Consider the scope on VIE in the functional location GIR/FPSOT/COF/FG /IPC-FG-_470-09-C511 the given unit name of PIPING GROUP FUEL GAS the corresponding item class discipline would be | Piping |
Consider the scope on 'PAZ - Buoy Hull GVI' in the functional location PAZ/BUOY /HSG/STRUC/HULL, the given unit name HULL FOR OFFLOADING BUOY, the corresponding item class discipline would be | FU Items |
Consider the scope on SCD + VIE in the functional location DAL/FPSOT/GAS/DEHYD/IPN-_NG-0655-10-C670 the given unit name of LINE GROUP,GAS DEHYD,GAS,SS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on Replace/Scrap in the functional location PAZ/FPSOH/COF/COOLW/HU-TSV-76107B the given unit name of S.W OUTLET THERMAL SAFETY VALVE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'Structure / Mooring / Ballast' in the functional location PAZ/FPSOT/HSG/STRUC, the given unit name Structure / Mooring / Ballast, the corresponding item class discipline would be | Structure |
Consider the scope on TA050/COR CP Measurement in the functional location GIR/FPSOH/HSG/STRUC/TA050 the given unit name of WATER BALLAST 3 STARBOARD (T) the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on 'Pre-pop test & Recalibration' in the functional location GIR/FPSOT/OIL/SEP /41-TSV3013A, the given unit name EC301A SOUPAPE THERMIQUE DE SECURITE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'VIE' in the functional location GIR/FPSOT/COF/COOLW/IF902A, the given unit name SEAWATER FILTER COOLING NETWORK (V), the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on 'Visual inspection of tertiary structure' in the functional location PAZ/FPSOT/HSG/STRUC/R6, the given unit name R6 Structural Module, the corresponding item class discipline would be | Structure |
Consider the scope on 'COR - WB6P - CP Measurement' in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8611F, the given unit name PORT WING BALLAST 6P, the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on VII in the functional location PAZ/FPSOT/WAT/WATLF/TO-TZ-5013B the given unit name of MAIN PUMP OIL TANK B the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on VII in the functional location PAZ/SUB /EXT/EWELL/RP40L_HU-TZ-8800A the given unit name of IBP WATER TANK the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on 'COR - APT_P_CP Measurement' in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8631A2, the given unit name of PORT WING BALLAST BUFFER TANK A2, the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on 'VIE' in the functional location CLV/FPSOT/ELE/PWG /TO-EP-6010D1B, the given unit name of MINERAL OIL STAND BY COOLER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on BV tasks & intrusive major inspection in the functional location PAZ/FPSOH/OIL/OWAT /HU-T_-2711B the given unit name of MAIN PROD WATER ATM. DECAN. TANK 2711B the corresponding item class discipline would be | FU Items |
Consider the scope on 'VIE' in the functional location PAZ/FPSOT/COF/LIFT /HU-TZ-7801B, the given unit name HYDRAULIC OIL TANK, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on 'VIE' in the functional location GIR/FPSOT/COF/CHEM /IPN-XM-_475-24-B580, the given unit name PIPING GROUP CHEMICAL INJECTION, the corresponding item class discipline would be | Piping |
Consider the scope on GIR/HULL_POTENTIAL MEASUREMENT in the functional location GIR/FPSOH/HSG/STRUC/HULL the given unit name of GIRASSOL FPSO-HULL the corresponding item class discipline would be | FU Items |
Consider the scope on VII in the functional location PAZ/FPSOT/ELE/PWG /TO-TZ-6036C the given unit name of SEPARATOR WASTE LIQUID TANK the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on VII in the functional location DAL/FPSOT/COF/INWAT/6-DA-4111A2 the given unit name of SAND ACCUMULATOR DRUM the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on DAL/FPSOT/GAS/DEHYD/6-PRV-55540 in the functional location DAL/FPSOT/GAS/DEHYD/6-PRV-55540 the given unit name of PRES. SAF. VALVE, ON TEG STORAGE TANK the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on BUOY MOORING HAWSER PS/WEAR in the functional location PAZ/BUOY /OIL/LOAD /MOORING HAWSER PS the given unit name of BUOY MOORING HAWSER PORT SIDE the corresponding item class discipline would be | FU Items |
Consider the scope on 'Overhaul' in the functional location CLV/FPSOT/EXT/TRANS/TO-PSV-23504B, the given unit name of CRUDE OIL MANI OUTLET PRESS SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'UTC + VIE' in the functional location PAZ/FPSOT/OIL/STAB /IPC-_HL-TO21-03-D03, the given unit name Hydrocarbon liquid piping group, the corresponding item class discipline would be | Piping |
Consider the scope on SCD + VIE in the functional location CLV/FPSOT/GAS/FLARE/IPN-_VE-TO36-03-_50 the given unit name of Vent piping group the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location PAZ/FPSOT/OIL/SEP /IPN-_PW-TO20-01-D03 the given unit name of Produced water piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location GIR/FPSOT/GAS/FLARE/41-DS-SDV2011, the given unit name DS201 CAPACITE AIR, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on GIR-Visual Inspection and Function Test in the functional location GIR/FPSOT/COF/LIFT the given unit name of LIFTING the corresponding item class discipline would be | Lifting |
Consider the scope on Replace/Scrap in the functional location PAZ/FPSOT/ELE/PWG /TO-TSV-602584D the given unit name of WATER SIDE PSV the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/GAS/DEHYD/IPN-_DF-0655-07-F513, the given unit name LINE GROUP,GAS DEHYD,DRAIN,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on PSD Replacement in the functional location CLV/BUOY /CRS/AIR /OB-PRV-07207 the given unit name of HYDRAULIC OIL SUPPLY PRESS. SAFE. VALVE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'CVI' in the functional location CLV/FPSOT/ELE/PWG /TO-FA-6010B1, the given unit name of GAS TURBINE ENCLOSURE FLAME ARRESTOR B1, the corresponding item class discipline would be | Flame Arrestor |
Consider the scope on 'P2-C_Visual inspection of tertiary struc' in the functional location GIR/FPSOT/HSG/STRUC/MOD P2-C, the given unit name STRUCTURAL MODULE P2-C Fr 64-66, the corresponding item class discipline would be | Structure |
Consider the scope on 'VIE' in the functional location GIR/FPSOT/WAT/WINJ /IPN-AV-_454-14-B630, the given unit name PIPING GROUP WATER INJECTION, the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location PAZ/FPSOA/CRS/EPWG /LQ-T_-0501 the given unit name of EMDG DAILY FUEL TANK the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on 'Replace/Scrap' in the functional location CLV/FPSOT/COF/CHEM /TO-PSV-75562B, the given unit name of LDHI PUMP B OUTLET PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Visual inspection of complete structure in the functional location PAZ/FPSOT/HSG/STRUC/S1 the given unit name of S1 Structural Module the corresponding item class discipline would be | Structure |
Consider the scope on Overhaul in the functional location PAZ/FPSOT/OIL/SEP /TO-PSV5-20145A the given unit name of TO V-2011A PRESSURE SAFETY VALVE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'GIR/41-PSV7775B_INSPECTION' in the functional location GIR/FPSOT/WAT/WINJ /41-PSV7775B, the given unit name SOUPAPE DE SECURITE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on VIE in the functional location CLV/FPSOT/CRS/AIR /TO-VZ-0720A2 the given unit name of DESICCANT VESSEL 2 the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0651-01-B670, the given unit name LINE GROUP,LP GAS,GAS,SS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on TANKER CHAFFING CHAIN PS/WEAR MEASUR in the functional location PAZ/BUOY /OIL/LOAD /PS MOORING TANKER the given unit name of PS MOORING TANKER SIDE the corresponding item class discipline would be | FU Items |
Consider the scope on 'Overhaul' in the functional location PAZ/FPSOT/OIL/SEP /TO-PSV2-20145A, the given unit name TO V-2011A PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on UTC + VIE in the functional location PAZ/FPSOT/OIL/OWAT /IPN-_HG-TO27-06-B03 the given unit name of Hydrocarbon gas piping group the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location DAL/FPSOT/GAS/COMP /IPN-_NG-0652-15-D511 the given unit name of LINE GROUP,HP GAS,GAS,CS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location PAZ/FPSOT/OIL/STAB /TO-ES-2111B1 the given unit name of CRUDE-CRUDE HEATER B1 the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on VIE in the functional location DAL/FPSOT/EXT/MSEP /IPN-_NH-0635-01-C513 the given unit name of LINE GROUP,OIL TEST,OIL,CS,IPN the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location PAZ/FPSOT/GAS/COMP /TO-VF-316602 the given unit name of GAS FILTER UNIT 02 the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on HU-TR-8631F2 FU/TEPA GVI Intermed. insp. in the functional location CLV/FPSOH/HSG/STRUC/HU-TR-8631F2 the given unit name of PORT WING BALLAST BUFFER TANK F2 the corresponding item class discipline would be | FU Items |
Consider the scope on 'GVI' in the functional location DAL/BUOY /HSG/STRUC/COMP 06, the given unit name BUOY TANK COMPARTMENT, the corresponding item class discipline would be | FU Items |
Consider the scope on 'Visual inspection of tertiary structure' in the functional location PAZ/FPSOT/HSG/STRUC/S2, the given unit name S2 Structural Module, the corresponding item class discipline would be | Structure |
Consider the scope on CLASS PSV-Overhaul in the functional location PAZ/FPSOH/OIL/OWAT /HU-PVSV-27037B the given unit name of TANK PRESSURE VACUUM SAFETY VALVE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on VIE in the functional location GIR/FPSOT/COF/FG /IPN-FG-_470-06-C511 the given unit name of PIPING GROUP FUEL GAS the corresponding item class discipline would be | Piping |
Consider the scope on 'Pre-pop test & Recalibration' in the functional location DAL/FPSOT/COF/CHEM /6-PSV-36002A, the given unit name PRESSURE SAFETY VALVE, ON ANTI FOAM TANK, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on VIE in the functional location PAZ/FPSOH/COF/COOLW/IPN-_SW-HU76-02-_90 the given unit name of Sea water piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location DAL/FPSOH/COF/FO /IP_GVI_UW_LINES, the given unit name UW GROUP OF LINES FOR GVI, the corresponding item class discipline would be | Piping |
Consider the scope on GVI in the functional location CLV/FPSOH/HSG/STRUC/HELID-DECK-PRM_STR the given unit name of Primary structure of HELIDECK module the corresponding item class discipline would be | Structure |
Consider the scope on 'CLV/BUOY COMPART_INTRUSIVE' in the functional location CLV/BUOY /HSG/STRUC/COMP B1, the given unit name of BUOY COMPARTMENT, the corresponding item class discipline would be | FU Items |
Consider the scope on UTC + VIE in the functional location PAZ/FPSOH/CRS/AIR /IPN-_AS-HU07-01-_03 the given unit name of Sounding piping group the corresponding item class discipline would be | Piping |
Consider the scope on FI Visual Inspection of complete struct. in the functional location CLV/FPSOT/HSG/STRUC/M113 the given unit name of M113 STR Module WELL FLUIDS RECEPTION the corresponding item class discipline would be | Structure |
Consider the scope on VIE + NDT in the functional location CLV/FPSOT/COF/CHEM /IPN-_SC-TO75-01-_49 the given unit name of Cleaning solvent piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'VII' in the functional location GIR/FPSOT/ELE/PWG /E301-A1, the given unit name UB990A-AIR COOLER BUNDLE 1, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on 'CLV/HUTH092603 - Major External Inspecti' in the functional location CLV/FPSOT/CRS/HVAC /HU-TH-092603, the given unit name of HV01 CHILLED WATER DOSING TANK, the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on 'VII' in the functional location PAZ/FPSOT/OIL/LOAD /TO-V_-2501, the given unit name CRUDE OIL OFFLOADING TANDEM, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on VIE + NDT in the functional location CLV/FPSOT/OIL/OWAT /IPN-_PW-TO27-13-D03 the given unit name of Produced water (Oily water) piping group the corresponding item class discipline would be | Piping |
Consider the scope on Complet. Topside P33 Structure Insp. in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P33 the given unit name of P33 Structural Module the corresponding item class discipline would be | Structure |
Consider the scope on 'P2-A_Visual inspection of complet struct' in the functional location GIR/FPSOT/HSG/STRUC/MOD P2-A, the given unit name STRUCTURAL MODULE P2-A Fr 56-60, the corresponding item class discipline would be | Structure |
Consider the scope on Pre-Pop test, overhaul & recalibration in the functional location CLV/FPSOT/OIL/OWAT /TO-PSV-27106C the given unit name of P.W. BOOSTER PUMP C PRESSURE SAFETY VLV the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on PAZ/TO-PSVB-9163-Scrap/Replace in the functional location PAZ/FPSOT/EXT/EWELL/TO-PSVB-9163 the given unit name of LP SUPPLY SAFETY VALVE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on PSD Replacement in the functional location CLV/FPSOH/CRS/AIR /HU-PSV1-0766E the given unit name of TANK CO_1P VALVE CONTROL PANEL E PSV the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'VII' in the functional location DAL/FPSOT/EXT/EWELL/6-DG-3000L, the given unit name TRANSPORTABLE RISER PIG TRAP, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on VII in the functional location CLV/FPSOT/CRS/AIR /TO-VA-0720B the given unit name of INSTRUMENT AIR RECEIVER B the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on 'VII' in the functional location DAL/FPSOT/CRS/AIR /6-DA-1150, the given unit name DRY AIR RECEIVER, the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on Major Non Intrusive Insp TA860D in the functional location GIR/FPSOT/COF/CHEM /TA860D the given unit name of BIOCIDE SUBSEA TANK (T) the corresponding item class discipline would be | Non Structural Tank |
Consider the scope on Complet. Topside P63 Structure Insp. in the functional location DAL/FPSOT/HSG/STRUC/TOPSIDE-P63 the given unit name of P63 Structural Module the corresponding item class discipline would be | Structure |
Consider the scope on Overhaul in the functional location CLV/FPSOT/OIL/SEP /TO-PSV-20208E the given unit name of 2ND STG SEP. PRESSURE SAFETY VALVE E the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on Overhaul in the functional location CLV/FPSOT/COF/CHEM /TO-PSV-75305B the given unit name of UTILITY MEOH PUMP BKFLOW PRS SAF. VLV B the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on INSPECTION-BEARING-A9, Module P51 in the functional location DAL/FPSOT/HSG/STRUC the given unit name of Structures / Mooring / Ballast the corresponding item class discipline would be | Structure |
Consider the scope on Overhaul in the functional location PAZ/FPSOT/COF/COOLW/TO-PSV2-76002 the given unit name of OUTLET TO LP FLARE PRESSURE SAFETY VALVE the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'UTC + VIE' in the functional location GIR/FPSOT/OIL/SEP /IPN-GH-_420-12-B511, the given unit name PIPING GROUP OIL SEPARATION, the corresponding item class discipline would be | Piping |
Consider the scope on VIE in the functional location GIR/FPSOT/WAT/ELCL /DA901 the given unit name of UB901-HYPOCHLORITE STORAGE (T) the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on VIE in the functional location GIR/FPSOT/WAT/WINJ /IF702H the given unit name of AERATED SEA WATER FILTER H 5 çm (V) the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on 'BV tasks & intrusive major inspection' in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8632A, the given unit name VOID 2 STARBOARD, the corresponding item class discipline would be | FU Items |
Consider the scope on 'SCD + VIE' in the functional location CLV/FPSOT/EXT/MSEP /IPN-_HG-TO11-02-D49, the given unit name of Hydrocarbon gas piping group, the corresponding item class discipline would be | Piping |
Consider the scope on UTC + VIE in the functional location PAZ/FPSOT/OIL/OWAT /IPN-_HG-TO27-04-B03 the given unit name of Hydrocarbon gas piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/GAS/FLARE/IPN-_FS-0621-45-B513, the given unit name LINE GROUP,FLARE,FLARES,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/COF/CHEM /IPN-_AM-0619-30-B670, the given unit name LINE GROUP,METHANOL,METHANOL,SS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on Major Intrus.insp_TO-FA-9301.ARRAST in the functional location GIR/FPSOT/COF/FO /TO-FA-9301 the given unit name of FLAME ARRESTOR, ON VENT 3-AV-4-9301-B511 the corresponding item class discipline would be | Flame Arrestor |
Consider the scope on 'GIR/41-PSV-0230-Révision B.V' in the functional location GIR/FPSOT/OIL/OWAT /41-PSV0230, the given unit name TA023 SOUPAPE DE SECURITE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on 'VIE' in the functional location DAL/FPSOT/CRS/AIR /6-IF-1151B1, the given unit name SERVICE AIR FILTER, the corresponding item class discipline would be | Pressure Vessel (VIE) |
Consider the scope on 'GVI' in the functional location DAL/FPSOT/ELE/PWG /6-LH-1252A, the given unit name FLAME ARRESTOR, RUN DOWN TANK, the corresponding item class discipline would be | Flame Arrestor |
Consider the scope on VII in the functional location DAL/FPSOT/GAS/COMP /6-EC-5410 the given unit name of DISCHARGE COOLER, INJECTION GAS COMPRES. the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on 'COR - WBC2S - CP Measurement' in the functional location PAZ/FPSOH/HSG/STRUC/HU-T_-8610B, the given unit name STARBOARD CENTRAL BALLAST 2S, the corresponding item class discipline would be | Corrosion Monitoring |
Consider the scope on VII in the functional location CLV/FPSOT/GAS/COMP /TO-VZ-3130B-3 the given unit name of SEAL GAS SCRUBBER the corresponding item class discipline would be | Pressure Vessel (VII) |
Consider the scope on 'PIPERACK7 Visual Insp of tertiary struct' in the functional location GIR/FPSOT/HSG/STRUC/MOD PIPERACK 7, the given unit name STRUCTURAL MODULE PIPERACK 7 fr 65, the corresponding item class discipline would be | Structure |
Consider the scope on 'MOD/COMPUB512 Visual insp of complet str' in the functional location GIR/FPSOT/HSG/STRUC/MOD GAS COMP UB512, the given unit name STRUCTURAL MODULE GAS COMP fr 71-78, the corresponding item class discipline would be | Structure |
Consider the scope on 'UTC + VIE' in the functional location DAL/FPSOT/OIL/SEP /IPN-_NW-0631-15-C513, the given unit name LINE GROUP,OIL 1ST,WATER,CS,IPN, the corresponding item class discipline would be | Piping |
Consider the scope on UTC + VIE in the functional location PAZ/FPSOT/OIL/STAB /IPN-_HG-TO21-04-B03 the given unit name of Hydrocarbon gas piping group the corresponding item class discipline would be | Piping |
Consider the scope on 'Overhaul' in the functional location CLV/FPSOT/COF/CHEM /TO-PSV-75407C, the given unit name of TO-P_-7540C OUTLET PRESSURE SAFETY VALVE, the corresponding item class discipline would be | Pressure Safety Device |
Consider the scope on VIE in the functional location GIR/FPSOT/GAS/FLARE/IPN-FS-_436-05-B661 the given unit name of PIPING GROUP GAS FLARE the corresponding item class discipline would be | Piping |