position. This provided visualization of the glenohumeral joint. The friable labral and capsular tissue was identified. The glenoid neck was already prepared for suturing, therefore, three Mitek suture anchors were then positioned to place at approximately 7 o'clock, 9 o'clock, and 10 o'clock. The sutures were passed through the labral capsular tissue and tied securely. At this point, the anterior glenoid rim had been recreated. The joint was then copiously irrigated with gentamicin solution and suctioned dry. The capsule was then repaired with interrupted #1 Vicryl suture and repaired back to its insertion site with #1 Vicryl suture. This later was then copiously irrigated with gentamicin solution and suctioned dry. Subscapularis was reapproximated on to the lesser tuberosity of the humerus utilizing interrupted #1 Vicryl suture. This later was then copiously irrigated as well and suctioned dry. The deltoid fascia was approximated with running #2-0 Vicryl suture. Subcutaneous tissues were approximated with interrupted #2-0 Vicryl and the skin was approximated with a running #4-0 subcuticular Vicryl followed by placement of Steri-Strips. 0.25% Marcaine was placed in the subcutaneous area for postoperative analgesia. The patient was then placed in a shoulder immobilizer after a bulky dressing had been applied. The patient was then transferred to the recovery room in apparent satisfactory condition. | surgery, dislocating, bankart, arthroplasty, bankart repair, arthroscopic debridement, anterior, arthroscopic, debridement, deltoid, glenoid, humeral, interrupted, shoulder, subscapularis |
1,217 | Arthroplasty of the right second digit. Hammertoe deformity of the right second digit. | Surgery | Arthroplasty - Hammertoe | PREOPERATIVE DIAGNOSIS:, Hammertoe deformity of the right second digit.,POSTOPERATIVE DIAGNOSIS: , Hammertoe deformity of the right second digit.,PROCEDURE PERFORMED: , Arthroplasty of the right second digit.,The patient is a 77-year-old Hispanic male who presents to ABCD Hospital for surgical correction of a painful second digit hammertoe. The patient has failed attempts at conservative treatment and is unable to wear shoes without pain to his second toe. The patient presents n.p.o. since mid night last night and consented to sign in the chart. H&P is complete.,PROCEDURE IN DETAIL:, After an IV was instituted by the Department of Anesthesia in the preoperative holding area, the patient was escorted to the operating room and placed on the table in the supine position. Using Webril, the distal leg and ankle was padded and a ankle pneumatic tourniquet was placed around the right ankle, but left deflated at this time. Restraining, a lap belt was then placed around the patient's abdomen while laying on the table. After adequate anesthesia was administered by the Department of Anesthesia, a local digital block using 5 cc of 0.5% Marcaine plain was used to provide local anesthesia. The foot was then prepped and draped in the normal sterile orthopedic manner. The foot was then elevated and Esmarch bandage was applied, after which time the tourniquet was inflated to 250 mmHg. The foot was then brought down to the level of the table and stockinet was cut and reflected after the Esmarch bandage was removed. A wet and dry sponge was then used to cleanse the operative site and using a skin skribe a dorsal incisional line was outlined extending from the proximal phalanx over the proximal interphalangeal joint on to the middle phalanx.,Then using a fresh #15 blade, a dorsolinear incision was made, partial thickness through the skin after testing anesthesia with one to two pickup. Then using a fresh #15 blade, incision was deepened and using medial to lateral pressure, the incision was opened into the subcutaneous tissue. Care was taken to reflect the subcutaneous tissue from the underlying deep fascia to mobilize the skin. This was performed with the combination of blunt and dull dissection. Care was taken to avoid proper digital arteries and neurovascular bundles as were identified. Attention was then directed to the proximal interphalangeal joint and after identifying the joint line, a transverse linear incision was made over the dorsal surface of the joint. The medial and lateral sides of the joint capsule were then also incised on the superior half in order to provide increased exposure. Following this, the proximal portion of the transected extensor digitorum longus tendon was identified using an Adson-Brown pickup. It was elevated with fresh #15 blade. The tendon and capsule was reflected along with the periosteum from the underlying bone dorsally. Following this, the distal portion of the tendon was identified in a like manner. The tendon and the capsule as well as the periosteal tissue was reflected from the dorsal surface of the bone. The proximal interphalangeal joint was then distracted and using careful technique, #15 blade was used to deepen the incision and while maintaining close proximity to the bone and condyles, the lateral and medial collateral ligaments were freed up from the side of the proximal phalanx head.,Following this, the head of the proximal phalanx was known to have adequate exposure and was freed from soft tissues. Then using a sagittal saw with a #139 blade, the head of he proximal phalanx was resected. Care was taken to avoid the deep flexor tendon. The head of the proximal phalanx was taken with the Adson-Brown and using a #15 blade, the plantar periosteal tissue was freed up and the head was removed and sent to pathology. The wound was then flushed using a sterile saline with gentamicin and the digit was noted to be in good alignment. The digit was also noted to be in rectus alignment. Proximal portion of the tendon was shortened to allow for removal of the redundant tendon after correction of the deformity. Then using a #3-0 Vicryl suture, three simple interrupted sutures were placed for closure of the tendon and capsular tissue. Then following this, #4-0 nylon was used in a combination of horizontal mattress and simple interrupted sutures to close the skin. The toe was noted to be in good alignment and then 1 cc of dexamethasone phosphate was injected into the incision site. Following this, the incision was dressed using a sterile Owen silk soaked in saline and gentamicin. The toe was bandaged using 4 x 4s, Kling, and Coban. The tourniquet was deflated and immediate hyperemia was noted to the digits I through V of the right foot.,The patient was then transferred to the cart and was escorted to the Postanesthesia Care Unit where the patient was given postoperative surgical shoe. Total tourniquet time for the case was 30 minutes. While in the recovery, the patient was given postoperative instructions to include, ice and elevation to his right foot. The patient was given pain medications of Tylenol #3, quantity 30 to be taken one to two tablets every six to eight hours as necessary for moderate to severe pain. The patient was also given prescription for cane to aid in ambulation. The patient will followup with Dr. X on Tuesday in his office for postoperative care. The patient was instructed to keep the dressings clean, dry, and intact and to not remove them before his initial office visit. The patient tolerated the procedure well and the anesthesia with no complications. | surgery, hammertoe deformity, arthroplasty, digit, proximal interphalangeal joint, periosteal tissue, interrupted sutures, interphalangeal joint, proximal phalanx, proximal, painful, tourniquet, hammertoe, phalanx, head, incisional, tendon |
1,218 | Hammertoe deformity, left fifth digit and ulceration of the left fifth digit plantolaterally. Arthroplasty of the left fifth digit proximal interphalangeal joint laterally and excision of plantar ulceration of the left fifth digit 3 cm x 1 cm in size. | Surgery | Arthroplasty | PREOPERATIVE DIAGNOSES:,1. Hammertoe deformity, left fifth digit.,2. Ulceration of the left fifth digit plantolaterally.,POSTOPERATIVE DIAGNOSIS:,1. Hammertoe deformity, left fifth toe.,2. Ulceration of the left fifth digit plantolaterally.,PROCEDURE PERFORMED:,1. Arthroplasty of the left fifth digit proximal interphalangeal joint laterally.,2. Excision of plantar ulceration of the left fifth digit 3 cm x 1 cm in size.,OPERATIVE PROCEDURE IN DETAIL: , The patient is a 38-year-old female with longstanding complaint of painful hammertoe deformity of her left fifth toe. The patient had developed ulceration plantarly after being scheduled for removal of a plantar mass in the same area. The patient elects for surgical removal of this ulceration and correction of her hammertoe deformity at this time.,After an IV was instituted by the Department of Anesthesia, the patient was escorted to the OR where the patient was placed on the Operating Room table in the supine position. After adequate amount of IV sedation was administered by Anesthesia Department, the patient was given a digital block to the left fifth toe using 0.5% Marcaine plain with 1% lidocaine plain in 1:1 mixture totaling 6 cc. Following this, the patient was draped and prepped in a normal sterile orthopedic manner. An ankle tourniquet was placed on the left ankle and the left foot was elevated and Esmarch bandage applied to exsanguinate the foot. The ankle tourniquet was then inflated to 230 mmHg and then was brought back down to the level of the table. The stockinette was then cut and reflected and held in place using towel clamp.,The skin was then cleansed using the wet and dry Ray-Tec sponge and then the plantar lesion was outlined. The lesion measured 1 cm in diameter at the level of the skin and a 3 cm elliptical incision line was drawn on the surface of the skin in the plantolateral aspect of the left fifth digit. Then using a fresh #15 blade, skin incision was made. Following this, the incision was then deepened using a fresh #15 blade down to the level of the subcutaneous tissue. Using a combination of sharp and blunt dissection, the skin was reflected distally and proximally to the lesion. The lesion appeared well encapsulated with fibrous tissue and through careful dissection using combination of sharp and drill instrumentation the ulceration was removed in its entirety. The next further exploration was performed to ensure that no residual elements of the fibrous capsular tissue remained within. The lesion extended from the level of the skin down to the periosteal tissue of the middle and distal phalanx, however, did not show any evidence of extending beyond the level of a periosteum. Remaining tissues were inspected and appeared healthy. The lesion was placed in the specimen container and sent to pathology for microanalysis as well as growth. Attention was then directed to the proximal interphalangeal joint of the left fifth digit and using further dissection with a #15 blade, the periosteum was reflected off the lateral aspect of the proximal ________ median phalanx. The capsule was also reflected to expose the prominent lateral osseous portion of this joint. Using a sagittal saw and #139 blade, the lateral osseous prominence was resected. This was removed in entirety. Then using power-oscillating rasp, the sharp edges were smoothed and recontoured to the desirable anatomic condition. Then the incision and wound was flushed using copious amounts of sterile saline with gentamycin. Following this, the bone was inspected and appeared to be healthy with no evidence of involvement from the removed aforementioned lesion.,Following this, using #4-0 nylon in a combination of horizontal mattress and simple interrupted sutures, the lesion wound was closed and skin was approximated well without tension to the surface skin. Following this, the incision site was dressed using Owen silk, 4x4s, Kling, and Coban in a normal fashion. The tourniquet was then deflated and hyperemia was noted to return to digits one through five of the left foot. The patient was then escorted from the operative table into the Postanesthesia Care Unit. The patient tolerated the procedure and anesthesia well and was brought to the Postanesthesia Care Unit with vital signs stable and vascular status intact. In the recovery, the patient was given a surgical shoe as well as given instructions for postoperative care to include rest ice and elevation as well as the patient was given prescription for Naprosyn 250 mg to be taken three times daily as well as Vicodin ES to be taken q.6h. as needed.,The patient will follow-up on Friday with Dr. X in office for further evaluation. The patient was also given instructions as to signs of infection and to monitor her operative site. The patient was instructed to keep daily dressings intact, clean, dry, and to not remove them. | surgery, hammertoe deformity, plantolaterall, ulceration, arthroplasty, plantar ulceration, interphalangeal, painful hammertoe, proximal interphalangeal joint, interphalangeal joint, digit, toe, blade, deformity, incision, hammertoe, lesion |
1,219 | Torn lateral meniscus and chondromalacia of the patella, right knee. Arthroscopic lateral meniscoplasty and patellar shaving of the right knee. | Surgery | Arthroscopic Meniscoplasty | PREOPERATIVE DIAGNOSES:,1. Torn lateral meniscus, right knee.,2. Chondromalacia of the patella, right knee.,POSTOPERATIVE DIAGNOSES:,1. Torn lateral meniscus, right knee.,2. Chondromalacia of the patella, right knee.,PROCEDURE PERFORMED:,1. Arthroscopic lateral meniscoplasty.,2. Patellar shaving of the right knee.,ANESTHESIA: ,General.,COMPLICATIONS: , None.,ESTIMATED BLOOD LOSS: , Minimal.,TOTAL TOURNIQUET TIME:, Zero.,GROSS FINDINGS: , A complex tear involving the lateral and posterior horns of the lateral meniscus and grade-II chondromalacia of the patella.,HISTORY OF PRESENT ILLNESS: , The patient is a 45-year-old Caucasian male presented to the office complaining of right knee pain. He complained of pain on the medial aspect of his right knee after an injury at work, which he twisted his right knee.,PROCEDURE: ,After all potential complications, risks, as well as anticipated benefits of the above-named procedures were discussed at length with the patient, informed consent was obtained. The operative extremity was then confirmed with the operative surgeon, the patient, the Department of Anesthesia and the nursing staff.,The patient was then transferred to preoperative area to Operative Suite #2, placed on the operating table in supine position. Department of Anesthesia administered general anesthetic to the patient. All bony prominences were well padded at this time. The right lower extremity was then properly positioned in a Johnson knee holder. At this time, 1% lidocaine with epinephrine 20 cc was administered to the right knee intra-articularly under sterile conditions. The right lower extremity was then sterilely prepped and draped in usual sterile fashion. Next, after all bony soft tissue landmarks were identified, an inferolateral working portal was established by making a 1-cm transverse incision at the level of the joint line lateral to the patellar tendon. The cannula and trocar were then inserted through this, putting the patellofemoral joint. An arthroscopic camera was then inserted and the knee was sequentially examined including the patellofemoral joint, the medial and lateral gutters, medial lateral joints, and the femoral notch. Upon viewing of the patellofemoral joint, there was noted to be grade-II chondromalacia changes of the patella. There were no loose bodies noted in the either gutter. Upon viewing of the medial compartment, there was no chondromalacia or meniscal tear was noted. While in this area, attention was directed to establish the inferomedial instrument portal. This was first done using a spinal needle for localization followed by 1-cm transverse incision at the joint line. A probe was then inserted through this portal and the meniscus was further probed. Again, there was noted to be no meniscal tear. The knee was taken through range of motion and there was no chondromalacia. Upon viewing of the femoral notch, there was noted to be intact ACL with negative drawer sign. PCL was also noted to be intact. Upon viewing of the lateral compartment, there was noted to be a large bucket-handle tear involving the lateral and posterior horns. It was reduced from the place, however, involved the white and red white area was elected to excise the bucket-handle. An arthroscopic scissor was then inserted and the two remaining attachments the posterior and lateral attachments were then clipped and a Schlesinger grasper was then used to remove the resected meniscus. It was noted that the meniscus was followed out to the whole and the entire piece was taken out of the knee. Pictures were taken both pre-meniscal resection and post-meniscal resection. The arthroscopic shaver was then inserted into the medial portal and the remaining meniscus was contoured. The lateral gutter was then examined and was noted to be no loose bodies and ______ was intact. Next, attention was directed to the inner surface of the patella. This was debrided using the 2.5 arthroscopic shaver. It was noted to be quite smooth and postprocedure the patient was taken ________ well. The knee was then copiously irrigated and suctioned dry and all instrumentation was removed. 20 cc of 0.25% Marcaine was then administered to each portal as well as intra-articularly.,Sterile dressing was then applied consisting of Adaptic, 4x4s, ABDs, and sterile Webril and a stockinette to the right lower extremity. At this time, Department of Anesthesia reversed the anesthetic. The patient was transferred back to the hospital gurney to the Postanesthesia Care Unit. The patient tolerated the procedure and there were no complications. | surgery, patella, chondromalacia, lateral meniscus, complex tear, torn lateral meniscus, femoral notch, meniscal tear, bucket handle, meniscal resection, arthroscopic shaver, patellofemoral joint, arthroscopic, knee, torn, meniscoplasty, meniscal, joint, meniscus, |
1,220 | Laparoscopic appendectomy. Acute appendicitis. | Surgery | Appendectomy Laparoscopic | PREOPERATIVE DIAGNOSIS: , Acute appendicitis.,POSTOPERATIVE DIAGNOSIS: , Acute appendicitis.,PROCEDURE: , Laparoscopic appendectomy.,ANESTHESIA: , General endotracheal.,INDICATIONS: , Patient is a pleasant 31-year-old gentleman who presented to the hospital with acute onset of right lower quadrant pain. History as well as signs and symptoms are consistent with acute appendicitis as was his CAT scan. I evaluated the patient in the emergency room and recommended that he undergo the above-named procedure. The procedure, purpose, risks, expected benefits, potential complications, alternative forms of therapy were discussed with him and he was agreeable with surgery.,FINDINGS: , Patient was found to have acute appendicitis with an inflamed appendix, which was edematous, but essentially no suppuration.,TECHNIQUE: ,The patient was identified and then taken into the operating room, where after induction of general endotracheal anesthesia, the abdomen was prepped with Betadine solution and draped in sterile fashion. An infraumbilical incision was made and carried down by blunt dissection to the level of the fascia, which was grasped with an Allis clamp and two stay sutures of 2-0 Vicryl were placed on either side of the midline. The fascia was tented and incised and the peritoneum entered by blunt finger dissection. A Hasson cannula was placed and a pneumoperitoneum to 15 mmHg pressure was obtained. Patient was placed in the Trendelenburg position, rotated to his left, whereupon under direct vision, the 12-mm midline as well as 5-mm midclavicular and anterior axillary ports were placed. The appendix was easily visualized, grasped with a Babcock's. A window was created in the mesoappendix between the appendix and the cecum and the Endo GIA was introduced and the appendix was amputated from the base of the cecum. The mesoappendix was divided using the Endo GIA with vascular staples. The appendix was placed within an Endo bag and delivered from the abdominal cavity. The intra-abdominal cavity was irrigated. Hemostasis was assured within the mesentery and at the base of the cecum. All ports were removed under direct vision and then wounds were irrigated with saline antibiotic solution. The infraumbilical defect was closed with a figure-of-eight 0 Vicryl suture. The remaining wounds were irrigated and then everything was closed subcuticular with 4-0 Vicryl suture and Steri-Strips. Patient tolerated the procedure well, dressings were applied, and he was taken to recovery room in stable condition. | surgery, endo gia, babcock's, laparoscopic appendectomy, direct vision, abdominal cavity, acute appendicitis, appendectomy, hemostasis, laparoscopic, infraumbilical, appendix, appendicitis, endotracheal, |
1,221 | Femoroacetabular impingement. Left hip arthroscopic debridement, femoral neck osteoplasty, and labral repair. | Surgery | Arthroscopic Debridement & Labral Repair - Hip | PREOPERATIVE DIAGNOSIS: , Femoroacetabular impingement.,POSTOPERATIVE DIAGNOSIS: , Femoroacetabular impingement.,OPERATIONS PERFORMED,1. Left hip arthroscopic debridement.,2. Left hip arthroscopic femoral neck osteoplasty.,3. Left hip arthroscopic labral repair.,ANESTHESIA: , General.,OPERATION IN DETAIL: , The patient was taken to the operating room, where he underwent general anesthetic. His bilateral lower extremities were placed under traction on the Hana table. His right leg was placed first. The traction post was left line, and the left leg was placed in traction. Sterile Hibiclens and alcohol prep and drape were then undertaken. A fluoroscopic localization was undertaken. Gentle traction was applied. Narrow arthrographic effect was obtained. Following this, the ProTrac portal was made under the fluoro visualization, and then, a direct anterolateral portal made and a femoral neck portal made under direct visualization. The diagnostic arthroscopy showed the articular surface to be intact with a moderate anterior lip articular cartilage delamination injury that propagated into the acetabulum. For this reason, the acetabular articular cartilage was taken down and stabilized. This necessitated takedown of the anterior lip of the acetabulum and subsequent acetabular osteoplasty debridement with associated labral repair. The labrum was repaired using absorbable Smith & Nephew anchors with a sliding SMC knot. After stabilization of the labrum and the acetabulum, the ligamentum teres was assessed and noted to be stable. The remnant articular surface of the femoral artery and acetabulum was stable. The posterior leg was stable. The traction was left half off, and the anterolateral aspect of the head and neck junction was identified. A stable femoral neck decompression was accomplished starting laterally and proceeding anteriorly. This terminated with the hip coming out of traction and indeterminable flexion. A combination of burs and shavers was utilized to perform a stable femoral neck osteoplasty decompression. The decompression was completed with thorough irrigation of the hip. The cannula was removed, and the portals were closed using interrupted nylon. The patient was placed into a sterile bandage and anesthetized intraarticularly with 10 mL of ropivacaine subcutaneously with 20 mL of ropivacaine and at this point was taken to the recovery room. He tolerated the procedure very well with no signs of complications. | surgery, labral repair, femoral neck osteoplasty, arthroscopic debridement, femoroacetabular impingement, arthroscopic, femoroacetabular, impingement, debridement, osteoplasty, acetabulum |
1,222 | Laparoscopic appendectomy. Acute suppurative appendicitis. A CAT scan of the abdomen and pelvis was obtained revealing findings consistent with acute appendicitis. There was no evidence of colitis on the CAT scan. | Surgery | Appendectomy Laparoscopic - 1 | PREOPERATIVE DIAGNOSIS: , Acute appendicitis.,POSTOPERATIVE DIAGNOSIS:, Acute suppurative appendicitis.,PROCEDURE PERFORMED: , Laparoscopic appendectomy.,ANESTHESIA: , General endotracheal and Marcaine 0.25% local.,INDICATIONS:, This 29-year-old female presents to ABCD General Hospital Emergency Department on 08/30/2003 with history of acute abdominal pain. On evaluation, it was noted that the patient has clinical findings consistent with acute appendicitis. However, the patient with additional history of loose stools for several days prior to event. Therefore, a CAT scan of the abdomen and pelvis was obtained revealing findings consistent with acute appendicitis. There was no evidence of colitis on the CAT scan. With this in mind and the patient's continued pain at present, the patient was explained the risks and benefits of appendectomy. She agreed to procedure and informed consent was obtained.,GROSS FINDINGS: , The appendix was removed without difficulty with laparoscopic approach. The appendix itself noted to have a significant inflammation about it. There was no evidence of perforation of the appendix.,PROCEDURE DETAILS:, The patient was placed in supine position. After appropriate anesthesia was obtained and sterile prep and drape completed, a #10 blade scalpel was used to make a curvilinear infraumbilical incision. Through this incision, a Veress needle was utilized to create a CO2 pneumoperitoneum of 15 mmHg. The Veress needle was then removed. A 10 mm trocar was then introduced through this incision into the abdomen. A video laparoscope was then inserted and the above noted gross findings were appreciated upon evaluation. Initially, bilateral ovarian cysts were appreciated, however, there was no evidence of acute disease on evaluation. Photodocumentation was obtained.,A 5 mm port was then placed in the right upper quadrant. This was done under direct visualization and a blunt grasper was utilized to mobilize the appendix. Next, a 12 mm port was placed in the left lower quadrant lateral to the rectus musculature under direct visualization. Through this port, the dissector was utilized to create a small window in the mesoappendix. Next, an EndoGIA with GI staples was utilized to fire across the base of the appendix, which was done noting it to be at the base of the appendix. Next, staples were changed to vascular staples and the mesoappendix was then cut and vessels were then ligated with vascular staples. Two 6 X-loupe wires with EndoGIA were utilized in this prior portion of the procedure. Next, an EndoCatch was placed through the 12 mm port and the appendix was placed within it. The appendix was then removed from the 12 mm port site and taken off the surgical site. The 12 mm port was then placed back into the abdomen and CO2 pneumoperitoneum was recreated. The base of the appendix was reevaluated and noted to be hemostatic. Aspiration of warm saline irrigant then done and noted to be clear. There was a small adhesion appreciated in the region of the surgical site. This was taken down with blunt dissection without difficulty. There was no evidence of other areas of disease. Upon re-exploration with a video laparoscope in the abdomen and after this noting the appendix base to be hemostatic and intact. The instruments were removed from the patient and the port sites were then taken off under direct visualization. The CO2 pneumoperitoneum was released into the air and the fascia was approximated in the 10 mm and 12 mm port sites with #0 Vicryl ligature x2. Marcaine 0.25% was then utilized in all three incision sites and #4-0 Vicryl suture was used to approximate the skin and all three incision sites. Steri-Strips and sterile dressings were applied. The patient tolerated the procedure well and taken to Postoperative Care Unit in stable condition and monitored under General Medical Floor on IV antibiotics, pain medications, and return to diet. | surgery, abdomen, pelvis, laparoscopic appendectomy, suppurative appendicitis, veress needle, acute appendicitis, appendix, appendectomy, pneumoperitoneum, laparoscopic, appendicitis |
1,223 | Bilateral Crawford subtalar arthrodesis with open Achilles Z-lengthening and bilateral long-leg cast. | Surgery | Arthrodesis | PREOPERATIVE DIAGNOSIS: , Congenital myotonic muscular dystrophy with bilateral planovalgus feet.,POSTOPERATIVE DIAGNOSIS: , Congenital myotonic muscular dystrophy with bilateral planovalgus feet.,PROCEDURE: , Bilateral Crawford subtalar arthrodesis with open Achilles Z-lengthening and bilateral long-leg cast.,ANESTHESIA: , Surgery performed under general anesthesia. The patient received 6 mL of 0.25% Marcaine local anesthetic on each side.,TOURNIQUET TIME: ,Tourniquet time was 53 minutes on the left and 45 minutes on the right.,COMPLICATIONS: , There were no intraoperative complications.,DRAINS:, None.,SPECIMENS: , None.,HARDWARE USED: , Staple 7/8 inch x1 on each side.,HISTORY AND PHYSICAL: ,The patient is a 5-year-4-month-old male who presents for evaluation of feet. He has been having significant feet pain with significant planovalgus deformity. The patient was noted to have flexible vertical talus. It was decided that the patient would benefit by subtalar arthrodesis, possible autograft, and Achilles lengthening. This was explained to the mother in detail. This is going to be a stabilizing measure and the patient will probably need additional surgery at a later day when his foot is more mature. Risks of surgery include risks of anesthesia, infection, bleeding, changes in sensation and motion of the extremity, hardware failure, need for other surgical procedures, need to be nonweightbearing for some time. All questions were answered and the mother agreed to the above plan.,PROCEDURE NOTE: , The patient was taken to the operating room, placed supine on the operating room, general anesthesia was administered. The patient received Ancef preoperatively. Bilateral nonsterile tourniquets were placed on each thigh. A bump was placed underneath the left buttock. Both the extremities were then prepped and draped in standard surgical fashion. Attention was first turned towards the left side. Intended incision was marked on the skin. The ankle was taken through a range of motion with noted improvement in the reduction of the talocalcaneal alignment with the foot in plantar flexion on the lateral view. The foot was wrapped in Esmarch prior to inflation of tourniquet to 200 mmHg. Incision was then made over the left lateral aspect of the hind foot to expose the talocalcaneal joint. The sinus tarsi was then identified using a U-shaped flap to tack muscles, and periosteum was retracted distally. Once the foot was reduced a Steinman pin was used to hold it in position. This position was first checked on the fluoroscopy. The 7/8th inch staple was then placed across the sinus tarsi to maintain the reduction. This was also checked with fluoroscopy. The incision was then extended posteriorly to allow for visualization of the Achilles, which was Z-lengthened with the release of the lateral distal half. This was sutured using 2-0 Ethibond and that was also oversewn. The wound was irrigated with normal saline. The periosteal flap was sutured over the staple using 2-0 Vicryl. Skin was closed using 2-0 Vicryl interrupted and then with 4-0 Monocryl. The area was injected with 6 mL of 0.25% Marcaine local anesthetic. The wound was cleaned and dried, dressed with Steri-Strips, Xeroform, and 4 x 4s and Webril. Tourniquet was released after 53 minutes. The exact same procedure was repeated on the right side with no changes or complications. Tourniquet time on the right side was 45 minutes. The patient tolerated the procedure well. Bilateral long-leg casts were then placed with the foot in neutral with some moulding of his medial plantar arch. The patient was subsequently was taken to Recovery in stable condition.,POSTOPERATIVE PLAN: , The patient will be hospitalized overnight for pain as per parents' request. The patient is to be strict nonweightbearing for at least 6 weeks. He is to follow up in the next 10 days for a check. We will plan of changing to short-leg casts in about 4 weeks postop. | surgery, myotonic muscular dystrophy, muscular dystrophy, planovalgus feet, achilles z-lengthening, subtalar arthrodesis, bilateral crawford subtalar arthrodesis, bilateral long leg cast, sinus tarsi, leg casts, tourniquet time, arthrodesis, intraoperative, fluoroscopy, tourniquet, subtalar, achilles, anesthesia, planovalgus, foot, bilateral, |
1,224 | Acute appendicitis, gangrenous. Appendectomy. | Surgery | Appendectomy - 1 | PREOPERATIVE DIAGNOSIS:, Acute appendicitis.,POSTOPERATIVE DIAGNOSIS: , Acute appendicitis, gangrenous.,PROCEDURE: , Appendectomy.,DESCRIPTION OF PROCEDURE: , The patient was taken to the operating room under urgent conditions. After having obtained an informed consent, he was placed in the operating room and under anesthesia. Followed by a time-out process, his abdominal wall was prepped and draped in the usual fashion. Antibiotics had been given prior to incision. A McBurney incision was performed and it carried out through the peritoneal cavity. Immediately there was purulent material seen in the area. Samples were taken for culture and sensitivity of aerobic and anaerobic sets. The appendix was markedly swollen particularly in its distal three-fourth, where the distal appendix showed an abscess formation and devitalization of the wall. There was quite a bit of local peritonitis. The mesoappendix was clamped, divided and ligated, and then the appendix was ligated and divided, and the stump buried with a pursestring suture of Vicryl and then a Z stitch. The area was abundantly irrigated with normal saline and also the pelvis. The distal foot of small bowel had been explored and because it delivered itself __________ the incision and showed no pathology.,Then the peritoneal and internal fascia were approximated with a suture of 0 Vicryl and then the incision was closed in layers and after each layer the wound was irrigated with normal saline. The skin was closed with a combination of a subcuticular suture of fine Monocryl followed by the application of Dermabond. The patient tolerated the procedure well. Estimated blood loss was minimal, and the patient was sent to the recovery room for recovery in satisfactory condition., | surgery, mcburney incision, abdominal, small bowel, acute appendicitis, appendectomy, gangrenous, appendix, |
1,225 | Acute appendicitis and 29-week pregnancy. Appendectomy. | Surgery | Appendectomy - 2 | PREOPERATIVE DIAGNOSES,1. Acute appendicitis.,2. 29-week pregnancy.,POSTOPERATIVE DIAGNOSES,1. Acute appendicitis.,2. 29-week pregnancy.,OPERATION: , Appendectomy.,DESCRIPTION OF THE PROCEDURE: ,After obtaining the informed consent including all risks and benefits of the procedure, the patient was urgently taken to the operating room where a spinal anesthetic was given and the patient's abdomen was prepped and draped in a usual fashion. Preoperative antibiotics were given. A time-out process was followed. Local anesthetics were infiltrated in the area of the proposed incision. A modified McBurney incision was performed. A very abnormal appendix was immediately found. There was a milky fluid around the area and this was cultured both for aerobic and anaerobic cultures. The distal end of the appendix had transformed itself into an abscess. The proximal portion was normal. The appendix was very friable and a no-touch technique was used. It was carefully dissected off the cecum, and then it was ligated and excised after the mesoappendix had been taken care of. Then the stump was buried with a pursestring of 2-0 Vicryl. The operative area was abundantly irrigated with warm saline and then closed in layers. The layer was further irrigated. A subcuticular suture of Monocryl was performed in the skin followed by the application of Dermabond.,Further local anesthetic was infiltrated at the end of the procedure in the operative area and the patient tolerated the procedure well, and with an estimated blood loss that was not consequential, was transferred from recovery to ICU in a satisfactory condition. | surgery, mcburney incision, appendectomy, appendicitis, appendix, |
1,226 | Aortoiliac occlusive disease. Aortobifemoral bypass. The aorta was of normal size and consistency consistent with arteriosclerosis. A 16x8 mm Gore-Tex graft was placed without difficulty. The femoral vessels were small somewhat thin and there was posterior packing, but satisfactory bypass was performed. | Surgery | Aortobifemoral Bypass | PREOPERATIVE DIAGNOSIS:, Aortoiliac occlusive disease.,POSTOPERATIVE DIAGNOSIS:, Aortoiliac occlusive disease.,PROCEDURE PERFORMED:, Aortobifemoral bypass.,OPERATIVE FINDINGS: , The patient was taken to the operating room. The abdominal contents were within normal limits. The aorta was of normal size and consistency consistent with arteriosclerosis. A 16x8 mm Gore-Tex graft was placed without difficulty. The femoral vessels were small somewhat thin and there was posterior packing, but satisfactory bypass was performed.,PROCEDURE: , The patient was taken to the operating room, placed in a supine position, and prepped and draped in the usual sterile manner with Betadine solution. A longitudinal incision was made after a Betadine-coated drape was placed over the incisional area. Longitudinal incision was made over each groin initially and carried down to the subcutaneous fat and fascia. Hemostasis was obtained with electrocautery. The common deep and superficial femoral arteries were exposed and then these incisions were covered with antibiotic soaked sponges. Attention was then turned to the abdomen, where a longitudinal incision was made from the pubis xiphoid, carried down subcutaneous fat and fascia. Hemostasis was obtained with electrocautery. The abdomen was entered above the umbilicus and then this was extended with care inferiorly as the patient has undergone previous abdominal surgery. Mild adhesions were lysed. The omentum was freed. The small and large intestine were run with no evidence of abnormalities. The liver and gallbladder were within normal limits. No abnormalities were noted. At this point, the Bookwalter retractor was placed. NG tube was placed in the stomach and placed on suction. The intestines were gently packed intraabdominally and laterally. The rest of the peritoneum was then opened. The aorta was cleared, both proximally and distally. The left iliac was completely occluded. The right iliac was to be cleansed. At this point, 5000 units of aqueous heparin was administered to allow take effect. The aorta was then clamped below the renal arteries and opened in a longitudinal fashion. A single lumbar was ligated with #3-0 Prolene. The inferior mesenteric artery was occluded intraluminally and required no suture closure. Care was taken to preserve collaterals. The aorta was measured, and a 16 mm Gore-Tex graft was brought on the field and anastomosed to the proximal aorta using #3-0 Prolene in a running fashion. Last stitch was tied. Hemostasis was excellent. The clamp was gradually removed and additional Prolene was placed in the right posterolateral aspect to obtain better hemostasis. At this point, strong pulses were present within the graft. The limbs were vented and irrigated. Using bimanual technique, the retroperitoneal tunnels were developed immediately on top of the iliac arteries into the groin. The grafts were then brought through these, care being taken to avoid twisting of the graft. At this point, the right iliac was then ligated using #0 Vicryl and the clamp was removed. Hemostasis was excellent. The right common femoral artery was then clamped proximally and distally, opened with #11 blade extended with Potts scissors. The graft was _____ and anastomosed to the artery using #5-0 Prolene in a continuous fashion with a stitch _______ running fashion. Prior to tying the last stitch, the graft and artery were vented and the last stitch was tied. Flow was initially restored proximally then distally with good results. Attention was then turned to the left groin and the artery grafts were likewise exposed, cleared proximally and distally. The artery was opened, extended with a Potts scissors and anastomosis was performed with #5-0 Prolene again with satisfactory hemostasis. The last stitch was tied. Strong pulses were present within the artery and graft itself. At this point, 25 mg of protamine was administered. The wounds were irrigated with antibiotic solution. The groins were repacked. Attention was then returned to the abdomen. The retroperitoneal area and the anastomotic sites were checked for bleeding and none was present. The shell of the aorta was closed over the proximal anastomosis and the retroperitoneum was then repaired over the remaining portions of the graft. The intraabdominal contents were then allowed to resume their normal position. There was no evidence of ischemia to the large or small bowel. At this point, the omentum and stomach were repositioned. The abdominal wall was closed in a running single layer fashion using #1 PDS. The skin was closed with skin staples. The groins were again irrigated, closed with #3-0 Vicryl and #4-0 undyed Vicryl and Steri-Strips. The patient was then taken into the recovery room in satisfactory condition after tolerating the procedure well. Sponges and instrument counts were correct. Estimated blood loss 900 cc. | surgery, aorta, bypass, arteriosclerosis, abdominal contents, aortoiliac occlusive disease, gore tex graft, aortobifemoral bypass, longitudinal incision, aortobifemoral, hemostasis, artery, graft, |
1,227 | Aortogram with bilateral, segmental lower extremity run off. Left leg claudication. The patient presents with lower extremity claudication. | Surgery | Aortogram - Leg claudication. | PREPROCEDURE DIAGNOSIS:, Left leg claudication.,POSTPROCEDURE DIAGNOSIS: , Left leg claudication.,OPERATION PERFORMED: , Aortogram with bilateral, segmental lower extremity run off.,ANESTHESIA: , Conscious sedation.,INDICATION FOR PROCEDURE: ,The patient presents with lower extremity claudication. She is a 68-year-old woman, who is very fearful of the aforementioned procedures. Risks and benefits of the procedure were explained to her to include bleeding, infection, arterial trauma requiring surgery, access issues and recurrence. She appears to understand and agrees to proceed.,DESCRIPTION OF PROCEDURE: , The patient was taken to the Angio Suite, placed in a supine position. After adequate conscious sedation, both groins were prepped with Chloraseptic prep. Cloth towels and paper drapes were placed. Local anesthesia was administered in the common femoral artery and using ultrasound guidance, the common femoral artery was accessed. Guidewire was threaded followed by a ,4-French sheath. Through the 4-French sheath a 4-French Omni flush catheter was placed. The glidewire was removed and contrast administered to identify the level of the renal artery. Using power injector an aortogram proceeded.,The catheter was then pulled down to the aortic bifurcation. A timed run-off view of both legs was performed and due to a very abnormal and delayed run-off in the left, I opted to perform an angiogram of the left lower extremity with an isolated approach. The catheter was pulled down to the aortic bifurcation and using a glidewire, I obtained access to the contralateral left external iliac artery. The Omni flush catheter was advanced to the left distal external iliac artery. The glidewire rather exchanged for an Amplatz stiff wire. This was left in place and the 4-French sheath removed and replaced with a 6-French destination 45-cm sheath. This was advanced into the proximal superficial femoral artery and an angiogram performed. I identified a functionally occluded distal superficial femoral artery and after obtaining views of the run off made plans for angioplasty.,The patient was given 5000 units of heparin and this was allowed to circulate. A glidewire was carefully advanced using Roadmapping techniques through the functionally occluded blood vessels. A 4-mm x 4-cm angioplasty balloon was used to dilate the area in question.,Final views after dilatation revealed a dissection. A search for a 5-mm stent was performed, but none of this was available. For this reason, I used a 6-mm x 80-mm marked stent and placed this at the distal superficial femoral artery. Post dilatation was performed with a 4-mm angioplasty balloon. Further views of the left lower extremity showed irregular change in the popliteal artery. No significant stenosis could be identified in the left popliteal artery and noninvasive scan. For this reason, I chose not to treat any further areas in the left leg.,I then performed closure of the right femoral artery with a 6-French Angio-Seal device. Attention was turned to the left femoral artery and local anesthesia administered. Access was obtained with the ultrasound and the femoral artery identified. Guidewire was threaded followed by a 4-French sheath. This was immediately exchanged for the 6-French destination sheath after the glidewire was used to access the distal external iliac artery. The glidewire was exchanged for the Amplatz stiff wire to place the destination sheath. The destination was placed in the proximal superficial femoral artery and angiogram obtained. Initial views had been obtained from the right femoral sheath before removal.,Views of the right superficial femoral artery demonstrated significant stenosis with accelerated velocities in the popliteal and superficial femoral artery. For this reason, I performed the angioplasty of the superficial femoral artery using the 4-mm balloon. A minimal dissection plane measuring less than 1 cm was identified at the proximal area of dilatation. No further significant abnormality was identified. To avoid placing a stent in the small vessel I left it alone and approached the popliteal artery. A 3-mm balloon was chosen to dilate a 50 to 79% popliteal artery stenosis. Reasonable use were obtained and possibly a 4-mm balloon could have been used. However, due to her propensity for dissection I opted not to. I then exchanged the glidewire for an O1 for Thruway guidewire using an exchange length. This was placed into the left posterior tibial artery. A 2-mm balloon was used to dilate the orifice of the posterior tibial artery. I then moved the wire to the perineal artery and dilated the proximal aspect of this vessel. Final images showed improved run-off to the right calf. The destination sheath was pulled back into the left external iliac artery and an Angio-Seal deployed.,FINDINGS: , Aortogram demonstrates a dual right renal artery with the inferior renal artery supplying the lower one third of the right renal parenchyma. No evidence of renal artery stenosis is noted bilaterally. There is a single left renal artery. The infrarenal aorta, both common iliac and the external iliac arteries are normal. On the right, a superficial femoral artery is widely patent and normal proximally. At the distal third of the thigh there is diffuse disease with moderate stenosis noted. Moderate stenosis is also noted in the popliteal artery and single vessel run-off through the posterior tibial artery is noted. The perineal artery is functionally occluded at the midcalf. The dorsal pedal artery filled by collateral at the high ankle level.,On the left, the proximal superficial femoral artery is patent. Again, at the distal third of the thigh, there is a functional occlusion of the superficial femoral artery with poor collateralization to the high popliteal artery. This was successfully treated with angioplasty and a stent placement. The popliteal artery is diffusely diseased without focal stenosis. The tibioperoneal trunk is patent and the anterior tibial artery occluded at its orifice.,IMPRESSION,1. Normal bilateral renal arteries with a small accessory right renal artery.,2. Normal infrarenal aorta as well as normal bilateral common and external iliac arteries.,3. The proximal right renal artery is normal with moderately severe stenosis in the superficial femoral popliteal and tibial arteries. Successful angioplasty with reasonable results in the distal superficial femoral, popliteal and proximal posterior tibial artery as described.,4. Normal proximal left superficial femoral artery with functional occlusion of the distal left superficial femoral artery successfully treated with angioplasty and stent placement. Run-off to the left lower extremity is via a patent perineal and posterior tibial artery. | surgery, claudication, extremity run off, angio suite, superficial femoral artery, popliteal, superficial, femoral, aortogram, artery, balloon, glidewire, angioplasty, stenosis, renal, |
1,228 | Rotated cuff tear, right shoulder. Glenoid labrum tear. Arthroscopy with arthroscopic glenoid labrum debridement, subacromial decompression, and rotator cuff repair, right shoulder. | Surgery | Arthroscopic Rotator Cuff Repair - 1 | PREOPERATIVE DIAGNOSIS: , Rotated cuff tear, right shoulder.,POSTOPERATIVE DIAGNOSES:,1. Rotated cuff tear, right shoulder.,2. Glenoid labrum tear.,PROCEDURE PERFORMED:,1. Arthroscopy with arthroscopic glenoid labrum debridement.,2. Subacromial decompression.,3. Rotator cuff repair, right shoulder.,SPECIFICATIONS:, Intraoperative procedure was done at Inpatient Operative Suite, room #1 at ABCD Hospital. This was done under interscalene and subsequent general anesthetic in the modified beach chair position.,HISTORY AND GROSS FINDINGS: , The patient is a 48-year-old with male who has been suffering increasing right shoulder pain for a number of months prior to surgical intervention. He was completely refractory to conservative outpatient therapy. After discussing the alternative care as well as the advantages, disadvantages, risks, complications, and expectations, he elected to undergo the above stated procedure on this date.,Intraarticularly, the joint was observed. There was noted to be a degenerative glenoid labrum tear. The biceps complex was otherwise intact. There were minimal degenerative changes at the glenohumeral joint. Rotator cuff tear was appreciated on the inner surface. Subacromially, the same was true. This was an elliptical to V-type tear. The patient has a grossly positive type III acromion.,OPERATIVE PROCEDURE: , The patient was laid supine on the operating table after receiving interscalene and then general anesthetic by the Anesthesia Department. He was safely placed in modified beach chair position. He was prepped and draped in the usual sterile manner. Portals were created outside to end, posterior to anterior, and ultimately laterally in the typical fashion. Upon complete diagnostic arthroscopy was carried out in the intraarticular aspect of the joint, a 4.2 meniscus shaver was placed anteriorly with the scope posteriorly. Debridement was carried out to the glenoid labrum. The biceps was probed and noted to be intact. Undersurface of the rotator cuff was debrided with the shaver along with debridement of the subchondral region of the greater tuberosity attachment.,After this, instrumentation was removed. The scope was placed subacromially and a lateral portal created. Gross bursectomy was carried out in a stepwise fashion to the top part of the cuff as well as in the gutters. An anterolateral portal was created. Sutures were placed via express silk as well as other sutures with a #2 fiber wire. With passing of the suture, they were tied with a slip-tight knot and then two half stitches. There was excellent reduction of the tear. Superolateral portal was then created. A #1 Mitek suture anchor was then placed in the posterior cuff to bring this over to bleeding bone. _______ suture was placed. The implant was put into place. The loop was grabbed and it was impacted in the previously drilled holes. There was excellent reduction of the tear.,Trial range of motion was carried out and seemed to be satisfactory.,Prior to this, a subacromial decompression was accomplished after release of CA ligament with the vapor Bovie. A 4.8 motorized barrel burr was utilized to sequentially take this down from the type III acromion to a flat type I acromion.,After all was done, copious irrigation was carried out throughout the joint. Gross bursectomy lightly was carried out to remove all bony elements. A pain buster catheter was placed through a separate portal and cut to length. 0.5% Marcaine was instilled after portals were closed with #4-0 nylon. Adaptic, 4 x 4s, ABDs, and Elastoplast tape placed for dressing. The patient was ultimately transferred to his cart and PACU in apparent satisfactory condition. Expected surgical prognosis of this patient is fair. | surgery, subacromial decompression, rotator cuff repair, arthroscopic glenoid labrum debridement, arthroscopy, glenoid labrum tear, glenoid labrum, cuff, tear, arthroscopic, subacromial, decompression, debridement, rotator, glenoid, labrum, shoulder, |
1,229 | Aortic valve replacement using a mechanical valve and two-vessel coronary artery bypass grafting procedure using saphenous vein graft to the first obtuse marginal artery and left radial artery graft to the left anterior descending artery. | Surgery | Aortic Valve Replacement | DIAGNOSIS: , Aortic valve stenosis with coronary artery disease associated with congestive heart failure. The patient has diabetes and is morbidly obese.,PROCEDURES: , Aortic valve replacement using a mechanical valve and two-vessel coronary artery bypass grafting procedure using saphenous vein graft to the first obtuse marginal artery and left radial artery graft to the left anterior descending artery.,ANESTHESIA: , General endotracheal,INCISION: , Median sternotomy,INDICATIONS: , The patient presented with severe congestive heart failure associated with the patient's severe diabetes. The patient was found to have moderately stenotic aortic valve. In addition, The patient had significant coronary artery disease consisting of a chronically occluded right coronary artery but a very important large obtuse marginal artery coming off as the main circumflex system. The patient also has a left anterior descending artery which has moderate disease and this supplies quite a bit of collateral to the patient's right system. It was decided to perform a valve replacement as well as coronary artery bypass grafting procedure.,FINDINGS: , The left ventricle is certainly hypertrophied· The aortic valve leaflet is calcified and a severe restrictive leaflet motion. It is a tricuspid type of valve. The coronary artery consists of a large left anterior descending artery which is associated with 60% stenosis but a large obtuse marginal artery which has a tight proximal stenosis.,The radial artery was used for the left anterior descending artery. Flow was excellent. Looking at the targets in the posterior descending artery territory, there did not appear to be any large branches. On the angiogram these vessels appeared to be quite small. Because this is a chronically occluded vessel and the patient has limited conduit due to the patient's massive obesity, attempt to bypass to this area was not undertaken. The patient was brought to the operating room,PROCEDURE: , The patient was brought to the operating room and placed in supine position. A median sternotomy incision was carried out and conduits were taken from the left arm as well as the right thigh. The patient weighs nearly three hundred pounds. There was concern as to taking down the left internal mammary artery. Because the radial artery appeared to be a good conduit The patient would have arterial graft to the left anterior descending artery territory. The patient was cannulated after the aorta and atrium were exposed and full heparinization.,The patient went on cardiopulmonary bypass and the aortic cross-clamp was applied Cardioplegia was delivered through the coronary sinuses in a retrograde manner. The patient was cooled to 32 degrees. Iced slush was applied to the heart. The aortic valve was then exposed through the aortic root by transverse incision. The valve leaflets were removed and the #23 St. Jude mechanical valve was secured into position by circumferential pledgeted sutures. At this point, aortotomy was closed.,The first obtuse marginal artery was a very large target and the vein graft to this target indeed produced an excellent amount of flow. Proximal anastomosis was then carried out to the foot of the aorta. The left anterior descending artery does not have severe disease but is also a very good target and the radial artery was anastomosed to this target in an end-to-side manner. The two proximal anastomoses were then carried out to the root of the aorta.,The patient came off cardiopulmonary bypass after aortic cross-clamp was released. The patient was adequately warmed. Protamine was given without adverse effect. Sternal closure was then done using wires. The subcutaneous layers were closed using Vicryl suture. The skin was approximated using staples. | surgery, coronary artery bypass grafting, saphenous vein graft, radial artery graft, coronary artery disease, congestive heart failure, descending artery territory, aortic cross clamp, aortic valve replacement, coronary artery bypass, obtuse marginal artery, anterior descending artery, mechanical valve, artery bypass, bypass grafting, marginal artery, radial artery, aortic valve, coronary artery, anterior descending, descending artery, valve, artery, aortic, grafting, |
1,230 | Laparoscopic appendectomy and peritoneal toilet and photos. Pelvic inflammatory disease and periappendicitis. | Surgery | Appendectomy - Laparoscopic | PREOPERATIVE DIAGNOSIS:, Acute appendicitis.,POSTOPERATIVE DIAGNOSES:,1. Pelvic inflammatory disease.,2. Periappendicitis.,PROCEDURE PERFORMED:,1. Laparoscopic appendectomy.,2. Peritoneal toilet and photos.,ANESTHESIA: ,General.,COMPLICATIONS: , None.,ESTIMATED BLOOD LOSS:, Less than 10 cc.,INDICATIONS FOR PROCEDURE: , The patient is a 31-year-old African-American female who presented with right lower quadrant abdominal pain presented with acute appendicitis. She also had mild leukocytosis with bright blood cell count of 12,000. The necessity for diagnostic laparoscopy was explained and possible appendectomy. The patient is agreeable to proceed and signed preoperatively informed consent.,PROCEDURE: , The patient was taken to the operative suite and placed in the supine position under general anesthesia by Anesthesia Department.,The preoperative Foley, antibiotics, and NG tube are placed for decompression and the anterior abdominal wall was prepped and draped in the usual sterile fashion and infraumbilical incision is performed with a #10 blade scalpel with anterior and superior traction on the abdominal wall. A Veress needle was introduced and 15 mm pneumoperitoneum is created with CO2 insufflation. At this point, the Veress needle was removed and a 10 mm trocar is introduced intraperitoneally. A second 5 mm port was introduced in the right upper quadrant under direct visualization and blunted graspers were introduced to bring the appendix into view. With the aid of a laparoscope, the pelvis was visualized. The ovaries are brought in views and photos are taken. There is evidence of a purulence in the cul-de-sac and ________ with a right ovarian hemorrhagic cyst. Attention was then turned on the right lower quadrant. The retrocecal appendix is freed with peritoneal adhesions removed with Endoshears. Attention was turned to the suprapubic area. The 12 mm port was introduced under direct visualization and the mesoappendix was identified. A 45 mm endovascular stapling device was fired across the mesoappendix and the base of the appendix sequentially with no evidence of bleeding or leakage from the staple line. Next, ________ tube was used to obtain Gram stain and cultures of the pelvic fluid and a pelvic toilet was performed with copious irrigation of sterile saline. Next, attention was turned to the right upper quadrant. There is evidence of adhesions from the liver surface to the anterior abdominal wall consistent with Fitz-Hugh-Curtis syndrome also a prior pelvic inflammatory disease. All free fluid is aspirated and patient's all port sites are removed under direct visualization and the appendix is submitted to pathology for final pathology. Once the ports are removed the pneumoperitoneum is allowed to escape for patient's postoperative comfort and two larger port sites at the suprapubic and infraumbilical sites are closed with #0 Vicryl suture on a UR-6 needle. Local anesthetic is infiltrated at L3 port sites for postoperative analgesia and #4-0 Vicryl subcuticular closure is performed with undyed Vicryl. Steri-Strips are applied along with sterile dressings. The patient was awakened from anesthesia without difficulty and transferred to recovery room with postoperative broad-spectrum IV antibiotics in the General Medical Floor. Routine postoperative care will be continued on this patient. | surgery, acute appendicitis, periappendicitis, peritoneal toilet, pelvic inflammatory disease, abdominal wall, direct visualization, toilet, appendectomy, mesoappendix, laparoscopic, port, inflammatory |
1,231 | Appendicitis, nonperforated. Appendectomy. A transverse right lower quadrant incision was made directly over the point of maximal tenderness. | Surgery | Appendectomy | PREOPERATIVE DIAGNOSIS: , Appendicitis.,POSTOPERATIVE DIAGNOSIS:, Appendicitis, nonperforated.,PROCEDURE PERFORMED:, Appendectomy.,ANESTHESIA: , General endotracheal.,PROCEDURE: , After informed consent was obtained, the patient was brought to the operative suite and placed supine on the operating table. General endotracheal anesthesia was induced without incident. The patient was prepped and draped in the usual sterile manner.,A transverse right lower quadrant incision was made directly over the point of maximal tenderness. Sharp dissection utilizing Bovie electrocautery was used to expose the external oblique fascia. The fascia of the external oblique was incised in the direction of the fibers, and the muscle was spread with a clamp. The internal oblique fascia was similarly incised and its muscular fibers were similarly spread. The transversus abdominis muscle, transversalis fascia and peritoneum were incised sharply gaining entrance into the abdominal cavity without incident. Upon entering the peritoneal cavity, the peritoneal fluid was noted to be clean.,The cecum was then grasped along the taenia with a moist gauze sponge and was gently mobilized into the wound. After the appendix was fully visualized, the mesentery was divided between Kelly clamps and ligated with 2-0 Vicryl ties. The base of the appendix was crushed with a clamp and then the clamp was reapplied proximally on the appendix. The base was ligated with 2-0 Vicryl tie over the crushed area, and the appendix amputated along the clamp. The stump of the appendix was cauterized and the cecum was returned to the abdomen.,The peritoneum was irrigated with warm sterile saline. The mesoappendix and cecum were examined for hemostasis which was present. The wound was closed in layers using 2-0 Vicryl for the peritoneum and 0 Vicryl for the internal oblique and external oblique layers. The skin incision was approximated with 4-0 Monocryl in a subcuticular fashion. The skin was prepped with benzoin, and Steri-Strips were applied. A dressing was placed on the wound. All surgical counts were reported as correct.,Having tolerated the procedure well, the patient was subsequently extubated and taken to the recovery room in good and stable condition. | surgery, peritoneal cavity, peritoneal fluid, abdominal cavity, abdominis muscle, transversalis fascia, peritoneum, internal oblique fascia, vicryl ties, appendectomy, appendicitis, appendix, |
1,232 | Irrigation and debridement of skin, subcutaneous tissue, fascia and bone associated with an open fracture and placement of antibiotic-impregnated beads. Open calcaneus fracture on the right. | Surgery | Antibiotic-Impregnated Beads Placement | PREOPERATIVE DIAGNOSIS:, Open calcaneus fracture on the right.,POSTOPERATIVE DIAGNOSIS:, Open calcaneus fracture on the right.,PROCEDURES:, ,1. Irrigation and debridement of skin, subcutaneous tissue, fascia and bone associated with an open fracture.,2. Placement of antibiotic-impregnated beads.,ANESTHESIA:, General.,BLOOD LOSS:, Minimal.,COMPLICATIONS:, None.,FINDINGS:, Healing skin with no gross purulence identified, some fibrinous material around the beads.,SUMMARY:, After informed consent was obtained and verified, the patient was brought to the operating room and placed supine on the operating table. After uneventful general anesthesia was obtained, her right leg was sterilely prepped and draped in a normal fashion. The tourniquet was inflated and the previous wound was opened. Dr. X came in to look at the wound and the beads were removed, all 25 beads were extracted, and pulsatile lavage, and curette, etc., were used to debride the wound. The wound margins were healthy with the exception of very central triangular incision area. The edges were debrided and then 19 antibiotic-impregnated beads with gentamicin and tobramycin were inserted and the wound was further closed today.,The skin edges were approximated under minimal tension. The soft dressing was placed. An Ace was placed. She was awakened from the anesthesia and taken to recovery room in a stable condition. Final needle, instrument, and sponge counts were correct. | surgery, open calcaneus fracture, irrigation and debridement, antibiotic impregnated beads, irrigation, subcutaneous, placement, debridement, calcaneus, fracture, wound, beads, antibiotic |
1,233 | Dementia and aortoiliac occlusive disease bilaterally. Aortobifemoral bypass surgery utilizing a bifurcated Hemashield graft. | Surgery | Aortobifemoral Bypass - 1 | PREOPERATIVE DIAGNOSIS,1. Aortoiliac occlusive disease bilaterally.,2. Dementia.,POSTOPERATIVE DIAGNOSIS,1. Aortoiliac occlusive disease bilaterally.,2. Dementia.,OPERATION: , Aortobifemoral bypass surgery utilizing a bifurcated Hemashield graft.,ANESTHESIA:, General endotracheal,ESTIMATED BLOOD LOSS: , 300 cc,INTRAVENOUS FLUIDS: , 1200 cc of crystalloid,URINE OUTPUT: , 250 cc,OPERATION IN DETAIL: , After obtaining informed consent from the patient, including a thorough explanation of the risks and benefits of the aforementioned procedure, the patient was taken to the operating room and general endotracheal anesthesia was administered. Note that previously the patient was found to have some baseline dementia, although slight. The patient was seen and evaluated by the neurology team, who cleared the patient for surgery. The patient was taken to the operating room and general endotracheal anesthesia was administered. The abdomen was prepped and draped in the standard surgical fashion. We first began our dissection by using a #10-blade scalpel to incise the skin over the femoral artery in the groin bilaterally. Dissection was carried down to the level of the femoral vessels using Bovie electrocautery. The common femoral, superficial femoral, and profunda femoris arteries were encircled and dissected out peripherally. Vessel loops were placed around the aforementioned arteries. After doing so, we turned our attention to beginning our abdominal dissection. We used a #10-blade scalpel to make a midline laparotomy incision. Dissection was carried down to the level of the fascia using Bovie electrocautery. The abdomen was opened and an Omni retractor was positioned. The aorta was dissected out in the abdomen. The left femoral vein was identified. There was a nicely clampable portion of aorta visible. We, as mentioned, placed our Omni retractor and then turned our attention to performing our anastomosis. Full-dose heparin was given. Next, vascular clamps were applied to the iliac vessels as well as to the proximal aorta just below the renal vessels. A #11-blade scalpel was used to make an arteriotomy in the aorta, which was lengthened both proximally and distally using Potts scissors. We then beveled our proximal graft and constructed an end graft-to-side artery anastomosis using 3-0 Prolene in a running fashion. Upon completion of our anastomosis, we flushed our graft and noted there was no evidence of a leak from the newly constructed anastomosis. We then created our tunnels over the iliac vessels. We pulled the distal limbs over our ABF graft into the groin. We then proceeded to perform our right anastomosis first. We applied vascular clamps on the proximal common femoral, profunda, and superficial femoral arteries. We incised the common femoral artery and lengthened our arteriotomy in the vessel both proximally and distally. We then footed the graft down onto the common femoral artery to the level of the SFA and constructed our anastomosis using 6-0 Prolene in a running fashion. Upon completion of our anastomosis, we flushed the common femoral, SFA, and profunda femoris arteries. We then removed our clamp. We opened the limb more proximally in the abdomen on the right side. We then turned our attention to the left side and similarly placed our vascular clamps. We used a #11-blade scalpel to make an arteriotomy in the vessel. We then lengthened our arteriotomy both proximally and distally again onto the SFA. We constructed a footed end graft-to-side artery anastomosis using 6-0 Prolene in a running fashion. Upon completion of our anastomosis, we opened our clamps. There was no noticeable leak from the newly constructed anastomosis. We checked our proximal graft to aortic anastomosis, which was noted to be in good condition. We then gave full-dose protamine. We closed the peritoneum over the graft with 4-0 Vicryl in a running fashion. The abdomen was closed with #1 nylon in a running fashion. The skin was closed with subcuticular 4-0 Monocryl in a running subcuticular fashion. The instrument and sponge count was correct at end of case. Patient tolerated the procedure well and was transferred to the intensive care unit in good condition. | surgery, bifurcated, hemashield graft, aortoiliac occlusive disease, aortobifemoral bypass, vascular clamps, common femoral, graft, femoral, anastomosis, aortobifemoral, aortoiliac, proximal, arteriotomy, bypass, artery, endotracheal, vessels, |
1,234 | Anterior cervical discectomy for neural decompression and anterior interbody fusion C5-C6 utilizing Bengal cage. | Surgery | Anterior Cervical Discectomy & Interbody Fusion - 3 | PREOPERATIVE DIAGNOSES:, ,1. Spondylosis with cervical stenosis C5-C6 greater than C4-C5, C6-C7, (721.0, 723.0).,2. Neck pain with left radiculopathy, progressive (723.1/723.4).,3. Headaches, progressive (784.0).,POSTOPERATIVE DIAGNOSES:, ,1. Spondylosis with cervical stenosis C5-C6 greater than C4-C5, C6-C7, (721.0, 723.0).,2. Neck pain with left radiculopathy, progressive (723.1/723.4).,3. Headaches, progressive (784.0).,PROCEDURES:, ,1. Anterior cervical discectomy at C5-C6 for neural decompression (63075).,2. Anterior interbody fusion C5-C6 (22554) utilizing Bengal cage (22851).,3. Anterior cervical instrumentation at C5-C6 for stabilization by Uniplate construction at C5-C6 (22845); with intraoperative x-ray x2.,SERVICE: , Neurosurgery,ANESTHESIA:, | surgery, spondylosis, neck pain, headaches, decompression, uniplate, anterior cervical discectomy, neural decompression, cervical stenosis, prevertebral space, antibiotic solution, cervical discectomy, interbody fusion, bengal cage, interbody, anterior, cervical, discectomy, |
1,235 | Anterior cervical discectomy with spinal cord and spinal canal decompression and Anterior interbody fusion at C5-C6 utilizing Bengal cage. | Surgery | Anterior Cervical Discectomy & Interbody Fusion - 2 | PREOPERATIVE DIAGNOSES: ,1. Large herniated nucleus pulposus, C5-C6 with myelopathy (722.21).,2. Cervical spondylosis.,3. Cervical stenosis, C5-C6 secondary to above (723.0).,POSTOPERATIVE DIAGNOSES: ,1. Large herniated nucleus pulposus, C5-C6 with myelopathy (722.21).,2. Cervical spondylosis.,3. Cervical stenosis, C5-C6 secondary to above (723.0), with surgical findings confirmed.,PROCEDURES: , ,1. Anterior cervical discectomy at C5-C6 with spinal cord and spinal canal decompression (63075).,2. Anterior interbody fusion at C5-C6, (22554) utilizing Bengal cage (22851).,3. Anterior instrumentation for stabilization by Uniplate construction, C5-C6, (22845); with intraoperative x-ray times two.,ANESTHESIA: , General.,SERVICE: , Neurosurgery.,OPERATION: ,The patient was brought into the operating room, placed in a supine position where general anesthesia was administered. Then the anterior aspect of the neck was prepped and draped in a routine sterile fashion. A linear skin incision was made in the skin fold line from just to the right of the midline to the leading edge of the right sternocleidomastoid muscle and taken sharply to platysma, which was dissected only in a subplatysmal manner bluntly, and with only blunt dissection at the prevertebral space where a localizing intraoperative x-ray was obtained, once self-retaining retractors were placed along the mesial edge of a cauterized longus colli muscle, to protect surrounding tissues throughout the remainder of the case. A prominent anterior osteophyte at C5-C6 was then localized, compared to preoperative studies in the usual fashion intraoperatively, and the osteophyte was excised with a rongeur and bony fragments saved. This allowed for an annulotomy, which was carried out with a #11 blade and discectomy, removed with straight disc forceps portions of the disc, which were sent to Pathology for a permanent section. Residual osteophytes and disc fragments were removed with 1 and 2-mm micro Kerrison rongeurs as necessary as drilling extended into normal cortical and cancellous elements widely laterally as well. A hypertrophied ligament and prominent posterior spurs were excised as well until the dura bulged into the interspace, a sign of a decompressed status. At no time during the case was evidence of CSF leakage, and hemostasis was readily achieved with pledgets of Gelfoam subsequently removed with copious amounts of antibiotic irrigation. Once the decompression was inspected with a double ball dissector and all found to be completely decompressed, and the dura bulged at the interspace, and pulsated, then a Bengal cage was filled with the patient's own bone elements and fusion putty and countersunk into position, and was quite tightly applied. Further stability was added nonetheless with an appropriate size Uniplate, which was placed of appropriate size with appropriate size screws and these were locked into place in the usual manner. The wound was inspected, and irrigated again with antibiotic solution and after further inspection was finally closed in a routine closure in a multiple layer event by first approximation of the platysma with interrupted 3-0 Vicryl, and the skin with a subcuticular stitch of 4-0 Vicryl, and this was Steri-Stripped for reinforcement, and a sterile dressing was applied, incorporating a Penrose drain, which was carried from the prevertebral space externally to the skin wound and safety pin for security in the usual manner. Once the sterile dressing was applied, the patient was taken from the operating room to the recovery area having left in stable condition.,At the conclusion of the case, all instruments, needle, and sponge counts were accurate and correct, and there were no intraoperative complications of any type. | surgery, herniated nucleus pulposus, myelopathy, cervical spondylosis, cervical stenosis, anterior instrumentation, uniplate, decompression, anterior cervical discectomy, spinal cord, spinal canal, sterile dressing, interbody fusion, bengal cage, interbody, cervical, anterior, discectomy, |
1,236 | Anterior lumbar fusion, L4-L5, L5-S1, PEEK vertebral spacer, structural autograft from L5 vertebral body, BMP and anterior plate. Severe low back pain. | Surgery | Anterior Lumbar Fusion | PREOPERATIVE DIAGNOSIS: , Severe low back pain.,POSTOPERATIVE DIAGNOSIS: , Severe low back pain.,OPERATIONS PERFORMED: , Anterior lumbar fusion, L4-L5, L5-S1, PEEK vertebral spacer, structural autograft from L5 vertebral body, BMP and anterior plate.,ANESTHESIA:, General endotracheal.,ESTIMATED BLOOD LOSS: , Less than 50 mL.,DRAINS:, None.,COMPLICATIONS: , None.,PATHOLOGICAL FINDINGS:, Dr. X made the approach and once we were at the L5-S1 disk space, we removed the disk and we placed a 13-mm PEEK vertebral spacer filled with a core of bone taken from the L5 vertebral body. This was filled with a 15 x 20-mm Chronos VerteFill tricalcium phosphate plug. At L4-L5, we used a 13-mm PEEK vertebral spacer with structural autograft and BMP, and then we placed a two-level 87-mm Integra sacral plate with 28 x 6-mm screws, two each at L4 and L5 and 36 x 6-mm screws at S1.,OPERATION IN DETAIL:, The patient was placed under general endotracheal anesthesia. The abdomen was prepped and draped in the usual fashion. Dr. X made the approach, and once the L5-S1 disk space was identified, we incised this with a knife and then removed a large core of bone taking rotating cutters. I was able to remove additional disk space and score the vertebral bodies. The rest of the disk removal was done with the curette, scraping the endplates. I tried various sized spacers, and at this point, we exposed the L5 body and took a dowel from the body and filled the hole with a 15 x 20-mm Chronos VerteFill tricalcium phosphate plug. Half of this was used to fill the spacer at L5-S1, BMP was placed in the spacer as well and then it was tapped into place. We then moved the vessels over the opposite way approaching the L4-L5 disk space laterally, and the disk was removed in a similar fashion and we also used a 13-mm PEEK vertebral spacer, but this is the variety that we could put in from one side. This was filled with bone and BMP as well. Once this was done, we were able to place an 87-mm Integra sacral plate down over the three vertebral bodies and place these screws. Following this, bleeding points were controlled and Dr. X proceeded with the closure of the abdomen.,SUMMARY: , This is a 51-year-old man who reports 15-year history of low back pain and intermittent bilateral leg pain and achiness. He has tried multiple conservative treatments including physical therapy, epidural steroid injections, etc. MRI scan shows a very degenerated disk at L5-S1, less so at L3-L4 and L4-L5. A discogram was positive with the lower 3 levels, but he has pain, which starts below the iliac crest and I feel that the L3-L4 disk is probably that symptomatic. An anterior lumbar interbody fusion was suggested. Procedure, risks, and complications were explained. | surgery, peek vertebral spacer, autograft, anterior lumbar fusion, lumbar fusion, vertebral body, vertebral spacer, vertebral, spacer, anterior, lumbar, fusion, |
1,237 | Arthroscopy of the left knee was performed with the anterior cruciate ligament reconstruction. Removal of loose bodies. Medial femoral chondroplasty and meniscoplasty. | Surgery | Anterior Cruciate Ligament Reconstruction | PREOPERATIVE DIAGNOSIS: , Anterior cruciate ligament rupture.,POSTOPERATIVE DIAGNOSES:,1. Anterior cruciate ligament rupture.,2. Medial meniscal tear.,3. Medial femoral chondromalacia.,4. Intraarticular loose bodies.,PROCEDURE PERFORMED:,1. Arthroscopy of the left knee was performed with the anterior cruciate ligament reconstruction.,2. Removal of loose bodies.,3. Medial femoral chondroplasty.,4. Medial meniscoplasty.,OPERATIVE PROCEDURE: ,The patient was taken to the operative suite, placed in supine position, and administered a general anesthetic by the Department of Anesthesia. Following this, the knee was sterilely prepped and draped as discussed for this procedure. The inferolateral and inferomedial portals were then established; however, prior to this, a graft was harvested from the semitendinosus and gracilis region. After the notch was identified, then ACL was confirmed and ruptured. There was noted to be a torn, slipped up area of the medial meniscus, which was impinging and impinged on the articular surface. The snare was smoothed out. Entire area was thoroughly irrigated. Following this, there was noted in fact to be significant degenerative changes from this impingement of the meniscus again to the periarticular cartilage. The areas of the worn away portion of the medial femoral condyle was then debrided and ________ chondroplasty was then performed of this area in order to stimulate bleeding and healing. There were multiple loose bodies noted in the knee and these were then __________ and then removed. The tibial and femoral drill holes were then established and the graft was then put in place, both which locations after a notchplasty was performed. The knee was taken through a full range of motion without any impingement. An Endobutton was used for proximal fixation. Distal fixation was obtained with an independent screw and a staple. The patient was then taken to Postanesthesia Care Unit at the conclusion of the procedure., | surgery, femoral chondroplasty, intraarticular loose bodies, anterior cruciate ligament reconstruction, anterior, arthroscopy, meniscoplasty, fixation, reconstruction, chondroplasty, ligament, femoral, intraarticular, medial |
1,238 | C5-C6 anterior cervical discectomy, allograft fusion, and anterior plating. | Surgery | Anterior Cervical Discectomy & Fusion - 8 | PROCEDURES PERFORMED: , C5-C6 anterior cervical discectomy, allograft fusion, and anterior plating.,ESTIMATED BLOOD LOSS: , 10 mL.,CLINICAL NOTE: , This is a 57-year-old gentleman with refractory neck pain with single-level degeneration of the cervical spine and there was also some arm pain. We decided go ahead with anterior cervical discectomy at C5-C6 and fusion. The risks of lack of pain relief, paralysis, hoarse voice, nerve injuries, and infection were explained and the patient agreed to proceed.,DESCRIPTION OF PROCEDURE: ,The patient was brought to the operating room where a general endotracheal anesthesia was induced without complication. The patient was placed in the slightly extended position with the neck and the head was restrained in a doughnut and the occiput was restrained by the doughnut. He had tape placed over the shoulders during intraoperative x-rays and his elbows were well padded. The tape was placed and his arms were well padded. He was prepped and draped in a sterile fashion. A linear incision was fashioned at the cricothyroid level from near the midline to over the sternocleidomastoid muscle. We separated the platysma from the subcutaneous tissue and then opened the platysma along the medial border of the sternocleidomastoid muscle. We then dissected sharply medial to carotid artery, which we palpated to the prevertebral region. We placed Caspar retractors for medial and lateral exposure over the C5-C6 disc space, which we confirmed with the lateral cervical spine x-ray including 18-gauge needle in the disc space. We then marked the disc space. We then drilled off ventral osteophyte as well as osteophyte creating concavity within the disc space. We then under magnification removed all the disc material, we could possibly see down to bleeding bone and both the endplates. We took down posterior longitudinal ligament as well. We incised the 6-mm cornerstone bone. We placed a 6-mm parallel medium bone nicely into the disc space. We then sized a 23-mm plate. We inserted the screws nicely above and below. We tightened down the lock-nuts. We irrigated the wound. We assured hemostasis using bone wax prior to placing the plate. We then assured hemostasis once again. We reapproximated the platysma using 3-0 Vicryl in a simple interrupted fashion. The subcutaneous level was closed using 3-0 Vicryl in a simple buried fashion. The skin was closed with 3-0 Monocryl in a running subcuticular stitch. Steri-Strips were applied. Dry sterile dressing with Telfa was applied over this. We obtained an intraoperative x-ray to confirm the proper level and good position of both plates and screw construct on the lateral x-ray and the patient was transferred to the recovery room, moving all four extremities with stable vital signs. I was present as a primary surgeon throughout the entire case. | surgery, allograft fusion, anterior cervical discectomy, neck pain, cervical spine, discectomy, fusion, sternocleidomastoid muscle, assured hemostasis, anterior cervical, cervical discectomy, disc space, cervical, anterior, allograft |
1,239 | Anterior cervical discectomy and osteophytectomy. Application of prosthetic interbody fusion device. Anterior cervical interbody arthrodesis. Anterior cervical instrumentation | Surgery | Anterior Cervical Discectomy & Osteophytectomy | PREOPERATIVE DIAGNOSES,1. Cervical radiculopathy, C5-C6 and C6-C7.,2. Symptomatic cervical spondylosis, C5-C6 and C6-C7.,3. Symptomatic cervical stenosis, C5-C6 and C6-C7.,4. Symptomatic cervical disc herniations, C5-C6 and C6-C7.,POSTOPERATIVE DIAGNOSES,1. Cervical radiculopathy, C5-C6 and C6-C7.,2. Symptomatic cervical spondylosis, C5-C6 and C6-C7.,3. Symptomatic cervical stenosis, C5-C6 and C6-C7.,4. Symptomatic cervical disc herniations, C5-C6 and C6-C7.,OPERATIVE PROCEDURE,1. CPT code 63075: Anterior cervical discectomy and osteophytectomy, C5-C6.,2. CPT code 63076: Anterior cervical discectomy and osteophytectomy, C6-C7, additional level.,3. CPT code 22851: Application of prosthetic interbody fusion device, C5-C6.,4. CPT code 22851-59: Application of prosthetic interbody fusion device, C6-C7, additional level.,5. CPT code 22554-51: Anterior cervical interbody arthrodesis, C5-C6.,6. CPT code 22585: Anterior cervical interbody arthrodesis, C6-C7, additional level.,7. CPT code 22845: Anterior cervical instrumentation, C5-C7.,ANESTHESIA:, General endotracheal.,ESTIMATED BLOOD LOSS: ,Negligible.,DRAINS: , Small suction drain in the cervical wound.,COMPLICATIONS:, None.,PROCEDURE IN DETAIL:, The patient was given intravenous antibiotic prophylaxis and thigh-high TED hoses were placed on the lower extremities while in the preanesthesia holding area. The patient was transported to the operative suite and on to the operative table in the supine position. General endotracheal anesthesia was induced. The head was placed on a well-padded head holder. The eyes and face were protected from pressure. A well-padded roll was placed beneath the neck and shoulders to help preserve the cervical lordosis. The arms were tucked and draped to the sides. All bony prominences were well padded. An x-ray was taken to confirm the correct level of the skin incision. The anterior neck was then prepped and draped in the usual sterile fashion.,A straight transverse skin incision over the left side of the anterior neck was made and carried down sharply through the skin and subcutaneous tissues to the level of the platysma muscle, which was divided transversely using the electrocautery. The superficial and deep layers of the deep cervical fascia were divided. The midline structures were reflected to the right side. Care was taken during the dissection to avoid injury to the recurrent laryngeal nerve and the usual anatomical location of that nerve was protected. The carotid sheath was palpated and protected laterally. An x-ray was taken to confirm the level of C5-C6 and C6-C7.,The longus colli muscle was dissected free bilaterally from C5 to C7 using blunt dissection. Hemostasis was obtained using the electrocautery. The blades of the cervical retractor were placed deep to the longus colli muscles bilaterally. At C5-C6, the anterior longitudinal ligament was divided transversely. Straight pituitary rongeurs and a curette were used to remove the contents of the disc space. All cartilages were scraped off the inferior endplate of C5 and from the superior endplate of C6. The disc resection was carried posteriorly to the posterior longitudinal ligament and laterally to the uncovertebral joints. The posterior longitudinal ligament was resected using a 1 mm Kerrison rongeur. Beginning in the midline and extending into both neural foramen, posterior osteophytes were removed using a 1 m and a 2 mm Kerrison rongeurs. The patient was noted to have significant bony spondylosis causing canal and foraminal stenosis as well as a degenerative and protruding disc in agreement with preoperative diagnostic imaging studies. Following completion of the discectomy and osteophytectomy, a blunt nerve hook was passed into the canal superiorly and inferiorly as well as in the both neural foramen to make sure that there were no extruded disc fragments and to make sure the bony decompression was complete. A portion of the uncovertebral joint was resected bilaterally for additional nerve root decompression. Both nerve roots were visualized and noted to be free of encroachment. The same procedure was then carried out at C6-C7 with similar findings. The only difference in the findings was that at C6-C7 on the left side, the patient was found to have an extruded disc fragment in the canal and extending into the left side neural foramen causing significant cord and nerve root encroachment.,In preparation for the arthrodesis, the endplates of C5, C6, and C7 were burred in a parallel fashion down to the level of bleeding bone using a high-speed cutting bur with irrigant solution for cooling. The disc spaces were then measured to the nearest millimeter. Attention was then turned toward preparation of the structural allograft, which consisted of two pieces of pre-machined corticocancellous bone. The grafts were further shaped to fit the disc spaces exactly in a press-fit manner with approximately 1.5 mm of distraction at each disc space. The grafts were shaped to be slightly lordotic to help preserve the cervical lordosis. The grafts were impacted into the disc spaces. There was complete bony apposition between the ends of the bone grafts and the vertebral bodies of C5, C6, and C7. A blunt nerve hook was passed posterior to each bone graft to make sure that the bone grafts were in good position. Anterior osteophytes were removed using a high-speed cutting bur with irrigant solution for cooling. An appropriate length Synthes cervical plate was selected and bent slightly to conform to the patient's cervical lordosis. The plate was held in the midline with provided instrumentation while a temporary fixation screw was applied at C6. Screw holes were then drilled using the provided drill and drill guide taking care to avoid injury to neurovascular structures. The plate was then rigidly fixed to the anterior spine using 14-mm cancellous screws followed by locking setscrews added to the head of each screw to prevent postoperative loosening of the plate and/or screws.,An x-ray was taken, which confirmed satisfactory postioning of the plate, screws, and bone grafts.,Blood loss was minimal. The wound was irrigated with irrigant solution containing antibiotics. The wound was inspected and judged to be dry. The wound was closed over a suction drain placed in the deepest portion of the wound by reapproximating the platysma muscle with #4-0 Vicryl running suture, the subdermal and subcuticular layers with #4-0 Monocryl interrupted sutures, and the skin with Steri-Strips. The sponge and needle count were correct. A sterile dressing was applied to the wound. The neck was placed in a cervical orthosis. The patient tolerated the procedure and was transferred to the recovery room in stable condition. | null |
1,240 | Anterior cervical discectomy with decompression, C5-C6, arthrodesis with anterior interbody fusion, C5-C6, spinal instrumentation, C5-C6 using Pioneer 18-mm plate and four 14 x 4.0 mm screws (all titanium), implant using PEEK 7 mm, and Allograft using Vitoss. | Surgery | Anterior Cervical Discectomy & Interbody Fusion | PREOPERATIVE DIAGNOSES,1. Neck pain with bilateral upper extremity radiculopathy, left more than the right.,2. Cervical spondylosis with herniated nucleus pulposus, C5-C6.,POSTOPERATIVE DIAGNOSES,1. Neck pain with bilateral upper extremity radiculopathy, left more than the right.,2. Cervical spondylosis with herniated nucleus pulposus, C5-C6.,OPERATIVE PROCEDURES,1. Anterior cervical discectomy with decompression, C5-C6.,2. Arthrodesis with anterior interbody fusion, C5-C6.,3. Spinal instrumentation, C5-C6 using Pioneer 18-mm plate and four 14 x 4.0 mm screws (all titanium).,4. Implant using PEEK 7 mm.,5. Allograft using Vitoss.,DRAINS: , Round French 10 JP drain.,FLUIDS: ,1200 cc of crystalloids.,URINE OUTPUT: , No Foley catheter.,SPECIMENS: , None.,COMPLICATIONS: , None.,ANESTHESIA: , General endotracheal anesthesia.,ESTIMATED BLOOD LOSS: , Less than 50 cc.,INDICATIONS FOR THE OPERATION:, This is a case of a very pleasant 38-year-old Caucasian female who has been complaining over the last eight years of neck pain and shoulder pain radiating down across the top of her left shoulder and also across her shoulder blades to the right side, but predominantly down the left upper extremity into the wrist. The patient has been diagnosed with fibromyalgia and subsequently, has been treated with pain medications, anti-inflammatories and muscle relaxants. The patient's symptoms continued to persist and subsequently, an MRI of the C-spine was done, which showed disc desiccation, spondylosis and herniated disk at C5-C6, an EMG and CV revealed a presence of mild-to-moderate carpal tunnel syndrome. The patient is now being recommended to undergo decompression and spinal instrumentation and fusion at C5-C6. The patient understood the risks and benefits of the surgery. Risks include but not exclusive of bleeding and infection. Bleeding can be in the form of soft tissue bleeding, which may compromise airway for which she can be brought emergently back to the operating room for emergent evacuation of the hematoma as this may cause weakness of all four extremities, numbness of all four extremities, as well as impairment of bowel and bladder function. This could also result in dural tear with its attendant symptoms of headache, nausea, vomiting, photophobia, and posterior neck pain as well as the development of pseudomeningocele. Should the symptoms be severe or the pseudomeningocele be large, she can be brought back to the operating room for repair of the CSF leak and evacuation of the pseudomeningocele. There is also the risk of pseudoarthrosis and nonfusion, for which she may require redo surgery at this level. There is also the possibility of nonimprovement of her symptoms in about 10% of cases. The patient understands this risk on top of the potential injury to the esophagus and trachea as well as the carotid artery. There is also the risk of stroke, should an undiagnosed plaque be propelled into the right cerebral circulation. The patient also understands that there could be hoarseness of the voice secondary to injury to the recurrent laryngeal nerve. She understood these risks on top of the risks of anesthesia and gave her consent for the procedure.,DESCRIPTION OF PROCEDURE: ,The patient was brought to the operating room, awake, alert and not in any form of distress. After smooth induction and intubation, the patient was positioned supine on the operating table with the neck placed on hyperextension and the head supported on a foam doughnut. A marker was placed. This verified the level to be at the C5-C6 level and incision was then marked in a transverse fashion starting from the midline extending about 5 mm beyond the anterior border of the sternocleidomastoid muscle. The area was then prepped with DuraPrep after the head was turned 45 degrees to the left.,After sterile drapes were laid out, an incision was made using a scalpel blade #10. Wound edge bleeders were carefully controlled with bipolar coagulation and the platysma was cut using a hot knife in a transverse fashion. Dissection was then carried underneath the platysma superiorly inferiorly. The anterior border of the sternocleidomastoid was identified and dissection was carried out lateral to the esophagus to trachea as well as medial to the carotid sheath in the sternocleidomastoid muscle. The prevertebral fascia was noted to be taken her case with a lot of fat deposition. Bipolar coagulation of bleeders was done; however, branch of the superior thyroid artery was ligated with Hemoclips x4. After this was completed, a localizing x-ray verified the marker to be at the C6-C7 level. We proceeded to strip the longus colli muscles off the vertebral body of the C5 and C6. Self-retaining retractor was then laid down. An anterior osteophyte was carefully drilled using a Midas 5-mm bur and the disk together with the inferior endplate of C5 and the superior endplate of C6 was also drilled down with the Midas 5-mm bur. This was later followed with a 3-mm bur and the disk together with posterior longitudinal ligament was removed using Kerrison's ranging from 1 to 4 mm. The herniation was noted on the right. However, there was significant neuroforaminal stenosis on the left. Decompression on both sides was done and after this was completed, a Valsalva maneuver showed no evidence of any CSF leakage. The area was then irrigated with saline with bacitracin solution. A 7 mm implant with its inferior packed with Vitoss was then laid down and secured in place with four 14 x 4.0 mm screws and plate 18 mm, all of which were titanium. X-ray after this placement showed excellent position of all these implants and screws and _____ and the patient's area was also irrigated with saline with bacitracin solution. A round French 10 JP drain was then laid down and exteriorized through a separate stab incision on the patient's right inferiorly. The catheter was then anchored to the skin with a nylon 3-0 stitch and connected to a sterile draining system. The wound was then closed in layers with Vicryl 3-0 inverted interrupted sutures for the platysma, Vicryl subcuticular 4-0 Stitch for the dermis, and the wound was reinforced with Dermabond. Dressing was placed only at the exit site of the catheter. C-collar was placed. The patient was extubated and transferred to recovery. | null |
1,241 | C4-C5, C5-C6 anterior cervical discectomy and fusion. The patient is a 62-year-old female who presents with neck pain as well as upper extremity symptoms. Her MRI showed stenosis at portion of C4 to C6. | Surgery | Anterior Cervical Discectomy & Fusion - 7 | PREOPERATIVE DIAGNOSIS:, C4-C5, C5-C6 stenosis.,PREOPERATIVE DIAGNOSIS: , C4-C5, C5-C6 stenosis.,PROCEDURE: , C4-C5, C5-C6 anterior cervical discectomy and fusion.,COMPLICATIONS: , None.,ANESTHESIA: , General.,INDICATIONS OF PROCEDURE: , The patient is a 62-year-old female who presents with neck pain as well as upper extremity symptoms. Her MRI showed stenosis at portion of C4 to C6. I discussed the procedure as well as risks and complications. She wishes to proceed with surgery. Risks will include but are not limited to infection, hemorrhage, spinal fluid leak, worsened neurologic deficit, recurrent stenosis, requiring further surgery, difficulty with fusion requiring further surgery, long-term hoarseness of voice, difficulty swallowing, medical anesthesia risk.,PROCEDURE: ,The patient was taken to the operating room on 10/02/2007. She was intubated for anesthesia. TEDS and boots as well as Foley catheter were placed. She was placed in a supine position with her neck in neutral position. Appropriate pads were also used. The area was prepped and draped in usual sterile fashion. Preoperative localization was taken. _____ not changed. Incision was made on the right side in transverse fashion over C5 vertebral body level. This was made with a #10 blade knife and further taken down with pickups and scissors. The plane between the esophagus and carotid artery was carefully dissected both bluntly and sharply down to the anterior aspect of the cervical spine. Intraoperative x-ray was taken. Longus colli muscles were retracted laterally. Caspar retractors were used. Intraoperative x-ray was taken. I first turned by attention at C5-C6 interspace. This was opened with #15 blade knife. Disc material was taken out using pituitary as well as Kerrison rongeur. Anterior aspects were taken down. End plates were arthrodesed using curettes. This was done under distraction. Posterior longitudinal ligament was opened with a nerve hook and Kerrison rongeur. Bilateral foraminotomies were done. At this point, I felt that there was a good decompression. The foramen appeared to be opened. Medtronic cage was then encountered and sent few millimeters. This was packed with demineralized bone matrix. The distraction was then taken down. The cage appeared to be strong. This procedure was then repeated at C4-C5. A 42-mm AcuFix plate was then placed between C4 and C6. This was carefully screwed and locked. The instrumentation appeared to be strong. Intraoperative x-ray was taken. Irrigation was used. Hemostasis was achieved. The platysmas was closed with 3-0 Vicryl stitches. The subcutaneous was closed with 4-0 Vicryl stitches. The skin was closed with Steri-strips. The area was clean and dry and dressed with Telfa and Tegaderm. Soft cervical collar was placed for the patient. She was extubated per anesthesia and brought to the recovery in stable condition. | surgery, anterior cervical discectomy, fusion, infection, hemorrhage, spinal fluid leak, anesthesia, foley catheter, teds, anterior cervical, cervical discectomy, anterior, cervical, discectomy, stenosis, |
1,242 | Anterior cervical discectomy for neural decompression and anterior interbody fusion at C4-C5, C5-C6, and C6-C7 utilizing Bengal cages times three. | Surgery | Anterior Cervical Discectomy & Interbody Fusion - 1 | PREOPERATIVE DIAGNOSES: ,1. Herniated nucleus pulposus, C5-C6, greater than C6-C7 and C4-C5 with left radiculopathy.,2. Cervical stenosis with cord compression, C5-C6 (723.0).,POSTOPERATIVE DIAGNOSES: ,1. Herniated nucleus pulposus, C5-C6, greater than C6-C7 and C4-C5 with left radiculopathy.,2. Cervical stenosis with cord compression, C5-C6 (723.0), with surgical findings confirmed.,PROCEDURES: ,1. Anterior cervical discectomy at C4-C5, C5-C6, and C6-C7 for neural decompression (63075, 63076, 63076).,2. Anterior interbody fusion at C4-C5, C5-C6, and C6-C7 (22554, 22585, 22585) utilizing Bengal cages times three (22851).,3. Anterior instrumentation for stabilization by Slim-LOC plate C4, C5, C6, and C7 (22846); with intraoperative x-ray times two.,ANESTHESIA:, General.,SERVICE: , Neurosurgery.,OPERATION: , The patient was brought into the operating room, placed in a supine position where general anesthesia was administered. Then the anterior aspect of the neck was prepped and draped in a routine sterile fashion. A linear skin incision was made in the skin fold line from just to the right of the midline to the leading edge of the right sternocleidomastoid muscle and taken sharply to platysma, which was dissected in a subplatysmal manner, and then the prevertebral space was encountered and prominent anterior osteophytes were well visualized once longus colli muscle was cauterized along its mesial border, and self-retaining retractors were placed to reveal the anterior osteophytic spaces. Large osteophytes were excised with a rongeur at C4-5, C5-C6, and C6-C7 revealing a collapsed disc space and a #11 blade was utilized to create an annulotomy at all three interspaces with discectomies being performed with straight disc forceps removing grossly degenerated and very degenerated discs at C4-C5, then at C5-C6, then at C6-C7 sending specimen for permanent section to Pathology in a routine and separate manner. Residual disc fragments were drilled away as drilling extended into normal cortical and cancellous elements in order to perform a wide decompression all the way posteriorly to the spinal canal itself finally revealing a ligament, which was removed in a similar piecemeal fashion with 1 and 2-mm micro Kerrison rongeurs also utilizing these instruments to remove prominent osteophytes, widely laterally bilaterally at each interspace with one at C4-C5, more right-sided. The most prominent osteophyte and compression was at C5-C6 followed by C6-C7 and C4-C5 with a complete decompression of the spinal canal allowing the dura to finally bulge into the interspace at all three levels, once the ligaments were proximally removed as well and similarly a sign of a decompressed status. The nerve roots themselves were inspected with a double ball dissector and found to be equally decompressed. The wound was irrigated with antibiotic solution and hemostasis was well achieved with pledgets of Gelfoam subsequently irrigated away. Appropriate size Bengal cages were filled with the patient's own bone elements and countersunk into position, filled along with fusion putty, and once these were quite tightly applied and checked, further stability was added by the placement of a Slim-LOC plate of appropriate size with appropriate size screws, and a post placement x-ray showed well-aligned elements.,The wound was irrigated with antibiotic solution again and inspected, and hemostasis was completely achieved and finally the wound was closed in a routine closure by approximation of the platysma with interrupted 3-0 Vicryl, and the skin with a subcuticular stitch of 4-0 Vicryl, and this was sterilely dressed, and incorporated a Penrose drain, which was carried from the prevertebral space externally to the skin wound and safety pin for security in a routine fashion. At the conclusion of the case, all instruments, needle, and sponge counts were accurate and correct, and there were no intraoperative complications of any type. | surgery, herniated nucleus pulposus, radiculopathy, cervical stenosis, anterior instrumentation, stabilization, slim-loc, neural decompression, anterior cervical discectomy, cord compression, interbody fusion, bengal cages, interbody, compression, anterior, fusion, decompression, discectomy, cervical |
1,243 | Herniated nucleus pulposus C5-C6. Anterior cervical discectomy fusion C5-C6 followed by instrumentation C5-C6 with titanium dynamic plating system, Aesculap. Operating microscope was used for both illumination and magnification. | Surgery | Anterior Cervical Discectomy & Fusion - 9 | PREOPERATIVE DIAGNOSIS: , Herniated nucleus pulposus C5-C6.,POSTOPERATIVE DIAGNOSIS: , Herniated nucleus pulposus C5-C6.,PROCEDURE:, Anterior cervical discectomy fusion C5-C6 followed by instrumentation C5-C6 with titanium dynamic plating system, Aesculap. Operating microscope was used for both illumination and magnification.,FIRST ASSISTANT: , Nurse practitioner.,PROCEDURE IN DETAIL: , The patient was placed in supine position. The neck was prepped and draped in the usual fashion for anterior discectomy and fusion. An incision was made midline to the anterior body of the sternocleidomastoid at C5-C6 level. The skin, subcutaneous tissue, and platysma muscle was divided exposing the carotid sheath, which was retracted laterally. Trachea and esophagus were retracted medially. After placing the self-retaining retractors with the longus colli muscles having been dissected away from the vertebral bodies at C5 and C6 and confirming our position with intraoperative x-rays, we then proceeded with the discectomy.,We then cleaned out the disc at C5-C6 after incising the annulus fibrosis. We cleaned out the disc with a combination of angled and straight pituitary rongeurs and curettes, and the next step was to clean out the disc space totally. With this having been done, we then turned our attention with the operating microscope to the osteophytes. We drilled off the vertebral osteophytes at C5-C6, as well as the uncovertebral osteophytes. This was removed along with the posterior longitudinal ligament. After we had done this, the dural sac was opposed very nicely and both C6 nerve roots were thoroughly decompressed. The next step after the decompression of the thecal sac and both C6 nerve roots was the fusion. We observed that there was a ____________ in the posterior longitudinal ligament. There was a free fragment disc, which had broken through the posterior longitudinal ligament just to the right of midline.,The next step was to obtain the bone from the back bone, using cortical cancellous graft 10 mm in size after we had estimated the size. That was secured into place with distraction being applied on the vertebral bodies using vertebral body distractor.,After we had tapped in the bone plug, we then removed the distraction and the bone plug was fitting nicely.,We then use the Aesculap cervical titanium instrumentation with the 16-mm screws. After securing the C5-C6 disc with four screws and titanium plate, x-rays showed good alignment of the spine, good placement of the bone graft, and after x-rays showed excellent position of the bone graft and instrumentation, we then placed in a Jackson-Pratt drain in the prevertebral space brought out through a separate incision. The wound was closed with 2-0 Vicryl for subcutaneous tissues and skin was closed with Steri-Strips. Blood loss during the operation was less than 10 mL. No complications of the surgery. Needle count, sponge count, and cottonoid count were correct., | surgery, aesculap, titanium dynamic plating system, anterior cervical discectomy, herniated nucleus pulposus, cervical discectomy, operating microscope, longitudinal ligament, discectomy, anterior, instrumentation, cervical, titanium |
1,244 | Anterior cervical discectomy with decompression of spinal cord. Anterior cervical fusion. Anterior cervical instrumentation. Insertion of intervertebral device. Use of operating microscope. | Surgery | Anterior Cervical Discectomy & Fusion - 6 | PREOPERATIVE DIAGNOSIS: ,Symptomatic disk herniation, C7-T1.,FINAL DIAGNOSIS: ,Symptomatic disk herniation, C7-T1.,PROCEDURES PERFORMED,1. Anterior cervical discectomy with decompression of spinal cord C7-T1.,2. Anterior cervical fusion, C7-T1.,3. Anterior cervical instrumentation, anterior C7-T1.,4. Insertion of intervertebral device, C7-T1.,5. Use of operating microscope.,ANESTHESIOLOGY: , General endotracheal.,ESTIMATED BLOOD LOSS: ,A 30 mL.,PROCEDURE IN DETAIL: ,The patient was taken to the operating room where he was orally intubated by The Anesthesiology Service. He was placed in the supine position on an OR table. His arms were carefully taped down. He was sterilely prepped and draped in the usual fashion.,A 4-cm incision was made obliquely over the left side of his neck. Subcutaneous tissue was dissected down to the level of the platysma. The platysma was incised using electrocautery. Blunt dissection was done to create a plane between the strap muscles and the sternoclavicular mastoid muscle. This allowed us to get right down on to the anterior cervical spine. Blunt dissection was done to sweep off the longus colli. We isolated the C7-T1 interspace. An x-ray was taken to verify; we were indeed at the C7-T1 interspace.,Shadow-Line retractor was placed as well as Caspar pins. This provided very, very good access to the C7-T1 disk.,At this point, the operating microscope was brought into the decompression.,A thorough and aggressive C7-T1 discectomy was done using a succession of curettes, pituitary rongeur, 4-mm cutting bur and a #2 Kerrison rongeur. At the end of the discectomy, the cartilaginous endplates were carefully removed using 4-mm cutting burr. The posterior longitudinal ligament was carefully resected using #2 Kerrison rongeur. Left-sided C8 foraminotomy was accomplished using nerve hook and a 2-mm Kerrison rongeur. At the end of the decompression, there was no further compression on the left C8 nerve root.,A Synthes cortical cancellous ____________ bone was placed in the interspace. Sofamor Danek Atlantis plate was then placed over the interspace and four screws were placed, two in the body of C7 and two in the body of T1. An x-ray was taken. It showed good placement of the plate and screws.,A deep drain was placed. The platysma layer was closed in running fashion using #1 Vicryl. Subcutaneous tissue was closed in an interrupted fashion using 2-0 Vicryl. Skin was closed in a running fashion using 4-0 Monocryl. Steri-Strips and dressings were applied. All counts were correct. There were no complications. | surgery, disk herniation, cervical discectomy, decompression, spinal cord, anterior cervical fusion, anterior cervical discectomy, kerrison rongeur, anterior cervical, instrumentation, cervical, anterior, platysma, kerrison, fashion, interspace, rongeur, discectomy, herniation, |
1,245 | Anterior cervical discectomy fusion C3-C4 and C4-C5 using operating microscope and the ABC titanium plates fixation with bone black bone procedure. Cervical spondylotic myelopathy with cord compression and cervical spondylosis. | Surgery | Anterior Cervical Discectomy & Fusion | PREOPERATIVE DIAGNOSES:, Cervical spondylotic myelopathy with cord compression and cervical spondylosis.,POSTOPERATIVE DIAGNOSES:, Cervical spondylotic myelopathy with cord compression and cervical spondylosis. In addition to this, he had a large herniated disk at C3-C4 in the midline.,PROCEDURE: , Anterior cervical discectomy fusion C3-C4 and C4-C5 using operating microscope and the ABC titanium plates fixation with bone black bone procedure.,PROCEDURE IN DETAIL: , The patient placed in the supine position, the neck was prepped and draped in the usual fashion. Incision was made in the midline the anterior border of the sternocleidomastoid at the level of C4. Skin, subcutaneous tissue, and vertebral muscles divided longitudinally in the direction of the fibers and the trachea and esophagus was retracted medially. The carotid sheath was retracted laterally after dissecting the longus colli muscle away from the vertebral osteophytes we could see very large osteophytes at C4-C5. It appeared that the C5-C6 disk area had fused spontaneously. We then confirmed that position by taking intraoperative x-rays and then proceeded to do discectomy and fusion at C3-C4, C4-C5.,After placing distraction screws and self-retaining retractors with the teeth beneath the bellies of the longus colli muscles, we then meticulously removed the disk at C3-C4, C4-C5 using the combination of angled strip, pituitary rongeurs, and curettes after we had incised the anulus fibrosus with #15 blade.,Next step was to totally decompress the spinal cord using the operating microscope and high-speed cutting followed by the diamond drill with constant irrigation. We then drilled off the uncovertebral osteophytes and midline osteophytes as well as thinning out the posterior longitudinal ligaments. This was then removed with 2-mm Kerrison rongeur. After we removed the posterior longitudinal ligament, we could see the dura pulsating nicely. We did foraminotomies at C3-C4 as well as C4-C5 as well. After having totally decompressed both the cord as well as the nerve roots of C3-C4, C4-C5, we proceeded to the next step, which was a fusion.,We sized two 8-mm cortical cancellous grafts and after distracting the bone at C3-C4, C4-C5, we gently tapped the grafts into place. The distraction was removed and the grafts were now within. We went to the next step for the procedure, which was the instrumentation and stabilization of the fused area.,We then placed a titanium ABC plate from C3-C5, secured it with 16-mm titanium screws. X-rays showed good position of the screws end plate.,The next step was to place Jackson-Pratt drain to the vertebral fascia. Meticulous hemostasis was obtained. The wound was closed in layers using 2-0 Vicryl for the subcutaneous tissue. Steri-Strips were used for skin closure. Blood loss less than about 200 mL. No complications of the surgery. Needle counts, sponge count, and cottonoid count was correct. | surgery, titanium plates fixation, bone black bone procedure, anterior cervical discectomy, titanium plates, cervical discectomy, spondylotic myelopathy, cord compression, cervical spondylosis, foraminotomies, cervical, anterior |
1,246 | Anterior cervical discectomy at C5-C6 and C6-C7 for neural decompression and anterior interbody fusion at C5-C6 and C6-C7 utilizing Bengal cages x2. Anterior instrumentation by Uniplate construction C5, C6, and C7 with intraoperative x-ray x2. | Surgery | Anterior Cervical Discectomy & Fusion - 5 | PREOPERATIVE DIAGNOSES: ,1. Cervical spondylosis C5-C6 greater than C6-C7 (721.0).,2. Neck pain, progressive (723.1) with right greater than left radiculopathy (723.4).,POSTOPERATIVE DIAGNOSES: ,1. Cervical spondylosis C5-C6 greater than C6-C7 (721.0).,2. Neck pain, progressive (723.1) with right greater than left radiculopathy (723.4), surgical findings confirmed.,PROCEDURES: ,1. Anterior cervical discectomy at C5-C6 and C6-C7 for neural decompression (63075, 63076).,2. Anterior interbody fusion at C5-C6 and C6-C7 (22554, 22585) utilizing Bengal cages x2 (22851).,3. Anterior instrumentation by Uniplate construction C5, C6, and C7 (22845); with intraoperative x-ray x2.,ANESTHESIA: ,General.,OPERATIONS: , The patient was brought to the operating room and placed in the supine position where general anesthesia was administered. Then the anterior aspect of the neck was prepped and draped in the routine sterile fashion. A linear skin incision was made in the skin fold line from just to the right of the midline to the leading edge of the right sternocleidomastoid muscle and taken sharply to platysma, which was dissected in a subplatysmal manner and then with only blunt dissection, the prevertebral space was encountered and localizing intraoperative x-ray was obtained once cauterized the longus colli muscle bilaterally allowed for the placement along its mesial portion of self-retaining retractors for exposure of tissues. Prominent anterior osteophytes once identified and compared to preoperative studies were removed at C5-C6 and then at C6-C7 with rongeur, allowing for an annulotomy with an #11 blade through collapsed disc space at C5-6, and even more collapsed at C6-C7. Gross instability appeared and though minimally at both interspaces and residual disc were removed then with the straight disc forceps providing a discectomy at both levels, sending to Pathology in a routine fashion as disc specimen. This was sent separately and allowed for residual disc removal of power drill where drilling extended in normal cortical and cancellous elements of the C5 and C6 interspaces and at C6-C7 removing large osteophytes and process, residual osteophytes from which were removed finally with 1 and 2 mm micro Kerrison rongeurs allowing for excision of other hypertrophied ligament posteriorly as well. This allowed for the bulging into the interspace of the dura, sign of decompressed status, and this was done widely bilaterally to decompress the nerve roots themselves and this was assured by inspection with a double ball dissector as needed. At no time during the case was there evidence of CSF leakage and hemostasis was well achieved with pledgets of Gelfoam and subsequently removed with copious amounts of antibiotic irrigation as well as Surgifoam. Once hemostasis well achieved, Bengal cage was filled with the patient's own bone elements of appropriate size, and this was countersunk into position and quite tightly applied it at first C5-C6, then secondly at C6-C7. These were checked and found to be well applied and further stability was then added by placement nonetheless of a Uniplate of appropriate size. The appropriate size screws and post-placement x-ray showed well-aligned elements and removal of osteophytes, etc. The wound was again irrigated with antibiotic solution, inspected, and finally closed in a multiple layered closure by approximation of platysma with interrupted #3-0 Vicryl and the skin with subcuticular stitch of #4-0 Vicryl incorporating a Penrose drain from vertebral space externally through the skin wound and safety pin, and later incorporated itself into sterile bandage.,Once the bandage was placed, the patient was taken, extubated from the operating room to the Recovery area, having in stable, but guarded condition. At the conclusion of the case, all instrument, needle, and sponge counts were accurate and correct. There were no intraoperative complications of any type. | surgery, cervical spondylosis, anterior cervical discectomy, anterior instrumentation, annulotomy, kerrison rongeurs, surgifoam, vertebral space, uniplate construction, bengal cages, neural decompression, anterior cervical, cervical discectomy, interbody, anterior, cervical, discectomy |
1,247 | Anterior cervical discectomy with decompression and arthrodesis with anterior interbody fusion. Spinal instrumentation using Pioneer 18-mm plate and four 14 x 4.3 mm screws (all titanium). | Surgery | Anterior Cervical Discectomy & Fusion - 4 | PREOPERATIVE DIAGNOSIS: , Cervical myelopathy, C3-4, secondary to stenosis from herniated nucleus pulposus, C3-4.,POSTOPERATIVE DIAGNOSES: , Cervical myelopathy, C3-4, secondary to stenosis from herniated nucleus pulposus, C3-4.,OPERATIVE PROCEDURES,1. Anterior cervical discectomy with decompression, C3-4.,2. Arthrodesis with anterior interbody fusion, C3-4.,3. Spinal instrumentation using Pioneer 18-mm plate and four 14 x 4.3 mm screws (all titanium).,4. Implant using PEEK 7 mm.,5. Allograft using Vitoss.,DRAINS: , Round French 10 JP drain.,FLUIDS: , 1800 mL of crystalloids.,URINE OUTPUT: ,1000 mL.,SPECIMENS: , None.,COMPLICATIONS: ,None.,ANESTHESIA: , General endotracheal anesthesia.,ESTIMATED BLOOD LOSS: ,Less than 100 mL.,CONDITION: ,To postanesthesia care unit extubated with stable vital signs.,INDICATIONS FOR THE OPERATION: ,This is a case of a very pleasant 32-year-old Caucasian male who had been experiencing posterior neck discomfort and was shooting basketball last week, during which time he felt a pop. Since then, the patient started complaining of acute right arm and right leg weakness, which had been progressively worsening. About two days ago, he started noticing weakness on the left arm. The patient also noted shuffling gait. The patient presented to a family physician and was referred to Dr. X for further evaluation. Dr. X could not attempt to this, so he called me at the office and the patient was sent to the emergency room, where an MRI of the brain was essentially unremarkable as well as MRI of the thoracic spine. MRI of the cervical spine, however, revealed an acute disk herniation at C3-C4 with evidence of stenosis and cord changes. Based on these findings, I recommended decompression. The patient was started on Decadron at 10 mg IV q.6h. Operation, expected outcome, risks, and benefits were discussed with him. Risks to include but not exclusive of bleeding and infection. Bleeding can be superficial, but can compromise airway, for which he has been told that he may be brought emergently back to the operating room for evacuation of said hematoma. The hematoma could also be an epidural hematoma, which may compress the spinal cord and result in weakness of all four extremities, numbness of all four extremities, and impairment of bowel and bladder function. Should this happen, he needs to be brought emergently back to the operating room for evacuation of said hematoma. There is also the risk by removing the hematoma that he can deteriorate as far as neurological condition, but this hopefully with the steroid prep will be prevented or if present will only be transient. There is also the possibility of infection, which can be superficial and treated with IV and p.o. antibiotics. However, should the infection be extensive or be deep, he may require return to the operating room for debridement and irrigation. This may pose a medical problem since in the presence of infection, the graft as well as spinal instrumentation may have to be removed. There is also the possibility of dural tear with its attendant complaints of headache, nausea, vomiting, photophobia, as well as the development of pseudomeningocele. This too can compromise airway and may require return to the operating room for repair of the dural tear. There is also potential risk of injury to the esophagus, the trachea, as well as the carotid. The patient can also have a stroke on the right cerebral circulation should the plaque be propelled into the right circulation. The patient understood all these risks together with the risk associated with anesthesia and agreed to have the procedure performed.,DESCRIPTION OF PROCEDURE: ,The patient was brought to the operating room, awake, alert and not in any form of distress. After smooth induction and intubation, a Foley catheter was inserted. No monitoring leads were placed. The patient was then positioned supine on the operating table with the head supported on a foam doughnut and the neck placed on hyperextension with a shoulder roll under both shoulders. Localizing x-ray verified the marker to be right at the C3-4 interspace. Proceeded to mark an incision along the anterior border of the sternocleidomastoid with the central point at the area of the marker measuring about 3 cm in length. The area was then prepped with DuraPrep.,After sterile drapes were laid out, an incision was made using a scalpel blade #10. Wound edge bleeders were controlled with bipolar coagulation and a hot knife was utilized to cut the platysma in a similar fashion. The anterior border of the sternocleidomastoid was identified and dissection was carried superior to and lateral to the esophagus and trachea, but medial to the carotid sheath. The prevertebral fascia was identified. Localizing x-ray verified another marker to be at the C3-4 interspace. Proceeded to strip the longus colli muscles off the vertebral body of C3 and C4 and a self-retaining retractor was then laid out. There was some degree of anterior osteophyte and this was carefully drilled down with a Midas 5-mm bur. The disk was then cut through the annulus and removal of the disk was done with the use of the Midas 5-mm bur and later a 3-mm bur. The inferior endplate of C3 and the superior endplate of C4 were likewise drilled out together with posterior inferior osteophyte at the C3 and the posterior superior osteophyte at C4. There was note of a central disk herniation centrally, but more marked displacement of the cord on the left side. By careful dissection of this disk, posterior longitudinal ligament was removed and pressure on the cord was removed. Hemostasis of the epidural bleeders was done with a combination of bipolar coagulation, but we needed to put a small piece of Gelfoam on the patient's left because of profuse venous bleeder. With this completed, the Valsalva maneuver showed no evidence of any CSF leakage. A 7-mm implant with its interior packed with Vitoss was then tapped into place. An 18-mm plate was then screwed down with four 14 x 4.0 mm screws. The area was irrigated with saline, with bacitracin solution. Postoperative x-ray showed excellent placement of the graft and spinal instrumentation. A round French 10 JP drain was laid over the construct and exteriorized though a separate stab incision on the patient's right inferiorly. The wound was then closed in layers with Vicryl 3-0 inverted interrupted sutures for the platysma, Vicryl 4-0 subcuticular stitch for the dermis and Dermabond. The catheter was anchored to the skin with a nylon 3-0 stitch. Dressing was placed only on the exit site of the drain. C-collar was placed, and the patient was transferred to the recovery awake and moving all four extremities. | null |
1,248 | Radical anterior discectomy with removal of posterior osteophytes, foraminotomies, and decompression of the spinal canal. Anterior cervical fusion. Utilization of allograft for purposes of spinal fusion. Application of anterior cervical locking plate. | Surgery | Anterior Cervical Discectomy & Fusion - 3 | PREOPERATIVE DIAGNOSES,1. Cervical spinal stenosis, C3-c4 and C4-C5.,2. Cervical spondylotic myelopathy.,POSTOPERATIVE DIAGNOSES,1. Cervical spinal stenosis, C3-C4 and C4-C5.,2. Cervical spondylotic myelopathy.,OPERATIVE PROCEDURES,1. Radical anterior discectomy, C3-C4 with removal of posterior osteophytes, foraminotomies, and decompression of the spinal canal (CPT 63075).,2. Radical anterior discectomy C4-C5 with removal of posterior osteophytes, foraminotomies, and decompression of the spinal canal (CPT 63076).,3. Anterior cervical fusion, C3-C4 (CPT 22554),4. Anterior cervical fusion, C4-C5 (CPT 22585).,5. Utilization of allograft for purposes of spinal fusion (CPT 20931).,6. Application of anterior cervical locking plate C3-C5 (CPT 22845).,ANESTHESIA:, General endotracheal.,COMPLICATIONS: , None.,ESTIMATED BLOOD LOSS: ,250 cc.,OPERATIVE INDICATIONS: ,The patient is a 50-year-old gentleman who presented to the hospital after a fall, presenting with neck and arm pain as well as weakness. His MRI confirmed significant neurologic compression in the cervical spine, combined with a clinical exam consistent with radiculopathy, myelopathy, and weakness. We discussed the diagnosis and the treatment options. Due to the severity of his neurologic symptoms as well as the amount of neurologic compression seen radiographically, I recommended that he proceed with surgical intervention as opposed to standard nonsurgical treatment such as physical therapy, medications, and steroid injections. I explained the surgery itself which will be to remove pressure from the spinal cord via anterior cervical discectomy and fusion at C3-C4 and C4-C5. We reviewed the surgery itself as well as risks including infection and blood vessels or nerves, leakage of spinal fluid, weakness or paralysis, failure of the pain to improve, possible worsening of the pain, failure of the neurologic symptoms to improve, possible worsening of the neurologic symptoms, and possible need for further surgery including re-revision and/or removal. Furthermore I explained that the fusion may not become solid or that the hardware could break. We discussed various techniques available for obtaining fusion and I recommended allograft and plate fixation. I explained the rationale for this as well as the options of using his own bone. Furthermore, I explained that removing motion at the fusion sites will transfer stress to other disc levels possibly accelerating there degeneration and causing additional symptoms and/or necessitating additional surgery in the future.,OPERATIVE TECHNIQUE: , After obtaining the appropriate signed and informed consent, the patient was taken to the operating room, where he underwent general endotracheal anesthesia without complications. He was then positioned supine on the operating table, and all bony prominences were padded. Pulse oximetry was maintained on both feet throughout the case. The arms were carefully padded and tucked at his sides. A roll was placed between the shoulder blades. The areas of the both ears were sterilely prepped and cranial tongs were applied in routine fashion. Ten pounds of traction was applied. A needle was taped to the anterior neck and an x-ray was done to determine the appropriate level for the skin incision. The entire neck was then sterilely prepped and draped in the usual fashion.,A transverse skin incision was made and carried down to the platysma muscle. This was then split in line with its fibers. Blunt dissection was carried down medial to the carotid sheath and lateral to the trachea and esophagus until the anterior cervical spine was visualized. A needle was placed into a disc and an x-ray was done to determine its location. The longus colli muscles were then elevated bilaterally with the electrocautery unit. Self-retaining retractors were placed deep to the longus colli muscle in an effort to avoid injury to the sympathetic chains.,Radical anterior discectomies were performed at C3-C4 and C4-C5. This included complete removal of the anterior annulus, nucleus, and posterior annulus. The posterior longitudinal ligament was removed as were the posterior osteophytes. Foraminotomies were then accomplished bilaterally. Once all of this was accomplished, the blunt-tip probe was used to check for any residual compression. The central canal was wide open at each level as were the foramen.,A high-speed bur was used to remove the cartilaginous endplates above and below each interspace. Bleeding cancellous bone was exposed. The disc spaces were measured and appropriate size allografts were placed sterilely onto the field. After further shaping of the grafts with the high-speed bur, they were carefully impacted in to position. There was good juxtaposition against the bleeding decorticated surfaces and good distraction of each interspace. All weight was then removed from the crania tongs.,The appropriate size anterior cervical locking plate was chosen and bent into gentle lordosis. Two screws were then placed into each of the vertebral bodies at C3, C4, and C5. There was excellent purchase. A final x-ray was done confirming good position of the hardware and grafts. The locking screws were then applied, also with excellent purchase.,Following a final copious irrigation, there was good hemostasis and no dural leaks. The carotid pulse was strong. A drain was placed deep to the level of the platysma muscle and left at the level of the hardware. The wounds were then closed in layers using 4-0 Vicryl suture for the platysma muscle, 4-0 Vicryl suture for the subcutaneous tissue, and 4-0 Vicryl suture in a subcuticular skin closure. Steri-Strips were placed followed by application of a sterile dressing. The drain was hooked to bulb suction. A Philadelphia collar was applied.,The cranial tongs were carefully removed. The soft tissue overlying the puncture site was massaged to free it up from the underlying bone. There was good hemostasis.,The patient was then carefully returned to the supine position on his hospital bed where he was reversed and extubated and taken to the recovery room having tolerated the procedure well. | null |
1,249 | Herniated nucleus pulposus, C5-C6, with spinal stenosis. Anterior cervical discectomy with fusion C5-C6. | Surgery | Anterior Cervical Discectomy & Fusion - 2 | PREOPERATIVE DIAGNOSIS: , Herniated nucleus pulposus, C5-C6, with spinal stenosis.,POSTOPERATIVE DIAGNOSIS: , Herniated nucleus pulposus, C5-C6, with spinal stenosis.,PROCEDURE: , Anterior cervical discectomy with fusion C5-C6.,PROCEDURE IN DETAIL: , The patient was placed in supine position. The neck was prepped and draped in the usual fashion. An incision was made from midline to the anterior border of the sternocleidomastoid in the right side. Skin and subcutaneous tissue were divided sharply. Trachea and esophagus were retracted medially. Carotid sheath was retracted laterally. Longus colli muscles were dissected away from the vertebral bodies of C5-C6. We confirmed our position by taking intraoperative x-rays. We then used the operating microscope and cleaned out the disk completely. We then sized the interspace and then tapped in a #7 mm cortical cancellous graft. We then used the DePuy Dynamic plate with 14-mm screws. Jackson-Pratt drain was placed in the prevertebral space and brought out through a separate incision. The wound was closed in layers using 2-0 Vicryl for muscle and fascia. The blood loss was less than 10-20 mL. No complication. Needle count, sponge count, and cottonoid count was correct. | surgery, carotid sheath, jackson-pratt drain, anterior cervical discectomy, herniated nucleus pulposus, cervical discectomy, herniated nucleus, nucleus pulposus, spinal stenosis, discectomy, fusion, herniated, nucleus, pulposus, spinal, stenosis, anterior |
1,250 | Anterior cervical discectomy with decompression C6-C7, arthrodesis with anterior interbody fusion C6-C7, spinal instrumentation using Pioneer 20 mm plate and four 12 x 4.0 mm screws, PEEK implant 7 mm, and Allograft using Vitoss. | Surgery | Anterior Cervical Discectomy & Decompression | PREOPERATIVE DIAGNOSES,1. Left neck pain with left upper extremity radiculopathy.,2. Left C6-C7 neuroforaminal stenosis secondary to osteophyte.,POSTOPERATIVE DIAGNOSES,1. Left neck pain with left upper extremity radiculopathy.,2. Left C6-C7 neuroforaminal stenosis secondary to osteophyte.,OPERATIVE PROCEDURE,1. Anterior cervical discectomy with decompression C6-C7.,2. Arthrodesis with anterior interbody fusion C6-C7.,3. Spinal instrumentation using Pioneer 20 mm plate and four 12 x 4.0 mm screws.,4. PEEK implant 7 mm.,5. Allograft using Vitoss.,ANESTHESIA: , General endotracheal anesthesia.,FINDINGS: , Showed osteophyte with a disc complex on the left C6-C7 neural foramen.,FLUIDS: ,1800 mL of crystalloids.,URINE OUTPUT: , No Foley catheter.,DRAINS: ,Round French 10 JP drain.,SPECIMENS,: None.,COMPLICATIONS: , None.,ESTIMATED BLOOD LOSS:, 250 mL.,The need for an assistant is important in this case, since her absence would mean prolonged operative time and may increase operative morbidity and mortality.,CONDITION: , Extubated with stable vital signs.,INDICATIONS FOR THE OPERATION:, This is the case of a very pleasant 46-year-old Caucasian female with subarachnoid hemorrhage secondary to ruptured left posteroinferior cerebellar artery aneurysm, which was clipped. The patient last underwent a right frontal ventricular peritoneal shunt on 10/12/07. This resulted in relief of left chest pain, but the patient continued to complaint of persistent pain to the left shoulder and left elbow. She was seen in clinic on 12/11/07 during which time MRI of the left shoulder showed no evidence of rotator cuff tear. She did have a previous MRI of the cervical spine that did show an osteophyte on the left C6-C7 level. Based on this, negative MRI of the shoulder, the patient was recommended to have anterior cervical discectomy with anterior interbody fusion at C6-C7 level. Operation, expected outcome, risks, and benefits were discussed with her. Risks include, but not exclusive of bleeding and infection, bleeding could be soft tissue bleeding, which may compromise airway and may result in return to the operating room emergently for evacuation of said hematoma. There is also the possibility of bleeding into the epidural space, which can compress the spinal cord and result in weakness and numbness of all four extremities as well as impairment of bowel and bladder function. Should this occur, the patient understands that she needs to be brought emergently back to the operating room for evacuation of said hematoma. There is also the risk of infection, which can be superficial and can be managed with p.o. antibiotics. However, the patient may develop deeper-seated infection, which may require return to the operating room. Should the infection be in the area of the spinal instrumentation, this will cause a dilemma since there might be a need to remove the spinal instrumentation and/or allograft. There is also the possibility of potential injury to the esophageus, the trachea, and the carotid artery. There is also the risks of stroke on the right cerebral circulation should an undiagnosed plaque be propelled from the right carotid. There is also the possibility hoarseness of the voice secondary to injury to the recurrent laryngeal nerve. There is also the risk of pseudoarthrosis and hardware failure. She understood all of these risks and agreed to have the procedure performed.,DESCRIPTION OF PROCEDURE: , The patient brought to the operating room, awake, alert, not in any form of distress. After smooth induction and intubation, a Foley catheter was inserted. Monitoring leads were placed by Premier Neurodiagnostics and this revealed normal findings, which remained normal during the entire case. The EMGs were silent and there was no evidence of any stimulation. After completion of the placement of the monitoring leads, the patient was positioned supine on the operating table with the neck placed on hyperextension. The head was supported on a foam doughnut. The right cervical area was then exposed by turning the head about 45 to 60 degrees to the left side. A linear incision was made about two to three fingerbreadths from the suprasternal notch along the anterior border of the sternocleidomastoid muscle to a distance of about 3 cm. The area was then prepped with DuraPrep.,After sterile drapes were laid out, the incision was made using a scalpel blade #10. Wound edge bleeders were controlled with bipolar coagulation and a hot knife was utilized to carry the dissection down to the platysma in the similar fashion as the skin incision. The anterior border of the sternocleidomastoid muscle was identified as well as the sternohyoid/omohyoid muscles. Dissection was then carried lateral and superior to the omohyoid muscle and lateral to the esophagus and the trachea, and medial to the sternocleidomastoid muscle and the carotid sheath. The prevertebral fascia was identified and cut sharply. A localizing x-ray verified the marker to be at the C6-C7 interspace. Proceeded to the strip the longus colli muscles off the vertebral body of C6 and C7. Self-retaining retractor was then laid out. The annulus was then cut in a quadrangular fashion and piecemeal removal of the dura was done using a straight pituitary rongeurs, 3 and 5 mm burr. The interior endplate of C6 and superior endplate of C7 was likewise was drilled down together with posteroinferior edge of C6 and the posterior superior edge of C7. There was note of a new osteophyte on the left C6-C7 foramen. This was carefully drilled down. After decompression and removal of pressure, there was noted to be release of the epidural space with no significant venous bleeders. They were controlled with slight bipolar coagulation, temporary tamponade with Gelfoam. After this was completed, Valsalva maneuver showed no evidence of any CSF leakage. A 7-mm implant was then tapped into placed after its interior was packed with Vitoss. The plate was then applied and secured in place with four 12 x 4.7 mm screws. Irrigation of the area was done. A round French 10 JP drain was laid out over the graft and exteriorized through a separate stab incision on the patient's right inferiorly. The wound was then closed in layers with Vicryl 3-0 inverted interrupted sutures as well as Vicryl 4-0 subcuticular stitch for the dermis. The wound was reinforced with Dermabond. The catheter was anchored to the skin with nylon 3-0 stitch and dressing was applied only at the exit site. C-collar was placed and the patient was transferred to Recovery after extubation. | null |
1,251 | Anterior cervical discectomy with decompression, anterior cervical fusion, anterior cervical instrumentation, and Allograft C5-C6. | Surgery | Anterior Cervical Discectomy & Decompression - 1 | PREOPERATIVE DIAGNOSES,1. Herniated disc, C5-C6.,2. Cervical spondylosis, C5-C6.,POSTOPERATIVE DIAGNOSES,1. Herniated disc, C5-C6.,2. Cervical spondylosis, C5-C6.,PROCEDURES,1. Anterior cervical discectomy with decompression, C5-C6.,2. Anterior cervical fusion, C5-C6.,3. Anterior cervical instrumentation, C5-C6.,4. Allograft C5-C6.,ANESTHESIA: ,General endotracheal.,COMPLICATIONS:, None.,PATIENT STATUS: , Taken to recovery room in stable condition.,INDICATIONS: , The patient is a 36-year-old female who has had severe, recalcitrant right upper extremity pain, numbness, tingling, shoulder pain, axial neck pain, and headaches for many months. Nonoperative measures failed to relieve her symptoms and surgical intervention was requested. We discussed reasonable risks, benefits, and alternatives of various treatment options. Continuation of nonoperative care versus the risks associated with surgery were discussed. She understood the risks including bleeding, nerve vessel damage, infection, hoarseness, dysphagia, adjacent segment degeneration, continued worsening pain, failed fusion, and potential need for further surgery. Despite these risks, she felt that current symptoms will be best managed operatively.,SUMMARY OF SURGERY IN DETAIL: , Following informed consent and preoperative administration of antibiotics, the patient was brought to the operating suite. General anesthetic was administered. The patient was placed in the supine position. All prominences and neurovascular structures were well accommodated. The patient was noted to have pulse in this position. Preoperative x-rays revealed appropriate levels for skin incision. Ten pound inline traction was placed via Gardner-Wells tongs and shoulder roll was placed. The patient was then prepped and draped in sterile fashion. Standard oblique incision was made over the C6 vertebral body in the proximal nuchal skin crease. Subcutaneous tissue was dissected down to the level of the omohyoid which was transected. Blunt dissection was carried out with the trachea and the esophagus in the midline and the carotid sheath in its vital structures laterally. This was taken down to the prevertebral fascia which was bluntly split. Intraoperative x-ray was taken to ensure proper levels. Longus colli was identified and reflected proximally 3 to 4 mm off the midline bilaterally so that the anterior cervical Trimline retractor could be placed underneath the longus colli, thus placing no new traction on the surrounding vital structures. Inferior spondylosis was removed with high-speed bur. A scalpel and curette was used to remove the disc. Decompression was carried posterior to the posterior longitudinal ligament down to the uncovertebral joints bilaterally. Disc herniation was removed from the right posterolateral aspect of the interspace. High-speed bur was used to prepare the endplate down to good bleeding bone and preparation for fusion. Curette and ball tip dissector was then passed out the foramen and along the ventral aspect of the dura. No further evidence of compression was identified. Hemostasis was achieved with thrombin-soaked Gelfoam. Interspace was then distracted with Caspar pin distractions set gently. Interspace was then gently retracted with the Caspar pin distraction set. An 8-mm allograft was deemed in appropriate fit. This was press fit with demineralized bone matrix and tamped firmly into position achieving excellent interference fit. The graft was stable to pull-out forces. Distraction and traction was then removed and anterior cervical instrumentation was completed using a DePuy Trimline anterior cervical plate with 14-mm self-drilling screws. Plate and screws were then locked to the plate. Final x-rays revealed proper positioning of the plate, excellent distraction in the disc space, and apposition of the endplates and allograft. Wounds were copiously irrigated with normal saline. Omohyoid was approximated with 3-0 Vicryl. Running 3-0 Vicryl was used to close the platysma. Subcuticular Monocryl and Steri-Strips were used to close the skin. A deep drain was placed prior to wound closure. The patient was then allowed to awake from general anesthetic and was taken to the recovery room in stable condition. There were no intraoperative complications. All needle and sponge counts were correct. Intraoperative neurologic monitoring was used throughout the entirety of the case and was normal. | surgery, cervical spondylosis, cervical fusion, decompression, instrumentation, anterior cervical discectomy, anterior cervical, herniated disc, cervical discectomy, anterior, cervical, fusion, allograft, discectomy |
1,252 | Anterior cervical discectomy and fusion, C2-C3, C3-C4. Removal of old instrumentation, C4-C5. Fusion C3-C4 and C2-C3 with instrumentation using ABC plates. | Surgery | Anterior Cervical Discectomy & Fusion - 1 | PREOPERATIVE DIAGNOSES,1. Herniated nucleus pulposus C2-C3.,2. Spinal stenosis C3-C4.,POSTOPERATIVE DIAGNOSES,1. Herniated nucleus pulposus C2-C3.,2. Spinal stenosis C3-C4.,PROCEDURES,1. Anterior cervical discectomy, C3-C4, C2-C3.,2. Anterior cervical fusion, C2-C3, C3-C4.,3. Removal of old instrumentation, C4-C5.,4. Fusion C3-C4 and C2-C3 with instrumentation using ABC plates.,PROCEDURE IN DETAIL: , The patient was placed in the supine position. The neck was prepped and draped in the usual fashion for anterior cervical discectomy. A high incision was made to allow access to C2-C3. Skin and subcutaneous tissue and the platysma were divided sharply exposing the carotid sheath which was retracted laterally and the trachea and esophagus were retracted medially. This exposed the vertebral bodies of C2-C3 and C4-C5 which was bridged by a plate. We placed in self-retaining retractors. With the tooth beneath the blades, the longus colli muscles were dissected away from the vertebral bodies of C2, C3, C4, and C5. After having done this, we used the all-purpose instrumentation to remove the instrumentation at C4-C5, we could see that fusion at C4-C5 was solid.,We next proceeded with the discectomy at C2-C3 and C3-C4 with disc removal. In a similar fashion using a curette to clean up the disc space and the space was fairly widened, as well as drilling up the vertebral joints using high-speed cutting followed by diamond drill bit. It was obvious that the C3-C4 neural foramina were almost totally obliterated due to the osteophytosis and foraminal stenosis. With the operating microscope; however, we had good visualization of these nerve roots, and we were able to ___________ both at C2-C3 and C3-C4. We then placed the ABC 55-mm plate from C2 down to C4. These were secured with 16-mm titanium screws after excellent purchase. We took an x-ray which showed excellent position of the plate, the screws, and the graft themselves. The next step was to irrigate the wound copiously with saline and bacitracin solution and s Jackson-Pratt drain was placed in the prevertebral space and brought out through a separate incision. The wound was closed with 2-0 Vicryl for subcutaneous tissues and Steri-Strips used to close the skin. Blood loss was about 50 mL. No complication of the surgery. Needle count, sponge count, cottonoid count was correct.,The operating microscope was used for the entirety for both visualization and magnification and illumination which was quite superb. At the time of surgery, he had total collapse of the C2, C3, and C4 disc with osteophyte formation. At both levels, he has high-grade spinal stenosis at these levels, especially foramen stenosis causing the compression, neck pain, headaches, and arm and shoulder pain. He does have degenerative changes at C5-C6, C6-C7, C7-T1; however, they do not appear to be symptomatic, although x-rays show the disks to be partially collapsed at all levels with osteophyte formation beginning to form. | surgery, abc plates, osteophyte, cervical, discectomy, cervical fusion, herniated nucleus pulposus, anterior cervical discectomy, nucleus pulposus, vertebral bodies, osteophyte formation, spinal stenosis, cervical discectomy, anterior, instrumentation, vertebral, stenosis, fusion |
1,253 | Anterior cervical discectomy C4-C5 arthrodesis with 8 mm lordotic ACF spacer, corticocancellous, and stabilization with Synthes Vector plate and screws. Cervical spondylosis and herniated nucleus pulposus of C4-C5. | Surgery | Anterior Cervical Discectomy & Arthrodesis - 2 | PREOPERATIVE DIAGNOSIS: ,Cervical spondylosis and herniated nucleus pulposus of C4-C5.,POSTOPERATIVE DIAGNOSIS:, Cervical spondylosis and herniated nucleus pulposus of C4-C5.,TITLE OF OPERATION:, Anterior cervical discectomy C4-C5 arthrodesis with 8 mm lordotic ACF spacer, corticocancellous, and stabilization with Synthes Vector plate and screws.,ESTIMATED BLOOD LOSS:, Less than 100 mL.,OPERATIVE PROCEDURE IN DETAIL: , After identification, the patient was taken to the operating room and placed in supine position. Following the induction of satisfactory general endotracheal anesthesia, the patient was prepared for surgery. A shoulder roll was placed between the scapula and the head was rested on a doughnut in a slightly extended position. A preoperative x-ray was obtained to identify the operative level and neck position. An incision was marked at the C4-C5 level on the right side. The incision was opened with #10 blade knife. Dissection was carried down through subcutaneous tissues using Bovie electrocautery. The platysma muscle was divided with the cautery and mobilized rostrally and caudally. The anterior border of sternocleidomastoid muscle was then dissected rostrally and caudally with sharp and blunt dissection. The avascular plane was then entered and dissection was carried bluntly down to the anterior cervical fascia. This was opened with scissors and dissected rostrally and caudally with the peanut dissectors. The operative level was confirmed with an intraoperative x-ray. The longus colli muscles were mobilized bilaterally using bipolar electrocautery and periosteal elevator. The anterior longitudinal ligament was then taken down with the insulated Bovie electrocautery tip exposing the vertebral bodies of C4 and C5. Self-retaining retractor was placed in submuscular position, and distraction pins were placed in the vertebral bodies of C4 and C5, and distraction was instituted. We then incise the annulus of C4-C5 and a discectomy was now carried out using pituitary rongeurs and straight and angled curettes. Operating microscope was draped and brought into play. Dissection was carried down through the disc space to the posterior aspect of the disc space removing the disc with the angled curette as we went. We now use the diamond bit to thin the posterior bone spurs and osteophytes at the uncovertebral joints bilaterally. Bone was then removed with 2 mm Kerrison punch and then we were able to traverse the posterior longitudinal ligament and this ligament was now removed in a piecemeal fashion with a 2 mm Kerrison punch. There was a transligamentous disc herniation, which was removed during this process. We then carried out bilateral foraminotomies with removal of the uncovertebral osteophytes until the foramina were widely patent. Cord was seen to be pulsating freely behind the dura. There appeared to be no complications and the decompression appeared adequate. We now used a cutting bit to prepare the inner space for arthrodesis fashioning a posterior ledge on the posterior aspect of the C5 vertebral body. An 8 mm lordotic trial was used and appeared perfect. We then used a corticocancellous 8 mm lordotic graft. This was tapped into position. Distraction was released, appeared to be in excellent position. We then positioned an 18 mm Vector plate over the inner space. Intraoperative x-ray was obtained with the stay screw in place; plates appeared to be in excellent position. We then use a 14 mm self-tapping variable angle screws in each of the four locations drilling 14 mm pilot holes at each location prior to screw insertion. All of the screws locked to the plate and this was confirmed on visual inspection. Intraoperative x-ray was again obtained. Construct appeared satisfactory. Attention was then directed to closure. The wound was copiously irrigated. All of the self-retaining retractors were removed. Bleeding points were controlled with bone wax and bipolar electrocautery. The platysma layer was now closed with interrupted 3-0 Vicryl sutures. The skin was closed with running 3-0 Vicryl subcuticular stitch. Steri-Strips were applied. A sterile bandage was applied. All sponge, needle, and cottonoid counts were reported as correct. The patient tolerated the procedure well. He was subsequently extubated in the operating room and transferred to PACU in satisfactory condition. | surgery, synthes vector plate, lordotic, acf spacer, corticocancellous, arthrodesis, anterior cervical discectomy, herniated nucleus pulposus, anterior, cervical, spacer, screws, discectomy, |
1,254 | Anterior cervical discectomy at C5-6 and placement of artificial disk replacement. Right C5-C6 herniated nucleus pulposus. | Surgery | Anterior Cervical Discectomy - 2 | ADMITTING DIAGNOSIS: , Right C5-C6 herniated nucleus pulposus.,PRIMARY OPERATIVE PROCEDURE: , Anterior cervical discectomy at C5-6 and placement of artificial disk replacement.,SUMMARY:, This is a pleasant, 43-year-old woman, who has been having neck pain and right arm pain for a period of time which has not responded to conservative treatment including ESIs. She underwent another MRI and significant degenerative disease at C5-6 with a central and right-sided herniation was noted. Risks and benefits of the surgery were discussed with her and she wished to proceed with surgery. She was interested in participating in the artificial disk replacement study and was entered into that study. She was randomly picked for the artificial disk and underwent the above named procedure on 08/27/2007. She has done well postoperatively with a sensation of right arm pain and numbness in her fingers. She will have x-rays AP and lateral this morning which will be reviewed and she will be discharged home today if she is doing well. She will follow up with Dr. X in 2 weeks in the clinic as per the study protocol with cervical AP and lateral x-rays with ring prior to the appointment. She will contact our office prior to her appointment if she has problems. Prescriptions were written for Flexeril 10 mg 1 p.o. t.i.d. p.r.n. #50 with 1 refill and Lortab 7.5/500 mg 1 to 2 q.6 h. p.r.n. #60 with 1 refill. | surgery, herniated nucleus pulposus, anterior cervical discectomy, artificial disk replacement, cervical, discectomy, nucleusNOTE |
1,255 | Anterior cervical discectomy, arthrodesis, partial corpectomy, Machine bone allograft, placement of anterior cervical plate with a Zephyr.
7. Microscopic dissection. | Surgery | Anterior Cervical Discectomy & Arthrodesis | PREOPERATIVE DIAGNOSIS:, Cervical myelopathy secondary to very large disc herniations at C4-C5 and C5-C6.,POSTOPERATIVE DIAGNOSIS: , Cervical myelopathy secondary to very large disc herniations at C4-C5 and C5-C6.,PROCEDURE PERFORMED:,1. Anterior cervical discectomy, C4-C5 and C5-C6.,2. Arthrodesis, C4-C5 and C5-C6.,3. Partial corpectomy, C5.,4. Machine bone allograft, C4-C5 and C5-C6.,5. Placement of anterior cervical plate with a Zephyr C4 to C6.,6. Fluoroscopic guidance.,7. Microscopic dissection.,ANESTHESIA:, General.,ESTIMATED BLOOD LOSS: , 60 mL.,COMPLICATIONS: , None.,INDICATIONS:, This is a patient who presents with progressive weakness in the left upper extremity as well as imbalance. He has also noted to have cord signal at the C4-C5 level secondary to a very large disc herniation that came behind the body at C5 as well and as well as a large disc herniation at C5-C6. Risks and benefits of the surgery including bleeding, infection, neurologic deficit, nonunion, progressive spondylosis, and lack of improvement were all discussed. He understood and wished to proceed.,DESCRIPTION OF PROCEDURE: , The patient was brought to the operating room and placed in the supine position. Preoperative antibiotics were given. The patient was placed in the supine position with all pressure points noted and well padded. The patient was prepped and draped in standard fashion. An incision was made approximately above the level of the cricoid. Blunt dissection was used to expose the anterior portion of the spine with carotid moved laterally and trachea and esophagus moved medially. We then placed needle into the disc spaces and was found to be at C5-C6. Distracting pins were placed in the body of C4 and in to the body of C6. The disc was then completely removed at C4-C5. There was very significant compression of the cord. This was carefully removed to avoid any type of pressure on the cord. This was very severe and multiple free fragments were noted. This was taken down to the level of ligamentum. Both foramen were then also opened. Other free fragments were also found behind the body of C5, part of the body of C5 was taken down to assure that all of these were removed. The exact same procedure was done at C5-C6; however, if there were again free fragments noted, there was less not as severe compression at the C4-C5 area. Again part of the body at C5 was removed to make sure that there was no additional constriction. Both nerve roots were then widely decompressed. Machine bone allograft was placed into the C4-C5 as well as C5-C6 and then a Zephyr plate was placed in the body of C4 and to the body of C6 with a metal pin placed into the body at C5. Excellent purchase was obtained. Fluoroscopy showed good placement and meticulous hemostasis was obtained. Fascia was closed with 3-0 Vicryl, subcuticular 3-0 Dermabond for skin. The patient tolerated the procedure well and went to recovery in good condition. | surgery, fluoroscopic guidance, microscopic dissectio, cervical plate, zephyr, corpectomy, arthrodesis, anterior cervical discectomy, machine bone allograft, cervical discectomy, bone allograft, disc herniations, anterior, cervical, discectomy, |
1,256 | Herniated nucleus pulposus. Anterior cervical decompression, anterior spine instrumentation, anterior cervical spine fusion, and application of machined allograft. | Surgery | Anterior Cervical Decompression | PREOPERATIVE DIAGNOSES,1. Herniated nucleus pulposus, C5-C6.,2. Herniated nucleus pulposus, C6-C7.,POSTOPERATIVE DIAGNOSES,1. Herniated nucleus pulposus, C5-C6.,2. Herniated nucleus pulposus, C6-C7.,PROCEDURE PERFORMED,1. Anterior cervical decompression, C5-C6.,2. Anterior cervical decompression, C6-C7.,3. Anterior spine instrumentation.,4. Anterior cervical spine fusion, C5-C6.,5. Anterior cervical spine fusion, C6-C7.,6. Application of machined allograft at C5-C6.,7. Application of machined allograft at C6-C7.,8. Allograft, structural at C5-C6.,9. Allograft, structural at C6-C7.,ANESTHESIA: , General.,PREOPERATIVE NOTE: ,This patient is a 47-year-old male with chief complaint of severe neck pain and left upper extremity numbness and weakness. Preoperative MRI scan showed evidence of herniated nucleus pulposus at C5-C6 and C6-C7 on the left. The patient has failed epidural steroid injections. Risks and benefits of the above procedure were discussed with the patient including bleeding, infection, muscle loss, nerve damage, paralysis, and death.,OPERATIVE REPORT: , The patient was taken to the OR and placed in the supine position. After general endotracheal anesthesia was obtained, the patient's neck was sterilely prepped and draped in the usual fashion. A horizontal incision was made on the left side of the neck at the level of the C6 vertebral body. It was taken down through the subcutaneous tissues exposing the platysmus muscle. The platysmus muscle was incised along the skin incision and the deep cervical fascia was bluntly dissected down to the anterior cervical spine. An #18 gauge needle was placed in the C5-C6 interspace and the intraoperative x-ray confirmed that this was the appropriate level. Next, the longus colli muscles were resected laterally on both the right and left side, and then a complete anterior cervical discectomy was performed. The disk was very degenerated and brown in color. There was an acute disk herniation through posterior longitudinal ligament. The posterior longitudinal ligament was removed and a bilateral foraminotomy was performed. Approximately, 5 mm of the nerve root on both the right and left side was visualized. A ball-ended probe could be passed up the foramen. Bleeding was controlled with bipolar electrocautery and Surgiflo. The end plates of C5 and C6 were prepared using a high-speed burr and a 6-mm lordotic machined allograft was malleted into place. There was good bony apposition both proximally and distally. Next, attention was placed at the C6-C7 level. Again, the longus colli muscles were resected laterally and a complete anterior cervical discectomy at C6-C7 was performed. The disk was degenerated and there was acute disk herniation in the posterior longitudinal ligament on the left. The posterior longitudinal ligament was removed. A bilateral foraminotomy was performed. Approximately, 5 mm of the C7 nerve root was visualized on both sides. A micro nerve hook was able to be passed up the foramen easily. Bleeding was controlled with bipolar electrocautery and Surgiflo. The end plates at C6-C7 were then prepared using a high-speed burr and then a 7-mm machined lordotic allograft was malleted into place. There was good bony apposition, both proximally and distally. Next, a 44-mm Blackstone low-profile anterior cervical plate was applied to the anterior cervical spine with six 14 mm screws. Intraoperative x-ray confirmed appropriate positioning of the plate and the graft. The wound was then copiously irrigated with normal saline and bacitracin. There was no active bleeding upon closure of the wound. A small drain was placed deep. The platysmal muscle was closed with 3-0 Vicryl. The skin was closed with #4-0 Monocryl. Mastisol and Steri-Strips were applied. The patient was monitored throughout the procedure with free-running EMGs and SSEPs and there were no untoward events. The patient was awoken and taken to the recovery room in satisfactory condition. | surgery, herniated nucleus pulposus, anterior cervical decompression, spine fusion, cervical spine, allograft, anterior cervical spine, anterior, cervical, |
1,257 | Arthrodesis - anterior interbody technique, anterior cervical discectomy, anterior instrumentation with a 23-mm Mystique plate and the 13-mm screws, implantation of machine bone implant. Disc herniation with right arm radiculopathy. | Surgery | Anterior Cervical Discectomy & Arthrodesis - 1 | PREOPERATIVE DIAGNOSES: , C5-C6 disc herniation with right arm radiculopathy.,POSTOPERATIVE DIAGNOSES: , C5-C6 disc herniation with right arm radiculopathy.,PROCEDURE:,1. C5-C6 arthrodesis, anterior interbody technique.,2. C5-C6 anterior cervical discectomy.,3. C5-C6 anterior instrumentation with a 23-mm Mystique plate and the 13-mm screws.,4. Implantation of machine bone implant.,5. Microsurgical technique.,ANESTHESIA: ,General endotracheal.,ESTIMATED BLOOD LOSS: , Less than 100 mL.,BACKGROUND INFORMATION AND SURGICAL INDICATIONS: ,The patient is a 45-year-old right-handed gentleman who presented with neck and right arm radicular pain. The pain has become more and more severe. It runs to the thumb and index finger of the right hand and it is accompanied by numbness. If he tilts his neck backwards, the pain shoots down the arm. If he is working with the computer, it is very difficult to use his mouse. He tried conservative measures and failed to respond, so he sought out surgery. Surgery was discussed with him in detail. A C5-C6 anterior cervical discectomy and fusion was recommended. He understood and wished to proceed with surgery. Thus, he was brought in same day for surgery on 07/03/2007.,DESCRIPTION OF PROCEDURE: , He was given Ancef 1 g intravenously for infection prophylaxis and then transported to the OR. There general endotracheal anesthesia was induced. He was positioned on the OR table with an IV bag between the scapulae. The neck was slightly extended and taped into position. A metal arch was placed across the neck and intraoperative x-ray was obtain to verify a good position for skin incision and the neck was prepped with Betadine and draped in the usual sterile fashion.,A linear incision was created in the neck beginning just to the right of the midline extending out across the anterior border of the sternocleidomastoid muscle. The incision was extended through skin, subcutaneous fat, and platysma. Hemostasis was assured with Bovie cautery. The anterior aspect of the sternocleidomastoid muscle was identified and dissection was carried medial to this down to the carotid sheath. The trachea and the esophagus were swept out of the way and dissection proceeded medial to the carotid sheath down between the two bellies of the longus colli muscle on to the anterior aspect of the spine. A Bovie cautery was used to mobilize the longus colli muscle around initially what turned out to be C6-C7 disk based on x-rays and then around the C5-C6 disk space. An intraoperative x-ray confirmed C5-C6 disk space had been localized and then the self-retained distraction system was inserted to maintain exposure. A 15-blade knife was used to incise the C5-C6 disk and remove disk material. and distraction pins were inserted into C5-C6 and distraction placed across the disk space. The operating microscope was then brought into the field and used throughout the case except for the closure. Various pituitaries, #15 blade knife, and curette were used to evacuate the disk as best as possible. Then, the Midas Rex drill was taken under the microscope and used to drill where the cartilaginous endplate driven back all the way into the posterior aspect of the vertebral body. A nerve hook was swept underneath the posterior longitudinal ligament and a fragment of disk was produced and was pulled up through the ligament. A Kerrison rongeur was used to open up the ligament in this opening and then to march out in the both neural foramina. A small amount of disk material was found at the right neural foramen. After a good decompression of both neural foramina was obtained and the thecal sac was exposed throughout the width of the exposure, the wound was thoroughly irrigated. A spacing mechanism was intact into the disk space and it was determined that a #7 spacer was appropriate. So, a #7 machine bone implant was taken and tapped into disk space and slightly counter sunk. The wound was thoroughly irrigated and inspected for hemostasis. A Mystique plate 23 mm in length was then inserted and anchored to the anterior aspect of C5-C6 to hold the bone into position and the wound was once again irrigated. The patient was valsalved. There was no further bleeding seen and intraoperative x-ray confirmed a good position near the bone, plate, and screws and the wound was enclosed in layers. The 3-0 Vicryl was used to approximate platysma and 3-0 Vicryl was used in inverted interrupted fashion to perform a subcuticular closure of the skin. The wound was cleaned.,Mastisol was placed on the skin, and Steri-strips were used to approximate skin margins. Sterile dressing was placed on the patient's neck. He was extubated in the OR and transported to the recovery room in stable condition. There were no complications. | surgery, herniation, radiculopathy, interbody, mystique, bone implant, anterior cervical discectomy, neural foramina, mystique plate, disc herniation, arm radiculopathy, cervical discectomy, disk space, disk, cervical, anterior, wound, discectomy, |
1,258 | Anterior cervical discectomy, removal of herniated disc and osteophytes, bilateral C4 nerve root decompression, harvesting of bone for autologous vertebral bodies for creation of arthrodesis, grafting of fibular allograft bone for creation of arthrodesis, creation of arthrodesis via an anterior technique with fibular allograft bone and autologous bone from the vertebral bodies, and placement of anterior spinal instrumentation using the operating microscope and microdissection technique. | Surgery | Anterior Cervical Discectomy - 1 | PREOPERATIVE DIAGNOSIS: , Cervical spondylosis at C3-C4 with cervical radiculopathy and spinal cord compression.,POSTOPERATIVE DIAGNOSIS:, Cervical spondylosis at C3-C4 with cervical radiculopathy and spinal cord compression.,OPERATION PERFORMED,1. Anterior cervical discectomy of C3-C4.,2. Removal of herniated disc and osteophytes.,3. Bilateral C4 nerve root decompression.,4. Harvesting of bone for autologous vertebral bodies for creation of arthrodesis.,5. Grafting of fibular allograft bone for creation of arthrodesis.,6. Creation of arthrodesis via an anterior technique with fibular allograft bone and autologous bone from the vertebral bodies.,7. Placement of anterior spinal instrumentation using the operating microscope and microdissection technique.,INDICATIONS FOR PROCEDURE: , This 62-year-old man has progressive and intractable right C4 radiculopathy with neck and shoulder pain. Conservative therapy has failed to improve the problem. Imaging studies showed severe spondylosis of C3-C4 with neuroforaminal narrowing and spinal cord compression.,A detailed discussion ensued with the patient as to the nature of the procedure including all risks and alternatives. He clearly understood it and had no further questions and requested that I proceed.,PROCEDURE IN DETAIL: , The patient was placed on the operating room table and was intubated using a fiberoptic technique. The methylprednisolone spinal cord protocol was instituted with bolus and continuous infusion doses. The neck was carefully prepped and draped in the usual sterile manner.,A transverse incision was made on a skin crease on the left side of the neck. Dissection was carried down through the platysmal musculature and the anterior spine was exposed. The medial borders of the longus colli muscles were dissected free from their attachments to the spine. A needle was placed and it was believed to be at the C3-C4 interspace and an x-ray properly localized this space. Castoff self-retaining pins were placed into the body of the C3 and C4. Self-retaining retractors were placed in the wound keeping the blades of the retractors underneath the longus colli muscles.,The annulus was incised and a discectomy was performed. Quite a bit of overhanging osteophytes were identified and removed. As I worked back to the posterior lips of the vertebral body, the operating microscope was utilized.,There was severe overgrowth of spondylitic spurs. A high-speed diamond bur was used to slowly drill these spurs away. I reached the posterior longitudinal ligament and opened it and exposed the underlying dura.,Slowly and carefully I worked out towards the C3-C4 foramen. The dura was extremely thin and I could see through it in several areas. I removed the bony compression in the foramen and identified soft tissue and veins overlying the root. All of these were not stripped away for fear of tearing this very tissue-paper-thin dura. However, radical decompression was achieved removing all the bony compression in the foramen, out to the pedicle, and into the foramen. An 8-mm of the root was exposed although I left the veins over the root intact.,The microscope was angled to the left side where a similar procedure was performed.,Once the decompression was achieved, a high-speed cortisone bur was used to decorticate the body from the greater posterior shelf to prevent backward graft migration. Bone thus from the drilling was preserved for use for the arthrodesis.,Attention was turned to creation of the arthrodesis. As I had drilled quite a bit into the bodies, I selected a large 12-mm graft and distracted the space maximally. Under distraction the graft was placed and fit well. An x-ray showed good graft placement.,Attention was turned to spinal instrumentation. A Synthes Short Stature plate was used with four 3-mm screws. Holes were drilled with all four screws were placed with pretty good purchase. Next, the locking screws were then applied. An x-ray was obtained which showed good placement of graft, plate, and screws. The upper screws were near the upper endplate of C3. The C3 vertebral body that remained was narrow after drilling off the spurs. Rather than replace these screws and risk that the next holes would be too near the present holes I decided to leave these screws intact because their position is still satisfactory as they are below the disc endplate.,Attention was turned to closure. A Hemovac drain was placed in the anterior vertebral body space and brought out through a separate stab wound incision in the skin. The wound was then carefully closed in layers. Sterile dressings were applied along with a rigid Philadelphia collar. The operation was then terminated.,The patient tolerated the procedure well and left for the recovery room in excellent condition. The sponge and needle counts were reported as correct and there were no intraoperative complications.,Specimens were sent to Pathology consisted of bone and soft tissue as well as C3-C4 disc material. | surgery, herniated, osteophytes, nerve root decompression, harvesting, autologous, vertebral, arthrodesis, anterior technique, anterior cervical discectomy, spinal cord compression, fibular allograft bone, creation of arthrodesis, cervical discectomy, spinal instrumentation, cord compression, vertebral body, vertebral bodies, spinal cord, bone, instrumentation, cervical, anterior, grafting, spinal, discectomy, allograft, |
1,259 | C5-C6 anterior cervical discectomy, bone bank allograft, and anterior cervical plate. Left cervical radiculopathy. | Surgery | Anterior Cervical Discectomy - 4 | PREOPERATIVE DIAGNOSIS: , Left cervical radiculopathy.,POSTOPERATIVE DIAGNOSIS: ,Left cervical radiculopathy.,PROCEDURES PERFORMED:,1. C5-C6 anterior cervical discectomy.,2. Bone bank allograft.,3. Anterior cervical plate.,TUBES AND DRAINS LEFT IN PLACE: , None.,COMPLICATIONS: , None.,SPECIMEN SENT TO PATHOLOGY: , None.,ANESTHESIA: , General endotracheal.,INDICATIONS: , This is a middle-aged man who presented to me with left arm pain. He had multiple levels of disease, but clinically, it was C6 radiculopathy. We tested him in the office and he had weakness referable to that nerve. The procedure was done at that level.,DESCRIPTION OF PROCEDURE: , The patient was taken to the operating room at which time an intravenous line was placed. General endotracheal anesthesia was obtained. He was positioned supine in the operative area and the right neck was prepared.,An incision was made and carried down to the ventral spine on the right in the usual manner. An x-ray confirmed our location.,We were impressed by the degenerative change and the osteophyte overgrowth.,As we had excepted, the back of the disk space was largely closed off by osteophytes. We patiently drilled through them to the posterior ligament. We went through that until we saw the dura.,We carefully went to the patient's symptomatic, left side. The C6 foramen was narrowed by uncovertebral joint overgrowth. The foramen was open widely.,An allograft was placed. An anterior Steffee plate was placed. Closure was commenced.,The wound was closed in layers with Steri-Strips on the skin. A dressing was applied.,It should be noted that the above operation was done also with microscopic magnification and illumination. | surgery, cervical radiculopathy, anterior cervical discectomy, bank allograft, cervical discectomy, anterior, cervical, foramen, discectomy, allograft, radiculopathy, |
1,260 | Anterior cervical discectomy (two levels) and C5-C6 and C6-C7 allograft fusions. A C5-C7 anterior cervical plate fixation (Sofamor Danek titanium window plate) intraoperative fluoroscopy used and intraoperative microscopy used. Intraoperative SSEP and EMG monitoring used. | Surgery | Anterior Cervical Discectomy - 3 | PREOPERATIVE DIAGNOSES: , Cervical disk protrusions at C5-C6 and C6-C7, cervical radiculopathy, and cervical pain.,POSTOPERATIVE DIAGNOSES:, Cervical disk protrusions at C5-C6 and C6-C7, cervical radiculopathy, and cervical pain.,PROCEDURES:, C5-C6 and C6-C7 anterior cervical discectomy (two levels) C5-C6 and C6-C7 allograft fusions. A C5-C7 anterior cervical plate fixation (Sofamor Danek titanium window plate) intraoperative fluoroscopy used and intraoperative microscopy used. Intraoperative SSEP and EMG monitoring used.,ANESTHESIA: , General endotracheal.,COMPLICATIONS:, None.,INDICATION FOR THE PROCEDURE: , This lady presented with history of cervical pain associated with cervical radiculopathy with cervical and left arm pain, numbness, weakness, with MRI showing significant disk protrusions with the associate complexes at C5-C6 and C6-C7 with associated cervical radiculopathy. After failure of conservative treatment, this patient elected to undergo surgery.,DESCRIPTION OF PROCEDURE: ,The patient was brought to the OR and after adequate general endotracheal anesthesia, she was placed supine on the OR table with the head of the bed about 10 degrees. A shoulder roll was placed and the head supported on a donut support. The cervical region was prepped and draped in the standard fashion. A transverse cervical incision was made from the midline, which was lateral to the medial edge of the sternocleidomastoid two fingerbreadths above the right clavicle. In a transverse fashion, the incision was taken down through the skin and subcutaneous tissue and through the platysmata and a subplatysmal dissection done. Then, the dissection continued medial to the sternocleidomastoid muscle and then medial to the carotid artery to the prevertebral fascia, which was gently dissected and released superiorly and inferiorly. Spinal needles were placed into the displaced C5-C6 and C6-C7 to confirm these disk levels using lateral fluoroscopy. Following this, monopolar coagulation was used to dissect the medial edge of the longus colli muscles off the adjacent vertebrae between C5-C7 and then the Trimline retractors were placed to retract the longus colli muscles laterally and blunt retractors were placed superiorly and inferiorly. A #15 scalpel was used to do a discectomy at C5-C6 from endplate-to-endplate and uncovertebral joint. On the uncovertebral joint, a pituitary rongeur was used to empty out any disk material ____________ to further remove the disk material down to the posterior aspect. This was done under the microscope. A high-speed drill under the microscope was used to drill down the endplates to the posterior aspect of the annulus. A blunt trocar was passed underneath the posterior longitudinal ligament and it was gently released using the #15 scalpel and then Kerrison punches 1-mm and then 2-mm were used to decompress further disk calcified material at the C5-C6 level. This was done bilaterally to allow good decompression of the thecal sac and adjacent neuroforamen. Then, at the C6-C7 level, in a similar fashion, #15 blade was used to do a discectomy from uncovertebral joint to uncovertebral joint and from endplate-to-endplate using a #15 scalpel to enter the disk space and then the curette was then used to remove the disk calcified material in the endplate, and then high-speed drill under the microscope was used to drill down the disk space down to the posterior aspect of the annulus where a blunt trocar was passed underneath the posterior longitudinal ligament which was gently released. Then using the Kerrison punches, we used 1-mm and 2-mm, to remove disk calcified material, which was extending more posteriorly to the left and the right. This was gently removed and decompressed to allow good decompression of the thecal sac and adjacent nerve roots. With this done, the wound was irrigated. Hemostasis was ensured with bipolar coagulation. Vertebral body distraction pins were then placed to the vertebral body of C5 and C7 for vertebral distraction and then a 6-mm allograft performed grafts were taken and packed in either aspect with demineralized bone matrix and this was tapped in flush with the vertebral bodies above and below C5-C6 and C6-C7 discectomy sites. Then, the vertebral body distraction pins were gently removed to allow for graft seating and compression and then the anterior cervical plate (Danek windows titanium plates) was then taken and sized and placed. A temporary pin was initially used to align the plate and then keeping the position and then two screw holes were drilled in the vertebral body of C5, two in the vertebral body of C6, and two in the vertebral body of C7. The holes were then drilled and after this self-tapping screws were placed into the vertebral body of C5, C6, and C7 across the plate to allow the plate to fit and stay flush with the vertebral body between C5, C6, and C7. With this done, operative fluoroscopy was used to check good alignment of the graft, screw, and plate, and then the wound was irrigated. Hemostasis was ensured with bipolar coagulation and then the locking screws were tightened down. A #10 round Jackson-Pratt drain was placed into the prevertebral space and brought out from a separate stab wound skin incision site. Then, the platysma was approximated using 2-0 Vicryl inverted interrupted stitches and the skin closed with 4-0 Vicryl running subcuticular stitch. Steri-Strips and sterile dressings were applied. The patient remained hemodynamically stable throughout the procedure. Throughout the procedure, the microscope had been used for the disk decompression and high-speed drilling. In addition, intraoperative SSEP, EMG monitoring, and motor-evoked potentials remained stable throughout the procedure. The patient remained stable throughout the procedure. | surgery, cervical disk protrusions, cervical radiculopathy, cervical pain, cervical plate fixation, sofamor danek titanium window plate, anterior cervical discectomy, vertebral body, vertebral, disk, intraoperative, anterior, decompression, fluoroscopy, radiculopathy, discectomy, cervical, |
1,261 | Anterior cervical discectomy and removal of herniated disk and osteophytes and decompression of spinal cord and bilateral nerve root decompression. Harvesting of autologous bone from the vertebral bodies. Grafting of allograft bone for creation of arthrodesis. | Surgery | Anterior Cervical Discectomy | PREOPERATIVE DIAGNOSES,1. Cervical spondylosis with myelopathy.,2. Herniated cervical disk, C4-C5.,POSTOPERATIVE DIAGNOSES,1. Cervical spondylosis with myelopathy.,2. Herniated cervical disk, C4-C5.,OPERATIONS PERFORMED,1. Anterior cervical discectomy and removal of herniated disk and osteophytes and decompression of spinal cord at C5-C6.,2. Bilateral C6 nerve root decompression.,3. Anterior cervical discectomy at C4-C5 with removal of herniated disk and osteophytes and decompression of spinal cord.,4. Bilateral C5 nerve root decompression.,5. Anterior cervical discectomy at C3-C4 with removal of herniated disk and osteophytes, and decompression of spinal cord.,6. Bilateral C4 nerve root decompression.,7. Harvesting of autologous bone from the vertebral bodies.,8. Grafting of allograft bone for creation of arthrodesis.,9. Creation of arthrodesis with allograft bone and autologous bone from the vertebral bodies and bone morphogenetic protein at C5-C6.,10. Creation of additional arthrodesis using allograft bone and autologous bone from the vertebral bodies and bone morphogenetic protein at C4-C5.,11. Creation of additional arthrodesis using allograft bone and autologous bone from the vertebral bodies and bone morphogenetic protein at C3-C4.,12. Placement of anterior spinal instrumentation from C3 to C6 using a Synthes Small Stature Plate, using the operating microscope and microdissection technique.,INDICATIONS FOR PROCEDURE: , This 62-year-old man has severe cervical spondylosis with myelopathy and cord compression at C5-C6. There was a herniated disk with cord compression and radiculopathy at C4-C5. C3-C4 was the source of neck pain as documented by facet injections.,A detailed discussion ensued with the patient as to the pros and cons of the surgery by two levels versus three levels. Because of the severe component of the neck pain that has been relieved with facet injections, we elected to proceed ahead with anterior cervical discectomy and fusion at C3-C4, C4-C5, and C5-C6.,I explained the nature of this procedure in great detail including all risks and alternatives. He clearly understands and has no further questions and requests that I proceed.,PROCEDURE: ,The patient was placed on the operating room table and was intubated taking great care to keep the neck in a neutral position. The methylprednisolone spinal cord protocol was instituted with bolus and continuous infusion dosages.,The left side of the neck was carefully prepped and draped in the usual sterile manner.,A transverse incision was made in the neck crease. Dissection was carried down through the platysma musculature and the anterior spine was exposed. The medial borders of the longus colli muscle were dissected free from their attachments to the spine. Caspar self-retaining pins were placed into the bodies of C3, C4, C5, and C6 and x-ray localization was obtained. A needle was placed in what was revealed to be the disk space at C4-C5 and an x-ray confirmed proper localization.,Self-retaining retractors were then placed in the wound, taking great care to keep the blades of the retractors underneath the longus colli muscles.,First I removed the large amount of anterior overhanging osteophytes at C5-C6 and distracted the space. The high-speed cutting bur was used to drill back the osteophytes towards the posterior lips of the vertebral bodies.,An incision was then made at C4-C5 and the annulus was incised and a discectomy was performed back to the posterior lips of the vertebral bodies.,The retractors were then adjusted and again discectomy was performed at C3-C4 back to the posterior lips of the vertebral bodies. The operating microscope was then utilized.,Working under magnification, I started at C3-C4 and began to work my way down to the posterior longitudinal ligament. The ligament was incised and the underlying dura was exposed. I worked out laterally towards the takeoff of the C4 nerve root and widely decompressed the nerve root edge of the foramen. There were a large number of veins overlying the nerve root which were oozing and rather than remove these and produce tremendous amount of bleeding, I left them intact. However, I could to palpate the nerve root along the pedicle into the foramen and widely decompressed it on the right. The microscope was angled to the left side where similar decompression was achieved.,The retractors were readjusted and attention was turned to C4-C5. I worked down through bony osteophytes and identified the posterior longitudinal ligament. The ligament was incised; and as I worked to the right of the midline, I encountered herniated disk material which was removed in a number of large pieces. The C5 root was exposed and then widely decompressed until I was flush with the pedicle and into the foramen. The root had a somewhat high takeoff but I worked to expose the axilla and widely decompressed it. Again the microscope was angled to the left side where similar decompression was achieved. Central decompression was achieved here where there was a moderate amount of spinal cord compression. This was removed by undercutting with 1 and 2-mm Cloward punches.,Attention was then turned to the C5-C6 space. Here there were large osteophytes projecting posteriorly against the cord. I slowly and carefully used the high-speed cutting diamond bur to drill these and then used 1 to 2-mm Cloward punches to widely decompress the spinal cord. This necessitated undercutting the bodies of both C5 and C6 extensively, but I was then able to achieve a good decompression of the cord. I exposed the C6 root and widely decompressed it until I was flush with the pedicle and into the foramen on the right. The microscope was angled to the left side where a similar decompression was achieved.,Attention was then turned to creation of the arthrodesis. A high-speed Cornerstone bur was used to decorticate the bodies of C5-C6, C4-C5 and C3-C4 to create a posterior shelf to prevent backwards graft migration. Bone dust during the drilling was harvested for later use.,Attention was turned to creation of the arthrodesis. Using the various Synthes sizers, I selected a 7-mm lordotic graft at C5-C6 and an 8-mm lordotic graft at C4-C5 and a 9-mm lordotic graft at C3-C4. Each graft was filled with autologous bone from the vertebral bodies and bone morphogenetic protein soaked sponge. I decided to use BMP in this case because there were three levels of fusion and because this patient has a very heavy history of smoking and having just recently discontinued for two weeks. The BMP sponge and the ____________ bone were then packed in the center of the allograft.,Under distraction, the graft was placed at C3-C4, C4-C5, and C5-C6 as described. An x-ray was obtained which showed good graft placement with preservation of the cervical lordosis.,Attention was turned to the placement of anterior spinal instrumentation. Various sizes of Synthes plates were selected until I decided that a 54-mm plate was appropriate. The plate had to be somewhat contoured and bent inferiorly and the vertebral bodies had to be drilled so that the plates would sit flush. The holes were drilled and the screws were placed. Eight screws were placed with two screws at C3, two screws at C4, two screws at C5, and two screws at C6. All eight screws had good purchase. The locking screws were tightly applied. An x-ray was obtained which showed good placement of the graft, plate, and screws.,Attention was turned to closure. The wound was copiously irrigated with Bacitracin solution and meticulous hemostasis was obtained. A medium Hemovac drain was placed in the anterior vertebral body space and brought out through a separate stab incision in the skin. The wound was then carefully closed in layers. Sterile dressings were applied, and the operation was terminated.,The patient tolerated the procedure well and left for the recovery room in excellent condition. The sponge and needle counts were reported as correct. There were no intraoperative complications.,Specimens were sent to Pathology consisting of disk material and bone and soft tissue. | null |
1,262 | Selective coronary angiography of the right coronary artery, left main LAD, left circumflex artery, left ventricular catheterization, left ventricular angiography, angioplasty of totally occluded mid RCA, arthrectomy using 6-French catheter, stenting of the mid RCA, stenting of the proximal RCA, femoral angiography and Perclose hemostasis. | Surgery | Angiography & Catheterization - 1 | INDICATION:, Acute coronary syndrome.,CONSENT FORM: , The procedure of cardiac catheterization/PCI risks included but not restricted to death, myocardial infarction, cerebrovascular accident, emergent open heart surgery, bleeding, hematoma, limb loss, renal failure requiring dialysis, blood loss, infection had been explained to him. He understands. All questions answered and is willing to sign consent.,PROCEDURE PERFORMED:, Selective coronary angiography of the right coronary artery, left main LAD, left circumflex artery, left ventricular catheterization, left ventricular angiography, angioplasty of totally occluded mid RCA, arthrectomy using 6-French catheter, stenting of the mid RCA, stenting of the proximal RCA, femoral angiography and Perclose hemostasis.,NARRATIVE: , The patient was brought to the cardiac catheterization laboratory in a fasting state. Both groins were draped and sterilized in the usual fashion. Local anesthesia was achieved with 2% lidocaine to the right groin area and a #6-French femoral sheath was inserted via modified Seldinger technique in the right common femoral artery. Selective coronary angiography was performed with #6 French JL4 catheter for the left coronary system and a #6 French JR4 catheter of the right coronary artery. Left ventricular catheterization and angiography was performed at the end of the procedure with a #6-French angle pigtail catheter.,FINDINGS,1. Hemodynamics systemic blood pressure 140/70 mmHg. LVEDP at the end of the procedure was 13 mmHg.,2. The left main coronary artery is a large with mild diffuse disease in the distal third resulting in less than 20% angiographic stenosis at the take off of the left circumflex artery. The left circumflex artery is a large caliber vessel with diffuse disease in the ostium of the proximal segment resulting in less than 30% angiographic stenosis. The left circumflex artery gives rise to a high small obtuse marginal branch that has high moderate-to-severe ostium. The rest of the left circumflex artery has mild diffuse disease and it gives rise to a second large obtuse marginal branch that bifurcates into an upper and lower trunk.,The LAD is calcified and diffusely disease in the proximal and mid portion. There is mild nonobstructive disease in the proximal LAD resulting in less than 20% angiographic stenosis.,3. The right coronary artery is dominant. It is septal to be occluded in the mid portion.,The findings were discussed with the patient and she opted for PCI. Angiomax bolus was started. The ACT was checked. It was higher in 300. I have given the patient 600 mg of oral Plavix.,The right coronary artery was engaged using a #6-French JR4 guide catheter. I was unable to cross through this lesion using a BMW wire and a 3.0x8 mm balloon support. I was unable to cross with this lesion using a whisper wire. I was unable to cross with this lesion using Cross-IT 100 wire. I have also used second #6-French Amplatz right I guide catheter. At one time, I have lost flow in the distal vessel. The patient experienced severe chest pain, ST-segment elevation, bradycardia, and hypotension, which responded to intravenous fluids and atropine along with intravenous dopamine.,Dr. X was notified.,Eventually, an Asahi grand slam wire using the same 3.0 x 8 mm Voyager balloon support, I was able to cross into the distal vessel. I have performed careful balloon angioplasty of the mid RCA. I have given nitroglycerin under the nursing several times during the procedure.,I then performed arthrectomy using #5-French export catheter.,I performed more balloon predilation using a 3.0 x16 mm Voyager balloon. I then deployed 4.0 x15 mm, excised, and across the mid RCA at 18 atmospheres with good angiographic result. Proximal to the proximal edge of the stent, there was still some persistent haziness most likely just diseased artery/diffuse plaquing. I decided to cover this segment using a second 4.0 x 15 mm, excised, and two stents were overlapped, the overlap was postdilated using the same stent delivery balloon at high pressure with excellent angiographic result.,Left ventricular catheterization was performed with #6-French angle pigtail catheter. The left ventricle is rather smaller in size. The mid inferior wall is minimally hypokinetic, ejection fraction is 70%. There is no evidence of aortic wall stenosis or mitral regurgitation.,Femoral angiography revealed that the entry point was above the bifurcation of the right common femoral artery and I have performed this as Perclose hemostasis.,CONCLUSIONS,1. Normal left ventricular size and function. Ejection fraction is 65% to 70%. No MR.,2. Successful angioplasty and stenting of the subtotally closed mid RCA. This was hard, organized thrombus, very difficult to penetrate. I have deployed two overlapping 4.0 x15 mm excised and with excellent angiographic result. The RCA is dominant.,3. No moderate disease in the distal left main. Moderate disease in the ostium of the left circumflex artery. Mild disease in the proximal LAD.,PLAN: , Recommend smoking cessation. Continue aspirin lifelong and continue Plavix for at least 12 months. | surgery, acute coronary syndrome, circumflex artery, ventricular catheterization, ventricular angiography, angioplasty, coronary artery, coronary angiography, arthrectomy, femoral angiography, perclose hemostasis, selective coronary angiography, angiographic stenosis, rca, coronary, catheterization, artery, angiography, hemostasis, wire, lad, femoral, angiographic, stenting, proximal, |
1,263 | Adenotonsillectomy, primary, patient under age 12. | Surgery | Adenotonsillectomy | PREOPERATIVE DIAGNOSIS: , Chronic hypertrophic adenotonsillitis.,POSTOPERATIVE DIAGNOSIS: , Chronic hypertrophic adenotonsillitis.,OPERATIVE PROCEDURE:, Adenotonsillectomy, primary, patient under age 12.,ANESTHESIA: , General endotracheal anesthesia.,PROCEDURE IN DETAIL: , This patient was brought from the holding area and did receive preoperative antibiotics of Cleocin as well as IV Decadron. She was placed supine on the operating room table. General endotracheal anesthesia was induced without difficulty. In the holding area, her allergies were reviewed. It is unclear whether she is actually allergic to penicillin. Codeine caused her to be excitable, but she did not actually have an allergic reaction to codeine. She might be allergic to BACTRIM and SULFA. After positioning a small shoulder roll and draping sterilely, McIvor mouthgag, #3 blade was inserted and suspended from the Mayo stand. There was no bifid uvula or submucous cleft. She had 3+ cryptic tonsils with significant debris in the tonsillar crypts. Injection at each peritonsillar area with 0.25% with Marcaine with 1:200,000 Epinephrine, approximately 1.5 mL total volume. The left superior tonsillar pole was then grasped with curved Allis forceps. _______ incision and dissection in the tonsillar capsule and hemostasis and removal of the tonsil was obtained with Coblation Evac Xtra Wand on 7/3. Mouthgag was released, reopened, no bleeding was seen. The right tonsil was then removed in the same fashion. The mouthgag released, reopened, and no bleeding was seen. Small red rubber catheter in the nasal passage was used to retract the soft palate. She had mild-to-moderate adenoidal tissue residual. It was removed with Coblation Evac Xtra gently curved Wand on 9/5. Red rubber catheter was then removed. Mouthgag was again released, reopened, no bleeding was seen. Orogastric suction carried out with only scant clear stomach contents. Mouthgag was then removed. Teeth and lips were inspected and were in their preoperative condition. The patient then awakened, extubated, and taken to recovery room in good condition.,TOTAL BLOOD LOSS FROM TONSILLECTOMY: , Less than 2 mL.,TOTAL BLOOD LOSS FROM ADENOIDECTOMY: , Less than 2 mL.,COMPLICATIONS: , No intraoperative events or complications occurred.,PLAN:, Family will be counseled postoperatively. Postoperatively, the patient will be on Zithromax oral suspension 500 mg daily for 5 to 7 days, Lortab Elixir for pain. _______ and promethazine if needed for nausea and vomiting. | surgery, hypertrophic adenotonsillitis, adenotonsillitis, endotracheal anesthesia, coblation evac xtra wand, lortab elixir, red rubber catheter, total blood loss, adenotonsillectomy, forceps, mouthgag, |
1,264 | Adenoidectomy. Adenoid hypertrophy. The McIvor mouth gag was placed in the oral cavity and the tongue depressor applied. | Surgery | Adenoidectomy - 1 | PREOPERATIVE DIAGNOSIS: , Adenoid hypertrophy.,POSTOPERATIVE DIAGNOSIS: , Adenoid hypertrophy.,PROCEDURE PERFORMED: ,Adenoidectomy.,ANESTHESIA: , General endotracheal.,DESCRIPTION OF PROCEDURE: , The patient was taken to the operating room and prepped and draped in the usual fashion after induction of general endotracheal anesthesia. The McIvor mouth gag was placed in the oral cavity and the tongue depressor applied. Two #12-French red rubber Robinson catheters were placed, 1 in each nasal passage, and brought out through the oral cavity and clamped over a dental gauze roll placed on the upper lip to provide soft palate retraction. The nasopharynx was inspected with the laryngeal mirror. Serial passages of the curettes were utilized to remove the nasopharyngeal tissue, following which the nasopharynx was packed with 2 cherry gauze sponges coated in a solution of 0.25% Neo-Synephrine and tannic acid powder.,Attention was then redirected to the oropharynx. The McIvor was reopened, packs removed, and the bleeding was controlled with the suction Bovie unit. The catheters were removed, and the nasal passages and oropharynx were suctioned free of debris. The McIvor was then removed, and the procedure was terminated.,The patient tolerated the procedure well and left the operating room in good condition. | surgery, palate, nasal passage, mcivor mouth gag, oral cavity, nasal, nasopharynx, oropharynx, hypertrophy, oral, cavity, mcivor, tongue, adenoidectomy |
1,265 | The Ahmed shunt was primed and placed in the superior temporal quadrant and it was sutured in place with two 8-0 nylon sutures. The knots were trimmed. | Surgery | Ahmed Shunt Placement | PROCEDURE IN DETAIL: ,While in the holding area, the patient received a peripheral IV from the nursing staff. In addition, pilocarpine 1% was placed into the operative eye, two times, separated by 10 minutes. The patient was wheeled to the operating suite where the anesthesia team established peripheral monitoring lines. Through the IV, the patient received IV sedation in the form of propofol and once somnolent from this, a retrobulbar block was administrated consisting of 2% Xylocaine plain. Approximately 3 mL were administered. The patient then underwent a Betadine prep with respect to the face, lens, lashes, and eye. During the draping process, care was taken to isolate the lashes. A Vicryl traction suture was placed through the superior cornea and the eye was reflected downward to expose the superior temporal conjunctiva. Approximately 8 to 10 mm posterior to limbus, the conjunctiva was incised and dissected forward to the limbus. Blunt dissection was carried out in the superotemporal quadrant. Next, a 2 x 3-mm scleral flap was outlined that was one-half scleral depth in thickness. This flap was cut forward to clear cornea using a crescent blade. The Ahmed shunt was then primed and placed in the superior temporal quadrant and it was sutured in place with two 8-0 nylon sutures. The knots were trimmed. The tube was then cut to an appropriate length to enter the anterior chamber. The anterior chamber was then entered after a paracentesis wound had been made temporally. A trabeculectomy was done and then the tube was threaded through the trabeculectomy site. The tube was sutured in place with a multi-wrapped 8-0 nylon suture. The scleral flap was then sutured in place with two 10-0 nylon sutures. The knots were trimmed, rotated and buried. A scleral patch was then placed of an appropriate size over the two. It was sutured in place with interrupted 8-0 nylon sutures. The knots were trimmed. The overlying conjunctiva was then closed with a running 8-0 Vicryl suture with a BV needle. The anterior chamber was filled with Viscoat to keep it deep as the eye was somewhat soft. A good flow was established with irrigation into the anterior chamber. Homatropine, Econopred, and Vigamox drops were placed into the eye. A patch and shield were placed over the eye after removing the draping and the speculum. The patient tolerated the procedure well. He was taken to the recovery in good condition. He will be seen in followup in the office tomorrow. | surgery, cornea, ahmed shunt, nylon sutures, trabeculectomy, conjunctiva, chamberNOTE,: Thesetranscribed medical transcription sample reports and examples are provided by various users andare for reference purpose only. MTHelpLine does not certify accuracy and quality of sample reports.These transcribed medical transcription sample reports may include some uncommon or unusual formats;this would be due to the preference of the dictating physician. All names and dates have beenchanged (or removed) to keep confidentiality. Any resemblance of any type of name or date orplace or anything else to real world is purely incidental., |
1,266 | Laparoscopic hand-assisted left adrenalectomy and umbilical hernia repair. Patient with a 5.5-cm diameter nonfunctioning mass in his right adrenal. | Surgery | Adrenalectomy & Umbilical Hernia Repair | PREOPERATIVE DIAGNOSES,1. Adrenal mass, right sided.,2. Umbilical hernia.,POSTOPERATIVE DIAGNOSES,1. Adrenal mass, right sided.,2. Umbilical hernia.,OPERATION PERFORMED: , Laparoscopic hand-assisted left adrenalectomy and umbilical hernia repair.,ANESTHESIA: ,General.,CLINICAL NOTE: , This is a 52-year-old inmate with a 5.5 cm diameter nonfunctioning mass in his right adrenal. Procedure was explained including risks of infection, bleeding, possibility of transfusion, possibility of further treatments being required. Alternative of fully laparoscopic are open surgery or watching the lesion.,DESCRIPTION OF OPERATION: ,In the right flank-up position, table was flexed. He had a Foley catheter in place. Incision was made from just above the umbilicus, about 5.5 cm in diameter. The umbilical hernia was taken down. An 11 mm trocar was placed in the midline, superior to the GelPort and a 5 mm trocar placed in the midaxillary line below the costal margin. A liver retractor was placed to this.,The colon was reflected medially by incising the white line of Toldt. The liver attachments to the adrenal kidney were divided and the liver was reflected superiorly. The vena cava was identified. The main renal vein was identified. Coming superior to the main renal vein, staying right on the vena cava, all small vessels were clipped and then divided. Coming along the superior pole of the kidney, the tumor was dissected free from top of the kidney with clips and Bovie. The harmonic scalpel was utilized superiorly and laterally. Posterior attachments were divided between clips and once the whole adrenal was mobilized, the adrenal vein and one large adrenal artery were noted, doubly clipped, and divided. Specimen was placed in a collection bag, removed intact.,Hemostasis was excellent.,The umbilical hernia had been completely taken down. The edges were freshened up. Vicryl #1 was utilized to close the incision and 2-0 Vicryl was used to close the fascia of the trocar.,Skin closed with clips.,He tolerated the procedure well. All sponge and instrument counts were correct. Estimated blood loss less than 100 mL.,The patient was awakened, extubated, and returned to recovery room in satisfactory condition. | surgery, adrenalectomy, laparoscopic hand-assisted, umbilical hernia repair, vena cava, renal vein, hernia repair, laparoscopic, umbilical, hernia, |
1,267 | Left heart catheterization, bilateral selective coronary angiography, left ventriculography, and right heart catheterization. Positive nuclear stress test involving reversible ischemia of the lateral wall and the anterior wall consistent with left anterior descending artery lesion. | Surgery | Angiography & Catheterization | PROCEDURES PERFORMED:,1. Left heart catheterization.,2. Bilateral selective coronary angiography.,3. Left ventriculography.,4. Right heart catheterization.,INDICATION: , Positive nuclear stress test involving reversible ischemia of the lateral wall and the anterior wall consistent with left anterior descending artery lesion.,PROCEDURE: , After risks, benefits, and alternatives of the above-mentioned procedure were explained in detail to the patient, informed consent was obtained both verbally and in writing. The patient was taken to cardiac catheterization suite where the right femoral region was prepped and draped in the usual sterile fashion. 1% lidocaine solution was used to infiltrate the skin overlying the right femoral artery and vein. Once adequate anesthesia has been obtained, a thin-walled #18 gauge Argon needle was used to cannulate the right femoral artery. A steel guidewire was inserted through the needle into the vascular lumen without resistance. A small nick was then made in the skin. The pressure was held. The needle was removed over the guidewire. Next, a #6 French arterial sheath was then advanced over the guidewire into the vascular lumen without resistance. The guidewire and dilator were then removed. The sheath was flushed. Next, an angulated pigtail catheter was advanced to the level of the ascending aorta under the direct fluoroscopy visualization with the use of a guidewire. The catheter was then guided into the left ventricle. The guidewire and dilator were then removed. The catheter was then flushed. LVEDP was measured and found to be favorable for a left ventriculogram. The left ventriculogram was performed in the RAO position with a single power injection of nonionic contrast material. LVEDP was then remeasured. Pullback was performed, which failed to reveal an LVAO gradient. The catheter was then removed. Next, a Judkins left #4 catheter was advanced to the level of the ascending aorta under direct fluoroscopic visualization with the use of a guidewire. The guidewire was removed. The catheter was connected to the manifold and flushed. The ostium of the left main coronary was unable to be engaged with this catheter. Thus it was removed over a guidewire. Next, a Judkins left #5 catheter was advanced to the level of the ascending aorta under direct fluoroscopic visualization with the use of a guidewire. The guidewire was removed. The catheter was connected to the manifold and flushed. Left main coronary artery was then engaged. Using hand injections of nonionic contrast material, the left coronary system was evaluated in several different views. The catheter was then removed from the ostium of the left main coronary artery and was removed over a guidewire. Next, a Judkins right #4 catheter was then advanced to the level of the ascending aorta under direct fluoroscopic visualization with the use of a guidewire. The guidewire was removed. The catheter was connected to the manifold and flushed. Using hand injections of nonionic contrast material, the right coronary system was evaluated in several different views. The catheter was then removed from the ostium of the right coronary artery and then removed. The sheath was then flushed. Because the patient did have high left ventricular end-diastolic pressures, it was determined that the patient wound need a right heart catheterization. Thus an #18 gauge Argon needle was used to cannulate the right femoral vein. A steel guidewire was inserted through the needle into the vascular lumen. The needle was removed over the guidewire. Next, an #8 French venous sheath was advanced over the guidewire into lumen without resistance. The guidewire and dilator were then removed. The sheath was then flushed. Next, a Swan-Ganz catheter was advanced to the level of 20 cm. The balloon was inflated. Under fluoroscopic visualization, the catheter was guided into the right atrium, right ventricle, and into the pulmonary artery wedge position. Hemodynamics were measured along the way. PA saturation, right atrial saturation, femoral artery saturation were all obtained. Once adequate study has been performed, the catheter was then removed. Both sheaths were flushed and found fine. The patient was returned to the cardiac catheterization holding area in stable satisfactory condition.,FINDINGS:,LEFT VENTRICULOGRAM: ,There is no evidence of any wall motion abnormalities with estimated ejection fraction of 60%. Left ventricular end-diastolic pressure was 38 mmHg preinjection and 40 mmHg postinjection. There is no LVAO. There is no mitral regurgitation. There is a trileaflet aortic valve noted.,LEFT MAIN CORONARY ARTERY: ,The left main is a moderate caliber vessel, which bifurcates into the left anterior descending and circumflex arteries. There is no evidence of any hemodynamically significant stenosis.,LEFT ANTERIOR DESCENDING: , The LAD is a moderate caliber vessel, which traverses through the intraventricular groove and reaches the apex of the heart. There is a proximal 60% to 70% stenotic lesion. There was also a mid 70% to 80% stenotic lesion at the takeoff of the first and second diagonal branches.,CIRCUMFLEX ARTERY: ,The circumflex is a moderate caliber vessel, which traverses through the atrioventricular groove. There is a mid 60% to 70% stenotic lesion followed by a second mid 90% stenotic lesion. The first obtuse marginal branch is small and the second obtuse marginal branch is large without any evidence of critical disease. The third obtuse marginal branch is also small.,RIGHT CORONARY ARTERY: ,The RCA is a moderate caliber vessel with minor luminal irregularities throughout. There is no evidence of any critical disease. The right coronary artery is the dominant right coronary vessel.,RIGHT HEART FINDINGS: ,Pulmonary artery pressure equals 61/23 with a mean of 44. Pulmonary artery wedge pressure equals 32. Right ventricle pressure equals 65/24. The right atrial pressure equals to 22. Cardiac output by Fick is 4.9. Cardiac index by Fick is 2.3. Hand calculated cardiac output equals 7.8. Hand calculated cardiac index equals 3.7. On 2 liters nasal cannula, pulmonary artery saturation equals 77.8%. Femoral artery saturation equals 99.1%. Pulse oximetry is 99%. Right atrial saturation is 76.3%. Systemic blood pressure is 166/58. Body surface area equals 2.12. Hemoglobin equals 12.6.,IMPRESSION:,1. Two-vessel coronary artery disease with a complex left anterior descending arterial lesion as well as circumflex disease.,2. Normal left ventricular function with an estimated ejection fraction of 60%.,3. Biventricular overload.,4. Moderate pulmonary hypertension.,5. There is no evidence of shunt.,PLAN:,1. The patient will be admitted for IV diuresis in light of the biventricular overload.,2. The findings of the heart catheterization were discussed in detail with the patient and the patient's family. There is some concern with the patient's two-vessel coronary artery disease in light of the patient's diabetic history. We will obtain a surgical evaluation for the possibility of a coronary artery bypass grafting.,3. The patient will remain on aggressive medical regimen including ACE inhibitor, aspirin, Plavix, and nitrate.,4. The patient will need to undergo aggressive risk factor modification including weight loss and diet control.,5. The patient will have an Internal Medicine evaluation regarding the patient's diabetic history. | null |
1,268 | Lower extremity angiogram, superficial femoral artery laser atherectomy and percutaneous transluminal balloon angioplasty, external iliac artery angioplasty and stent placement, and completion angiogram. | Surgery | Angiogram & Angioplasty | PREOPERATIVE DIAGNOSES:,1. Left superficial femoral artery subtotal stenosis.,2. Arterial insufficiency, left lower extremity.,POSTOPERATIVE DIAGNOSES:,1. Left superficial femoral artery subtotal stenosis.,2. Arterial insufficiency, left lower extremity.,OPERATIONS PERFORMED:,1. Left lower extremity angiogram.,2. Left superficial femoral artery laser atherectomy.,3. Left superficial femoral artery percutaneous transluminal balloon angioplasty. ,4. Left external iliac artery angioplasty.,5. Left external iliac artery stent placement.,6. Completion angiogram.,FINDINGS: ,This patient was brought to the OR with a non-severe stenosis of the proximal left superficial femoral artery in the upper one-third of his thigh. He is also known to have severe calcific disease involving the entire left external iliac system as well as the common femoral and deep femoral arteries.,Our initial plan today was to perform an atherectomy with angioplasty and stenting of the left superficial femoral artery as necessary. However, whenever we started the procedure, it became clear that there was a severe stenosis of the left superficial femoral artery at its takeoff from the left common femoral artery. The area was severely calcified including the external iliac artery extending up underneath the left inguinal ligament. Indeed, this ultimately was dissected due to manipulation of sheath catheters and sheath through the area. Ultimately, this wound up being a much more complex case than initially anticipated.,Because of the above, we ultimately performed a laser atherectomy of the left superficial femoral artery, which then had to be angioplastied to obtain a satisfactory result. The completion angiogram showed that there was a dissection of the left external iliac artery, which precluded flow down into the left lower extremity. We then had to come up and perform angioplasty and stenting of the left external iliac artery as well as aggressively dilating the takeoff of the less superficial femoral artery from the common femoral artery.,The left superficial femoral artery was dilated with a 6-mm balloon.,The left external iliac artery and common femoral arteries were dilated with an 8-mm balloon.,A 2.5-mm ClearPath laser probe was used to initially arthrectomize and debulk the superficial femoral artery starting at its takeoff from the common femoral artery and extending down to the tight stenotic area in the upper one-third of the thigh. After the laser atherectomy was performed, the area still did not look good and so an angioplasty was then done, which looked good; however, as noted above, after we had dealt with the superficial femoral artery, we then had proximal inflow problems, which had to be dealt by angioplasty and stenting.,The patient had good dorsalis pedis pulses bilaterally upon completion.,The right common femoral artery was used for access in an up-and-over technique.,PROCEDURE: , With the patient in the supine position under general anesthesia, the abdomen and lower extremities were prepped and draped in the sterile fashion.,The right common femoral artery was punctured percutaneously, and a #5-French sheath was initially placed. We used a pigtail catheter to go up and over the aortic bifurcation and placed a stiff Amplatz guidewire down into the left common femoral artery. We then heparinized the patient and placed a #7-French Raby sheath over the Amplatz wire. A selective left lower extremity angiogram was then done with the above-noted findings.,We then used a ClearPath 2.5-mm laser probe to laser the proximal superficial femoral artery. Because of the findings as noted above, this became more involved than initially hoped for. Once the laser atherectomy had been completed, the vessel still did not look good, so we used a 6-mm balloon to thoroughly dilate the area. Once that had been done, it looked good and we performed what we felt would be a completion angiogram only to find out that we had a more proximal problem precluding flow down into the left femoral artery.,Once that was discovered, we then had to proceed with angioplasty and stenting of the left external iliac artery right down to the acetabular level.,Once we had dealt with our run-on problems, we then did another completion angiogram, which showed a good flow through the entire area and down into the left lower extremity.,Following completion of the above, all wires, sheaths, and catheters were removed from the right common femoral artery. Firm pressure was held over the puncture site for 20 minutes followed by application of a sterile Coverlet dressing and a firm pressure dressing.,The patient tolerated the procedure well throughout. He had good palpable dorsalis pedis pulses bilaterally on completion. He was taken to the recovery room in satisfactory condition. Protamine was given to partially reverse the heparin. | null |
1,269 | Grade 1 endometrial adenocarcinoma and low-grade mesothelioma of the ovary - Omentectomy, pelvic lymph node dissection, and laparoscopy. | Surgery | Adenocarcinoma & Mesothelioma | PREOPERATIVE DIAGNOSES,1. Incomplete surgical staging of recent diagnosis of grade 1 endometrial adenocarcinoma and also low-grade mesothelioma of the ovary.,2. Status post laparoscopic-assisted vaginal hysterectomy with bilateral salpingo-oophorectomy.,POSTOPERATIVE DIAGNOSES,1. Incomplete surgical staging of recent diagnosis of grade 1 endometrial adenocarcinoma and also low-grade mesothelioma of the ovary.,2. Status post laparoscopic-assisted vaginal hysterectomy with bilateral salpingo-oophorectomy.,OPERATIONS PERFORMED,1. Robotic-assisted omentectomy.,2. Robotic-assisted pelvic lymph node dissection.,3. Attempted laparoscopy.,4. Exploratory laparotomy with bilateral pelvic bilateral periaortic lymph node dissection with multiple biopsies.,ANESTHESIA:, General/epidural anesthesia.,ESTIMATED BLOOD LOSS:, 200 mL.,COMPLICATIONS:, None.,FINAL SPONGE AND NEEDLE COUNTS: , Correct, confirmed by x-ray JP drain x1.,INDICATIONS FOR SURGERY: , Mrs. A is a pleasant 66-year-old female who was diagnosed with an unsuspected grade 1 endometrial adenocarcinoma and low-grade mesothelioma of the ovary. The patient is status post laparoscopic-assisted vaginal hysterectomy BSO. The patient was referred to me by Dr. X. Because of the incomplete staging, the patient was advised to undergo a robotic-assisted surgical staging. Risks, benefits, and rationale of these procedures were reviewed. The patient has understanding of these risks and wishes to proceed with the surgery as planned.,INTRAOPERATIVE FINDINGS,1. No evidence of ascites.,2. At the time of the exploratory laparotomy, the diaphragm was well palpated. They were clear. The low attachments were removed. The lesser omentum was unremarkable. The pancreas, spleen, and liver were unremarkable. The gallbladder was unremarkable. The stomach appeared grossly normal. The small bowel was inspected from the ligament which starts to the ileocecal valve. There is no evidence of disease. Paracolic gutter and peritoneum was free. The omentum was grossly normal.,3. In the pelvis, uterus, tubes, and ovaries were absent. There was no evidence seeding along the bladder, pelvic, cul-de-sac, and peritoneum.,4. Retroperitoneally, pelvic lymph nodes were mostly normal; however, at the right aortic, there are nodes. These nodes were extremely fibrotic and they were densely adherent to the anterior wall of the vena cava which precluded me from performing a robotic periaortic lymph node dissection. There was some area that was suspicious right at the low right periaortic lymph node. They were sent for frozen section and they came back as benign. It is unclear to me why did the lymph nodes were quite fibrotic and firm, but we will wait for the pathology report.,PROCEDURE IN DETAIL: , The patient was given IV antibiotics prior to our incision site, sequential compression device was placed as part of the DVT prophylaxis. I have requested an epidural catheter be placed for purpose of the periaortic lymph node dissection. With this in mind, we proceeded as such.,We initially began with the robotic portion of the procedure.,A 1-cm supraumbilical incision made. A Veress needle was inserted without difficulty. Pneumoperitoneum was achieved to the abdominal pressure of 15 mmHg. A 12mm trocar was inserted without difficulty. After completion of this, a 12mm trocar was placed in the left lower quadrant 2 fingerbreadths medial to the anterior superior iliac spine under direct laparoscopic visualization. After completion of this, a laparoscope was then placed in the left lower quadrant port to assist in the placement of the remainder of the da Vinci ports. Two 8-mm ports were placed in the right upper quadrant 8 cm apart while one 8-mm port was placed in the left upper quadrant 8 cm apart. After completion of this, the patient was placed in steep Trendelenburg position. The robotic system was then docked and after docking the robotic system, the instrumentation was inserted under direct laparoscopic visualization to ensure that there was no injury to the abdominal contents. Once this was completed, the robotic camera was then docked. We then proceeded with our daVinci portion of the procedure.,I then proceeded now with the omentectomy. The omentum was taken off the transverse colon with the harmonic scalpel. The entire omentum was removed and placed in the pelvis. After completion of this, I then proceeded now with the pelvic lymph node dissection.,An incision was made parallel along the peritoneum overlying the psoas muscle. All the lymph node bearing tissues along the external iliac artery and vein were subsequently skeletonized off the vessels and resected. The lymph node bearing tissues interposed between the external iliac vein and psoas muscle were mobilized into the obturator fossa and subsequently removed off the accessory obturator vein, artery and nerve. In the process of removing the lymphoid tissues, the genitofemoral nerve along with the accessory obturator vein, obturator artery and nerve were all preserved. The lymphoid tissues interposed between the external iliac vein and psoas muscle along with the common iliac vessels were also subsequently removed. The lymph node bearing tissues bifurcating at the hypogastric and the external iliac vein were likewise removed in addition to the hypogastric lymph nodes. All the lymph node tissues were placed in an Endobag and removed and submitted as pelvic nodes on the right side and subsequently the left side. Boundaries of the pelvic nodal dissection distally were the external circumflex iliac vein, laterally the psoas muscle along with the obturator internus fascia, medially the superior vesical artery along with the ureter, and inferiorly below the obturator nerve.,At this point in time, we have attempted the periaortic lymph node dissection. I did open up the peritoneum overlying the bifurcation of the aorta. This peritoneum was incised up to the level of the duodenal recess. It was at this point in time that the periaortic lymph node dissection was extremely difficult. I was unable to get a tissue plane as the lymph nodes were apparently very fibrotic. I was concerned that I would tear off the anterior wall of the cava in the process of trying to perform the right periaortic lymph node. For this reason, I aborted the robotic procedure or in after nearly attempting for about an hour and a half for the periaortic lymph nodes. Once this was unsuccessful, the robotic system was then dedocked. I then placed additional ports. A 5-mm port was placed in the suprapubic region, two fingerbreadths above. A right lower quadrant 12-mm port was placed. After completion of this, I had attempted to see whether we could do the remainder of the periaortic lymph node dissection via laparoscopically. Despite an attempt for a nearly 35 minutes, I was not able to get adequate exposure. The small bowel kept on falling in the operative field which precluded us to perform the procedure safely. For this reason, I converted to an open procedure.,A midline incision was made from suprapubic bone and extended above the umbilicus. The abdominal cavity was entered without injuring the bell. After entering the abdomen, omentum was removed. Ray-Tec sponges were removed. We covered for the Ray-Tec sponges. After completion of this, Thompson retractor was placed. The patient was placed in C-Trendelenburg position. The bowel was packed cephalad. Retroperitoneum space was entered right and left ureters were identified. I then meticulously resected the lymphoid-bearing tissues anterior and lateral to the cava. This dissection was quite difficult as the lymph nodes were extremely fibrotic and adherent to the caval wall. I was able to freed up these lymph nodes without injuring of the cava. Likewise, the left periaortic lymph node dissection was carried out from the level of the bifurcation to 1 cm above the IMA. All the periaortic lymph node dissection was then carried out. After completion of this, I then took washings. Random biopsies were obtained of the cul-de-sac and right and left pelvic side wall along with the right and left paracolic gutter. After completion of this, the patient appears to have tolerated the procedure well. There was no obvious gross disease. The bowel was inspected meticulously to ensure that there was no evidence of injury. Once this was completed, the bowel was placed back to its normal position. Several film solutions were placed. We counted for sponges, needles, and instruments. Once this was counted for, the fascia was then closed with #2 Vicryl suture in a mass closure fashion. The subcutaneous route was copiously irrigated with water. The JP drain was brought to the right lower quadrant incision. All the incision ports were then closed with 3-0 Monocryl suture. Likewise, the midline incision was closed with 3-0 Monocryl sutures.,At the conclusion of the procedure, there was no obvious gross disease left., | null |
1,270 | Adenoidectomy procedure | Surgery | Adenoidectomy | ADENOIDECTOMY,PROCEDURE:, The patient was brought into the operating room suite, anesthesia administered via endotracheal tube. Following this the patient was draped in standard fashion. The Crowe-Davis mouth gag was inserted in the oral cavity. The palate and tonsils were inspected, the palate was suspended with a red rubber catheter passed through the right nostril. Following this, the mirror was used to visualize the adenoid pad and an adenoid curet was seated against the vomer. The adenoid pad was removed without difficulty. The nasopharynx was packed. Following this, the nasopharynx was unpacked, several discrete bleeding sites were gently coagulated with electrocautery and the nasopharynx and oral cavity were irrigated. The Crowe-Davis was released.,The patient tolerated the procedure without difficulty and was in stable condition on transfer to recovery. | surgery, adenoidectomy, crowe-davis, adenoid pad, electrocautery, endotracheal tube, gently coagulated, mouth gag, nasopharynx, oral cavity, red rubber catheter, vomer, palate, tonsilsNOTE,: Thesetranscribed medical transcription sample reports and examples are provided by various users andare for reference purpose only. MTHelpLine does not certify accuracy and quality of sample reports.These transcribed medical transcription sample reports may include some uncommon or unusual formats;this would be due to the preference of the dictating physician. All names and dates have beenchanged (or removed) to keep confidentiality. Any resemblance of any type of name or date orplace or anything else to real world is purely incidental., |
1,271 | Adenotonsillectomy. Adenotonsillitis with hypertrophy. The patient is a very nice patient with adenotonsillitis with hypertrophy and obstructive symptoms. Adenotonsillectomy is indicated. | Surgery | Adenotonsillectomy - 2 | POSTOPERATIVE DIAGNOSIS: Adenotonsillitis with hypertrophy.,OPERATION PERFORMED: Adenotonsillectomy.,ANESTHESIA: General endotracheal.,INDICATIONS: The patient is a very nice patient with adenotonsillitis with hypertrophy and obstructive symptoms. Adenotonsillectomy is indicated.,DESCRIPTION OF PROCEDURE: The patient was placed on the operating room table in the supine position. After adequate general endotracheal anesthesia was administered, table was turned and shoulder roll was placed on the shoulders and face was draped in clean fashion. A McIvor mouth gag was applied. The tongue was retracted anteriorly and the McIvor was gently suspended from a Mayo stand. A red rubber Robinson catheter was inserted through the left naris and the soft palate was retracted superiorly. The adenoids were removed with suction electrocautery under mere visualization. The left tonsil was grasped with a curved Allis forceps, retracted medially and the anterior tonsillar pillar was incised with Bovie electrocautery. The tonsil was removed from the superior and inferior pole using Bovie electrocautery in its entirety in the subcapsular fashion. The right tonsil was grasped in the similar fashion and retracted medially and the anterior tonsillar pillar was incised with Bovie electrocautery. The tonsil was removed from the superior pole and inferior pole using Bovie electrocautery in its entirety in the subcapsular fashion. The inferior, middle and superior pole vessels were further cauterized with suction electrocautery. Copious saline irrigation of the oral cavity was then performed. There was no further identifiable bleeding at the termination of the procedure. The estimated blood loss was less than 10 mL. The patient was extubated in the operating room, brought to the recovery room in satisfactory condition. There were no intraoperative complications. | surgery, hypertrophy, adenotonsillitis, tonsillar pillar, bovie electrocautery, adenotonsillectomyNOTE,: Thesetranscribed medical transcription sample reports and examples are provided by various users andare for reference purpose only. MTHelpLine does not certify accuracy and quality of sample reports.These transcribed medical transcription sample reports may include some uncommon or unusual formats;this would be due to the preference of the dictating physician. All names and dates have beenchanged (or removed) to keep confidentiality. Any resemblance of any type of name or date orplace or anything else to real world is purely incidental. |
1,272 | Adenotonsillectomy. Recurrent tonsillitis. The adenoid bed was examined and was moderately hypertrophied. Adenoid curettes were used to remove this tissue and packs placed. | Surgery | Adenotonsillectomy - 1 | PREOPERATIVE DIAGNOSIS: , Recurrent tonsillitis.,POSTOPERATIVE DIAGNOSIS: , Recurrent tonsillitis.,PROCEDURE: ,Adenotonsillectomy.,COMPLICATIONS:, None.,PROCEDURE DETAILS:, The patient was brought to the operating room and, under general endotracheal anesthesia in supine position, the table turned and a McIvor mouthgag placed. The adenoid bed was examined and was moderately hypertrophied. Adenoid curettes were used to remove this tissue and packs placed. Next, the right tonsil was grasped with a curved Allis and, using the gold laser, the anterior tonsillar pillar incised and, with this laser, dissection carried from the superior pole to the inferior pole and removed off the tonsillar muscular bed. A similar procedure was performed on the contralateral tonsil. Following meticulous hemostasis, saline was used to irrigate and no further bleeding noted. The patient was then allowed to awaken and was brought to the recovery room in stable condition. | surgery, curved allis, tonsillitis, hypertrophied, curettes, tonsillar, adenoid, adenotonsillectomy, |
1,273 | Bilateral open Achilles lengthening with placement of short leg walking cast. | Surgery | Achilles Lengthening | PREOPERATIVE DIAGNOSIS: , Idiopathic toe walker.,POSTOPERATIVE DIAGNOSIS: , Idiopathic toe walker.,PROCEDURE: , Bilateral open Achilles lengthening with placement of short leg walking cast.,ANESTHESIA: , Surgery performed under general anesthesia. A total of 10 mL of 0.5% Marcaine local anesthetic was used.,COMPLICATIONS: ,No intraoperative complications.,DRAINS: , None.,SPECIMENS: , None.,TOURNIQUET TIME: ,On the left side was 30 minutes, on the right was 21 minutes.,HISTORY AND PHYSICAL:, The patient is a 10-year-old boy who has been a toe walker since he started ambulating at about a year. The patient had some mild hamstring tightness with his popliteal angle of approximately 20 degrees bilaterally. He does not walk with a crouched gait but does toe walk. Given his tightness, surgery versus observation was recommended to the family. Family however wanted to correct his toe walking. Surgery was then discussed. Risks of surgery include risks of anesthesia, infection, bleeding, changes in sensation and motion of the extremities, failure to resolve toe walking, possible stiffness, cast, and cast problems. All questions were answered and parents agreed to above surgical plan.,PROCEDURE IN DETAIL: , The patient was taken to the operating room and placed supine on the operating table General anesthesia was then administered. The patient received Ancef preoperatively. The patient was then subsequently placed prone with all bony prominences padded. Two bilateral nonsterile tourniquets were placed on each thigh. Both extremities were then prepped and draped in a standard surgical fashion. We turned our attention first towards the left side. A planned incision of 1 cm medial to the Achilles tendon was marked on the skin. The extremity was wrapped in Esmarch prior to inflation of tourniquet to 250 mmHg. Incision was then made and carried down through subcutaneous fat down to the tendon sheath. Achilles tendon was identified and Z-lengthening was done with the medial distal half cut. Once Z-lengthening was completed proximally, the length of the Achilles tendon was then checked. This was trimmed to obtain an end-on-end repair with 0 Ethibond suture. This was also oversewn. Wound was then irrigated. Achilles tendon sheath was reapproximated using 2-0 Vicryl as well as the subcutaneous fat. The skin was closed using 4-0 Monocryl. Once the wound was cleaned and dried and dressed with Steri-Strips and Xeroform, the area was injected with 0.5% Marcaine. It was then dressed with 4 x 4 and Webril. Tourniquet was released at 30 minutes. The same procedure was repeated on the right side with tourniquet time of 21 minutes. While the patient was still prone, two short-leg walking casts were then placed. The patient tolerated the procedure well and was subsequently flipped supine on to hospital gurney and taken to PACU in stable condition.,POSTOPERATIVE PLAN: ,The patient will be discharged on the day of surgery. He may weightbear as tolerated in his cast, which he will have for about 4 to 6 weeks. He is to follow up in approximately 10 days for recheck as well as prescription for intended AFOs, which he will need up to 6 months. The patient may or may not need physical therapy while his Achilles lengthenings are healing. The patient is not to participate in any PE for at least 6 months. The patient is given Tylenol No. 3 for pain. | surgery, toe walker, achilles lengthening, idiopathic toe walker, short leg walking, subcutaneous fat, tendon sheath, leg walking, achilles tendon, toe, tourniquet, tendon, intraoperative, |
1,274 | Adenoidectomy and tonsillectomy and lingual frenulectomy. Chronic adenotonsillitis and ankyloglossia. | Surgery | Adenoidectomy & Tonsillectomy & Lingual Frenulectomy | PREOPERATIVE DIAGNOSES:,1. Chronic adenotonsillitis.,2. Ankyloglossia,POSTOPERATIVE DIAGNOSES:,1. Chronic adenotonsillitis.,2. Ankyloglossia,PROCEDURE PERFORMED:,1. Adenoidectomy and tonsillectomy.,2. Lingual frenulectomy.,ANESTHESIA: , General endotracheal.,FINDINGS/SPECIMEN:, Tonsil and adenoid tissue.,COMPLICATIONS: , None.,CONDITION: ,The patient is stable and tolerated the procedure well, and sent to PACU.,HISTORY OF PRESENT ILLNESS: , This is a 3-year-old child with a history of adenotonsillitis.,PROCEDURE: , The patient was prepped and draped in the usual sterile fashion. A curved hemostat was used to grasp the lingual frenulum. The stat was removed and Metzenbaum scissors were used to free the lingual frenulum. Cautery was used to allow hemostasis. The patient was then turned. McIvor mouth gag was inserted. Tonsils and adenoids were exposed. The patient's right tonsil was first grasped with a curved hemostat. Needle tip cautery was used to free the superior pole of tonsil. The tonsil was then grasped in medial superior aspect with a straight hemostat. The tonsil fascia planes were identified with Bovie dissection along the plane. The tonsil was freed from anterior pillar and posterior pillar. Amputation occurred along the same plane as the patient's tongue. Suction cautery was then used to allow for hemostasis. The patient's adenoids were then viewed with an adenoid mirror. An adenoid curet was used to remove the patient's adenoid tissue. Specimen sent. Suction cautery was used to allow for hemostasis. Superior pole of left tonsil was then grasped with a curved hemostat. Superior pole was freed using needle tip Bovie dissection. Beginning with 15 desiccate, after superior pole was free, Bovie was switched to 15 fulgurate, and the tonsil was stripped from anterior and posterior pillars. The tonsil was then amputated at the same plane as tongue base. Hemostasis was achieved with using suction cautery. Mouth gag was removed. Dual position and occlusion were tested. The patient was extubated and tolerated the procedure well and sent back to PACU. | surgery, adenotonsillitis, ankyloglossia, adenoidectomy, tonsillectomy, frenulectomy, tonsil, adenoid tissue, metzenbaum scissors, lingual frenulectomy, chronic adenotonsillitis, curved hemostat, suction cautery, hemostat, hemostasis, lingual, cautery |
1,275 | Achilles tendon rupture, left lower extremity. Primary repair left Achilles tendon. The patient was stepping off a hilo at work when he felt a sudden pop in the posterior aspect of his left leg. The patient was placed in posterior splint and followed up at ABC orthopedics for further care. | Surgery | Achilles Tendon Repair | PREOPERATIVE DIAGNOSIS: , Achilles tendon rupture, left lower extremity.,POSTOPERATIVE DIAGNOSIS: , Achilles tendon rupture, left lower extremity.,PROCEDURE PERFORMED:, Primary repair left Achilles tendon.,ANESTHESIA: , General.,COMPLICATIONS: , None.,ESTIMATED BLOOD LOSS: , Minimal.,TOTAL TOURNIQUET TIME: ,40 minutes at 325 mmHg.,POSITION:, Prone.,HISTORY OF PRESENT ILLNESS: ,The patient is a 26-year-old African-American male who states that he was stepping off a hilo at work when he felt a sudden pop in the posterior aspect of his left leg. The patient was placed in posterior splint and followed up at ABC orthopedics for further care.,PROCEDURE:, After all potential complications, risks, as well as anticipated benefits of the above-named procedure were discussed at length with the patient, informed consent was obtained. The operative extremity was then confirmed with the patient, the operative surgeon, Department Of Anesthesia, and nursing staff. While in this hospital, the Department Of Anesthesia administered general anesthetic to the patient. The patient was then transferred to the operative table and placed in the prone position. All bony prominences were well padded at this time.,A nonsterile tourniquet was placed on the left upper thigh of the patient, but not inflated at this time. Left lower extremity was sterilely prepped and draped in the usual sterile fashion. Once this was done, the left lower extremity was elevated and exsanguinated using an Esmarch and the tourniquet was inflated to 325 mmHg and kept up for a total of 40 minutes. After all bony and soft tissue land marks were identified, a 6 cm longitudinal incision was made paramedial to the Achilles tendon from its insertion proximal. Careful dissection was then taken down to the level of the peritenon. Once this was reached, full thickness flaps were performed medially and laterally. Next, retractor was placed. All neurovascular structures were protected. A longitudinal incision was then made in the peritenon and opened up exposing the tendon. There was noted to be complete rupture of the tendon approximately 4 cm proximal to the insertion point. The plantar tendon was noted to be intact. The tendon was debrided at this time of hematoma as well as frayed tendon. Wound was copiously irrigated and dried. Most of the ankle appeared that there was sufficient tendon links in order to do a primary repair. Next #0 PDS on a taper needle was selected and a Krackow stitch was then performed. Two sutures were then used and tied individually ________ from the tendon. The tendon came together very well and with a tight connection. Next, a #2-0 Vicryl suture was then used to close the peritenon over the Achilles tendon. The wound was once again copiously irrigated and dried. A #2-0 Vicryl sutures were then used to close the skin and subcutaneous fashion followed by #4-0 suture in the subcuticular closure on the skin. Steri-Strips were then placed over the wound and the sterile dressing was applied consisting of 4x4s, Kerlix roll, sterile Kerlix and a short length fiberglass cast in a plantar position. At this time, the Department of anesthesia reversed the anesthetic. The patient was transferred back to hospital gurney to the Postanesthesia Care Unit. The patient tolerated the procedure well. There were no complications. | surgery, repair, achilles tendon rupture, longitudinal incision, tendon rupture, achilles tendon, tendon, achilles, rupture, extremity |
1,276 | Removal of the hardware and revision of right AC separation. Loose hardware with superior translation of the clavicle implants. Arthrex bioabsorbable tenodesis screws. | Surgery | AC Separation Revision & Hardware Removal | PREOPERATIVE DIAGNOSIS:, Right AC separation.,POSTOPERATIVE DIAGNOSIS:, Right AC separation.,PROCEDURES:, Removal of the hardware and revision of right AC separation.,ANESTHESIA:, General.,BLOOD LOSS:, 100 cc.,COMPLICATIONS:, None.,FINDINGS: , Loose hardware with superior translation of the clavicle implants.,IMPLANTS: , Arthrex bioabsorbable tenodesis screws.,SUMMARY: , After informed consent was obtained and verified, the patient was brought to the operating room and placed supine on the operating table. After uneventful general anesthesia was obtained, he was positioned in the beach chair and his right shoulder was sterilely prepped and draped in a normal fashion. The incision was reopened and the hardware was removed without difficulty. The AC joint was inspected and reduced. An allograft was used to recreate the coracoacromial ligaments and then secured to decorticate with a bioabsorbable tenodesis screw and then to the clavicle. And two separate areas that were split, one taken medially and one taken laterally, and then sewed together for further stability. This provided good stability with no further superior translation of the clavicle as viewed under fluoroscopy. The wound was copiously irrigated and the wound was closed in layers and a soft dressing was applied. He was awakened from anesthesia and taken to recovery room in a stable condition.,Final needle and instrument counts were correct. | surgery, loose hardware, superior translation, clavicle implants, ac separation, removal of the hardware, arthrex bioabsorbable tenodesis screws, bioabsorbable tenodesis, tenodesis screws, translation, implants, bioabsorbable, tenodesis, clavicle, separation, hardware |
1,277 | Excision of abscess, removal of foreign body. Repair of incisional hernia. Recurrent re-infected sebaceous cyst of abdomen. Abscess secondary to retained foreign body and incisional hernia. | Surgery | Abscess Excision | PREOPERATIVE DIAGNOSIS: , Recurrent re-infected sebaceous cyst of abdomen.,POSTOPERATIVE DIAGNOSES:,1. Abscess secondary to retained foreign body.,2. Incisional hernia.,PROCEDURES,1. Excision of abscess, removal of foreign body.,2. Repair of incisional hernia.,ANESTHESIA: , LMA.,INDICATIONS: , Patient is a pleasant 37-year-old gentleman who has had multiple procedures including a laparotomy related to trauma. The patient has had a recurrently infected cyst of his mass at the superior aspect of his incision, which he says gets larger and then it drains internally, causing him to be quite ill. He presented to my office and I recommended that he undergo exploration of this area and removal. The procedure, purpose, risks, expected benefits, potential complications, and alternative forms of therapy were discussed with him and he was agreeable to surgery.,FINDINGS:, The patient was found upon excision of the cyst that it contained a large Prolene suture, which is multiply knotted as it always is; beneath this was a very small incisional hernia, the hernia cavity, which contained omentum; the hernia was easily repaired.,DESCRIPTION OF PROCEDURE: , The patient was identified, then taken into the operating room, where after induction of an LMA anesthetic, his abdomen was prepped with Betadine solution and draped in sterile fashion. The puncta of the wound lesion was infiltrated with methylene blue and peroxide. The lesion was excised and the existing scar was excised using an ellipse and using a tenotomy scissors, the cyst was excised down to its base. In doing so, we identified a large Prolene suture within the wound and followed this cyst down to its base at which time we found that it contained omentum and was in fact overlying a small incisional hernia. The cyst was removed in its entirety, divided from the omentum using a Metzenbaum and tying with 2-0 silk ties. The hernia repair was undertaken with interrupted 0 Vicryl suture with simple sutures. The wound was then irrigated and closed with 3-0 Vicryl subcutaneous and 4-0 Vicryl subcuticular and Steri-Strips. Patient tolerated the procedure well. Dressings were applied and he was taken to recovery room in stable condition. | surgery, sebaceous cyst, prolene suture, incisional hernia, incisional, abscess, hernia, abdomen, omentum, excision, cyst, |
1,278 | Congenital chylous ascites and chylothorax and rule out infradiaphragmatic lymphatic leak. Diffuse intestinal and mesenteric lymphangiectasia. | Surgery | Abdominal Exploration | PREOPERATIVE DIAGNOSES: ,1. Congenital chylous ascites and chylothorax.,2. Rule out infradiaphragmatic lymphatic leak.,POSTOPERATIVE DIAGNOSES: , Diffuse intestinal and mesenteric lymphangiectasia.,ANESTHESIA: , General.,INDICATION: ,The patient is an unfortunate 6-month-old baby boy, who has been hospitalized most of his life with recurrent chylothoraces and chylous ascites. The patient has been treated somewhat successfully with TPN and voluntary restriction of enteral nutrition, but he had repeated chylothoraces. Last week, Dr. X took the patient to the operating room in hopes that with thoracotomy, a thoracic duct leak could be found, which would be successfully closed surgically. However at the time of his thoracotomy exploration what was discovered was a large amount of transdiaphragmatic transition of chylous ascites coming from the abdomen. Dr. X opened the diaphragm and could literally see a fountain of chylous fluid exiting through the diaphragmatic hole. This was closed, and we decided that perhaps an abdominal exploration as a last stage effort would allow us to find an area of lymphatic leak that could potentially help the patient from this dismal prognostic disease. We met with his parents and talked to them about this, and he is here today for that attempt.,OPERATIVE FINDINGS: ,The patient's abdomen was relatively soft, minimally distended. Exploration through supraumbilical transverse incision immediately revealed a large amount of chylous ascites upon entering into the peritoneal cavity. What we found which explains the chronic chylous ascites and chylothorax was a diffuse lymphangiectatic picture involving the small bowel mesentery approximately two thirds to three quarters of the distal small bowel including all of the ileum, the cecum, and the portion of the ascending colon. It appeared that any attempt to resect this area would have been met with failure because of the extensive lymphatic dilatation all the way down towards the root of the supramesenteric artery. There was about one quarter to one third of the jejunum that did not appear to be grossly involved, but I did not think that resection of three quarters of the patient's small bowel would be viable surgical option. Instead, we opted to close his abdomen and refer for potential small intestine transplantation procedure in the future if he is a candidate for that.,The lymphatic abnormality was extensive. They were linear dilated lymphatic channels on the serosal surface of the bowel in the mesentery. They were small aneurysm-like pockets of chyle all along the course of the mesenteric structures and in the mesentery medially adjacent to the bowel as well. No other major retroperitoneal structure or correctable structure was identified. Both indirect inguinal hernias were wide open and could be palpated from an internal aspect as well.,DESCRIPTION OF OPERATION: ,The patient was brought from the Pediatric Intensive Care Unit to the operating room within an endotracheal tube im place and with enteral feeds established at full flow to provide maximum fat content and maximum lymphatic flow. We conducted a surgical time-out and reiterated all of the patient's important identifying information and confirmed the operative plan as described above. Preparation and draping of his abdomen was done with chlorhexidine based prep solution and then we opened his peritoneal cavity through a transverse supraumbilical incision dividing both rectus muscles and all layers of the abdominal wall fascia. As the peritoneal cavity was entered, we divided the umbilical vein ligamentum teres remnant between Vicryl ties, and we were able to readily identify a large amount of chylous ascites that had been previously described. The bowel was eviscerated, and then with careful inspection, we were able to identify this extensive area of intestinal and mesenteric lymphangiectasia that was a source of the patient's chylous ascites. The small bowel from the ligament of Treitz to the proximal to mid jejunum was largely unaffected, but did not appear that resection of 75% of the small intestine and colon would be a satisfactory tradeoff for The patient, but would likely render him with significant short bowel and nutritional and metabolic problems. Furthermore, it might burn bridges necessary for consideration of intestinal transplantation in the future if that becomes an option. We suctioned free all of the chylous accumulations, replaced the intestines to their peritoneal cavity, and then closed the patient's abdominal incision with 4-0 PDS on the posterior sheath and 3-0 PDS on the anterior rectus sheath. Subcuticular 5-0 Monocryl and Steri-Strips were used for skin closure.,The patient tolerated the procedure well. He lost minimal blood, but did lose approximately 100 mL of chylous fluid from the abdomen that was suctioned free as part of the chylous ascitic leak. The patient was returned to the Pediatric Intensive Care Unit with his endotracheal tube in place and to consider the next stage of management, which might be an attempted additional type of feeding or referral to an Intestinal Transplantation Center to see if that is an option for the patient because he has no universally satisfactory medical or surgical treatment for this at this time. | surgery, intestinal, mesenteric, lymphangiectasia, ascites, chylothorax, lymphatic leak, infradiaphragmatic, abdominal exploration, congenital chylous, mesenteric lymphangiectasia, peritoneal cavity, chylous, abdominal, congenital, abdomen, lymphatic |
1,279 | Incision and drainage (I&D) of abdominal abscess, excisional debridement of nonviable and viable skin, subcutaneous tissue and muscle, then removal of foreign body. | Surgery | Abdominal Abscess I&D | PREOPERATIVE DIAGNOSIS: , Abdominal wall abscess.,POSTOPERATIVE DIAGNOSIS: , Abdominal wall abscess.,PROCEDURE: , Incision and drainage (I&D) of abdominal abscess, excisional debridement of nonviable and viable skin, subcutaneous tissue and muscle, then removal of foreign body.,ANESTHESIA: , LMA.,INDICATIONS: , Patient is a pleasant 60-year-old gentleman, who initially had a sigmoid colectomy for diverticular abscess, subsequently had a dehiscence with evisceration. Came in approximately 36 hours ago with pain across his lower abdomen. CT scan demonstrated presence of an abscess beneath the incision. I recommended to the patient he undergo the above-named procedure. Procedure, purpose, risks, expected benefits, potential complications, alternatives forms of therapy were discussed with him, and he was agreeable to surgery.,FINDINGS:, The patient was found to have an abscess that went down to the level of the fascia. The anterior layer of the fascia was fibrinous and some portions necrotic. This was excisionally debrided using the Bovie cautery, and there were multiple pieces of suture within the wound and these were removed as well.,TECHNIQUE: ,Patient was identified, then taken into the operating room, where after induction of appropriate anesthesia, his abdomen was prepped with Betadine solution and draped in a sterile fashion. The wound opening where it was draining was explored using a curette. The extent of the wound marked with a marking pen and using the Bovie cautery, the abscess was opened and drained. I then noted that there was a significant amount of undermining. These margins were marked with a marking pen, excised with Bovie cautery; the curette was used to remove the necrotic fascia. The wound was irrigated; cultures sent prior to irrigation and after achievement of excellent hemostasis, the wound was packed with antibiotic-soaked gauze. A dressing was applied. The finished wound size was 9.0 x 5.3 x 5.2 cm in size. Patient tolerated the procedure well. Dressing was applied, and he was taken to recovery room in stable condition. | surgery, excisional debridement, subcutaneous tissue, abdominal wall abscess, foreign body, abdominal abscess, bovie cautery, abdominal, i&d, wound, incision, abscess, |
1,280 | Speech therapy discharge summary. The patient was admitted for skilled speech therapy secondary to cognitive-linguistic deficits. | Speech - Language | Speech Therapy - Discharge Summary | LONG-TERM GOALS:, Both functional and cognitive-linguistic ability to improve safety and independence at home and in the community. This goal has been met based on the patient and husband reports the patient is able to complete all activities, which she desires to do at home. During the last reevaluation, the patient had a significant progress and all cognitive domains evaluated, which are attention, memory, executive functions, language, and visuospatial skill. She continues to have an overall mild cognitive-linguistic deficit, but this is significantly improved from her initial evaluation, which showed severe impairment., ,The patient does no longer need a skilled speech therapy because she has accomplished all of her goals and her progress has plateaued. The patient and her husband both agreed with the patient's discharge. | speech - language, narrative, memory, executive function, attention, speech therapy, visuospatial, accuracy, linguistic, cognitive, speechNOTE,: Thesetranscribed medical transcription sample reports and examples are provided by various users andare for reference purpose only. MTHelpLine does not certify accuracy and quality of sample reports.These transcribed medical transcription sample reports may include some uncommon or unusual formats;this would be due to the preference of the dictating physician. All names and dates have beenchanged (or removed) to keep confidentiality. Any resemblance of any type of name or date orplace or anything else to real world is purely incidental., |
1,281 | Global aphasia. The patient is referred to Medical Center's Outpatient Rehabilitation Department for skilled speech therapy, status post stroke. | Speech - Language | Speech Therapy Evaluation | MEDICAL DIAGNOSIS:, Strokes.,SPEECH AND LANGUAGE THERAPY DIAGNOSIS: ,Global aphasia.,SUBJECTIVE: ,The patient is a 44-year-old female who is referred to Medical Center's Outpatient Rehabilitation Department for skilled speech therapy, status post stroke. The patient's sister-in-law was present throughout this assessment and provided all the patient's previous medical history. Based on the sister-in-law's report, the patient had a stroke on 09/19/08. The patient spent 6 weeks at XY Medical Center, where she was subsequently transferred to XYZ for therapy for approximately 3 weeks. ABCD brought the patient to home the Monday before Thanksgiving, because they were not satisfied with the care the patient was receiving at a skilled nursing facility in Tucson. The patient's previous medical history includes a long history of illegal drug use to include cocaine, crystal methamphetamine, and marijuana. In March of 2008, the patient had some type of potassium issue and she was hospitalized at that time. Prior to the stroke, the patient was not working and ABCD reported that she believes the patient completed the ninth grade, but she did not graduate from high school. During the case history, I did pose several questions to the patient, but her response was often "no." She was very emotional during this evaluation and crying occurred multiple times.,OBJECTIVE: ,To evaluate the patient's overall communication ability, a Western Aphasia Battery was completed. Also tests were not done due to time constraint and the patient's severe difficulty and emotional state. Speech automatic tests were also completed to determine if the patient had any functional speech.,ASSESSMENT:, Based on the results of the Weston aphasia battery, the patient's deficits most closely resemble global aphasia. On the spontaneous speech subtest, the patient responded "no" to all questions asked except for how are you today where she gave a thumbs-up. She provided no responses to picture description task and it is unclear if the patient was unable to follow the direction or if she was unable to see the picture clearly. The patient's sister-in-law did state that the patient wore glasses, but she currently does not have them and she did not know the extent the patient's visual deficit.,On the auditory verbal comprehension portion of the Western Aphasia Battery, the patient answered "no" to all "yes/no" questions. The auditory word recognition subtest, the patient had 5 out of 60 responses correct. With the sequential command, she had 10 out of 80 corrects. She was able to shut her eyes, point to the window, and point to the pen after directions. With repetition subtest, she repeated bed correctly, but no other stimuli. At this time, the patient became very emotional and repeatedly stated "I can't". During the naming subtest of the Western Aphasia Battery, the patient's responses contained numerous paraphasias and her speech was often unintelligible due to jargon. The word fluency test was not administered and the patient scored 2 out of 10 on the sentence completion task and 0 out of 10 on the responsive speech. In regards to speech automatics, the patient is able to count from 1 to 9 accurately; however, stated 7 instead of 10 at the end of the task. She is not able to state the days of the week or months in the year or her name at this time. She cannot identify the day on calendar and was unable to verbally state the date or month.,DIAGNOSTIC IMPRESSION: ,The patient's communication deficits most closely resemble global aphasia where she has difficulty with both receptive as well as expressive communication. She does perseverate and is very emotional due to probable frustration. Outpatient skilled speech therapy is recommended to improve the patient's functional communication skills.,PATIENT GOAL: , Her sister-in-law stated that they would like to improve upon the patient's speech to allow her to communicate more easily at home.,PLAN OF CARE: , Outpatient skilled speech therapy two times a week for the next 12 weeks. Therapy to include aphasia treatment and home activities.,SHORT-TERM GOALS (8 WEEKS):,1. The patient will answer simple "yes/no" questions with greater than 90% accuracy with minimal cueing.,2. The patient will be able to complete speech automatic tasks with greater than 80% accuracy without models or cueing.,3. The patient will be able to complete simple sentence completion and/or phrase completion with greater than 80% accuracy with minimal cueing.,4. The patient will be able to follow simple one-step commands with greater than 80% accuracy with minimal cueing.,5. The patient will be able to name 10 basic everyday objects with greater than 80% accuracy with minimal cueing.,SHORT-TERM GOALS (12 WEEKS):, Functional communication abilities to allow the patient to express her basic wants and needs. | speech - language, speech automatic tasks, minimal cueing, sentence completion, western aphasia battery, skilled speech therapy, global aphasia, speech therapy, speech, aphasia, |
1,282 | The patient was referred for outpatient skilled speech therapy, secondary to right hemisphere disorder, status post stroke. The patient attended nine outpatient skilled speech therapy sessions. | Speech - Language | Speech Therapy - Discharge Summary - 2 | The patient made some progress during therapy. She accomplished two and a half out of her five short-term therapy goals. We did complete an oral mechanism examination and clinical swallow evaluation, which showed her swallowing to be within functional limits. The patient improved on her turn taking skills during conversation, and she was able to listen to a narrative and recall the main idea plus five details after a three-minute delay independently. The patient continues to have difficulty with visual scanning in cancellation task, secondary to her significant left neglect. She also did not accomplish her sustained attention goal, which required her to complete tasks greater than 80% accuracy for at least 15 minutes independently. Thus she also continued to have difficulty with reading, comprehension, secondary to the significance of her left neglect. The patient was initially authorized for 12 outpatient speech therapy sessions, but once again she only attended 9. Her last session occurred on 01/09/09. She has not made any additional followup sessions with me for over three weeks, so she is discharged from my services at this time. | speech - language, outpatient speech therapy, swallow evaluation, swallowing, skilled speech therapy, hemisphere disorder, speech therapy, speechNOTE,: Thesetranscribed medical transcription sample reports and examples are provided by various users andare for reference purpose only. MTHelpLine does not certify accuracy and quality of sample reports.These transcribed medical transcription sample reports may include some uncommon or unusual formats;this would be due to the preference of the dictating physician. All names and dates have beenchanged (or removed) to keep confidentiality. Any resemblance of any type of name or date orplace or anything else to real world is purely incidental. |
1,283 | The patient was referred to Medical Center's Outpatient Rehabilitation Department for skilled speech therapy to improve her functional communication skills and swallowing function and safety. | Speech - Language | Speech Therapy - Discharge Summary - 1 | HISTORY: , The patient is a 67-year-old female, was referred to Medical Center's Outpatient Rehabilitation Department for skilled speech therapy to improve her functional communication skills and swallowing function and safety. At the onset of therapy, on 03/26/08, the patient was NPO with a G-tube and the initial speech and language evaluation revealed global aphasia with an aphasia quotient of 3.6/100 based on the Western Aphasia Battery. Since the initial evaluation, the patient has attended 60 outpatient speech therapy sessions, which have focussed on her receptive communication, expressive language, multimodality communication skills, and swallowing function and safety.,SHORT-TERM GOALS:,1. The patient met 3 out of 4 original short-term therapy goals, which were to complete a modified barium swallow study, which she did do and which revealed no aspiration. At this time, the patient is eating and drinking and taking all medications by mouth; however, her G-tube is still present. The patient was instructed to talk to the primary care physician about removal of her feeding tube.,2. The patient will increase accuracy of yes-no responses to greater than 80% accuracy. She did accomplish this goal. The patient is also able to identify named objects with greater than 80% accuracy.,ADDITIONAL GOALS: , Following the completion of these goals, additional goals were established. Based on reevaluation, the patient met 2 out of these 3 initial goals and she is currently able to read and understand simple sentences with greater than 90% accuracy independently and she is able to write 10 words related to basic wants and needs with greater than 80% accuracy independently. The patient continues to have difficulty stating verbally, yes or no, to questions as well as accurately using head gestures and to respond to yes-no questions. The patient continues to have marked difficulty with her expressive language abilities. She is able to write simple words to help express her basic wants and needs. She has made great strides; however, with her receptive communication, she is able to read words as well as short phrases and able to point to named objects and answer simple-to-moderate complex yes-no questions. A reevaluation completed on 12/01/08, revealed an aphasia quotient of 26.4. Once again, she made significant improvement and comprehension, but continues to have unintelligible speech. An alternative communication device was discussed with the patient and her husband, but at this time, the patient does not want to utilize a communication device. If, in the future, the patient continues to struggle with her expressive communication, an alternative augmented communication device would be a benefit to her. Please reconsult at that time if and when the patient is ready to use a speech generating device. The patient is discharged from my services at this time due to a plateau in her progress. Numerous home activities were recommended to allow her to continue to make progress at home. | speech - language, communication skills, g-tube, aphasia, language evaluation, western aphasia battery, skilled speech therapy, swallowing function, speech therapy, therapy, swallowing, aspiration, speech, communication, |
1,284 | Abdominosacrocolpopexy, enterocele repair, cystoscopy, and lysis of adhesions. | Surgery | Abdominosacrocolpopexy | PREOPERATIVE DIAGNOSES:,1. Vault prolapse.,2. Enterocele.,PREOPERATIVE DIAGNOSES:,1. Vault prolapse.,2. Enterocele.,OPERATIONS:,1. Abdominosacrocolpopexy.,2. Enterocele repair.,3. Cystoscopy.,4. Lysis of adhesions.,ANESTHESIA: , General endotracheal.,ESTIMATED BLOOD LOSS:, Less than 100 mL.,SPECIMEN: , None.,BRIEF HISTORY:, The patient is a 53-year-old female with history of hysterectomy presented with vaginal vault prolapse. The patient had good support in the anterior vagina and in the posterior vagina but had significant apical prolapse. Options such as watchful waiting, pessary, abdominal surgery, robotic sacrocolpopexy versus open sacrocolpopexy were discussed.,The patient already had multiple abdominal scars. Risk of open surgery was little bit higher for the patient. After discussing the options the patient wanted to proceed a Pfannenstiel incision and repair of the sacrocolpopexy. Risks of anesthesia, bleeding, infection, pain, MI, DVT, PE, mesh erogenic exposure, complications with mesh were discussed. The patient understood the risks of recurrence, etc, and wanted to proceed with the procedure. The patient was told to perform no heavy lifting for 3 months, etc. The patient was bowel prepped, preoperative antibiotics were given.,DETAILS OF THE OPERATION: , The patient was brought to the OR, anesthesia was applied. The patient was placed in dorsal lithotomy position. The patient was prepped and draped in usual sterile fashion. A Pfannenstiel low abdominal incision was done at the old incision site. The incision was carried through the subcutaneous tissue through the fascia and the fascia was lifted off the rectus abdominus muscle. The muscle was split in the middle and peritoneum was entered using sharp mets. There was no injury to the bowel upon entry. There were significant adhesions which were unleashed. All the adhesions in the sigmoid colon from the right lower quadrant and left lower quadrant were released, similarly colon was mobilized. There was minimal space, everything was packed, Bookwalter placed then over the sacral bone. The middle of the sacral bone was identified. The right ureter was clearly identified and was lateral to where the posterior peritoneum was opened. The ligament over the sacral or sacral __________ was easily identified, 0 Ethibond stitches were placed x3. A 1 cm x 5 cm mesh was cut out. This was a Prolene soft mesh which was tied at the sacral ligament. The bladder was clearly off the vault area which was exposed, in the raw surface 0 Ethibond stitches were placed x3. The mesh was attached. The apex was clearly up enterocele sac was closed using 4-0 Vicryl without much difficulty. The ureter was not involved at all in this process. The peritoneum was closed over the mesh. Please note that the peritoneum was opened and it was brought around and over the mesh so that the mesh would not be exposed to the bowel. Prior to closure antibiotic irrigation was done using Ancef solution. The mesh has been exposed in antibiotic solution prior to the usage.,After a through irrigation with L and half of antibiotic solution. All the solution was removed. Good hemostasis was obtained. All the packing was removed. Count was correct. Rectus abdominus muscle was brought together using 4-0 Vicryl. The fascia was closed using loop #1 PDS in running fascia from both sides and was tied in the middle. Subcutaneous tissue was closed using 4-0 Vicryl and the skin was closed using 4-0 Monocryl in subcuticular fashion. Cystoscopy was done at the end of the procedure. Please note that the Foley was in place throughout the entire procedure which was placed thoroughly at the beginning of the procedure. Cystoscopy was done and indigo carmine has been given. There was good efflux of indigo carmine in both of the ureteral opening. There was no injury to the rectum or the bladder. The bladder appeared completely normal. The rectal exam was done at the end of the procedure after the cystoscopy. After the cysto was done, the scope was withdrawn, Foley was placed back. The patient was brought to recovery in the stable condition. | surgery, enterocele repair, cystoscopy, lysis of adhesions, enterocele, ethibond stitches, indigo carmine, vault prolapse, sacrocolpopexy, peritoneum, abdominosacrocolpopexy, |
1,285 | Status post brain tumor with removal. The patient did receive skilled speech therapy while in the acute rehab, which focused on higher level cognitive and linguistic skills such as attention, memory, mental flexibility, and improvement of her executive function. | Speech - Language | Speech Therapy Evaluation - 1 | DIAGNOSIS: , Status post brain tumor with removal.,SUBJECTIVE: ,The patient is a 64-year-old female with previous medical history of breast cancer that has metastasized to her lung, liver, spleen, and brain, status post radiation therapy. The patient stated that on 10/24/08 she had a brain tumor removed with subsequent left-sided weakness. The patient was readmitted to ABC Hospital on 12/05/08 and was found to have massive swelling in the brain and a second surgery was performed to reduce the swelling. The patient remained at the acute rehab at ABC until she was discharged home on 01/05/09. The patient did receive skilled speech therapy while in the acute rehab, which focused on higher level cognitive and linguistic skills such as attention, memory, mental flexibility, and improvement of her executive function. The patient also complains of difficulty with word retrieval and slurring of speech. The patient denies any difficulty with swallowing at this time.,OBJECTIVE: ,Portions of the cognitive linguistic quick test was administered. An oral mechanism exam was performed. A motor speech protocol was completed.,The cognitive linguistic subtests of recalling personal facts, symbol cancellation, confrontational naming, clock drawing, story retelling, generative naming, design and memory, and completion of mazes was administered.,The patient was 100% accurate with recalling personal facts, completion of the symbol cancellation tasks, and with confrontational naming. She had no difficulty with the clock drawing task; however, she has considerable hand tremors, which makes writing difficult. In the storytelling task, she scored within normal limits. She was also within normal limits for generative naming. She did have difficulty with the design, memory, and mazes subtests. She was unable to complete the second maze during the allotted time. The design generation subtest was also completed. She was able to draw four unique designs, and toward the end of the tasks was no longer able to recall the stated direction.,ORAL MECHANISM EXAMINATION:, The patient has mild left facial droop with decreased nasolabial fold. Tongue is at midline, and lingual range of motion and strength are within functional limit. The patient does complain of biting her tongue on occasion, but denied biting the inside of her cheeks. Her AMRs are judged to be within functional limit. Her rate of speech is decreased with a monotonous vocal quality. The decreased rate may be a compensation for decreased word retrieval ability. The patient's speech is judged to be 100% intelligible without background noise.,DIAGNOSTIC IMPRESSION: ,The patient has mild cognitive linguistic deficits in the areas of higher level cognitive function seen in mental flexibility, memory, and executive function.,PLAN OF CARE:, Outpatient skilled speech therapy two times a week for four weeks to include cognitive linguistic treatment.,SHORT-TERM GOALS (THREE WEEKS):,1. The patient will complete deductive reasoning and mental flexibility tasks with greater than 90% accuracy, independently.,2. The patient will complete perspective memory test with 100% accuracy using compensatory strategy.,3. The patient will complete visual perceptual activities, which focus on scanning, flexibility, and problem solving with greater than 90% accuracy with minimal cueing.,4. The patient will listen to and/or read a lengthy narrative and be able to recall at least 6 details after a 15-minute delay, independently.,PATIENT'S GOAL: ,To improve functional independence and cognitive abilities.,LONG-TERM GOAL (FOUR WEEKS): ,Functional cognitive linguistic abilities to improve safety and independence at home and to decrease burden of care on caregiver., | speech - language, linguistic skills, memory, mental flexibility, deductive reasoning, skilled speech therapy, speech therapy, cognitive linguistic, therapy, linguistic, speech, cognitive, |
1,286 | Cognitive linguistic impairment secondary to stroke. The patient was referred to Medical Center's Outpatient Rehabilitation Department for skilled speech therapy secondary to cognitive linguistic deficits. | Speech - Language | Cognitive Linguistic Impairment - Discharge | DIAGNOSIS: , Cognitive linguistic impairment secondary to stroke.,NUMBER OF SESSIONS COMPLETED:, 5,HOSPITAL COURSE: ,The patient is a 73-year-old female who was referred to Medical Center's Outpatient Rehabilitation Department for skilled speech therapy secondary to cognitive linguistic deficits. Based on the initial evaluation completed 12/29/08, the patient had mild difficulty with generative naming and auditory comprehension and recall. The patient's skilled speech therapy was recommended for three times a week for 8 weeks to improve her overall cognitive linguistic abilities. At this time, the patient has accomplished all 5 of her short-term therapy goals. She is able to complete functional mass tasks with 100% accuracy independently. She is able to listen to a narrative and recall the main idea plus at least five details after a 10 minute delay independently.,She is able to read a newspaper article and recall the main idea plus five details after a 15 minute delay independently. She is able to state 15 items in a broad category within a minute and a half independently. The patient is also able to complete deductive reasoning tasks to promote her mental flexibility with 100% accuracy independently. The patient also met her long-term therapy goal of functional cognitive linguistic abilities to return to teaching and improve her independence and safety at home. The patient is no longer in need of skilled speech therapy and is discharged from my services. She did quite well in therapy and also agreed with this discharge. | speech - language, stroke, linguistic deficits, speech therapy, skilled speech therapy, linguistic impairment, cognitive linguistic, cognitive, linguistic, |
1,287 | The patient is a 67-year-old white female with a history of uterine papillary serous carcinoma who is status post 6 cycles of carboplatin and Taxol, is here today for followup. | SOAP / Chart / Progress Notes | Uterine Papillary Serous Carcinoma | HISTORY OF PRESENT ILLNESS:, The patient is a 67-year-old white female with a history of uterine papillary serous carcinoma who is status post 6 cycles of carboplatin and Taxol, is here today for followup. Her last cycle of chemotherapy was finished on 01/18/08, and she complains about some numbness in her right upper extremity. This has not gotten worse recently and there is no numbness in her toes. She denies any tingling or burning.,REVIEW OF SYSTEMS: , Negative for any fever, chills, nausea, vomiting, headache, chest pain, shortness of breath, abdominal pain, constipation, diarrhea, melena, hematochezia or dysuria. The patient is concerned about her blood pressure being up a little bit and also a mole that she had noticed for the past few months in her head.,PHYSICAL EXAMINATION:,VITAL SIGNS: Temperature 35.6, blood pressure 143/83, pulse 65, respirations 18, and weight 66.5 kg. GENERAL: She is a middle-aged white female, not in any distress. HEENT: No lymphadenopathy or mucositis. CARDIOVASCULAR: Regular rate and rhythm. LUNGS: Clear to auscultation bilaterally. EXTREMITIES: No cyanosis, clubbing or edema. NEUROLOGICAL: No focal deficits noted. PELVIC: Normal-appearing external genitalia. Vaginal vault with no masses or bleeding.,LABORATORY DATA: , None today.,RADIOLOGIC DATA: , CT of the chest, abdomen, and pelvis from 01/28/08 revealed status post total abdominal hysterectomy/bilateral salpingo-oophorectomy with an unremarkable vaginal cuff. No local or distant metastasis. Right probably chronic gonadal vein thrombosis.,ASSESSMENT: , This is a 67-year-old white female with history of uterine papillary serous carcinoma, status post total abdominal hysterectomy and bilateral salpingo-oophorectomy and 6 cycles of carboplatin and Taxol chemotherapy. She is doing well with no evidence of disease clinically or radiologically.,PLAN:,1. Plan to follow her every 3 months and CT scans every 6 months for the first 2 years.,2. The patient was advised to contact the primary physician for repeat blood pressure check and get started on antihypertensives if it is persistently elevated.,3. The patient was told that the mole that she is mentioning in her head is no longer palpable and just to observe it for now.,4. The patient was advised about doing Kegel exercises for urinary incontinence, and we will address this issue again during next clinic visit if it is persistent., | soap / chart / progress notes, chemotherapy, uterine papillary serous carcinoma, oophorectomy, carboplatin, taxol, abdominal, uterine, papillary, carcinoma, |
1,288 | The patient was referred for an outpatient speech and language pathology consult to increase speech and swallowing abilities. The patient is currently NPO with G-tube to meet all of his hydration and nutritional needs. A trial of Passy-Muir valve was completed to allow the patient to achieve hands-free voicing. | Speech - Language | Barium Swallow Study & Speech Evaluation | CURRENT MEDICATIONS:, Lortab.,PREVIOUS MEDICAL HISTORY: , Cardiac stent in 2000.,PATIENT'S GOAL: , To eat again by mouth.,STUDY: ,A trial of Passy-Muir valve was completed to allow the patient to achieve hands-free voicing and also to improve his secretion management. A clinical swallow evaluation was not completed due to the severity of the patient's mucus and lack of saliva control.,The patient's laryngeal area was palpated during a dry swallow and he does have significantly reduced laryngeal elevation and radiation fibrosis. The further evaluate of his swallowing function is safety; a modified barium swallow study needs to be concluded to objectively evaluate his swallow safety, and to rule out aspiration. A trial of neuromuscular electrical stimulation therapy was completed to determine if this therapy protocol will be beneficial and improving the patient's swallowing function and safety.,For his neuromuscular electrical stimulation therapy, the type was BMR with a single mode cycle time is 4 seconds and 12 seconds off with frequency was 60 __________ with a ramp of 2 seconds, phase duration was 220 with an output of 99 milliamps. Electrodes were placed on the suprahyoid/submandibular triangle with an upright body position, trial length was 10 minutes. On a pain scale, the patient reported no pain with the electrical stimulation therapy.,FINDINGS: ,The patient was able to tolerate a 5-minute placement of the Passy-Muir valve. He reported no discomfort on the inhalation; however, he felt some resistance on exhalation. Instructions were given on care placement and cleaning of the Passy-Muir valve. The patient was instructed to buildup tolerance over the next several days of his Passy-Muir valve and to remove the valve at anytime or he is going to be sleeping or napping throughout the day. The patient's voicing did improve with the Passy-Muir valve due to decreased leakage from his trach secondary to finger occlusion. Mucus production also seemed to decrease when the Passy-Muir was placed.,On the dry swallow during this evaluation, the patient's laryngeal area is reduced and tissues around his larynx and showed radiation fibrosis. The patient's neck range of motion appears to be adequate and within normal limits.,A trial of neuromuscular electrical stimulation therapy:,The patient tolerating the neuromuscular electrical stimulation, we did achieve poor passive response, but these muscles were contracting and the larynx was moving upon stimulation. The patient was able to actively swallow with stimulation approximately 30% of presentation.,DIAGNOSTIC IMPRESSION: , The patient with a history of head and neck cancer status post radiation and chemotherapy with radiation fibrosis, which is impeding his swallowing abilities. The patient would benefit from outpatient skilled speech therapy for neuromuscular electrical stimulation for muscle reeducation to improve his swallowing function and safety and he would benefit from a placement of a Passy-Muir valve to have hands-free communication.,PLAN OF CARE: , Outpatient skilled speech therapy two times a week to include neuromuscular electrical stimulation therapy, Passy-Muir placement and a completion of the modified barium swallow study.,SHORT-TERM GOALS (6 WEEKS):,1. Completion of modified barium swallow study.,2. The patient will coordinate volitional swallow with greater than 75% of the neuromuscular electrical stimulations.,3. The patient will increase laryngeal elevation by 50% for airway protection.,4. The patient will tolerate placement of Passy-Muir valve for greater than 2 hours during awaking hours.,5. The patient will tolerate therapeutic feedings with the speech and language pathologist without signs and symptoms of aspiration.,6. The patient will decrease mild facial restrictions to the anterior neck by 50% to increase laryngeal movement.,LONG-TERM GOALS (8 WEEKS):,1. The patient will improve secretion management to tolerable levels.,2. The patient will increase amount and oral consistency of p.o. intake tolerated without signs and symptoms of aspirations.,3. The patient will be able to communicate without using finger occlusion with the assistance of a Passy-Muir valve. | null |
1,289 | This is a pleasant 50-year-old female who has undergone an APR secondary to refractory ulcerative colitis. Overall, her quality of life has significantly improved since she had her APR. She is functioning well with her ileostomy. | SOAP / Chart / Progress Notes | Wound Check - Status Post APR | HISTORY OF PRESENT ILLNESS:, Ms. Connor is a 50-year-old female who returns to clinic for a wound check. The patient underwent an APR secondary to refractory ulcerative colitis. Subsequently, she developed a wound infection, which has since healed. On our most recent visit to our clinic, she has her perineal stitches removed and presents today for followup of her perineal wound. She describes no drainage or erythema from her bottom. She is having good ostomy output. She does not describe any fevers, chills, nausea, or vomiting. The patient does describe some intermittent pain beneath the upper portion of the incision as well as in the right lower quadrant below her ostomy. She has been taking Percocet for this pain and it does work. She has since run out has been trying extra strength Tylenol, which will occasionally help this intermittent pain. She is requesting additional pain medications for this occasional abdominal pain, which she still experiences.,PHYSICAL EXAMINATION: , Temperature 95.8, pulse 68, blood pressure 132/73, and weight 159 pounds. This is a pleasant female in no acute distress. The patient's abdomen is soft, nontender, nondistended with a well-healed midline scar. There is an ileostomy in the right hemiabdomen, which is pink, patent, productive, and protuberant. There are no signs of masses or hernias over the patient's abdomen.,ASSESSMENT AND PLAN: , This is a pleasant 50-year-old female who has undergone an APR secondary to refractory ulcerative colitis. Overall, her quality of life has significantly improved since she had her APR. She is functioning well with her ileostomy. She did have concerns or questions about her diet and we discussed the BRAT diet, which consisted of foods that would slow down the digestive tract such as bananas, rice, toast, cheese, and peanut butter. I discussed the need to monitor her ileostomy output and preferential amount of daily output is 2 liters or less. I have counseled her on refraining from soft drinks and fruit drinks. I have also discussed with her that this diet is moreover a trial and error and that she may try certain foods that did not agree with her ileostomy, however others may and that this is something she will just have to perform trials with over the next several months until she finds what foods that she can and cannot eat with her ileostomy. She also had questions about her occasional abdominal pain. I told her that this was probably continue to improve as months went by and I gave her a refill of her Percocet for the continued occasional pain. I told her that this would the last time I would refill the Percocet and if she has continued pain after she finishes this bottle then she would need to start ibuprofen or Tylenol if she had continued pain. The patient then brought up some right hand and arm numbness, which has been there postsurgically and was thought to be from positioning during surgery. This is all primarily gone away except for a little bit of numbness at the tip of the third digit as well as some occasional forearm muscle cramping. I told her that I felt that this would continue to improve as it has done over the past two months since her surgery. I told her to continue doing hand exercises as she has been doing and this seems to be working for her. Overall, I think she has healed from her surgery and is doing very well. Again, her quality of life is significantly improved. She is happy with her performance. We will see her back in six months just for a general routine checkup and see how she is doing at that time. | soap / chart / progress notes, perineal wound, wound infection, wound, wound check, ulcerative colitis, apr, ileostomyNOTE |
1,290 | Followup on weight loss on phentermine. | SOAP / Chart / Progress Notes | Weight Loss on Phentermine | SUBJECTIVE:, She is here for a followup on her weight loss on phentermine. She has gained another pound since she was here last. We talked at length about the continued plateau she has had with her weight. She gained a pound the month before and really has not been able to get her weight any farther down than she had when her lowest level was 136. She is frustrated with this as well. We agree that if she continues to plateau she really should not stay on phentermine. We would not want her to take it to maintain her weight but only to help her get her weight down, and she may have really lost any benefit from it, and she agrees.,REVIEW OF SYSTEMS:, Otherwise negative. She has no specific complaints. No shortness of breath, chest pain or palpitations.,PHYSICAL EXAM:,Vital signs: Her blood pressure is fine. Her diastolic is a little bit high, but otherwise okay.,General: She appears in good spirits. No apparent distress.,HEENT: Negative.,Neck: Supple without bruits.,Chest: Clear.,Cardiac exam: Regular without extra sounds.,ASSESSMENT:, Weight loss on phentermine, really has plateaued.,PLAN:, If she does not lose weight in the next month we will probably consider having her go off the phentermine. If she does lose a couple of pounds, then we will keep her on it until she gets closer to her goal of 135 and then try to keep her there for one or two months and then stop. She agrees with this plan. | soap / chart / progress notes, followup, phentermine, plateau, weight, weight loss, weight loss on phentermine, loss |
1,291 | Chronic laryngitis, hoarseness. The patient was referred to Medical Center's Outpatient Rehabilitation Department for skilled speech therapy secondary to voicing difficulties. | Speech - Language | Laryngitis - Discharge | DIAGNOSIS: , Chronic laryngitis, hoarseness.,HISTORY: ,The patient is a 68-year-old male, was referred to Medical Center's Outpatient Rehabilitation Department for skilled speech therapy secondary to voicing difficulties. The patient attended initial evaluation plus 3 outpatient speech therapy sessions, which focused on training the patient to complete resonant voice activities and to improve his vocal hygiene. The patient attended therapy one time a week and was given numerous home activities to do in between therapy sessions. The patient made great progress and he came in to discuss with an appointment on 12/23/08 stating that his voice had finally returned to "normal".,SHORT-TERM GOALS:,1. To be independent with relaxation and stretching exercises and Lessac-Madsen Resonant Voice Therapy Protocol.,2. He also met short-term goal therapy 3 and he is independent with resonant voice therapy tasks.,3. We did not complete his __________ ratio during his last session; so, I am unsure if he had met his short-term goal number 2.,4. To be referred for a videostroboscopy, but at this time, the patient is not in need of this evaluation. However, in the future if hoarseness returns, it is strongly recommended that he be referred for a videostroboscopy prior to returning to additional outpatient therapy.,LONG-TERM GOALS:,1. The patient did reach his long-term goal of improved vocal quality to return to prior level of function and to utilize his voice in all settings without vocal hoarseness or difficulty.,2. The patient appears very pleased with his return of his normal voice and feels that he no longer needs outpatient skilled speech therapy.,The patient is discharged from my services at this time with a home program to continue to promote normal voicing. | speech - language, vocal hygiene, voice activities, hoarseness, skilled speech therapy, chronic laryngitis, voice therapy, resonant voice, videostroboscopy, laryngitis |
1,292 | Speech - Language | Barium Swallow Study & Speech Evaluation - 1 | SUBJECTIVE: , The patient is a 60-year-old female, who complained of coughing during meals. Her outpatient evaluation revealed a mild-to-moderate cognitive linguistic deficit, which was completed approximately 2 months ago. The patient had a history of hypertension and TIA/stroke. The patient denied history of heartburn and/or gastroesophageal reflux disorder. A modified barium swallow study was ordered to objectively evaluate the patient's swallowing function and safety and to rule out aspiration.,OBJECTIVE: , Modified barium swallow study was performed in the Radiology Suite in cooperation with Dr. ABC. The patient was seated upright in a video imaging chair throughout this assessment. To evaluate the patient's swallowing function and safety, she was administered graduated amounts of liquid and food mixed with barium in the form of thin liquid (teaspoon x2, cup sip x2); nectar-thick liquid (teaspoon x2, cup sip x2); puree consistency (teaspoon x2); and solid food consistency (1/4 cracker x1).,ASSESSMENT,ORAL STAGE:, Premature spillage to the level of the valleculae and pyriform sinuses with thin liquid. Decreased tongue base retraction, which contributed to vallecular pooling after the swallow.,PHARYNGEAL STAGE: , No aspiration was observed during this evaluation. Penetration was noted with cup sips of thin liquid only. Trace residual on the valleculae and on tongue base with nectar-thick puree and solid consistencies. The patient's hyolaryngeal elevation and anterior movement are within functional limits. Epiglottic inversion is within functional limits.,CERVICAL ESOPHAGEAL STAGE: ,The patient's upper esophageal sphincter opening is well coordinated with swallow and readily accepted the bolus. Radiologist noted reduced peristaltic action of the constricted muscles in the esophagus, which may be contributing to the patient's complaint of globus sensation.,DIAGNOSTIC IMPRESSION:, No aspiration was noted during this evaluation. Penetration with cup sips of thin liquid. The patient did cough during this evaluation, but that was noted related to aspiration or penetration.,PROGNOSTIC IMPRESSION: ,Based on this evaluation, the prognosis for swallowing and safety is good.,PLAN: , Based on this evaluation and following recommendations are being made:,1. The patient to take small bite and small sips to help decrease the risk of aspiration and penetration.,2. The patient should remain upright at a 90-degree angle for at least 45 minutes after meals to decrease the risk of aspiration and penetration as well as to reduce her globus sensation.,3. The patient should be referred to a gastroenterologist for further evaluation of her esophageal function.,The patient does not need any skilled speech therapy for her swallowing abilities at this time, and she is discharged from my services. | speech - language, gastroesophageal reflux disorder, cognitive linguistic deficit, tia, stroke, swallowing function, swallow study, barium swallow study, globus sensation, esophageal, penetration |
|
1,293 | Comes in complaining that he was stung by a Yellow Jacket Wasp yesterday and now has a lot of swelling in his right hand and right arm. | SOAP / Chart / Progress Notes | Wasp Sting - SOAP | SUBJECTIVE:, He is a 29-year-old white male who is a patient of Dr. XYZ and he comes in today complaining that he was stung by a Yellow Jacket Wasp yesterday and now has a lot of swelling in his right hand and right arm. He says that he has been stung by wasps before and had similar reactions. He just said that he wanted to catch it early before he has too bad of a severe reaction like he has had in the past. He has had a lot of swelling, but no anaphylaxis-type reactions in the past; no shortness of breath or difficultly with his throat feeling like it is going to close up or anything like that in the past; no racing heart beat or anxiety feeling, just a lot of localized swelling where the sting occurs.,OBJECTIVE:,Vitals: His temperature is 98.4. Respiratory rate is 18. Weight is 250 pounds.,Extremities: Examination of his right hand and forearm reveals that he has an apparent sting just around his wrist region on his right hand on the medial side as well as significant swelling in his hand and his right forearm; extending up to the elbow. He says that it is really not painful or anything like that. It is really not all that red and no signs of infection at this time.,ASSESSMENT:, Wasp sting to the right wrist area.,PLAN:,1. Solu-Medrol 125 mg IM X 1.,2. Over-the-counter Benadryl, ice and elevation of that extremity.,3. Follow up with Dr. XYZ if any further evaluation is needed. | soap / chart / progress notes, yellow jacket wasp, wasp sting, swelling, solu-medrol, lot of swelling, stung, sting, wasp, |
1,294 | Evaluation of possible tethered cord. She underwent a lipomyomeningocele repair at 3 days of age and then again at 3-1/2 years of age. | SOAP / Chart / Progress Notes | Tethered Cord Evaluation | REASON FOR VISIT: , The patient referred by Dr. X for evaluation of her possible tethered cord.,HISTORY OF PRESENT ILLNESS:, Briefly, she is a 14-year-old right handed female who is in 9th grade, who underwent a lipomyomeningocele repair at 3 days of age and then again at 3-1/2 years of age. The last surgery was in 03/95. She did well; however, in the past several months has had some leg pain in both legs out laterally, worsening at night and requiring Advil, Motrin as well as Tylenol PM.,Denies any new bowel or bladder dysfunction or increased sensory loss. She had some patchy sensory loss from L4 to S1.,MEDICATIONS: , Singulair for occasional asthma.,FINDINGS: , She is awake, alert, and oriented x 3. Pupils equal and reactive. EOMs are full. Motor is 5 out of 5. She was able to toe and heel walk without any difficulties as well as tendon reflexes were 2 plus. There is no evidence of clonus. There is diminished sensation from L4 to S1, having proprioception.,ASSESSMENT AND PLAN: , Possible tethered cord. I had a thorough discussion with the patient and her parents. I have recommended a repeat MRI scan. The prescription was given today. MRI of the lumbar spine was just completed. I would like to see her back in clinic. We did discuss the possible symptoms of this tethering. | soap / chart / progress notes, tethering, lipomyomeningocele repair, sensory loss, tethered cord, mri, cord, lipomyomeningocele, |
1,295 | Sore throat - Upper respiratory infection. | SOAP / Chart / Progress Notes | URI - SOAP | SUBJECTIVE:, Mom brings patient in today because of sore throat starting last night. Eyes have been very puffy. He has taken some Benadryl when all of this congestion started but with a sudden onset just yesterday. He has had low-grade fever and just felt very run down, appearing very tired. He is still eating and drinking well, and his voice has been hoarse but no coughing. No shortness of breath, vomiting, diarrhea or abdominal pain.,PAST MEDICAL HISTORY:, Unremarkable. There is no history of allergies. He does have some history of some episodes of high blood pressure, and his weight is up about 14 pounds from the last year.,FAMILY HISTORY: , Noncontributory. No one else at home is sick.,OBJECTIVE:,General: A 13-year-old male appearing tired but in no acute distress.,Neck: Supple without adenopathy.,HEENT: Ear canals clear. TMs, bilaterally, gray in color. Good light reflex. Oropharynx pink and moist. No erythema or exudate. Some drainage is seen in the posterior pharynx. Nares: Swollen, red. No drainage seen. No sinus tenderness. Eyes are clear.,Chest: Respirations are regular and nonlabored.,Lungs: Clear to auscultation throughout.,Heart: Regular rhythm without murmur.,Skin: Warm, dry and pink, moist mucous membranes. No rash.,LABORATORY:, Strep test is negative. Strep culture is negative.,RADIOLOGY:, Water's View of the sinuses is negative for any sinusitis or acute infection.,ASSESSMENT:, Upper respiratory infection.,PLAN:, At this point just treat symptomatically. I gave him some samples of Levall for the congestion and as an expectorant. Push fluids and rest. May use ibuprofen or Tylenol for discomfort. | soap / chart / progress notes, soap, uri, upper respiratory infection, water's view, congestion, light reflex, sore throat, respiratory, strep, infection, |
1,296 | Postoperative day #1, total abdominal hysterectomy. Normal postoperative course. | SOAP / Chart / Progress Notes | Total Abdominal Hysterectomy - Followup | POSTOPERATIVE DAY #1, TOTAL ABDOMINAL HYSTERECTOMY,SUBJECTIVE: , The patient is alert and oriented x3 and sitting up in bed. The patient has been ambulating without difficulty. The patient is still NPO. The patient denies any new symptomatology from 6/10/2009. The patient has complaints of incisional tenderness. The patient was given a full explanation about her clinical condition and all her questions were answered.,OBJECTIVE:,VITAL SIGNS: Afebrile now. Other vital signs are stable.,GU: Urinating through Foley catheter.,ABDOMEN: Soft, negative rebound.,EXTREMITIES: Without Homans, nontender.,BACK: Without CVA tenderness.,GENITALIA: Vagina, slight spotting. Wound dry and intact.,ASSESSMENT:, Normal postoperative course.,PLAN:,1. Follow clinically.,2. Continue present therapy.,3. Ambulate with nursing assistance only., | soap / chart / progress notes, postoperative course, total abdominal hysterectomy, postoperative |
1,297 | The patient comes for three-week postpartum checkup, complaining of allergies. | SOAP / Chart / Progress Notes | Three-Week Postpartum Checkup | CHIEF COMPLAINT:, The patient comes for three-week postpartum checkup, complaining of allergies.,HISTORY OF PRESENT ILLNESS:, She is doing well postpartum. She has had no headache. She is breastfeeding and feels like her milk is adequate. She has not had much bleeding. She is using about a mini pad twice a day, not any cramping or clotting and the discharge is turned from red to brown to now slightly yellowish. She has not yet had sexual intercourse. She does complain that she has had a little pain with the bowel movement, and every now and then she notices a little bright red bleeding. She has not been particularly constipated but her husband says she is not eating her vegetables like she should. Her seasonal allergies have back developed and she is complaining of extremely itchy watery eyes, runny nose, sneezing, and kind of a pressure sensation in her ears.,MEDICATIONS:, Prenatal vitamins.,ALLERGIES:, She thinks to Benadryl.,FAMILY HISTORY: , Mother is 50 and healthy. Dad is 40 and healthy. Half-sister, age 34, is healthy. She has a sister who is age 10 who has some yeast infections.,PHYSICAL EXAMINATION:,VITALS: Weight: 124 pounds. Blood pressure 96/54. Pulse: 72. Respirations: 16. LMP: 10/18/03. Age: 39.,HEENT: Head is normocephalic. Eyes: EOMs intact. PERRLA. Conjunctiva clear. Fundi: Discs flat, cups normal. No AV nicking, hemorrhage or exudate. Ears: TMs intact. Mouth: No lesion. Throat: No inflammation. She has allergic rhinitis with clear nasal drainage, clear watery discharge from the eyes.,Abdomen: Soft. No masses.,Pelvic: Uterus is involuting.,Rectal: She has one external hemorrhoid which has inflamed. Stool is guaiac negative and using anoscope, no other lesions are identified.,ASSESSMENT/PLAN:, Satisfactory three-week postpartum course, seasonal allergies. We will try Patanol eyedrops and Allegra 60 mg twice a day. She was cautioned about the possibility that this may alter her milk supply. She is to drink extra fluids and call if she has problems with that. We will try ProctoFoam HC. For the hemorrhoids, also increase the fiber in her diet. That prescription was written, as well as one for Allegra and Patanol. She additionally will be begin on Micronor because she would like to protect herself from pregnancy until her husband get scheduled in and has a vasectomy, which is their ultimate plan for birth control, and she anticipates that happening fairly soon. She will call and return if she continues to have problems with allergies. Meantime, rechecking in three weeks for her final six-week postpartum checkup. | soap / chart / progress notes, checkup, allergies, postpartum, complaining of allergies, seasonal allergies, postpartum checkup, |
1,298 | Essential thrombocytosis. He underwent a bone marrow biopsy, which showed essential thrombocytosis. His CBC has been very stable. | SOAP / Chart / Progress Notes | Thrombocytosis Followup | CHIEF COMPLAINT:, Essential thrombocytosis.,HISTORY OF PRESENT ILLNESS: , This is an extremely pleasant 64-year-old gentleman who I am following for essential thrombocytosis. He was first diagnosed when he first saw a hematologist on 07/09/07. At that time, his platelet count was 1,240,000. He was initially started on Hydrea 1000 mg q.d. On 07/11/07, he underwent a bone marrow biopsy, which showed essential thrombocytosis. He was positive for the JAK-2 mutation. On 11/06/07, his platelets were noted to be 766,000. His current Hydrea dose is now 1500 mg on Mondays and Fridays and 1000 mg on all other days. He moved to ABCD in December 2009 in an attempt to improve his wife's rheumatoid arthritis.,Overall, he is doing well. He has a good energy level, and his ECOG performance status is 0. He denies any fevers, chills, or night sweats. No lymphadenopathy. No nausea or vomiting. No change in bowel or bladder habits.,CURRENT MEDICATIONS: , Hydrea 1500 mg on Mondays and Fridays and 1000 mg the other days of the week, Flomax q.d., vitamin D q.d, saw palmetto q.d., aspirin 81 mg q.d., and vitamin C q.d.,ALLERGIES: , No known drug allergies.,REVIEW OF SYSTEMS:, As per the HPI, otherwise negative.,PAST MEDICAL HISTORY:,1. He is status post an appendectomy.,2. Status post a tonsillectomy and adenoidectomy.,3. Status post bilateral cataract surgery.,4. BPH.,SOCIAL HISTORY: ,He has a history of tobacco use, which he quit at the age of 37. He has one alcoholic drink per day. He is married. He is a retired lab manager.,FAMILY HISTORY: ,There is no history of solid tumor or hematologic malignancies in his family.,PHYSICAL EXAM:,VIT: | null |
1,299 | Patient with immune thrombocytopenia | SOAP / Chart / Progress Notes | Thrombocytopenia - SOAP Note | SUBJECTIVE: , I am following the patient today for immune thrombocytopenia. Her platelets fell to 10 on 01/09/07 and shortly after learning of that result, I increased her prednisone to 60 mg a day. Repeat on 01/16/07 revealed platelets up at 43. No bleeding problems have been noted. I have spoken with her hematologist who recommends at this point we decrease her prednisone to 40 mg for 3 days and then go down to 20 mg a day. The patient had been on 20 mg every other day at least for a while, and her platelets hovered at least above 20 or so.,PHYSICAL EXAMINATION: , Vitals: As in chart. The patient is alert, pleasant, and cooperative. She is in no apparent distress. The petechial areas on her legs have resolved.,ASSESSMENT AND PLAN: , Patient with improvement of her platelet count on burst of prednisone. We will decrease her prednisone to 40 mg for 3 days, then go down to 20 mg a day. Basically thereafter, over time, I may try to sneak it back a little bit further. She is on medicines for osteoporosis including bisphosphonate and calcium with vitamin D. We will arrange to have a CBC drawn weekly., | soap / chart / progress notes, platelets, platelet count, thrombocytopenia, prednisone, |