88e23b46-22d9-4be6-87b7-40541f7995a9
|
A building shall be provided with a permanently installed dry riser that is suitable for its purpose for transporting water for fire extinguishing: 1) in the premises above the entry level of the building, when the distance of the uppermost floor level from the entry level exceeds 24 metres; 2) in the premises below the entry level of the building, when the distance of the basement storey floor from the entry level exceeds 14 metres.
|
{'ID': '254_Finnish_FireSafety'}
|
A <e1>building</e1> shall be provided with a permanently installed dry riser that is suitable for its purpose for transporting water for fire extinguishing: 1) in the premises above the entry level of the building, when the distance of the uppermost floor level from the entry level exceeds 24 metres; 2) in the <e2>premises</e2> below the entry level of the building, when the distance of the basement storey floor from the entry level exceeds 14 metres.
|
part-of
|
825053cb-af5d-43a9-b59b-e2a5ae78ea73
|
The total number of associated parking spaces which have access to either: a. cable routes; b. an electric vehicle charge point should be the greater of the following: a. the number of dwellings in the residential building; b. the number of associated parking spaces.
|
{'ID': '59_UK_DocS_InfrastructureForChargingOfElectricalVehicles'}
|
The total number of <e1>associated</e1> <e2>parking spaces</e2> which have access to either: a. cable routes; b. an electric vehicle charge point should be the greater of the following: a. the number of dwellings in the residential building; b. the number of associated parking spaces.
|
selection
|
40b40b1b-d1b1-49d8-b9b7-13c5845a169d
|
The structure of the control appliance of the plumbing fixture shall be such that its surface temperature does not arise above 40 degrees Celsius.
|
{'ID': '71_Finnish_Health-WaterAndSewerage'}
|
The structure of the control appliance of the <e1>plumbing fixture</e1> shall be such that its <e2>surface temperature</e2> does not arise above 40 degrees Celsius.
|
none
|
c72a5952-2e0b-4d4a-9185-09e4149b6239
|
The flooring functioning as waterproofing or waterproofing located underneath the flooring in wet rooms must have a watertight connection with the waterproofing of the wall.
|
{'ID': '114_Finnish_Health-Humidity'}
|
The flooring functioning as waterproofing or <e1>waterproofing</e1> located underneath the flooring in wet rooms must have a <e2>watertight connection</e2> with the waterproofing of the wall.
|
necessity
|
8719164e-370a-42f2-9240-0a1b8db1a2c7
|
Extensive voids must be partitioned in order to restrict the spread of fire.
|
{'ID': '129_Finnish_FireSafety'}
|
Extensive <e1>voids</e1> must be <e2>partitioned</e2> in order to restrict the spread of fire.
|
necessity
|
2f0f22aa-06d3-478d-a777-5aca5c2fb5c1
|
For sliding doors and gates, provide both of the following: (i) a stop or other effective means to prevent them coming off the end of the track; (ii) a retaining rail to prevent doors and gates falling if the suspension system fails or the rollers leave the track.
|
{'ID': '120_UK_DocK_ProtectionFromFalling'}
|
For sliding doors and <e1>gates</e1>, provide both of the following: (i) a stop or other effective means to prevent them coming off the end of the track; (ii) a <e2>retaining rail</e2> to prevent doors and gates falling if the suspension system fails or the rollers leave the track.
|
necessity
|
4b510cad-fefb-44be-a9cb-a26e0c42994c
|
If the building is connected to a heating system where heat is conveyed via heat pipes external to the building from a shared heat exchanger or heat generation unit to several buildings, the heat loss from those pipes shall be divided between the buildings in proportion to their areas.
|
{'ID': '101_Finnish_EnergyEfficiency'}
|
If the building is connected to a <e1>heating system</e1> where <e2>heat</e2> is conveyed via heat pipes external to the building from a shared heat exchanger or heat generation unit to several buildings, the heat loss from those pipes shall be divided between the buildings in proportion to their areas.
|
part-of
|
f162906e-1097-420e-b2a0-dd746d5794c7
|
Where controls are external to the heater, the system should be provided with a time switch/programmer and room thermostat, or programmable room thermostat.
|
{'ID': '265_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
Where <e1>controls</e1> are external to the heater, the system should be provided with a time switch/programmer and room thermostat, or programmable <e2>room thermostat</e2>.
|
none
|
5f675f4f-74de-4d0f-ae92-c3500d2d952e
|
The actual equivalent area and location of installed background ventilators should be recorded.
|
{'ID': '189_UK_DocF_V1_Ventilation'}
|
The actual <e1>equivalent area</e1> and location of installed background ventilators should be <e2>recorded</e2>.
|
necessity
|
aaca648c-5f60-4300-a30f-887da252ebd0
|
The use of visually and acoustically reflective wall surfaces should be minimised within the lifting platform to prevent discomfort for people with visual and hearing impairment.
|
{'ID': '116_UK_DocM_V2_AccessAndUseOfBuildings'}
|
The <e1>use</e1> of visually and acoustically reflective wall surfaces should be <e2>minimised within the lifting platform to prevent discomfort for people with visual and hearing impairment</e2>.
|
necessity
|
b6e6ebce-e75f-4fae-b9a2-e35c164b3fb4
|
Where onsite electricity generation and storage is installed, such as photovoltaic panels or battery storage, systems should be an appropriate size for the site, available infrastructure and onsite energy demand.
|
{'ID': '342_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
Where onsite electricity generation and storage is installed, such as <e1>photovoltaic panels</e1> or <e2>battery storage</e2>, systems should be an appropriate size for the site, available infrastructure and onsite energy demand.
|
none
|
e9d02df9-2fcb-4acc-bd08-18a4348cd823
|
If people need to obtain tickets for pay and display parking, the ticket dispensing machines should be located in a way that allows a person in a wheelchair, or a person of short stature, to gain access close to the machine and reach the payment and ticket dispensing functions.
|
{'ID': '46_UK_DocM_V2_AccessAndUseOfBuildings'}
|
If <e1>people</e1> need to <e2>obtain tickets for pay and display parking</e2>, the ticket dispensing machines should be located in a way that allows a person in a wheelchair, or a person of short stature, to gain access close to the machine and reach the payment and ticket dispensing functions.
|
necessity
|
35af73f1-53c7-4377-9da0-acf99eef4d8e
|
WC compartment doors, and doors to wheelchair-accessible unisex toilets, changing rooms or shower rooms have an emergency release mechanism so that they are capable of being opened outwards, from the outside , in case of emergency.
|
{'ID': '159_UK_DocM_V2_AccessAndUseOfBuildings'}
|
<e1>WC compartment doors</e1>, and doors to wheelchair-accessible unisex toilets, changing rooms or shower rooms <e2>have an emergency release mechanism so that they are capable of being opened outwards, from the outside , in case of emergency</e2>.
|
necessity
|
53e31e26-a39b-4047-a86e-bdb8021413e8
|
Window handles on windows that open outwards are not more than 650mm from the inside face of the wall when the window is at its maximum openable angle.
|
{'ID': '84_UK_DocO_Overheating'}
|
<e1>Window handles</e1> on windows that open outwards are not more than <e2>650mm</e2> from the inside face of the wall when the window is at its maximum openable angle.
|
none
|
c2e0629d-350b-45b8-9e9e-d58be1780f12
|
If the basement has no bedrooms, it should be treated as having one bedroom when calculating the ventilation required for the purposes of meeting the ventilation standards.
|
{'ID': '73_UK_DocF_V1_Ventilation'}
|
If the basement has no bedrooms, it should be treated as having one bedroom when calculating the <e1>ventilation</e1> <e2>required for the purposes of meeting the ventilation standards</e2>.
|
selection
|
7faab614-f3bc-41b4-9dbf-0ff2b3ea56f3
|
Where the cost of installing only cable routes is more than 7% of the total cost of the major renovation, there is no requirement to install either electric vehicle charge points or cable routes.
|
{'ID': '53_UK_DocS_InfrastructureForChargingOfElectricalVehicles'}
|
Where the cost of installing only cable routes is more than <e1>7%</e1> of the <e2>total cost</e2> of the major renovation, there is no requirement to install either electric vehicle charge points or cable routes.
|
part-of
|
2f815a08-db3c-48a6-b248-d69aeac870ee
|
the vertical travel distance is: a. not more than 2m, where there is no liftway enclosure and no floor penetration; b. more than 2m, where there is a liftway enclosure.
|
{'ID': '173_UK_DocM_V2_AccessAndUseOfBuildings'}
|
the vertical <e1>travel distance</e1> is: a. not more than <e2>2m</e2>, where there is no liftway enclosure and no floor penetration; b. more than 2m, where there is a liftway enclosure.
|
less-equal
|
bde1697a-20c9-4f15-a63c-5be323a058c1
|
Any connection of two or more air handling units to the same duct or chamber shall be designed so that the pressures of the rooms or the directions of air flow between the rooms and in the ductworks do not change when the air flows of the units are being controlled.
|
{'ID': '90_Finnish_Health-IndoorClimateAndVentilation'}
|
Any connection of two or more air handling units to the same duct or chamber shall be designed so that the <e1>pressures</e1> of the rooms or the directions of air flow between the rooms and in the ductworks do <e2>not change when the air flows of the units are being controlled</e2>.
|
selection
|
d342429e-d3fc-46e0-a195-527cfef1fd4b
|
When an existing building with a total useful floor area of over 1000m2 is being extended or the habitable area is being increased, consequential improvements should be installed.
|
{'ID': '451_UK_DocM_V2_AccessAndUseOfBuildings'}
|
When an existing <e1>building</e1> with a total useful floor area of over <e2>1000m2</e2> is being extended or the habitable area is being increased, consequential improvements should be installed.
|
none
|
164122ed-c7ac-4cf8-8a54-3d56c144f78d
|
In general, the findings indicate that there should be at least the same number of WCs (for women) as urinals (for men) and for some building types, e.g. large retail buildings, at least twice as many.
|
{'ID': '172_UK_DocM_V2_AccessAndUseOfBuildings'}
|
In general, the findings indicate that there should be at least the same number of WCs (for women) as urinals (for men) and for some <e1>building</e1> types, e.g. large retail buildings, <e2>at least twice as many</e2>.
|
necessity
|
6414854d-01f9-481f-a7f4-c4581e48d8b1
|
Special safety features are not necessary if the ladder is not more than 6m long.
|
{'ID': '112_UK_DocK_ProtectionFromFalling'}
|
Special safety features are <e1>not necessary</e1> if the ladder is not more than 6m <e2>long</e2>.
|
none
|
43a7a088-718f-4a11-a392-88e71559466e
|
In exceptional circumstances in an existing building, a wheelchair platform stairlift may be considered, provided its installation does not conflict with requirements for means of escape.
|
{'ID': '107_UK_DocM_V2_AccessAndUseOfBuildings'}
|
In exceptional circumstances in an existing building, a <e1>wheelchair platform stairlift</e1> may be <e2>considered, provided its installation does not conflict with requirements for means of escape</e2>.
|
necessity
|
60024014-cb6a-4a53-9b12-9497e0a1e5e8
|
Extract air from toilets, washrooms and cleaning spaces may be conducted to vertical ducts for extract air categories 1 and 2 if the total extract air flow from these spaces does not exceed 10 of the total air flow in the vertical duct.
|
{'ID': '85_Finnish_Health-IndoorClimateAndVentilation'}
|
Extract air from toilets, washrooms and cleaning spaces may be conducted to vertical ducts for extract air categories 1 and 2 if the total extract air flow from these spaces does not exceed 10 of the total air flow in the <e1>vertical</e1> <e2>duct</e2>.
|
selection
|
d342429e-d3fc-46e0-a195-527cfef1fd4b
|
When an existing building with a total useful floor area of over 1000m2 is being extended or the habitable area is being increased, consequential improvements should be installed.
|
{'ID': '451_UK_DocM_V2_AccessAndUseOfBuildings'}
|
When an <e1>existing</e1> building with a total useful floor area of over 1000m2 is being extended or the <e2>habitable area</e2> is being increased, consequential improvements should be installed.
|
none
|
bfdf95da-d422-47cd-83d7-a30a4969f2e6
|
If the internal ties must be centred on the supporting line, the minimum value of the tie force, 10 kN, will also be applied to internal ties.
|
{'ID': '180_Finnish_StabilityOfStructures'}
|
If the internal ties must be centred on the supporting line, the minimum value of the tie force, 10 kN, will also be applied to <e1>internal</e1> <e2>ties</e2>.
|
selection
|
db734798-9e42-4fe1-900c-77d4e6131809
|
The main doors for entering a dwelling (usually the front door) should have a door viewer unless other means exist to see callers, such as clear glass within the door or a window next to the doorset.
|
{'ID': '11_UK_DocQ_Security_Dwellings'}
|
The main doors for entering a dwelling (usually the front door) should have a door viewer unless <e1>other</e1> means exist to see callers, such as clear glass within the door or a <e2>window</e2> next to the doorset.
|
none
|
5f675f4f-74de-4d0f-ae92-c3500d2d952e
|
The actual equivalent area and location of installed background ventilators should be recorded.
|
{'ID': '189_UK_DocF_V1_Ventilation'}
|
The actual equivalent area and <e1>location</e1> of installed background ventilators should be <e2>recorded</e2>.
|
necessity
|
4fc3b5b1-a838-4429-b385-d8e80e6633eb
|
In the absence of relevant harmonised European Standards, products with a travel exceeding 3m must have a product certificate issued by a Notified Body.
|
{'ID': '117_UK_DocM_V2_AccessAndUseOfBuildings'}
|
In the absence of relevant harmonised European Standards, <e1>products</e1> with a travel exceeding 3m must have a <e2>product certificate</e2> issued by a Notified Body.
|
necessity
|
f72a98f3-b7d2-4633-b244-0d7242dfb0c9
|
Every single bedroom has a minimum floor area of 8.5m2 and is at least 2.4m wide.
|
{'ID': '102_UK_DocM_V1_AccessAndUseOfBuildings'}
|
Every single bedroom has a minimum floor area of <e1>8.5m2</e1> and is at least 2.4m <e2>wide</e2>.
|
none
|
3e9fc57e-bc69-4f17-a056-dd7767afa9bb
|
If the height of the building does not exceed 28 metres, access to the attic fire compartments from the outside shall be required.
|
{'ID': '241_Finnish_FireSafety'}
|
If the <e1>height</e1> of the building does not exceed <e2>28 metres</e2>, access to the attic fire compartments from the outside shall be required.
|
less-equal
|
17fba530-c42b-4eeb-85dd-16da0bacc49c
|
Areas that are not enclosed, such as open floors, covered ways and balconies, should be excluded.
|
{'ID': '470_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
Areas that are <e1>not enclosed</e1>, such as <e2>open</e2> floors, covered ways and balconies, should be excluded.
|
none
|
8c4a09c5-1eb2-4a41-86d9-b69c031b4592
|
Ground arrays including header pipes and manifolds should be flushed as one system to remove all debris and purged to remove all air.
|
{'ID': '384_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
Ground arrays including header pipes and <e1>manifolds</e1> should be <e2>flushed as one system to remove all debris and purged to remove all air</e2>.
|
necessity
|
4e119abd-0cf7-4c60-9c7b-1083f9b46280
|
NOTE: If an exposed facade is close to an area of sustained and loud noise (e.g. a main road), then a noise attenuating background ventilator should be fitted.
|
{'ID': '85_UK_DocF_V2_Ventilation'}
|
NOTE: If an exposed facade is <e1>close to an area of sustained and loud noise (e.g. a main road)</e1>, then a noise attenuating <e2>background ventilator</e2> should be fitted.
|
necessity
|
371e1755-8bb5-456e-bf66-5a50f4c19d59
|
Where there is full-height structural guarding, if you provide a second (lower) handrail, the vertical height from the pitch line of the steps (or the surface of the ramp) to the top of the second (lower) handrail should be 600mm.
|
{'ID': '50_UK_DocK_ProtectionFromFalling'}
|
Where there is full-height structural guarding, if you provide a second (lower) handrail, the <e1>vertical</e1> <e2>height</e2> from the pitch line of the steps (or the surface of the ramp) to the top of the second (lower) handrail should be 600mm.
|
selection
|
87c9c5f5-18dc-4107-b4af-b44dfb2b9627
|
The effective rated output should be assessed based on the final installed capacity of the heating or air-conditioning system.
|
{'ID': '326_UK_DocM_V2_AccessAndUseOfBuildings'}
|
The <e1>effective</e1> <e2>rated output</e2> should be assessed based on the final installed capacity of the heating or air-conditioning system.
|
selection
|
a7e4ad57-ea09-4d8e-8b3a-4d33447237ab
|
The free opening of the vertical hatch or window of an emergency exit must be at least 600 millimetres in height and 500 millimetres in width; however, the sum of these must be at least 1,500 millimetres.
|
{'ID': '83_Finnish_SafetyOfUse'}
|
The free <e1>opening</e1> of the vertical hatch or window of an emergency exit must be at least 600 millimetres in height and 500 millimetres in width; however, the <e2>sum</e2> of these must be at least 1,500 millimetres.
|
part-of
|
5577528f-8fa0-4ca3-96f6-ea418091cb86
|
The side edges of stairs and landings must be fitted with a raised camber to prevent slipping over the edge if a cube measuring more than 50 millimetres in width is able to pass through the opening between the plane level and the handrail or wall.
|
{'ID': '32_Finnish_SafetyOfUse'}
|
The side edges of stairs and <e1>landings</e1> must be fitted with a raised camber to prevent slipping over the edge if a cube measuring more than 50 millimetres in width is <e2>able to pass through the opening between the plane level and the handrail or wall</e2>.
|
none
|
5869233a-4fc0-48bf-9007-2b0c9a169fef
|
A building shall, if its size, number of storeys or an intended purpose of a premises within the building so requires, be divided into fire compartments in order to restrict the spread of fire and smoke, to provide safe evacuation and to facilitate rescue and extinguishing measures.
|
{'ID': '100_Finnish_FireSafety'}
|
A building shall, if its size, number of storeys or an intended purpose of a premises within the building so requires, be <e1>divided into fire compartments</e1> in order to restrict the spread of fire and smoke, to <e2>provide safe evacuation</e2> and to facilitate rescue and extinguishing measures.
|
selection
|
3d0bbf85-327f-4f92-a468-201f81080779
|
The roof insulation should be installed when the eaves are still accessible.
|
{'ID': '169_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
The roof <e1>insulation</e1> should be <e2>installed when the eaves are still accessible</e2>.
|
necessity
|
6bf41e87-d7c1-42a5-bf0d-67c711a21753
|
Additionally, a sign identifying the floor reached should be provided on each landing in a location that can be easily seen from the lifting device and is designed so that it contrasts visually with its surrounding.
|
{'ID': '105_UK_DocM_V2_AccessAndUseOfBuildings'}
|
Additionally, a sign identifying the floor reached should be provided on each landing in a location that can be easily seen from the lifting device and is <e1>designed</e1> so that <e2>it contrasts visually with its surrounding</e2>.
|
selection
|
ec2e84a5-89bc-4c16-9a55-1965efd13981
|
Wall insulation should be installed to the top of the wall plate; in some places, such as the eaves, this may be above the cavity closure or barrier.
|
{'ID': '167_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
<e1>Wall</e1> <e2>insulation</e2> should be installed to the top of the wall plate; in some places, such as the eaves, this may be above the cavity closure or barrier.
|
part-of
|
bd033057-ac6c-45bb-92c7-ca58bf22dab1
|
The lobby should be large enough and of a shape to allow a wheelchair user or a person pushing a pram to move clear of one door before opening the second door.
|
{'ID': '80_UK_DocM_V2_AccessAndUseOfBuildings'}
|
The <e1>lobby</e1> should be <e2>large enough</e2> and of a shape to allow a wheelchair user or a person pushing a pram to move clear of one door before opening the second door.
|
necessity
|
6465e5b9-4c10-41ec-9839-3e7cb7114911
|
Programmable room thermostats with an override feature should be provided for all direct electric zones of the electric underfloor heating system.
|
{'ID': '314_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
<e1>Programmable</e1> <e2>room thermostats</e2> with an override feature should be provided for all direct electric zones of the electric underfloor heating system.
|
selection
|
a387fcb8-ead2-4094-9be9-72d783468b33
|
If the area of windows, roof windows, rooflights and doors exceeds 25 of the total floor area of the dwelling, compensating measures should be taken to improve the energy efficiency of the dwelling.
|
{'ID': '422_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
If the <e1>area</e1> of windows, roof windows, <e2>rooflights</e2> and doors exceeds 25 of the total floor area of the dwelling, compensating measures should be taken to improve the energy efficiency of the dwelling.
|
part-of
|
72e7ed0c-9e73-46b2-a919-20f3fea337fd
|
An area with a potentially flammable or explosive atmosphere must not be located in a building where there are dwellings, accommodation premises, institutions or assembly and business premises.
|
{'ID': '56_Finnish_FireSafety'}
|
An <e1>area</e1> with a potentially flammable or explosive <e2>atmosphere</e2> must not be located in a building where there are dwellings, accommodation premises, institutions or assembly and business premises.
|
part-of
|
385a4365-40c0-4c07-8854-b07bde292fd2
|
The electrical energy consumption of a mechanical ventilation system shall be calculated on the basis of air flows, specific fan powers and operating times for all air handling units and powered roof ventilators in the building.
|
{'ID': '109_Finnish_EnergyEfficiency'}
|
The electrical energy consumption of a <e1>mechanical</e1> <e2>ventilation system</e2> shall be calculated on the basis of air flows, specific fan powers and operating times for all air handling units and powered roof ventilators in the building.
|
selection
|
7134933d-17df-4a8c-b72e-1c09177bad1c
|
The spread of fire in voids of wall-type building elements must be restricted at least by storey.
|
{'ID': '130_Finnish_FireSafety'}
|
The <e1>spread of fire</e1> in voids of wall-type building elements must be <e2>restricted at least by storey</e2>.
|
necessity
|
3c28dbd6-8a3d-4ede-ae08-89e4b5d69d60
|
The approach route is a minimum of 900mm wide with a maximum cross fall of 1 in 40.
|
{'ID': '16_UK_DocM_V1_AccessAndUseOfBuildings'}
|
The <e1>approach route</e1> is a minimum of 900mm <e2>wide</e2> with a maximum cross fall of 1 in 40.
|
part-of
|
8207751f-13b8-4fe3-9bfe-4423093d4905
|
A building with dwellings or accommodation or patient rooms shall be designed and implemented so that the reverberation time of the staircase and exit route is no more than 1.3 seconds.
|
{'ID': '26_Finnish_AcousticEnvironment'}
|
A building with dwellings or <e1>accommodation</e1> or patient rooms shall be designed and implemented so that the reverberation time of the staircase and <e2>exit route</e2> is no more than 1.3 seconds.
|
none
|
835d8fad-7a27-4299-aa38-a5b1771a6779
|
In large building complexes, such as retail parks and large sports centres, there should be one wheelchair-accessible unisex toilet capable of including an adult changing table.
|
{'ID': '178_UK_DocM_V2_AccessAndUseOfBuildings'}
|
In large <e1>building complexes</e1>, such as retail parks and large <e2>sports centres</e2>, there should be one wheelchair-accessible unisex toilet capable of including an adult changing table.
|
selection
|
2c725d50-13d5-4e77-bacf-9f174530e27c
|
The energy efficiency of historic and traditional buildings should be improved only if doing so will not cause long-term deterioration of the buildings fabric or fittings.
|
{'ID': '17_UK_DocM_V2_AccessAndUseOfBuildings'}
|
The energy efficiency of historic and <e1>traditional</e1> <e2>buildings</e2> should be improved only if doing so will not cause long-term deterioration of the buildings fabric or fittings.
|
selection
|
8805ec9f-3f5f-44fc-9078-3ae62439c973
|
NOTE: When a single U-value is calculated for a product range of doors, the configuration of the door chosen for the calculation should be the worst performing in the product range.
|
{'ID': '108_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
NOTE: When a single U-value is calculated for a product range of doors, the configuration of the <e1>door</e1> chosen for the calculation should be the <e2>worst performing in the product range</e2>.
|
none
|
ee0c8c7c-c65e-4403-92e6-628fd680f3bf
|
Any panel within the doorset should be at least 15mm thick.
|
{'ID': '30_UK_DocQ_Security_Dwellings'}
|
Any <e1>panel</e1> within the doorset should be at least 15mm <e2>thick</e2>.
|
part-of
|
23cff3c3-1251-4c5f-9fd9-8f52d25eb494
|
Gasfired boilers and multi-stage oilfired boilers with an output of more than 500kW should have fully modulating burner controls.
|
{'ID': '252_UK_DocM_V2_AccessAndUseOfBuildings'}
|
<e1>Gasfired boilers</e1> and multi-stage oilfired boilers with an <e2>output</e2> of more than 500kW should have fully modulating burner controls.
|
selection
|
7d877df3-9aa7-4dff-a64d-5356a66c944d
|
In public outdoor and indoor spaces, and in business and service premises, a handrail must continue at least 300 millimetres past the start and end points of the structure, and in the case of stairs or ramps that have a width exceeding 2.4 metres and are located in assembly areas, it must also be placed so as to divide the passageway into parts no wider than the abovementioned width.
|
{'ID': '59_Finnish_SafetyOfUse'}
|
In public outdoor and indoor spaces, and in business and <e1>service</e1> premises, a handrail must <e2>continue at least 300 millimetres past the start and end points of the structure</e2>, and in the case of stairs or ramps that have a width exceeding 2.4 metres and are located in assembly areas, it must also be placed so as to divide the passageway into parts no wider than the abovementioned width.
|
none
|
bde1697a-20c9-4f15-a63c-5be323a058c1
|
Any connection of two or more air handling units to the same duct or chamber shall be designed so that the pressures of the rooms or the directions of air flow between the rooms and in the ductworks do not change when the air flows of the units are being controlled.
|
{'ID': '90_Finnish_Health-IndoorClimateAndVentilation'}
|
Any <e1>connection</e1> of two or more <e2>air handling units</e2> to the same duct or chamber shall be designed so that the pressures of the rooms or the directions of air flow between the rooms and in the ductworks do not change when the air flows of the units are being controlled.
|
part-of
|
726e23c9-02a3-4c56-98d0-8981b7ce877b
|
In the construction of a new building as well as in repair and alteration work corresponding to the construction of a new building, the premises to be fitted with a floor drain shall be: 1. showers and bathrooms as well as wash rooms in connection with saunas; 2. laundry room; 3. heat distribution room; 4. ventilation unit room; 5. toilet facility intended for public use; 6. technical utility room with a possibility to water damage; 7. car wash facility; 8. special facilities cleansed by water rinsing.
|
{'ID': '126_Finnish_Health-WaterAndSewerage'}
|
In the construction of a new building as well as in repair and alteration work corresponding to the construction of a new building, the <e1>premises</e1> to be fitted with a floor drain shall be: 1. showers and bathrooms as well as wash rooms in connection with saunas; 2. laundry room; 3. <e2>heat distribution room</e2>; 4. ventilation unit room; 5. toilet facility intended for public use; 6. technical utility room with a possibility to water damage; 7. car wash facility; 8. special facilities cleansed by water rinsing.
|
necessity
|
d5b6ff18-626d-4e6f-b788-0c67f7a4ebab
|
If the cost of installing the required electric vehicle charge point and cable routes for electric vehicle charge points exceeds 7% of the total cost of the major renovation (a) such a building is exempt from the requirement to install the electric vehicle charge point; and (b) cable routes for electric vehicle charge points must be installed in a minimum of one fifth of the total number of parking spaces, except where the cost of that installation exceeds 7% of the total cost of the major renovation.
|
{'ID': '75_UK_DocS_InfrastructureForChargingOfElectricalVehicles'}
|
If the cost of installing the required electric vehicle charge point and cable routes for electric vehicle charge points exceeds 7% of the total cost of the major <e1>renovation</e1> (a) such a building is exempt from the requirement to install the electric vehicle charge point; and (b) cable routes for electric vehicle charge points must be installed in a minimum of one fifth of the total number of parking spaces, except where the cost of that installation exceeds 7% of the total cost of the major <e2>renovation</e2>.
|
none
|
2f0f22aa-06d3-478d-a777-5aca5c2fb5c1
|
For sliding doors and gates, provide both of the following: (i) a stop or other effective means to prevent them coming off the end of the track; (ii) a retaining rail to prevent doors and gates falling if the suspension system fails or the rollers leave the track.
|
{'ID': '120_UK_DocK_ProtectionFromFalling'}
|
For sliding <e1>doors</e1> and gates, provide both of the following: (i) a stop or other effective <e2>means</e2> to prevent them coming off the end of the track; (ii) a retaining rail to prevent doors and gates falling if the suspension system fails or the rollers leave the track.
|
selection
|
3f4eef4b-2dc5-4746-8791-3a37360d6e8a
|
All people should be able to use presentation facilities.
|
{'ID': '134_UK_DocM_V2_AccessAndUseOfBuildings'}
|
All <e1>people</e1> should be <e2>able to use presentation facilities</e2>.
|
necessity
|
7d1ada0b-8dcc-4c01-84d7-78b80cb404c9
|
If there are not enough associated parking spaces outside of the covered car park to meet the requirement to install electric vehicle charge points, then cable routes should be installed for associated parking spaces within the covered car park.
|
{'ID': '58_UK_DocS_InfrastructureForChargingOfElectricalVehicles'}
|
If there are <e1>not enough</e1> associated parking spaces outside of the covered car park to <e2>meet the requirement to install electric vehicle charge points</e2>, then cable routes should be installed for associated parking spaces within the covered car park.
|
selection
|
319372c4-2f9b-4594-8150-b9fd2c7670c4
|
A stack vent located in cold premises shall be thermally insulated.
|
{'ID': '136_Finnish_Health-WaterAndSewerage'}
|
A <e1>stack vent</e1> located in cold premises shall be <e2>thermally insulated</e2>.
|
necessity
|
8feaf7f2-dfd8-43ae-ab8d-791ee1ffd86c However, if the elevation difference is no more than 1,000 millimetres, the ramp may not have a gradient of more than eight per cent. {'ID': '9_Finnish_Accessibility'}
|
However, if the elevation difference is no more than 1,000 millimetres, the ramp may not have a gradient of more than eight per cent.
|
{'ID': '9_Finnish_Accessibility'}
|
However, if the <e1>elevation difference</e1> is no more than <e2>1,000 millimetres</e2>, the ramp may not have a gradient of more than eight per cent.
|
less-equal
|
c0a6d35c-cc20-428b-941d-c3e3e6365c74
|
In a tier that is uninterrupted by cross-gangways, and where the pitch exceeds 25, use a maximum number of steps of 40.
|
{'ID': '25_UK_DocK_ProtectionFromFalling'}
|
In a tier that is uninterrupted by cross-gangways, and where the <e1>pitch</e1> exceeds 25, use a maximum <e2>number</e2> of steps of 40.
|
none
|
7f696221-52c9-4c52-8f90-74bd93c51299
|
This grippable handrail is 850-1000mm above the pitch line of the flight and extends at least 300mm beyond the top and bottom nosings.
|
{'ID': '73_UK_DocM_V1_AccessAndUseOfBuildings'}
|
This <e1>grippable handrail</e1> is 850-1000mm above the pitch line of the flight and <e2>extends</e2> at least 300mm beyond the top and bottom nosings.
|
part-of
|
636bce88-fd3b-4e5a-9f6a-4aa0d3d1bfa4
|
Where a new building contains more than one dwelling, a common access point for a gigabit-capable public electronic communications network is required as a part of the buildings gigabit-ready physical infrastructure.
|
{'ID': '6_UK_DocR_V1_InfrastructureForElectircalCommunications'}
|
Where a new building contains more than one dwelling, a <e1>common access point</e1> for a gigabit-capable public electronic communications network is required as a part of the buildings <e2>gigabit-ready physical infrastructure</e2>.
|
part-of
|
0a53e4af-84a7-46aa-b28a-cb1d873c8cae
|
The type and quality of public address, hearing enhancement and telephone systems should be chosen carefully to ensure intelligibility.
|
{'ID': '151_UK_DocM_V2_AccessAndUseOfBuildings'}
|
The <e1>type and quality</e1> of public address, hearing enhancement and telephone systems should be <e2>chosen carefully to ensure intelligibility</e2>.
|
necessity
|
64aead92-11dc-49ab-9086-c86f6d1f9c3e
|
A dynamic calculation tool shall be used for the calculation of the room temperature for the summer season.
|
{'ID': '162_Finnish_EnergyEfficiency'}
|
A dynamic <e1>calculation tool</e1> shall be used for the <e2>calculation of the room temperature for the summer season</e2>.
|
necessity
|
0fdce0b1-7992-401f-aa84-ad7f2acca23d
|
Cavity walls: the inner block leaf mortar joint should be fully filled and pointed within the cavity.
|
{'ID': '184_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
Cavity walls: the inner block leaf <e1>mortar joint</e1> should be <e2>fully filled</e2> and pointed within the cavity.
|
necessity
|
f6a682fb-f427-41d0-9219-3a45d2134be6
|
To correctly assess whether an element meets the limiting U-value, the U-value must be calculated for the element in the appropriate plane - either horizontal or vertical.
|
{'ID': '109_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
To correctly assess whether an element meets the limiting U-value, the <e1>U-value</e1> must be <e2>calculated for the element in the appropriate plane - either horizontal or vertical</e2>.
|
necessity
|
e43c1e88-be80-42d9-944e-1bf0f0f82479
|
Individual flights are: for gradients up to 1:15 not more than 10m long; for gradients up to 1:12 not more than 5m long.
|
{'ID': '18_UK_DocM_V1_AccessAndUseOfBuildings'}
|
Individual <e1>flights</e1> are: for <e2>gradients</e2> up to 1:15 not more than 10m long; for gradients up to 1:12 not more than 5m long.
|
selection
|
bfdf95da-d422-47cd-83d7-a30a4969f2e6
|
If the internal ties must be centred on the supporting line, the minimum value of the tie force, 10 kN, will also be applied to internal ties.
|
{'ID': '180_Finnish_StabilityOfStructures'}
|
If the internal ties must be <e1>centred on the supporting line</e1>, the minimum value of the tie force, <e2>10 kN</e2>, will also be applied to internal ties.
|
none
|
7e34700e-92de-4b00-a820-f4085a2e186c
|
If the free gap between facing walls of adjacent glazed balconies or the distance of the wall to the window of an adjacent fire compartment is less than 2 metres, the wall in question must be class EI 15.
|
{'ID': '135_Finnish_FireSafety'}
|
If the <e1>free gap</e1> between facing walls of adjacent glazed balconies or the distance of the wall to the window of an adjacent fire compartment is less than <e2>2 metres</e2>, the wall in question must be class EI 15.
|
less
|
8f2f0722-46e5-4c3a-937d-51edde58141a
|
Routes intended for vehicle traffic must be located in a way that does not restrict pedestrian routes or the space required for opening doors and gates.
|
{'ID': '90_Finnish_SafetyOfUse'}
|
<e1>Routes</e1> <e2>intended for vehicle traffic</e2> must be located in a way that does not restrict pedestrian routes or the space required for opening doors and gates.
|
selection
|
f009a781-0ced-408d-b3d1-6ae7a848012e
|
The landings in the indoor and outdoor areas of a building must be safe, sufficiently spacious and suitable for their purpose.
|
{'ID': '31_Finnish_SafetyOfUse'}
|
The landings in the indoor and outdoor <e1>areas</e1> of a <e2>building</e2> must be safe, sufficiently spacious and suitable for their purpose.
|
part-of
|
a477ee34-044e-443b-a95f-fbb1da913c38
|
Changing places toilets, facilities designed for individuals with complex and multiple impairments who may require the assistance of up to two assistants, should be provided in addition to any wheelchair-accessible accommodation in separate-sex toilet washrooms, wheelchair-accessible unisex toileting facilities and baby changing facilities.
|
{'ID': '160_UK_DocM_V2_AccessAndUseOfBuildings'}
|
<e1>Changing places toilets</e1>, facilities designed for individuals with complex and multiple impairments who may require the assistance of up to two assistants, should be provided in addition to any <e2>wheelchair-accessible</e2> accommodation in separate-sex toilet washrooms, wheelchair-accessible unisex toileting facilities and baby changing facilities.
|
none
|
db734798-9e42-4fe1-900c-77d4e6131809
|
The main doors for entering a dwelling (usually the front door) should have a door viewer unless other means exist to see callers, such as clear glass within the door or a window next to the doorset.
|
{'ID': '11_UK_DocQ_Security_Dwellings'}
|
The main doors for entering a dwelling (usually the front door) should have a door viewer unless <e1>other</e1> <e2>means</e2> exist to see callers, such as clear glass within the door or a window next to the doorset.
|
selection
|
10b2bf58-18df-46ee-a766-ed11eec6f42b
|
Humus soil, organic substances decomposing or rotting from moisture or building waste must not be left under new buildings, in their crawl spaces and in their gravel backfills functioning as a drainage layer.
|
{'ID': '45_Finnish_Health-Humidity'}
|
Humus soil, organic substances decomposing or rotting from moisture or <e1>building</e1> <e2>waste</e2> must not be left under new buildings, in their crawl spaces and in their gravel backfills functioning as a drainage layer.
|
part-of
|
06c2e0f7-69c8-47ec-bf31-9902ae9df7cf
|
Provision shall be made for any windows, skylights, or any transparent or translucent walls, ceilings or roofs to be safely accessible for cleaning.
|
{'ID': '109_UK_DocK_ProtectionFromFalling'}
|
Provision shall be made for any windows, skylights, or any transparent or translucent walls, <e1>ceilings</e1> or roofs to <e2>be safely accessible for cleaning</e2>.
|
necessity
|
7d7d55f1-b28d-4ce8-aec6-dd4dc0786ce8
|
For sizes of cylinder not listed, the heat loss from the cylinder should not exceed (16.66 8.33 V0.4)/(1000 24), where V is the volume in litres.
|
{'ID': '208_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
For sizes of cylinder not listed, the <e1>heat loss</e1> from the cylinder should not exceed <e2>(16.66 8.33 V0.4)/(1000 24)</e2>, where V is the volume in litres.
|
less-equal
|
54907849-c48f-4267-b5f0-fc7e9279da7c
|
For existing dwellings, when carrying out work on an existing system, such as installing or replacing components (e.g. replacing a boiler but retaining the pipework and heat emitters), the energy performance of the new components should be assessed.
|
{'ID': '409_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
For existing <e1>dwellings</e1>, when carrying out work on an existing system, such as installing or replacing components (e.g. replacing a boiler but retaining the pipework and heat emitters), the energy performance of the <e2>new</e2> components should be assessed.
|
none
|
f4b0b5b8-ab26-46a2-8028-c279958fa927
|
Any justification and strategy should be in line with the approved airtightness testing methodology, CIBSEs TM23.
|
{'ID': '355_UK_DocM_V2_AccessAndUseOfBuildings'}
|
Any justification and <e1>strategy</e1> should be <e2>in line with the approved airtightness testing methodology, CIBSEs TM23</e2>.
|
necessity
|
2c8d2bc3-cf23-48f8-b9c0-b90f150f9f93
|
Any walls, doors and windows should be insulated and draught-proofed to at least the same extent as in the existing building.
|
{'ID': '426_UK_DocM_V2_AccessAndUseOfBuildings'}
|
Any walls, <e1>doors</e1> and windows should be insulated and <e2>draught-proofed</e2> to at least the same extent as in the existing building.
|
necessity
|
aef92227-4c01-4c59-b96d-ce414540606b
|
Appliances capable of burning both biomass fuel and fossil fuel the CO2 emission factor and primary energy factor for dua-lfuel appliances should be used, except where the building is in a smoke control area, when the anthracite figure should be used.
|
{'ID': '63_UK_DocM_V2_AccessAndUseOfBuildings'}
|
Appliances capable of burning both biomass fuel and fossil fuel the CO2 emission factor and primary energy factor for dua-lfuel appliances should be used, except where the <e1>building</e1> is in a smoke control area, when the <e2>anthracite figure</e2> should be used.
|
necessity
|
9ebe07e9-8381-451a-9ab8-701912478b30
|
The air flow rate of all mechanical ventilation fans should be tested.
|
{'ID': '210_UK_DocF_V1_Ventilation'}
|
The air flow rate of all <e1>mechanical</e1> ventilation fans should be <e2>tested</e2>.
|
none
|
7f72632a-dc0a-4318-afd7-7090b42350fc
|
Mechanical supply terminals should be located and directed to avoid draughts.
|
{'ID': '106_UK_DocF_V1_Ventilation'}
|
Mechanical supply terminals should be <e1>located</e1> and directed to <e2>avoid draughts</e2>.
|
selection
|
a477ee34-044e-443b-a95f-fbb1da913c38
|
Changing places toilets, facilities designed for individuals with complex and multiple impairments who may require the assistance of up to two assistants, should be provided in addition to any wheelchair-accessible accommodation in separate-sex toilet washrooms, wheelchair-accessible unisex toileting facilities and baby changing facilities.
|
{'ID': '160_UK_DocM_V2_AccessAndUseOfBuildings'}
|
Changing places toilets, facilities designed for individuals with complex and multiple impairments who may require the assistance of up to two assistants, should be provided in addition to any wheelchair-accessible accommodation in <e1>separate-sex</e1> toilet <e2>washrooms</e2>, wheelchair-accessible unisex toileting facilities and baby changing facilities.
|
none
|
3f31e50a-cdcc-412c-a363-2bfdfb507770
|
For an electrically operated appliance, an integral remote or thermostatic control should be provided.
|
{'ID': '277_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
For an <e1>electrically operated appliance</e1>, an integral remote or t<e2>hermostatic control</e2> should be provided.
|
necessity
|
4e441774-859a-4a85-94ec-5fda3b2a6531
|
A copy should be submitted to the building control body as evidence that the system has been correctly installed, inspected and commissioned.
|
{'ID': '265_UK_DocF_V1_Ventilation'}
|
A <e1>copy</e1> should be <e2>submitted to the building control body as evidence that the system has been correctly installed, inspected and commissioned</e2>.
|
necessity
|
d728a9c8-0302-4bd1-b69b-0daeefce30d1
|
Where a service building has a reception or sales counter, there should be convenient access to it and part of it should be at a level suitable for a wheelchair user or a seated person.
|
{'ID': '84_UK_DocM_V2_AccessAndUseOfBuildings'}
|
Where a <e1>service building</e1> has a reception or sales counter, there should be <e2>convenient</e2> access to it and part of it should be at a level suitable for a wheelchair user or a seated person.
|
none
|
2f0f22aa-06d3-478d-a777-5aca5c2fb5c1
|
For sliding doors and gates, provide both of the following: (i) a stop or other effective means to prevent them coming off the end of the track; (ii) a retaining rail to prevent doors and gates falling if the suspension system fails or the rollers leave the track.
|
{'ID': '120_UK_DocK_ProtectionFromFalling'}
|
For sliding doors and gates, provide both of the following: (i) a stop or <e1>other effective</e1> <e2>means</e2> to prevent them coming off the end of the track; (ii) a retaining rail to prevent doors and gates falling if the suspension system fails or the rollers leave the track.
|
selection
|
45338082-ca66-418b-8fe1-8f2be926f330
|
A cube of no more than 100 millimetres may pass between the stair steps.
|
{'ID': '52_Finnish_SafetyOfUse'}
|
A cube of no more than <e1>100 millimetres</e1> may <e2>pass between the stair steps</e2>.
|
none
|
efe27c3d-80a8-4999-9310-77160105fe37
|
Instead, the building primary energy rate and building emission rate should be calculated as if the area covered by the pool were replaced with the equivalent area of floor with the same U-value as the pool surround.
|
{'ID': '91_UK_DocM_V2_AccessAndUseOfBuildings'}
|
Instead, the building primary energy rate and <e1>building emission rate</e1> should be <e2>calculated as if the area covered by the pool were replaced with the equivalent area of floor with the same U-value as the pool surround</e2>.
|
necessity
|
f2bf62e6-9577-48b5-b15d-9fe4904acf52
|
Where controls are integrated in the heater, the system should be provided with a time switch/programmer and room temperature sensor linked to heater firing and fan speed control.
|
{'ID': '268_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
Where controls are integrated in the heater, the system should be provided with a time switch/programmer and <e1>room temperature sensor</e1> <e2>linked to heater firing and fan speed control</e2>.
|
selection
|
6187cad8-0d6d-4154-b98b-7285b36fea8d
|
Continuously running fans should be set up to operate without occupant intervention but may have manual or automatic controls for selecting the high rate of operation.
|
{'ID': '65_UK_DocF_V1_Ventilation'}
|
<e1>Continuously running</e1> <e2>fans</e2> should be set up to operate without occupant intervention but may have manual or automatic controls for selecting the high rate of operation.
|
selection
|
6c789809-b1b8-429a-8fe2-8ce16f8a4b54
|
Air flows in the continuous working area of a parking garage for motor vehicles shall be designed so that the instantaneous carbon monoxide concentration does not exceed 7 mg/m3 (6 ppm).
|
{'ID': '62_Finnish_Health-IndoorClimateAndVentilation'}
|
Air flows in the continuous <e1>working area</e1> of a <e2>parking garage</e2> for motor vehicles shall be designed so that the instantaneous carbon monoxide concentration does not exceed 7 mg/m3 (6 ppm).
|
part-of
|
f0c72b35-5a0a-4554-8713-96f6f73a67f1
|
A cube with edges of no more than 50 millimetres may pass between the lower edge of a barriers protective part and the landing or the upper surface or edge of a step.
|
{'ID': '51_Finnish_SafetyOfUse'}
|
A cube with <e1>edges</e1> of no more than <e2>50 millimetres</e2> may pass between the lower edge of a barriers protective part and the landing or the upper surface or edge of a step.
|
less-equal
|
956efc87-87de-4d3c-99fb-dc58eab9353b
|
A dwelling that is intended for sheltered housing or supported housing of a person with mobility or functional impairment shall have at least one toilet and washing facility which has a free space with a diameter of at least 1,500 millimetres.
|
{'ID': '42_Finnish_Accessibility'}
|
A <e1>dwelling</e1> that is intended for sheltered housing or supported housing of a person with mobility or functional impairment shall have at least one toilet and washing facility which has a <e2>free space</e2> with a diameter of at least 1,500 millimetres.
|
none
|
60205cf2-fa87-4195-9415-a6fb144a9b72
|
Entrances and passageways to playgrounds and recreation areas used in the wintertime, as well as street areas surrounding the building and other public areas, must be protected from snow and ice falling from the roof of the building using snow barriers, taking into account the pitch of the roof.
|
{'ID': '96_Finnish_SafetyOfUse'}
|
<e1>Entrances</e1> and passageways to <e2>playgrounds</e2> and recreation areas used in the wintertime, as well as street areas surrounding the building and other public areas, must be protected from snow and ice falling from the roof of the building using snow barriers, taking into account the pitch of the roof.
|
part-of
|
5305da48-b810-4fd8-a0b3-7520f89ff401
|
When installing or renovating thermal elements, the element being installed should be draught-proofed, and air-leakage gaps should be filled.
|
{'ID': '194_UK_DocL_V1_ConsrvationOfFuelAndPower'}
|
When installing or renovating thermal elements, the element being installed should be draught-proofed, and <e1>air-leakage gaps</e1> should be <e2>filled</e2>.
|
necessity
|