Unnamed: 0
int64
1
139
ID
stringlengths
7
12
Sentence
stringlengths
63
557
Detected as
stringclasses
2 values
101
railway#50
Throughout the duration of the shunting group call, <referential>it</referential> shall be possible for any member of the shunting group to speak to all other members of the group, using the PTT function (as described in sections 5.2.2.53, 6.2.2.12 and 7.2.2.20), except during transmission of the link assurance signal.
NOCUOUS
102
railway#51
The shunting leader can then choose the moment when <referential>he</referential> takes or rejects the call.
INNOCUOUS
103
railway#52
In this case, the safety device will alert the driver only if the link assurance signal has failed or if <referential>it</referential> is cancelled.
INNOCUOUS
104
railway#53
The 300ms represents <referential>our</referential> current best estimate of the QoS figure, although this will need to be confirmed through user trials.
NOCUOUS
105
railway#54
Each authority can decide whether <referential>it</referential> wishes to use synchronised BTSs.
INNOCUOUS
106
railway#55
The network shall terminate the ongoing VGCS/VBS call if <referential>it</referential> receives the 3-digit sequence “***” transmitted via DTMF signals.
NOCUOUS
107
railway#56
The network shall send the SET-PARAMETER message with the attribute “D-ATT = T”1 [EN 301 515, Index [6]] to the mobile station of the talking subscriber if <referential>it</referential> receives the 3- digit sequence “###” transmitted via DTMF or the group call SETUP message2 from a controller terminal.
NOCUOUS
108
railway#57-1
When the network has detected the 3-digit DTMF sequence “###” transmitted via DTMF from a controller terminal and if the controller was not previously talking <referential>it</referential> should indicate its recognition by playing a single DTMF grant tone “#” of duration of 100ms  5ms to be sent to that controller terminal only.
NOCUOUS
109
railway#57-2
When the network has detected the 3-digit DTMF sequence “###” transmitted via DTMF from a controller terminal and if the controller was not previously talking it should indicate <referential>its</referential> recognition by playing a single DTMF grant tone “#” of duration of 100ms  5ms to be sent to that controller terminal only.
NOCUOUS
110
railway#58
The network shall send the SET-PARAMETER message with the attribute “D-ATT = F”3 [EN 301 515, Index [6]] to the mobile of the talking subscriber only if <referential>it</referential> has received the 3-digit sequence “#**” transmitted via DTMF from all the talking controllers4.
NOCUOUS
111
railway#59
Many of the railway specific standards referenced are Pre-standards (eg [prEN 50155, ENV 50121, prEN 50125]) and should be re-examined for <referential>their</referential> applicability to the EIRENE system if any modifications are made to these standards in the future.
INNOCUOUS
112
railway#60
Each of the other cabs on the train will be contacted using <referential>its</referential> functional number (registered by the other drivers prior to the establishment of the call).
NOCUOUS
113
railway#61
Upon registration, the mobile shall be accessible by calling the MSISDN or the Engine or Coach number with which <referential>it</referential> is associated.
INNOCUOUS
114
railway#62
The Cab radio system shall provide a means for the driver to terminate established calls which <referential>he</referential> is authorised to terminate.
INNOCUOUS
115
home#01
The DigitalHome programmable Appliance Manager shall provide for management of a home’s small appliances, including lighting units, by allowing a user to turn <referential>them</referential> on or off as desired.
NOCUOUS
116
home#02
Although the product produced under this document will be a “prototype” version, all modules and components of this prototype version shall be designed and implemented in such a manner that <referential>it</referential> may be incorporated in a fully specified commercial version of the DigitalHome System.
NOCUOUS
117
home#03
The DigitalHome System shall provide users with online documentation about the DigitalHome system installed in <referential>their</referential> home.
INNOCUOUS
118
space#01
The FCP shall, if the NEFU ICP fails to send <referential>its</referential> ICP Ready signal, mask out that ICP, but continue to use the NE.16.
INNOCUOUS
119
space#02
Each rate group has some number of tasks associated with <referential>it</referential>, and <referential>it</referential> also has a rate for those tasks.
INNOCUOUS
120
space#03
The enabled tasks are then unblocked at the rate given in <referential>its</referential> associated rate group.
NOCUOUS
121
space#04-1
An API call is available for the task to call to block <referential>itself</referential> when it is finished with its cyclic processing.
NOCUOUS
122
space#04-2
An API call is available for the task to call to block itself when <referential>it</referential> is finished with its cyclic processing.
NOCUOUS
123
space#04-3
An API call is available for the task to call to block itself when it is finished with <referential>its</referential> cyclic processing.
NOCUOUS
124
space#05
There is up to a full major frame from notification of an impending mode change to acting on <referential>it</referential> in minor frame 0 of the next major frame plus the time <referential>it</referential> takes during the next minor frame 0 to switch tasking.
NOCUOUS
125
space#06
The scheduler shall execute cyclic tasks, providing an API call to allow the application to block until <referential>its</referential> next iteration.
NOCUOUS
126
space#07
The scheduler shall give tasks priority values according to <referential>their</referential> rate - the higher the rate, the higher the priority.
NOCUOUS
127
space#08
The scheduler shall provide a mechanism to inform a task when <referential>it</referential> did not complete during the previous frame and restart <referential>it</referential> at the beginning of the task.
NOCUOUS
128
space#09
All tasks in rate groups and <referential>their</referential> corresponding schedules for all vehicle modes will be setup at system initialization.
NOCUOUS
129
space#10
Tasks in a rate group must suspend on a scheduler API call at the top of <referential>their</referential> execution loop.
INNOCUOUS
130
space#11
For hardware exceptions and reserved exceptions, the FTSS shall make the error type and <referential>its</referential> context data available to the application, then return from the exception handler to the task that was running when the exception occurred.
NOCUOUS
131
space#12
Messages are addressed with a global unique communication identifier that routes <referential>them</referential> to the appropriate virtual group (VG) and socket.
INNOCUOUS
132
space#13
This restriction does NOT apply to the ICPs since <referential>they</referential> are running as simplex VGs.
INNOCUOUS
133
space#14
The FTSS shall mask out a babbling NE or ICP within 40 milliseconds after <referential>it</referential> is detected.
NOCUOUS
134
space#15
Synchronous message passing sockets shall queue outgoing messages until <referential>they</referential> are transmitted at frame boundaries.
NOCUOUS
135
space#16
"Pipes may be opened by multiple receiving tasks if <referential>they</referential> are created with the broadcast"" capability; otherwise <referential>they</referential> may only be opened by one receiving task."""
NOCUOUS
136
space#17
"Communication services shall provide the capability to create pipe""s which ""broadcast"" <referential>their</referential> messages to all virtual groups."""
NOCUOUS
137
space#18
If the broadcast option is used, each virtual group should open the pipe and read from <referential>it</referential> to avoid flow control problems.
NOCUOUS
138
space#19
The application software shall have the capability to reset a permanently failed channel to <referential>its</referential> initial recovery state.
NOCUOUS
139
space#20
Redundancy Management picks up where <referential>it</referential> left off in these attempts.
INNOCUOUS