docName
stringlengths
19
23
nameWell
stringclasses
23 values
nameWellbore
stringclasses
26 values
name
stringclasses
1 value
dTimStart
stringlengths
25
25
dTimEnd
stringlengths
25
25
versionKind
stringclasses
1 value
createDate
stringclasses
183 values
wellAlias
dict
wellboreAlias
listlengths
2
2
wellboreInfo
listlengths
1
1
statusInfo
listlengths
1
1
fluid
listlengths
0
6
porePressure
listlengths
0
6
surveyStation
listlengths
0
46
activity
listlengths
0
49
lithShowInfo
listlengths
0
7
15_9_F_11_B_2013_06_21
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-20T00:00:00+02:00
2013-06-21T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-21T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-16T13:30:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Set and pressure test Safelock plug at 635m MD.\nRetrieve wearbushing.\nInstall lockdown sub.\n", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "24", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Pulled out of hole with cleanout assembly from 4150m MD to 2796m MD.\nStopped due to damaged junction box on aft PRS.\nPulled out of hole with cleanout assembly from 2796m MD to 1512m MD.", "tightWell": "0", "tvd": "3258", "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-20T22:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-20T21:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "13.5" } ]
[]
[]
[ { "comments": "Continued displacing well through bit to 1.03 sg brine with 1000-2000 lpm and 118-235 bar.", "dTimEnd": "2013-06-20T00:30:00+02:00", "dTimStart": "2013-06-20T00:00:00+02:00", "md": "4687", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened MFCTC tool by setting down 20 bar on PBR.", "dTimEnd": "2013-06-20T00:45:00+02:00", "dTimStart": "2013-06-20T00:30:00+02:00", "md": "4687", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Displaced well through MFCTC to 1.03 sg bine with 2000-4000 lpm, 40-146 bar, 90 rpm and 9-18 kNm.", "dTimEnd": "2013-06-20T02:15:00+02:00", "dTimStart": "2013-06-20T00:45:00+02:00", "md": "4687", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Operated the MFCTC to closed position. Deactivated well commissioner packer.", "dTimEnd": "2013-06-20T02:45:00+02:00", "dTimStart": "2013-06-20T02:15:00+02:00", "md": "4687", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Flushed flowlines with 1,03 sg brine.", "dTimEnd": "2013-06-20T03:15:00+02:00", "dTimStart": "2013-06-20T02:45:00+02:00", "md": "4687", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Prepared to perform pressure test on well down pipe and kill line. Performed line test.\nPressure tested well to 345 bar with 1.03 sg brine - ok.", "dTimEnd": "2013-06-20T04:15:00+02:00", "dTimStart": "2013-06-20T03:15:00+02:00", "md": "4687", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed flow check for 30 minutes - well static.", "dTimEnd": "2013-06-20T04:45:00+02:00", "dTimStart": "2013-06-20T04:15:00+02:00", "md": "4687", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with cleanout string on 5 1/2\" drill pipe from 4687m MD to 4120m MD.", "dTimEnd": "2013-06-20T07:15:00+02:00", "dTimStart": "2013-06-20T04:45:00+02:00", "md": "4120", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke out and laid down 10 3/4\" scraper.", "dTimEnd": "2013-06-20T07:45:00+02:00", "dTimStart": "2013-06-20T07:15:00+02:00", "md": "4120", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with cleanout string on 5 1/2\" drill pipe from 4120m MD to 2796m MD.", "dTimEnd": "2013-06-20T10:00:00+02:00", "dTimStart": "2013-06-20T07:45:00+02:00", "md": "2796", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Top drive collided with stand in the pipe racking machine and bent top joint. Performed timeout for safety and inspected for damages. Aft PRS junction box damaged. Secured stand with fore PRS and parked aft PRS. Laid out stand to cantilever. Performed PDO check of derrick.", "dTimEnd": "2013-06-20T19:30:00+02:00", "dTimStart": "2013-06-20T10:00:00+02:00", "md": "2796", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Pulled out of hole with cleanout string on 5 1/2\" drill pipe from 2796m MD to 1667m MD.", "dTimEnd": "2013-06-20T22:00:00+02:00", "dTimStart": "2013-06-20T19:30:00+02:00", "md": "1667", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke out and laid down well commissioner and 9 5/8\" scraper.", "dTimEnd": "2013-06-20T23:00:00+02:00", "dTimStart": "2013-06-20T22:00:00+02:00", "md": "1667", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed to 3 1/2\" handling equipment.", "dTimEnd": "2013-06-20T23:30:00+02:00", "dTimStart": "2013-06-20T23:00:00+02:00", "md": "1667", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with cleanout string on 3 1/2\" drill pipe from 1667m MD to 1512m MD.", "dTimEnd": "2013-06-21T00:00:00+02:00", "dTimStart": "2013-06-20T23:30:00+02:00", "md": "1512", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_22
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-21T00:00:00+02:00
2013-06-22T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-22T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-21T21:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Make up claxton tool to riser.\nRig down cylinders and tension ring.\nPull high pressure drilling riser and lay out.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "25", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Pulled out of hole with cleanout string from 1512m MD.\nDisplaced riser to seawater.\nInstalled Safelock plug at 635m MD, and pressure tested same to 200 bar (from below) and 345 bar (from above).\nRetrieved 10 3/4\" wearbushing.\nInstalled lock down assembly.\nNippled down diverter and BOP.", "tightWell": "0", "tvd": "3258", "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-21T21:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-21T15:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "13.5" } ]
[]
[]
[ { "comments": "Pulled out of hole with cleanout string on 3 1/2\" drill pipe from 1512m MD to 165m MD.", "dTimEnd": "2013-06-21T03:30:00+02:00", "dTimStart": "2013-06-21T00:00:00+02:00", "md": "165", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Displaced surface lines and manifolds to seawater.", "dTimEnd": "2013-06-21T04:30:00+02:00", "dTimStart": "2013-06-21T03:30:00+02:00", "md": "165", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Displaced riser to seawater from 165m MD with 2600 lpm and 59 bar.", "dTimEnd": "2013-06-21T05:30:00+02:00", "dTimStart": "2013-06-21T04:30:00+02:00", "md": "165", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with cleanout string on 3 1/2\" drill pipe from 156m MD. Laid down well protector to cantilever.", "dTimEnd": "2013-06-21T06:30:00+02:00", "dTimStart": "2013-06-21T05:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed to 5 1/2\" handling equipment. Cleaned and tidied rig floor.", "dTimEnd": "2013-06-21T07:00:00+02:00", "dTimStart": "2013-06-21T06:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to pick up and run Safelock plug.", "dTimEnd": "2013-06-21T07:15:00+02:00", "dTimStart": "2013-06-21T07:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and made up Safelock plug. Ran in hole with Safelock plug to 632m MD.", "dTimEnd": "2013-06-21T09:15:00+02:00", "dTimStart": "2013-06-21T07:15:00+02:00", "md": "632", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Established circulation and washed the setting area with 1100 lpm and 4 bar. Installed Safelock plug at 635m MD. Top of plug at 631.6m MD.", "dTimEnd": "2013-06-21T10:30:00+02:00", "dTimStart": "2013-06-21T09:15:00+02:00", "md": "632", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up from cement unit and pressure tested Safelock plug from below to 200 bar for 10 minutes - ok. Pumped a total of 1128 liters, bled 1120 liters back.", "dTimEnd": "2013-06-21T11:00:00+02:00", "dTimStart": "2013-06-21T10:30:00+02:00", "md": "632", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed ball valve and released Safelock running tool.", "dTimEnd": "2013-06-21T11:30:00+02:00", "dTimStart": "2013-06-21T11:00:00+02:00", "md": "632", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Spotted 5m3 hi-visc pill on top of Safelock plug with 1800 lpm and 11 bar.", "dTimEnd": "2013-06-21T12:00:00+02:00", "dTimStart": "2013-06-21T11:30:00+02:00", "md": "632", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with Safelock running tool and laid out same to cantilever.", "dTimEnd": "2013-06-21T13:00:00+02:00", "dTimStart": "2013-06-21T12:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up from cement unit and closed shear ram. Pressure tested Safelock plug from above to 345 bar for 10 minutes - ok. Pumped a total of 779 liters, bled 767 liters back. Opened shear ram.", "dTimEnd": "2013-06-21T13:30:00+02:00", "dTimStart": "2013-06-21T13:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and made up bullnose and wearbushing retrieval tool.", "dTimEnd": "2013-06-21T14:00:00+02:00", "dTimStart": "2013-06-21T13:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran in hole with wearbushing retrieval tool to 146m MD. Pulled wearbushing free with 46MT overpull.", "dTimEnd": "2013-06-21T14:30:00+02:00", "dTimStart": "2013-06-21T14:00:00+02:00", "md": "146", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Racked back one stand and jetted wellhead with 1.03 sg brine at 2000 lpm and 20 bar.", "dTimEnd": "2013-06-21T15:00:00+02:00", "dTimStart": "2013-06-21T14:30:00+02:00", "md": "138", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with 10 3/4\" wearbushing on 5 1/2\" drill pipe. Laid out wearbushing to cantilever.", "dTimEnd": "2013-06-21T17:00:00+02:00", "dTimStart": "2013-06-21T15:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to picking up lockdown assembly.", "dTimEnd": "2013-06-21T17:15:00+02:00", "dTimStart": "2013-06-21T17:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and made up seal assembly lockdown assembly and ran in hole on 5 1/2\" drill pipe to wellhead at 138m MD.", "dTimEnd": "2013-06-21T18:00:00+02:00", "dTimStart": "2013-06-21T17:15:00+02:00", "md": "146", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up to perform pressure test from cement unit. Pressure set seal assembly lockdown assembly with 207 bar. Verified assembly set by applying 30MT overpull.", "dTimEnd": "2013-06-21T20:30:00+02:00", "dTimStart": "2013-06-21T18:00:00+02:00", "md": "146", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole from 138m MD. Cleaned and tidied rig floor.", "dTimEnd": "2013-06-21T21:00:00+02:00", "dTimStart": "2013-06-21T20:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to start nippling down diverter and bell nipple.", "dTimEnd": "2013-06-21T21:15:00+02:00", "dTimStart": "2013-06-21T21:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up to pull diverter. Pulled diverter. Installed master bushings. Laid diverter out to cantilever. Prepared to pull bell nipple.", "dTimEnd": "2013-06-22T00:00:00+02:00", "dTimStart": "2013-06-21T21:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_23
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-22T00:00:00+02:00
2013-06-23T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-23T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-21T21:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Pull high pressure drilling riser.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "26", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Nippled down diverter and BOP.\nInstalled claxton tool to NT-2 connector.\nRigged down tensioning cylinders and tension ring.\nInstalled guide wires.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-22T21:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-22T15:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Nippled down BOP and moved over to test stump.", "dTimEnd": "2013-06-22T11:30:00+02:00", "dTimStart": "2013-06-22T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to remove master bushings and pick up and make up claxton tool to NT-2 connector.", "dTimEnd": "2013-06-22T11:45:00+02:00", "dTimStart": "2013-06-22T11:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed master bushings and outer bushings. Picked up and made up claxton tool to 5 1/2\" drill pipe.", "dTimEnd": "2013-06-22T12:30:00+02:00", "dTimStart": "2013-06-22T11:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Landed off claxton tool to NT-2 connector. Attached control lines and latched running tool. Recovered control lines. Verified make up by applying 5MT overpull.", "dTimEnd": "2013-06-22T13:15:00+02:00", "dTimStart": "2013-06-22T12:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed scaffold from around claxton tool.\n\nMeanwhile: Cleaned and tidied rig floor.", "dTimEnd": "2013-06-22T14:00:00+02:00", "dTimStart": "2013-06-22T13:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held prejob meeting prior to rigging down tensioning system.", "dTimEnd": "2013-06-22T14:15:00+02:00", "dTimStart": "2013-06-22T14:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged down tensioning cylinders and tension ring.\n\nMeanwhile: Prepared 24\" elevator, C-plate and bails on rig floor.", "dTimEnd": "2013-06-22T21:00:00+02:00", "dTimStart": "2013-06-22T14:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed split hatch cover from F-11. Rigged up to run guide wires to wellhead template.", "dTimEnd": "2013-06-22T23:00:00+02:00", "dTimStart": "2013-06-22T21:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran guide wires to seabed.", "dTimEnd": "2013-06-23T00:00:00+02:00", "dTimStart": "2013-06-22T23:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_24
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-23T00:00:00+02:00
2013-06-24T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-24T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-21T21:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run and land production riser.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "27", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Ran guide wires and attached same in wellhead template.\nDisconnected riser connector.\nPulled out of hole with high pressure drilling riser.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-23T18:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-23T13:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Ran guide wires to seabed and latched in place to wellhead template using ROV. Ran hot stab hydraulic connection and connected same to hot stab receptacle on riser connector using ROV.", "dTimEnd": "2013-06-23T03:30:00+02:00", "dTimStart": "2013-06-23T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to disconnect high pressure drilling riser.", "dTimEnd": "2013-06-23T03:45:00+02:00", "dTimStart": "2013-06-23T03:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Released high pressure drilling riser and pulled to 1 meter above wellhead housing. ROV locked hydraulic valves on high pressure drilling riser.", "dTimEnd": "2013-06-23T04:30:00+02:00", "dTimStart": "2013-06-23T03:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up to pull high pressure drilling riser. Installed spider into rotary and installed hydraulic hoses. Function tested same.", "dTimEnd": "2013-06-23T08:30:00+02:00", "dTimStart": "2013-06-23T04:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with BOP joint. Laid out BOP joint and claxton tool to cantilever.", "dTimEnd": "2013-06-23T10:30:00+02:00", "dTimStart": "2013-06-23T08:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed to 24\" handling equipment.", "dTimEnd": "2013-06-23T10:45:00+02:00", "dTimStart": "2013-06-23T10:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled riser tension joint and laid out same to cantilever.", "dTimEnd": "2013-06-23T12:30:00+02:00", "dTimStart": "2013-06-23T10:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed handling equipment to 5 1/2\".", "dTimEnd": "2013-06-23T12:45:00+02:00", "dTimStart": "2013-06-23T12:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled riser pup and one double (#2 + #3) joint. Laid out same to cantilever.", "dTimEnd": "2013-06-23T15:15:00+02:00", "dTimStart": "2013-06-23T12:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Unable to lay double riser joint on subrack craddle. Cut bumber bar off portside. Moved double riser joint to portside.", "dTimEnd": "2013-06-23T17:45:00+02:00", "dTimStart": "2013-06-23T15:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pull double riser joint (#4 + #5) and laid out to cantilever.", "dTimEnd": "2013-06-23T19:00:00+02:00", "dTimStart": "2013-06-23T17:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting with new crew.", "dTimEnd": "2013-06-23T19:15:00+02:00", "dTimStart": "2013-06-23T19:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected flange on single joint (#6). Installed lifting nubbing and laid out to cantilever with crane.", "dTimEnd": "2013-06-23T21:30:00+02:00", "dTimStart": "2013-06-23T19:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up single riser joint (#7) and set in spider.", "dTimEnd": "2013-06-23T22:00:00+02:00", "dTimStart": "2013-06-23T21:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected guide wires with ROV. Retrieved guide wires.", "dTimEnd": "2013-06-23T23:00:00+02:00", "dTimStart": "2013-06-23T22:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected flange on riser joint #7.", "dTimEnd": "2013-06-24T00:00:00+02:00", "dTimStart": "2013-06-23T23:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_25
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-24T00:00:00+02:00
2013-06-25T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-25T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-21T21:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run production riser.\nLand and lock the tieback connector.\nInstall centralizers, boat collision tool, tensioner ring assembly and tension sylinders.\n", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "28", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Pulled high pressure drilling riser and laid out to cantilever.\nRan production riser.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-24T18:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-24T15:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Installed lifting nubbing on riser joint #7 and laid out to cantilever with crane.", "dTimEnd": "2013-06-24T01:30:00+02:00", "dTimStart": "2013-06-24T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up lower riser pup #8 and set in spider. Disconnected flange. Installed lifting nubbing and laid out to cantilever with crane.", "dTimEnd": "2013-06-24T04:00:00+02:00", "dTimStart": "2013-06-24T01:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and laid out stressjoint and TBC (#9) to cantilever.\n\nMeanwhile: Installed guide funnel on wellhead.", "dTimEnd": "2013-06-24T05:30:00+02:00", "dTimStart": "2013-06-24T04:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed production tension contact ring on F-11 slot. Lowered annulus valves through rotary to wellhead.", "dTimEnd": "2013-06-24T06:00:00+02:00", "dTimStart": "2013-06-24T05:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up to run production riser.", "dTimEnd": "2013-06-24T08:30:00+02:00", "dTimStart": "2013-06-24T06:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to start run production riser.", "dTimEnd": "2013-06-24T08:45:00+02:00", "dTimStart": "2013-06-24T08:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up tieback connector and stessjoint and set in rotary. Picked up and made up lower riser pup.", "dTimEnd": "2013-06-24T12:15:00+02:00", "dTimStart": "2013-06-24T08:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lowered production riser through rotary to test connector. Functioned tieback connector by fully stroking out. Full stroke too long, broke ROV panel.", "dTimEnd": "2013-06-24T12:45:00+02:00", "dTimStart": "2013-06-24T12:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out with tiaback connector and riser stressjoint and set in rotary. Disconnected lower riser pup and laid out to cantilever. Laid out primary riser stressjoint to cantilever.", "dTimEnd": "2013-06-24T15:15:00+02:00", "dTimStart": "2013-06-24T12:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Picked up backup riser stressjoint to rotary and made up to lower riser pup.", "dTimEnd": "2013-06-24T18:00:00+02:00", "dTimStart": "2013-06-24T15:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Tested backup tieback connector.", "dTimEnd": "2013-06-24T19:00:00+02:00", "dTimStart": "2013-06-24T18:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting with new crew.", "dTimEnd": "2013-06-24T19:15:00+02:00", "dTimStart": "2013-06-24T19:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Shimmed TBC ring. Lowered riser and landed off in riser spider.", "dTimEnd": "2013-06-24T19:45:00+02:00", "dTimStart": "2013-06-24T19:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up riser single #1 and positioned and landed off joint. Inspected seal surface and installed IX-14 ring. Made up flange connection with bolt tensioner. Pressure tested flange connection to 3000 psi through test port - ok.", "dTimEnd": "2013-06-24T22:45:00+02:00", "dTimStart": "2013-06-24T19:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and installed flange protection fairings.", "dTimEnd": "2013-06-24T23:00:00+02:00", "dTimStart": "2013-06-24T22:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lowered riser and set in riser spider. Attached guide wires to clamp.", "dTimEnd": "2013-06-24T23:45:00+02:00", "dTimStart": "2013-06-24T23:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran guide wires to seabed and attached to wellhead template wiht ROV.\n\nMeanwhle: Installed lifting nubbing to riser single #2.", "dTimEnd": "2013-06-25T00:00:00+02:00", "dTimStart": "2013-06-24T23:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_26
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-25T00:00:00+02:00
2013-06-26T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-26T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-21T21:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Rig up tension cylinders, tension ring and centralizers.\nCut riser tension joint.\nInstall surface wellhead.\nInstall surface riser joint.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "29", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Ran production riser to wellhead.\nLanded and locked tieback connector on wellhead. \nPressure tested production riser and tieback connector to 200 bar.\n", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-25T18:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-25T17:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Picked up riser single #2 and positioned and landed off joint. Inspected seal surface and installed IX-14 ring. Made up flange connection with bolt tensioner. Pressure tested flange connection to 3000 psi through test port - ok. Lowered riser and set in riser spider.", "dTimEnd": "2013-06-25T02:30:00+02:00", "dTimStart": "2013-06-25T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up riser single #3 and positioned and landed off joint. Inspected seal surface and installed IX-14 ring. Made up flange connection with bolt tensioner. Pressure tested flange connection to 3000 psi through test port - ok. Lowered riser and set in riser spider.", "dTimEnd": "2013-06-25T04:30:00+02:00", "dTimStart": "2013-06-25T02:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up riser single #4 and positioned and landed off joint. Inspected seal surface and installed IX-14 ring. Made up flange connection with bolt tensioner. Pressure tested flange connection to 3000 psi through test port - ok. Lowered riser and set in riser spider.", "dTimEnd": "2013-06-25T07:00:00+02:00", "dTimStart": "2013-06-25T04:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to pick up splash zone riser joint.", "dTimEnd": "2013-06-25T07:15:00+02:00", "dTimStart": "2013-06-25T07:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up splash zone riser joint and landed off joint. Inspected seal surface and installed IX-14 ring. Made up flange connection with bolt tensioner. Pressure tested flange connection to 3000 psi through test port - ok. Lowered riser and set in riser spider.", "dTimEnd": "2013-06-25T08:45:00+02:00", "dTimStart": "2013-06-25T07:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up upper riser pup joint and positioned and landed off joint. Inspected seal surface and installed IX-14 ring. Made up flange connection with bolt tensioner. Pressure tested flange connection to 3000 psi through test port - ok. Lowered riser and set in riser spider.", "dTimEnd": "2013-06-25T10:30:00+02:00", "dTimStart": "2013-06-25T08:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up tension joint and landed off joint. Inspected seal surface and installed IX-14 ring. Made up flange connection with bolt tensioner. Pressure tested flange connection to 3000 psi through test port - ok. Lowered riser and set in riser spider.", "dTimEnd": "2013-06-25T12:00:00+02:00", "dTimStart": "2013-06-25T10:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Modified flange protector clamp straps. Installed protector clamps.", "dTimEnd": "2013-06-25T14:00:00+02:00", "dTimStart": "2013-06-25T12:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lowered riser and attached hang off plate. Locked spider and landed off weight.", "dTimEnd": "2013-06-25T14:15:00+02:00", "dTimStart": "2013-06-25T14:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed riser running tool from riser tension joint.", "dTimEnd": "2013-06-25T14:30:00+02:00", "dTimStart": "2013-06-25T14:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and made up 5 1/2\" drill pipe with riser running tool and tension riser joint. Picked up weight and removed hangoff plate.", "dTimEnd": "2013-06-25T15:30:00+02:00", "dTimStart": "2013-06-25T14:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to remove riser spider.", "dTimEnd": "2013-06-25T15:45:00+02:00", "dTimStart": "2013-06-25T15:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed riser spider. Installed outer ring and master bushings.", "dTimEnd": "2013-06-25T17:15:00+02:00", "dTimStart": "2013-06-25T15:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Made up top drive to 5 1/2\" drill pipe and riser. Spaced out to install needle valve. Ensured needle valve secured for running.", "dTimEnd": "2013-06-25T17:30:00+02:00", "dTimStart": "2013-06-25T17:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lowered riser to safe distance above riser landing guide funnel. Verified VGX ring in correct position. Lowered riser inside vertical guide. Removed riser guide funnel.", "dTimEnd": "2013-06-25T19:00:00+02:00", "dTimStart": "2013-06-25T17:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lowered hot stab to tieback connector. Installed hot stab using ROV.", "dTimEnd": "2013-06-25T19:30:00+02:00", "dTimStart": "2013-06-25T19:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Landed off tieback connector on wellhead with 15MT. Functioned valves on ROV panel to lock tieback connector.", "dTimEnd": "2013-06-25T19:45:00+02:00", "dTimStart": "2013-06-25T19:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Applied 3000 psi until stroke indicator indicated fully set.", "dTimEnd": "2013-06-25T20:30:00+02:00", "dTimStart": "2013-06-25T19:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and applied 20MT overpull to verify latched production riser.", "dTimEnd": "2013-06-25T20:45:00+02:00", "dTimStart": "2013-06-25T20:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up to perform pressure test of riser.", "dTimEnd": "2013-06-25T21:00:00+02:00", "dTimStart": "2013-06-25T20:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Filled riser with water using cement unit while venting through tension joint.", "dTimEnd": "2013-06-25T21:45:00+02:00", "dTimStart": "2013-06-25T21:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to perform pressure test to 20/200 bar for 5/10 minutes.", "dTimEnd": "2013-06-25T22:00:00+02:00", "dTimStart": "2013-06-25T21:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested riser to 20/200 bar for 5/10 minutes. Pumped 320 liters. Bled 320 liters back.", "dTimEnd": "2013-06-25T22:45:00+02:00", "dTimStart": "2013-06-25T22:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened needle valve on tension joint to drain string. Closed needle valve.", "dTimEnd": "2013-06-25T23:00:00+02:00", "dTimStart": "2013-06-25T22:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Flushed tieback connector control lines with inhibitor using the mini reel pump.", "dTimEnd": "2013-06-26T00:00:00+02:00", "dTimStart": "2013-06-25T23:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_27
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-26T00:00:00+02:00
2013-06-27T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-27T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-21T21:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Install surface riser and BOP.\nInstall bowl protector.\nWash multibowl.\nRIH and retrieve bowl protector.\nRig up and run 10 3/4\" tie back string.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "30", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Installed tie back connector.\nInstalled riser centralizers, tension ring and tension cylinders.\nCut off and bevelled riser tension joint.\nLanded multibowl.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-26T18:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-26T15:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Flushed tieback connector control lines with inhibitor using the mini reel pump.\nSat all valves to parking position. \nRecovered hot stab and guide wires to surface. \nInstalled dummy stab in tieback connector.", "dTimEnd": "2013-06-26T01:15:00+02:00", "dTimStart": "2013-06-26T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed riser centralizers, tension ring and tension cylinders.\n\nMeanwhile: \nPressure tested BOP to 345 bar on stump.\n\nPerformed pre-job meeting prior to cut and bevel the riser tension joint.", "dTimEnd": "2013-06-26T10:00:00+02:00", "dTimStart": "2013-06-26T01:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cut the riser tension joint while holding 2-4 Ton overpull in string.\nLaid out cut off riser piece and riser cutting equipment.\n\nMeanwhile: \nPressure tested BOP to 345 bar on stump.\n", "dTimEnd": "2013-06-26T13:30:00+02:00", "dTimStart": "2013-06-26T10:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Bevelled riser tension joint edge.\n\nHeld pre-job / SJA meeting prior to pick up Claxton tool and BOP joint.", "dTimEnd": "2013-06-26T15:30:00+02:00", "dTimStart": "2013-06-26T13:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and sat multibowl in rotary, inspected NT2 connection, ok.\nPicked up surface joint / Claxton tool assembly and made up same to multibowl.\nPerformed pick up test of assembly to 0,15 meter above deck.\nPicked up assembly and removed master bushings.\nRan assembly through rotary.\nInstalled master bushings.\nPicked up single and ran in with multibowl.\nLanded out multibowl.", "dTimEnd": "2013-06-26T21:30:00+02:00", "dTimStart": "2013-06-26T15:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Tested multibowl BT and FS seals.\nEnergized plastic in uppper and lower BT seals.\n\nMeanwhile: \nAttempted to pressure test annular BOP on stump.\n\n\n", "dTimEnd": "2013-06-27T00:00:00+02:00", "dTimStart": "2013-06-26T21:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_28
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-27T00:00:00+02:00
2013-06-28T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-28T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-21T21:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Retrieve annulus insert.\nRig up and run 10 3/4\" tie back string.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "31", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Replaced annular preventer.\nInstalled surface riser and BOP.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-27T18:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-27T15:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Energized multibowl slips.\nPerformed 5 Ton overpull test, ok.\n\nMeanwhile: \nPressure tested annular BOP to 20 / 345 bar on stump.\nNot able to obtain test. \nCommenced to replace annular element.", "dTimEnd": "2013-06-27T02:00:00+02:00", "dTimStart": "2013-06-27T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed hatches around production riser.\n\nMeanwhile: \nReplacing annular preventer.", "dTimEnd": "2013-06-27T02:30:00+02:00", "dTimStart": "2013-06-27T02:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed control hose reel and pump for Claxton tool on drill floor.\n\nMeanwhile: \nReplacing annular preventer.", "dTimEnd": "2013-06-27T03:30:00+02:00", "dTimStart": "2013-06-27T02:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Erected scaffolding around Claxton tool in moonpool.\n\nMeanwhile: \nReplacing annular preventer.", "dTimEnd": "2013-06-27T05:30:00+02:00", "dTimStart": "2013-06-27T03:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to disengage Claxton tool with 1500 psi on piston.\nNot able to release tool.\nIncreased pressure to 1800 psi and released Claxton tool.\n\nMeanwhile: \nReplacing annular preventer.", "dTimEnd": "2013-06-27T07:30:00+02:00", "dTimStart": "2013-06-27T05:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting.\nPulled out with Claxton tool and laid down same to cantilever deck.\n\nMeanwhile: \nReplacing annular preventer.\nWorked with installation of valves and test of multibowl.", "dTimEnd": "2013-06-27T09:30:00+02:00", "dTimStart": "2013-06-27T07:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Replaced annular preventer.\nFunction tested annular preventer twice prior to pressure test.\nPressure tested annular preventer to 30 / 345 bar - 5 / 10 minutes, test ok.\n\nMeanwhile:\nWorked with installation of valves and test of multibowl.\nPerformed maintenance on TDS.\nMoved slick joint and diverter to drill floor.\nAt 17:00 hrs informed PCR to shut down production on well F-12 and F-14.\n", "dTimEnd": "2013-06-27T18:00:00+02:00", "dTimStart": "2013-06-27T09:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed pre-job meeting prior to nipple up BOP.\nMoved BOP to well center and landed same onto riser.\nMade up NT2 connector.\nConnected tension system.\nRan slick joint and made up same.\nAt 23:15 hrs informed PCR to restart production on well F-12 and F-14.", "dTimEnd": "2013-06-28T00:00:00+02:00", "dTimStart": "2013-06-27T18:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_29
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-28T00:00:00+02:00
2013-06-29T00:00:00+02:00
normal
2018-05-03T13:51:36+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-29T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-28T01:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Install tie-back connector and pressure test same.\nInstall adjustable surface hanger and test same.\nRun seal assembly.\nTest BOP connection.\nSlip and cut drill line.\nPull Safelock plug.\n", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "32", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Retrieved annulus insert.\nRIH with tie-back string.\n\n", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-28T21:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Pulled master bushings.\nInstalled diverter.", "dTimEnd": "2013-06-28T01:00:00+02:00", "dTimStart": "2013-06-28T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed BX elevator and rotator.\nChanged handling equipment to 5 1/2\".\nPicked up bowl protector RT and made up same to 5 1/2\" DP.\nRIH and installed bowl protector.\nPOOH with RT.", "dTimEnd": "2013-06-28T02:45:00+02:00", "dTimStart": "2013-06-28T01:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and RIH with annulus insert retrieval tool.\nTagged and engaged annulus insert at 140,2 meter, Not able to release annulus insert.\nPOOH with RT.\nRedressed RT, replaced torque pins with torque keys.\nRan back in with RT and engaged same.\nReleased annulus insert with 4000 Nm.\nPOOH with RT and redressed same with torque pins.\nRIH and retrieved annulus insert.\nBroke out and laid down annulus RT to cantilever.", "dTimEnd": "2013-06-28T08:30:00+02:00", "dTimStart": "2013-06-28T02:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior to clean out run.\nPicked up and made up jetting sub to 5 1/2\" DP.\nRIH with jetting sub on 5 1/2\" DP from surface to 150 m.\nPumped 13 m3 hi-vis pill with 500 liter/min, 4 bar. \nChased pill with 4,5 m3 SW at 500 liter/min, 2,8 bar. \nStopped pumping and RIH from 150 m to 170 m.\nWaited for pill to soak for 10 minutes.\nCommenced circulation with SW between 170 m - 135 m at 3000 liter/min, 26 bar, 10 rpm, 1-3 kNm. \nDisplaced well back to 26 m3 1,03 sg inhibited brine with 3000 liter/min, 26 bar.\nPOOH and laid down jet sub.", "dTimEnd": "2013-06-28T12:30:00+02:00", "dTimStart": "2013-06-28T08:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Strapped DP stands from derrick.", "dTimEnd": "2013-06-28T13:45:00+02:00", "dTimStart": "2013-06-28T12:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior to retrieving bowl protector.\nRIH with bowl protector retrieval tool and retrieved same.\nPOOH with bowl protector.", "dTimEnd": "2013-06-28T14:30:00+02:00", "dTimStart": "2013-06-28T13:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to rig up.\nRigged up handling equipment for 10 3/4\" tie-back casing.", "dTimEnd": "2013-06-28T17:15:00+02:00", "dTimStart": "2013-06-28T14:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior make up setting tool.\nPicked up and racked back adjustable surface hanger setting tool.", "dTimEnd": "2013-06-28T20:00:00+02:00", "dTimStart": "2013-06-28T17:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cleaned and cleared rigfloor.\nInstalled large head for 10 3/4\" casing handling in PDM.\nPerformed pre-job meeting prior to run 10 3/4\" tie-back string.", "dTimEnd": "2013-06-28T21:00:00+02:00", "dTimStart": "2013-06-28T20:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up 10 3/4\" tie-back connector, inspected same, ok.\nPicked up and RIH with 10 3/4\" tie-back string as per running tally from surface to 103 meter.\n", "dTimEnd": "2013-06-28T23:15:00+02:00", "dTimStart": "2013-06-28T21:00:00+02:00", "md": "103", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up 10 3/4\" surface casing hanger assembly with adjustment sub and continued to RIH.\n", "dTimEnd": "2013-06-29T00:00:00+02:00", "dTimStart": "2013-06-28T23:15:00+02:00", "md": "123", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_06_30
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-29T00:00:00+02:00
2013-06-30T00:00:00+02:00
normal
2018-05-03T13:51:37+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-06-30T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-28T01:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Test BOP connection.\nSlip and cut drill line.\nPull Safelock plug.\nRig up for completion.\n", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "33", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Installed tie-back connector and pressure tested same.\nInstalled adjustable surface hanger and tested same.\nRan seal assembly.\n", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-29T21:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-29T20:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" }, { "dTim": "2013-06-29T22:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Tagged land off point with 3 Ton.\nLanded off tie-back string at 139,73 meter\nRotated string with two turns to engage threads in tie-back adapter.", "dTimEnd": "2013-06-29T01:00:00+02:00", "dTimStart": "2013-06-29T00:00:00+02:00", "md": "139.7", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Released riser RT and POOH with same.", "dTimEnd": "2013-06-29T01:30:00+02:00", "dTimStart": "2013-06-29T01:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged down handling equipment for 10 3/4\" tie-back casing and cleared rig floor.\nRigged up for handling of 5 1/2\" DP.", "dTimEnd": "2013-06-29T03:00:00+02:00", "dTimStart": "2013-06-29T01:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and made up tie-back torque tool.\nMeanwhile drained riser.\n", "dTimEnd": "2013-06-29T03:30:00+02:00", "dTimStart": "2013-06-29T03:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with tie-back connector torque tool on 5 1/2\" DP.\nLanded and engaged torque tool in tie-back adapter at 139,26 meter.\nMade up tie-back connection to 13300 Nm, turned string 5 3/4 RH turns. \n\n", "dTimEnd": "2013-06-29T05:30:00+02:00", "dTimStart": "2013-06-29T03:30:00+02:00", "md": "139.3", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with tie-back connector torque tool on 5 1/2\" DP.", "dTimEnd": "2013-06-29T06:00:00+02:00", "dTimStart": "2013-06-29T05:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up handling equipment for 10 3/4\" tie-back casing.\nHeld toolbox talk.", "dTimEnd": "2013-06-29T07:15:00+02:00", "dTimStart": "2013-06-29T06:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up casing hanger landing string and RIH to top of casing hanger at 20,9 meter.\nEngaged CHRT with 6 left hand turns.", "dTimEnd": "2013-06-29T08:45:00+02:00", "dTimStart": "2013-06-29T07:15:00+02:00", "md": "20.9", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to test tie-back adapter.\nRigged up swedge and hose for tie-back connector test.\nFlushed lines and tested lines to 345 bar for 5 minutes.\nPressure tested tie-back connector to 20 / 345 bar - 5 / 10 minutes. Pumped 466 liters, bled back 461 liters.\nRigged down swedge and hose.", "dTimEnd": "2013-06-29T10:45:00+02:00", "dTimStart": "2013-06-29T08:45:00+02:00", "md": "20.9", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up adjustable sub setting tool and RIH with same to 28,67 m", "dTimEnd": "2013-06-29T11:30:00+02:00", "dTimStart": "2013-06-29T10:45:00+02:00", "md": "28.7", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Applied 133 bar, picked up 2 Ton, bleed off pressure.\nTurned string 13 turns and picked up with 30 Ton overpull. Continued to turn untill 9000 Nm torque achieved. Total 14 1/4 turns.\nObserved correct movement through annulus port on surface WH.\nFinal tension 30 Ton.", "dTimEnd": "2013-06-29T12:00:00+02:00", "dTimStart": "2013-06-29T11:30:00+02:00", "md": "28.7", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with adjustable sub setting tool and racked back in derrick.\nChanged to 10 3/4\" handling equipment.\nMade up 10 3/4\" x 2002 weco swedge.\nPressure tested adjustable sub internal seal to 30 / 375 bar - 5 / 10 minutes. \nPumped 446 liters, bled back 446 liters.\nRigged down hose and swedge.\nDisengaged CHRT with 6 right hand turns.\nPOOH with CHRT from 20,89 meter to surface.\nBroke out and laid down CHRT to cantilever.\nRigged down 10 3/4\" casing handling equipment and rigged up for handling 5 1/2\" DP.", "dTimEnd": "2013-06-29T18:00:00+02:00", "dTimStart": "2013-06-29T12:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up 10 3/4\" MS-T seal assembly RT and made up same to 5 1/2\" DP double.\nConnected hydraulic lines to RT and flushed through same.\nFunction tested 10 3/4\" MS-T seal assembly RT.\nInstalled MS-T seal on RT.", "dTimEnd": "2013-06-29T20:15:00+02:00", "dTimStart": "2013-06-29T18:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 10 3/4\" MS-T seal assembly and landed off at 20,86 meter.\nAttempted to lock RT into riser.\nNot able to lock RT into riser due to internal hydraulic leak i RT.", "dTimEnd": "2013-06-29T21:00:00+02:00", "dTimStart": "2013-06-29T20:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with 10 3/4\" MS-T seal assembly.\nPicked up backup 10 3/4\" MS-T seal assembly RT and tested same hydraulically.\nVerified RT measurements.\nRIH with backup 10 3/4\" MS-T seal assembly and landed same at 20,86 meter.", "dTimEnd": "2013-06-29T23:00:00+02:00", "dTimStart": "2013-06-29T21:00:00+02:00", "md": "20.9", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Sat MS-T seal assembly.", "dTimEnd": "2013-06-30T00:00:00+02:00", "dTimStart": "2013-06-29T23:00:00+02:00", "md": "20.9", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_01
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-06-30T00:00:00+02:00
2013-07-01T00:00:00+02:00
normal
2018-05-03T13:51:37+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-01T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-30T14:15:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run completion", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "34", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Slipped and cut drill line.\nPulled Safelock plug.\nRigged up for completion.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-06-30T13:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-06-30T21:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Tested seal assembly to 345 bar - 10 minutes through multibowl test port. \nPOOH with 10 3/4\" MS-T seal assembly RT and laid down same.\n", "dTimEnd": "2013-06-30T01:15:00+02:00", "dTimStart": "2013-06-30T00:00:00+02:00", "md": "20.9", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox talk.\nLined up to pressure test BOP connection and shear ram against Safe lock plug.\nPerformed pressure test to 30 / 345 bar - 5 / 10 minutes.\nPumped 553 liters, bled back 553 liters.\n", "dTimEnd": "2013-06-30T02:00:00+02:00", "dTimStart": "2013-06-30T01:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up bowl protector RT and made up same to 5 1/2\" DP.\nRIH and installed bowl protector at 20,45 m.\n", "dTimEnd": "2013-06-30T03:00:00+02:00", "dTimStart": "2013-06-30T02:00:00+02:00", "md": "20.5", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with RT.", "dTimEnd": "2013-06-30T03:15:00+02:00", "dTimStart": "2013-06-30T03:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up, slipped and cut drill line.\nCalibrated drawworks after slip and cut job. \nCleaned and cleared rig floor.", "dTimEnd": "2013-06-30T07:15:00+02:00", "dTimStart": "2013-06-30T03:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to retrieve Safe Lock plug.", "dTimEnd": "2013-06-30T07:30:00+02:00", "dTimStart": "2013-06-30T07:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up Safe Lock plug RT and made up to 5 1/2\" DP.\nRIH with Safe Lock plug RT on 5 1/2\" DP from surface to 611 m with restricted speed.\nAt 611 meter made up TDS and commenced washing down to 629 meter with 300 liter, 3 bar.\nIncreased flow rate to 2000 liter/min, 13 bar and displaced hi-pill out of well between 629 m - 621 m.\nDecreased rate to 300 liter/min, 3-4 bar and washed back down to 629 meter.\nContinued to wash down with 150 liter/min to top of plug at 631,6 m.\n\n\n", "dTimEnd": "2013-06-30T10:45:00+02:00", "dTimStart": "2013-06-30T07:30:00+02:00", "md": "611", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Latched onto plug at 4. attempt.\nSat down 20 Ton on plug, rotated string 1/2 RH turn, took 15 Ton overpull.\nSlacked off 2 Ton weight and applied 35 bar, observed pressure drop to 15 bar, bleed off pressure to 0 bar. \nTook 2 ton overpull and rotated 24 right hand turns to release plug, pulled plug free up to 627 meter.\nPerformed flow check for 10 minutes, ok.\nRIH to below plug setting point to ensure plug was retrieved and free, ok.\n", "dTimEnd": "2013-06-30T11:45:00+02:00", "dTimStart": "2013-06-30T10:45:00+02:00", "md": "631", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior to POOH.\nPOOH with Safe Lock plug on 5 1/2\" DP from 639 m to surface with restricted speed.\nInspected Safe Lock plug and RT, laid down same to cantilever.\n", "dTimEnd": "2013-06-30T14:15:00+02:00", "dTimStart": "2013-06-30T11:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cleaned and cleared rigfloor.\nPicked up bowl protector RT and made up same to 5 1/2\" DP.\nRIH to 20,55 meter and attemped to retrieve bowl protector.\nPOOH with RT only.\nInspected RT and RIH to 20,55 meter and retrieved bowl protector.\nPOOH with bowl protector.\n", "dTimEnd": "2013-06-30T15:45:00+02:00", "dTimStart": "2013-06-30T14:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested upper / lower IBOP's and kelly hose to 20 / 345 bar - 5 /10 minutes.\n\nMeanwhile:\nRigged up for running 7\" completion string.", "dTimEnd": "2013-06-30T19:00:00+02:00", "dTimStart": "2013-06-30T15:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to rig up tubing equipment.\nChanged to 7\" handling gear, BX elevators, installed rotator, adjusted link tilt function.\nMade up kick stand and racked back in derrick.\nInstalled 7\" casing tong and tested same.", "dTimEnd": "2013-06-30T20:45:00+02:00", "dTimStart": "2013-06-30T19:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed Vario spider slips and tested same.\nRigged up cable drums on rigfloor and installed sheave for DHPG.\nPrepared completion assembly #1 and #2 on deck.", "dTimEnd": "2013-07-01T00:00:00+02:00", "dTimStart": "2013-06-30T20:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_02
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-01T00:00:00+02:00
2013-07-02T00:00:00+02:00
normal
2018-05-03T13:51:37+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-02T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-30T14:15:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run completion.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "35", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Rigged up to run completion.\nRan completion.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-07-01T11:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Rigged up cable drums on rigfloor and installed sheave for DHPG.\nPrepared completion assembly #1 and #2 on deck.\nPerformed pre-job meeting with all involved personnel prior to run completion string.", "dTimEnd": "2013-07-01T01:30:00+02:00", "dTimStart": "2013-07-01T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and RIH 7\" completion from surface to 67 meter.\nAssembly #1 with 7\" perforated stem and mule shoe.\nAssembly #2 with pre installed EVO plug and auto fill valve.\nAssembly #3 with BOT Granite packer.\n2 ea. plain 7\" tubing joints.\nAssembly #4 with DHPG.\n1 ea. plain 7\" tubing joint.\n", "dTimEnd": "2013-07-01T04:00:00+02:00", "dTimStart": "2013-07-01T01:30:00+02:00", "md": "67", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Terminated cable to Down Hole Temperature and Pressure Gauge.\nFunction tested DHPG.", "dTimEnd": "2013-07-01T05:45:00+02:00", "dTimStart": "2013-07-01T04:00:00+02:00", "md": "67", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 7\" tubing from 67 m to 715 m \nAverage running speed 4 joints/hr. \nTotal rejected joints 2.\nObserved trouble with belt on HTS.", "dTimEnd": "2013-07-01T20:30:00+02:00", "dTimStart": "2013-07-01T05:45:00+02:00", "md": "715", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot on HTS belt sensor.", "dTimEnd": "2013-07-01T21:00:00+02:00", "dTimStart": "2013-07-01T20:30:00+02:00", "md": "715", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with 7\" tubing from 715 m to 913 m \nAverage running speed 5,5 joints/hr. \nTotal rejected joints 2.", "dTimEnd": "2013-07-02T00:00:00+02:00", "dTimStart": "2013-07-01T21:00:00+02:00", "md": "913", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_03
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-02T00:00:00+02:00
2013-07-03T00:00:00+02:00
normal
2018-05-03T13:51:37+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-03T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-30T14:15:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run completion.\nPick up and install DHSV.\nContinue to RIH with completion string.\n\n", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "36", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with 7\" tubing from 971 m to 2035 m ", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-07-02T21:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-07-02T16:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "RIH with 7\" tubing from 913 m to 971 m \nAverage running speed 2 joints/hr. \nTotal rejected joints 2.\nObserved hydraulic leak from elevator fitting.", "dTimEnd": "2013-07-02T02:00:00+02:00", "dTimStart": "2013-07-02T00:00:00+02:00", "md": "971", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Replaced broken hydraulic fitting on elevator.", "dTimEnd": "2013-07-02T02:15:00+02:00", "dTimStart": "2013-07-02T02:00:00+02:00", "md": "971", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with 7\" tubing from 971 m to 1232 m \nAverage running speed 4,5 joints/hr. \nTotal rejected joints 3.", "dTimEnd": "2013-07-02T07:00:00+02:00", "dTimStart": "2013-07-02T02:15:00+02:00", "md": "1232", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting.\nReplaced tubing elevators to improve vertical alignment of tubing.", "dTimEnd": "2013-07-02T07:45:00+02:00", "dTimStart": "2013-07-02T07:00:00+02:00", "md": "1232", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 7\" tubing from 1232 m to 1316 m \nAverage running speed 1 joints/hr. \nTotal rejected joints 9\nHigh pressure cleaned and re-doped all pins and boxes.", "dTimEnd": "2013-07-02T14:00:00+02:00", "dTimStart": "2013-07-02T07:45:00+02:00", "md": "1316", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 7\" tubing from 1316 m to 1500 m \nAverage running speed 4,5 joints/hr. \nRunning speed reduced due continous alignment checking and optimizing.\nTotal rejected joints 0.\n\nHeld pre-job meeting prior to adjust alignment on TDS.", "dTimEnd": "2013-07-02T17:30:00+02:00", "dTimStart": "2013-07-02T14:00:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Adjusted TDS alignment.", "dTimEnd": "2013-07-02T17:45:00+02:00", "dTimStart": "2013-07-02T17:30:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 7\" tubing from 1500 m to 2035 m \nAverage running speed 7 joints/hr. \nTotal rejected joints 0.", "dTimEnd": "2013-07-03T00:00:00+02:00", "dTimStart": "2013-07-02T17:45:00+02:00", "md": "2035", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_04
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-03T00:00:00+02:00
2013-07-04T00:00:00+02:00
normal
2018-05-03T13:51:37+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-04T00:00:00+02:00", "dTimDiaHoleStart": "2013-06-30T14:15:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH with completion string to TOL.\nPull back and install spaceout pups\nInstall tubing hanger.\n\n", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "37", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with 7\" tubing from 2035 m to 2612 m.\nPicked up DHSV.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-07-03T16:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" }, { "dTim": "2013-07-03T23:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "RIH with 7\" tubing from 2035 m to 2589 m \nAverage running speed 4 joints/hr. \nTotal rejected joints 7.", "dTimEnd": "2013-07-03T11:15:00+02:00", "dTimStart": "2013-07-03T00:00:00+02:00", "md": "2589", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to run DHSV.\nInstalled sheave for DHSV control line in PRS.\nPicked up and made up assembly #5 DHSV and made up same to string.\nRIH with completion string from 2589 m to 2595 m.\nInstalled and terminated DHSV control lines.\nTested DHSV control lines to 520 bar, bled back 370 ml.\nTested DHSV control lines to 345 bar and maintained DHSV open while contiue to RIH from 2595 m to 2612 m.\n", "dTimEnd": "2013-07-03T15:30:00+02:00", "dTimStart": "2013-07-03T11:15:00+02:00", "md": "2612", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "At 20,55 meter below rotary observed string taking 15 Ton weight.\nNot able to enter centralizer on assembly #5 into 10 3/4\" casing in multi-bowl.\nPicked up string.\nAttempted to run through multi-bowl, still observing string taking weight.\nPulled out to inspect DHSV assembly for contact marks, no marks observed.\nObserved rig not proper alignet above well.", "dTimEnd": "2013-07-03T19:00:00+02:00", "dTimStart": "2013-07-03T15:30:00+02:00", "md": "2612", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Prepared for skidding rig.", "dTimEnd": "2013-07-04T00:00:00+02:00", "dTimStart": "2013-07-03T19:00:00+02:00", "md": "2612", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_05
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-04T00:00:00+02:00
2013-07-05T00:00:00+02:00
normal
2018-05-03T13:51:37+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-05T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-04T20:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Land and test hanger.\nSet production packer.\nRetrieve EVO plug.\n", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "38", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with completion string to TOL.\nPulled back and installed spaceout pups\nInstalled tubing hanger.\n\n", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-07-04T23:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" }, { "dTim": "2013-07-04T20:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "4770", "mudClass": "water based", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "NaCl brine", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Prepared for skidding rig.\nHeld pre-job meeting prior to skid.\nSkidded rig 15 cm forward.\nAttempted to run through multi-bowl, still observing string taking weight.\nPulled out to inspect DHSV assembly for contact marks, no marks observed.\nRan back in with DHSV assembly, sat down 10 - 15 Ton weight on 10 3/4\" casing stump, passed through. \n", "dTimEnd": "2013-07-04T01:30:00+02:00", "dTimStart": "2013-07-04T00:00:00+02:00", "md": "2612", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 7\" tubing from 2612 m to 2798 m. \nAverage running speed 5 joints/hr. \nTotal rejected joints 0.", "dTimEnd": "2013-07-04T05:00:00+02:00", "dTimStart": "2013-07-04T01:30:00+02:00", "md": "2798", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Replaced elevator due to trouble with latch function.", "dTimEnd": "2013-07-04T05:30:00+02:00", "dTimStart": "2013-07-04T05:00:00+02:00", "md": "2798", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 7\" tubing from 2798 m to 3066 m. \nAverage running speed 4,5 joints/hr.", "dTimEnd": "2013-07-04T10:30:00+02:00", "dTimStart": "2013-07-04T05:30:00+02:00", "md": "3066", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Recorded up / down weights, 186 / 139 Ton.\nChanged to 5 1/2\" DP elevators.\nRigged down sheaves for control lines.\nPicked up pre-made DP landing stand and made up to tubing string.\nInstalled masterbushings and manual slips.", "dTimEnd": "2013-07-04T12:15:00+02:00", "dTimStart": "2013-07-04T10:30:00+02:00", "md": "3066", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to RIH.\nWashed down with 7\" tubing on 5 1/2\" DP from 3066 m to 3099,7 m at 150 liter/min, sat down 5 Ton on PBR no go.\nPulled back 4,5 meter out of PBR and increased rate to 220 liter/min. \nStung into PBR to confirm depth, observed small pressure peak when stinging in.\nContinued to RIH and confirmed depth by setting down 5 Ton onto PBR no go at 3099,7 meter.\n", "dTimEnd": "2013-07-04T14:30:00+02:00", "dTimStart": "2013-07-04T12:15:00+02:00", "md": "3099.7", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up until weight observed.\nMarked pipe.\nPOOH with 7\" tubing on 5 1/2\" DP. Strapped pipe while POOH.\nBroke out landing string.\nReplaced box on joint 14 due to poor threads.\n\nMeanwhile:\nPrepared space out and picked up space out joints from cantilever.", "dTimEnd": "2013-07-04T19:00:00+02:00", "dTimStart": "2013-07-04T14:30:00+02:00", "md": "3099.7", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting.\nMade up two space out joints and RIH from 3099,7 m to 3075,7 m.", "dTimEnd": "2013-07-04T20:00:00+02:00", "dTimStart": "2013-07-04T19:00:00+02:00", "md": "3075.7", "phase": "fixed", "proprietaryCode": "completion -- completion string", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Made up tubing hanger to space out joint.\nFed the control lines through hanger and terminated same.\n", "dTimEnd": "2013-07-05T00:00:00+02:00", "dTimStart": "2013-07-04T20:00:00+02:00", "md": "3075.7", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_06
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-05T00:00:00+02:00
2013-07-06T00:00:00+02:00
normal
2018-05-03T13:51:37+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-06T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-04T20:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run BPV plug.\nNipple down BOP.\nInstall XMT.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "39", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Landed and tested hanger.\nSat production packer.\nRetrieved EVO plug.\nPressure tested production packer from below.\n", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-07-05T16:00:00+02:00", "density": "1.32", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "4770", "mudClass": "oil based", "presBopRating": "345", "pv": "36", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Leak tested all penetrations / fittings to 35 / 450 bar - 5 / 10 minutes, ok", "dTimEnd": "2013-07-05T01:15:00+02:00", "dTimStart": "2013-07-05T00:00:00+02:00", "md": "3075.7", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed C-plate and landed tubing in same.\nBroke out handling tool.\nWrapped control and gauge lines 4 times around hanger neck.\n", "dTimEnd": "2013-07-05T03:30:00+02:00", "dTimStart": "2013-07-05T01:15:00+02:00", "md": "3075.7", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Connected lines to ports in communication collar.\nPicked up and connected tubing hanger RT to hanger with 8 LH turns.\nConnected DHSV control lines and tested same to 520 bar / 10 minutes.\nConnected tubing hanger RT control lines to GE reel.\nLeft 520 bar in DHSV control line.", "dTimEnd": "2013-07-05T04:45:00+02:00", "dTimStart": "2013-07-05T03:30:00+02:00", "md": "3075.7", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and made up landing joints to string.\nRIH with hanger and landed same on 7\" landing string from 3075,7 m to 3098,20 m. 1,27 meter stick up.\nVerified correct hanger land and seal integrity by testing to 70 bar - 5 min through ports on multi-bowl.\nEngaged tubing hanger lock down ring.\nPerformed pull test to 15 Ton overpull, ok.\n\nMeanwhile drained riser.", "dTimEnd": "2013-07-05T07:30:00+02:00", "dTimStart": "2013-07-05T04:45:00+02:00", "md": "3098.2", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested liner hanger seal to 35 / 345 bar - 5 / 10 min.\nOpened DHSV.", "dTimEnd": "2013-07-05T08:00:00+02:00", "dTimStart": "2013-07-05T07:30:00+02:00", "md": "3098.2", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up swedge and cement hose, tested same to 345 bar - 10 min.\n", "dTimEnd": "2013-07-05T10:00:00+02:00", "dTimStart": "2013-07-05T08:00:00+02:00", "md": "3098.2", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Dropped ball.", "dTimEnd": "2013-07-05T10:15:00+02:00", "dTimStart": "2013-07-05T10:00:00+02:00", "md": "3098.2", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Circulated ball down with 3500 liter/min, 32 bar, pressure increased to 70 bar at landing.\nHeld 70 bar pressure for 5 min to check integrity.", "dTimEnd": "2013-07-05T10:45:00+02:00", "dTimStart": "2013-07-05T10:15:00+02:00", "md": "3098.2", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Increased pressure to 345 bar and held same for 30 minutes to set packer.\nMeanwhile observed vent line on annulus A.\nBled pressure down to 280 bar.\nClosed DHSV\nBled pressure down to 210 bar and performed low pressure inflow test, 70 bar, 30 min.\nBled pressure down to 10 bar and performed high pressure inflow test, 280 bar, 10 min.\nBled pressure back to 0 bar and opened DHSV.\n\n", "dTimEnd": "2013-07-05T14:15:00+02:00", "dTimStart": "2013-07-05T10:45:00+02:00", "md": "3098.2", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up and tested connection from cement unit to A annulus.\nPerformed pressure test of production packer though A annulus to 35 / 345 bar, 5 / 10 min.", "dTimEnd": "2013-07-05T15:30:00+02:00", "dTimStart": "2013-07-05T14:15:00+02:00", "md": "3098.2", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior to rig up wireline equipment.\nRigged up wireline sheaves and equipment.\nMade up wireline tool string.", "dTimEnd": "2013-07-05T16:45:00+02:00", "dTimStart": "2013-07-05T15:30:00+02:00", "md": "3098.2", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with wireline tool string and retrieved EVO plug.\nWhile POOH observed stuck EVO plug inside DHG mandrel, jarred twice and continued to POOH to surface.\nLaid out EVO plug and wireline tool string.\nRigged down wireline sheaves and equipment.", "dTimEnd": "2013-07-05T22:30:00+02:00", "dTimStart": "2013-07-05T16:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested line up from cement unit to drill floor to 355 bar -10 minutes.\nPressure tested production packer from below to 345 bar- 30 minutes.", "dTimEnd": "2013-07-06T00:00:00+02:00", "dTimStart": "2013-07-05T22:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_07
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-06T00:00:00+02:00
2013-07-07T00:00:00+02:00
normal
2018-05-03T13:51:37+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-07T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-06T12:30:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Install XMT and test same.\nHandover well to Maersk production for XMT hookup.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "40", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Ran BPV plug.\nNippled down BOP.\nPrepared to install XMT.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Pressure tested production packer from below to 345 bar- 30 minutes.\nRigged down surface lines. \nClosed DHSV.", "dTimEnd": "2013-07-06T00:45:00+02:00", "dTimStart": "2013-07-06T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting.\nDisconnected tubing hanger RT by rotating 9 turns clockwise.\nPOOH with 7\" landing string and tubing hanger, laid out same.", "dTimEnd": "2013-07-06T02:15:00+02:00", "dTimStart": "2013-07-06T00:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged down tubing handling equipment.\nCleaned and cleared rigfloor.", "dTimEnd": "2013-07-06T04:30:00+02:00", "dTimStart": "2013-07-06T02:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up handling equipment for 3 1/2\" DP.\nPicked up and RIH with 6 3/8\" k-type BPV on 3 1/2\" DP.\nInstalled BPV and POOH with RT, laid out same.", "dTimEnd": "2013-07-06T06:15:00+02:00", "dTimStart": "2013-07-06T04:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to nipple down BOP.\nRigged up handling equipment for nipple job on rigfloor.\nNippled down diverter, pulled same to rigfloor and secured.\nRemoved riser tension cylinders.\nDisconnected BOP from HP riser and skidded same to stump.\nPulled riser to rigfloor.", "dTimEnd": "2013-07-06T12:30:00+02:00", "dTimStart": "2013-07-06T06:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Terminated contol lines on wellhead\n\nMeanwhile: \nLaid out HP riser onto HTS.\nPrepared spacer spool.", "dTimEnd": "2013-07-06T17:30:00+02:00", "dTimStart": "2013-07-06T12:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Run down with spacer spool and landed same on multi-bowl.\nMade up spacer spool and tested same.\n\nMeanwhile transportet scaffolding equipment up in derrick.", "dTimEnd": "2013-07-06T21:30:00+02:00", "dTimStart": "2013-07-06T17:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed A annulus test hose from wellhead deck.\nInstalled split hatches onto riser on tensioner deck.\nRemoved hatch from F-11.\nTransferred XMT from overhead crane TDS.\nNot able to run XMT through hatch.\n", "dTimEnd": "2013-07-07T00:00:00+02:00", "dTimStart": "2013-07-06T21:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_08
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-07T00:00:00+02:00
2013-07-08T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-08T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-06T12:30:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Terminate and test XMT.\nRig up for wireline.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "41", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Terminated XMT.\nPerformed planned maintenance .", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Removed Hatch from F-6.", "dTimEnd": "2013-07-07T01:30:00+02:00", "dTimStart": "2013-07-07T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran down and landed XMT onto spool.\nOrientation veryfied by laser.\nMade up XMT to spool piece.\nRemoved XMT lift cap and installed test cap.", "dTimEnd": "2013-07-07T02:45:00+02:00", "dTimStart": "2013-07-07T01:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed hatches on well F-11 and F-6.\nPerformed termination of control system and flowlines on XMT.\n\nMeanwhile:\nReplaced drill line guide.\nReplaced HTS belt.\nChanged out brake on TDS.\nWorked with installation of new flowline valve in shaker house.\n\nAt 16:00 hrs handed over the well to Maersk Production.", "dTimEnd": "2013-07-07T16:00:00+02:00", "dTimStart": "2013-07-07T02:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Erected scaffolding in derrick to enable access to aft PRS.\nWorked with installation of new flowline valve in shaker house.\n\nMeanwhile:\nPerformed termination of control system and flowlines on XMT.\n\n", "dTimEnd": "2013-07-08T00:00:00+02:00", "dTimStart": "2013-07-07T16:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_09
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-08T00:00:00+02:00
2013-07-09T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-09T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-06T12:30:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Rig up for wireline.\nPrepare equipment for perforation.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "42", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Terminated and tested XMT.\nRigged up for wireline.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Erected scaffolding in derrick to enable access to aft PRS.\nReplaced junction box aft PRS.\nPerformed planned maintenance on TDS and BOP.\nPrepared to rig up wireline equipment.\n\nMeanwhile:\nPerformed termination of control system and flowlines on XMT.\n\nAt 16:30 hrs the well was handed back from Maersk Production.", "dTimEnd": "2013-07-08T16:30:00+02:00", "dTimStart": "2013-07-08T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting.\nPressure tested XMT body and associated valves to 35 / 345 bar - 5 / 10 minutes.\n\n", "dTimEnd": "2013-07-09T00:00:00+02:00", "dTimStart": "2013-07-08T16:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_10
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-09T00:00:00+02:00
2013-07-10T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-10T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Perforate well.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "43", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Rigged up for wireline.\nPrepared equipment for perforation.\nMade up preforation tool string.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Removed XMT cap.\nRIH with BPV RT on tugger from rigfloor.\nRetrieved 6 3/8\" BPV and POOH with same.", "dTimEnd": "2013-07-09T00:45:00+02:00", "dTimStart": "2013-07-09T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "completion -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed F-11 hatch\nRigged up wireline BOP, riser and lubricator.", "dTimEnd": "2013-07-09T07:00:00+02:00", "dTimStart": "2013-07-09T00:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting.\nFilled riser with 100% MEG.\nLeak tested WL rig up to 30 / 200 bar - 5 / 10 min using cement pump.\nFunction tested WL BOP.\nConnected hoses to lubricator and grease injector head.\nMounted slings and sheaves in TDS \n", "dTimEnd": "2013-07-09T10:00:00+02:00", "dTimStart": "2013-07-09T07:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed test between tractor and WL interface.", "dTimEnd": "2013-07-09T13:15:00+02:00", "dTimStart": "2013-07-09T10:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up lower sheave.\nConnected tractor to wireline.\nStabbed lubricator section onto riser.\nPressure tested WL rig up with tractor only to 30 / 200 bar - 5 / 10 min using cement pump.\nDrained lubricator and broke out same.\n", "dTimEnd": "2013-07-09T15:15:00+02:00", "dTimStart": "2013-07-09T13:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to handling of toolstring.\nMade up WL toolstring with guns and RIH. ( Tool length: 29.86m, MAX OD:4.5 in, Tool Weight:1157.65 kg)\nArmed the guns.\nStabbed lubricator.\nPressure tested In-situ sub to 30 / 200 bar - 5 / 10 min.\n", "dTimEnd": "2013-07-09T22:00:00+02:00", "dTimStart": "2013-07-09T15:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened well according to procedure.\nWHP: 80bar", "dTimEnd": "2013-07-10T00:00:00+02:00", "dTimStart": "2013-07-09T22:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_11
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-10T00:00:00+02:00
2013-07-11T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-11T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH and perforate interval # 1. POOH with perforation BHA #1RR. M/U perforation BHA #2 and RIH.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "44", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with BHA # 1 from surface to 3700 m. Worked passed restriction at 3700 m and RIH to 3919 m. Lost communication with tractor. POOH and L/O BHA # 1. P/U and M/U BHA # 1RR and RIH to 3471 m.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "RIH with perforate BHA #1 on WL tractor from surface to 3700 meter.\nNot able to pass 3700 meter with string.\nPush with 1000 lbs with tractor.\nSimulations predicted 400 lbs push.", "dTimEnd": "2013-07-10T06:00:00+02:00", "dTimStart": "2013-07-10T00:00:00+02:00", "md": "3700", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Evaluated situation. Discussed situation with onshore organisation.", "dTimEnd": "2013-07-10T07:30:00+02:00", "dTimStart": "2013-07-10T06:00:00+02:00", "md": "3666", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. POOH with BHA # 1 from 3700 m to 3570 m and tested tractor.", "dTimEnd": "2013-07-10T08:15:00+02:00", "dTimStart": "2013-07-10T07:30:00+02:00", "md": "3570", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with BHA # 1 on WL tractor from 3570 m and passed restriction at 3700 m. RIH to 3919 m. Unable to communicate with tractor.", "dTimEnd": "2013-07-10T09:45:00+02:00", "dTimStart": "2013-07-10T08:15:00+02:00", "md": "3919", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Trouble shoot communication failure, No Go. Discussed situation with onshore organisation", "dTimEnd": "2013-07-10T10:30:00+02:00", "dTimStart": "2013-07-10T09:45:00+02:00", "md": "3919", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "POOH with BHA # 1 from 3919 m to 250 m.", "dTimEnd": "2013-07-10T13:15:00+02:00", "dTimStart": "2013-07-10T10:30:00+02:00", "md": "250", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Held TBT. POOH with BHA # 1 from 250 m to surface.", "dTimEnd": "2013-07-10T14:00:00+02:00", "dTimStart": "2013-07-10T13:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Closed in well. Drained and broke lubricator. Broke down tool string and L/O same.", "dTimEnd": "2013-07-10T17:15:00+02:00", "dTimStart": "2013-07-10T14:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Checked wire line tools and cable. \nMeanwhile: Checked tractor and found communication failure due to possible short circuit.", "dTimEnd": "2013-07-10T19:00:00+02:00", "dTimStart": "2013-07-10T17:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Held TBT. P/U and M/U BHA # 1RR. Stabbed lubricator on In-Situ Sub.", "dTimEnd": "2013-07-10T21:15:00+02:00", "dTimStart": "2013-07-10T19:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Pressure tested In-Situ Sub to 30/200 bar for 5/10 min.", "dTimEnd": "2013-07-10T21:30:00+02:00", "dTimStart": "2013-07-10T21:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Opened well and RIH with BHA #1RR on WL from surface to 3471 m (Tool length: 29.86m, MAX OD:4.5 in, Tool Weight:1157.65 kg)\nWHP: 80 bar", "dTimEnd": "2013-07-11T00:00:00+02:00", "dTimStart": "2013-07-10T21:30:00+02:00", "md": "3471", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_B_2013_07_12
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-11T00:00:00+02:00
2013-07-12T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-12T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "M/U perforation BHA # 2. RIH and perforate interval # 2.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "45", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with perforating BHA # 1RR to perforating depth at 4539 m. Perforated interval # 1. POOH to tool string inside tool catcher. \nWireline cable released from cablehead. Broke lubricator and secured tool string with C-plate. Verified guns fired and L/D lubricator and BHA # 1RR. ", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "RIH with BHA # 1RR from 3470 m to 3592 m.", "dTimEnd": "2013-07-11T00:30:00+02:00", "dTimStart": "2013-07-11T00:00:00+02:00", "md": "3700", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Engaged tractor and RIH with BHA # 1RR from 3592 m to 3700 m. .", "dTimEnd": "2013-07-11T00:45:00+02:00", "dTimStart": "2013-07-11T00:30:00+02:00", "md": "3700", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Unable to pass restriction at 3700 m . Attempted to work passed restriction from 3660 m to 3700 m.", "dTimEnd": "2013-07-11T03:00:00+02:00", "dTimStart": "2013-07-11T00:45:00+02:00", "md": "3700", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Pulled back to 3300 m. RIH with BHA # 1RR on wireline from 3300 m to 3557 m. Engaged tractor and RIH with BHA # 1RR on WL tractor from 3557 m to 3750 m. Performed pick-up test and confirmed tool depth.", "dTimEnd": "2013-07-11T04:15:00+02:00", "dTimStart": "2013-07-11T03:00:00+02:00", "md": "3750", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with BHA # 1RR on WL tractor from 3750 m to 3919 m", "dTimEnd": "2013-07-11T05:15:00+02:00", "dTimStart": "2013-07-11T04:15:00+02:00", "md": "3919", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with BHA # 1RR on WL tractor from 3919 m to 4570 m", "dTimEnd": "2013-07-11T07:00:00+02:00", "dTimStart": "2013-07-11T05:15:00+02:00", "md": "4570", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed correlation run from 4570 m to 3900 m. Observed wireline jumped spool grove.", "dTimEnd": "2013-07-11T12:00:00+02:00", "dTimStart": "2013-07-11T07:00:00+02:00", "md": "3900", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Payed out wireline and Re-spooled to 4160 m.", "dTimEnd": "2013-07-11T12:45:00+02:00", "dTimStart": "2013-07-11T12:00:00+02:00", "md": "4160", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed correlation run from 4160 m to 4580 m", "dTimEnd": "2013-07-11T14:15:00+02:00", "dTimStart": "2013-07-11T12:45:00+02:00", "md": "4580", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Bleed off well head pressure from 80 bar to 39 bar. Positioned guns at perforating interval # 1 between 4539 m to 4527 m and fired guns, Good indication of guns fired. Well head pressure stabilized at 34.7 bar.", "dTimEnd": "2013-07-11T14:30:00+02:00", "dTimStart": "2013-07-11T14:15:00+02:00", "md": "4539", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforating BHA # 1RR from 4539 m to surface. Observed wireline cable released from tool.", "dTimEnd": "2013-07-11T18:15:00+02:00", "dTimStart": "2013-07-11T14:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed in well on swap valve and hydraulic master valve [HMV]", "dTimEnd": "2013-07-11T18:30:00+02:00", "dTimStart": "2013-07-11T18:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Evaluated situation and formulated plan forward.", "dTimEnd": "2013-07-11T19:00:00+02:00", "dTimStart": "2013-07-11T18:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Inflow tested HMV with 5 bar for 10 min and purged lubricator with nitrogen.", "dTimEnd": "2013-07-11T20:30:00+02:00", "dTimStart": "2013-07-11T19:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator connection and secured perforating BHA # 1RR with C-plate. Picked-up and verified guns fired. Broke connection above guns and secured tool string inside lubricator and L/O same.", "dTimEnd": "2013-07-11T22:30:00+02:00", "dTimStart": "2013-07-11T20:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "POOH with gun assembly and L/O same.", "dTimEnd": "2013-07-11T23:30:00+02:00", "dTimStart": "2013-07-11T22:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Checked equipment and cleared rig floor", "dTimEnd": "2013-07-12T00:00:00+02:00", "dTimStart": "2013-07-11T23:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_B_2013_07_13
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-12T00:00:00+02:00
2013-07-13T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-13T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "M/U and RIH with perforation BHA # 3. Perforate interval # 3 and POOH to surface. L/O perforation BHA # 3", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "46", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "M/U perforation BHA # 2 and RIH to perforation depth. Perforated interval # 2 from 4480 m to 4500 m. POOH with perforation BHA # 2 and L/O guns.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Builed cablehead and function tested wireline tractor.", "dTimEnd": "2013-07-12T03:00:00+02:00", "dTimStart": "2013-07-12T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U wireline sheave. Tested interface between wireline tractor and logging tools Voltage Protection Module and Casing Collar Locator.", "dTimEnd": "2013-07-12T04:30:00+02:00", "dTimStart": "2013-07-12T03:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. P/U lubricator and wireline sheave.", "dTimEnd": "2013-07-12T05:00:00+02:00", "dTimStart": "2013-07-12T04:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U wireline tractor to cablehead. M/U lubricator and tested tractor communication.\nPressure tested In-situ sub to 30/200 bar, 5/10 min.", "dTimEnd": "2013-07-12T06:00:00+02:00", "dTimStart": "2013-07-12T05:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Displaced lubricator and pressure tested same to 30/345 bar for 5/10 min.", "dTimEnd": "2013-07-12T07:00:00+02:00", "dTimStart": "2013-07-12T06:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. Bleed off pressure and broke out lubricator. P/U and M/U perforation gun assembly #2.", "dTimEnd": "2013-07-12T10:45:00+02:00", "dTimStart": "2013-07-12T07:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U lubricator and pressure tested In-Situ Sub to 30/345 bar for 5/10 min.", "dTimEnd": "2013-07-12T11:15:00+02:00", "dTimStart": "2013-07-12T10:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Equalized wellhead pressure to 35 bar and opened well.", "dTimEnd": "2013-07-12T11:30:00+02:00", "dTimStart": "2013-07-12T11:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 2 on wireline from surface to 3360 m. (Tool length: 30.85m, MAX OD:4.5 in, Tool Weight: 1184.65 kg)\nWHP:34.7 bar", "dTimEnd": "2013-07-12T14:30:00+02:00", "dTimStart": "2013-07-12T11:30:00+02:00", "md": "3360", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 2 on wireline tractor from 3360 m to 4564 m.", "dTimEnd": "2013-07-12T16:30:00+02:00", "dTimStart": "2013-07-12T14:30:00+02:00", "md": "4564", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated across perforation interval and positioned gun with top shot at 4500 m . WHP 33 bar.", "dTimEnd": "2013-07-12T19:00:00+02:00", "dTimStart": "2013-07-12T16:30:00+02:00", "md": "4500", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Perforated interval from 4488 m to 4500 m. Wellhead pressure stabilized at 35 bar.", "dTimEnd": "2013-07-12T19:15:00+02:00", "dTimStart": "2013-07-12T19:00:00+02:00", "md": "4500", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforation BHA # 2 on wireline from 4500 m to surface. Closed well, inflow tested and bleed down to 0 bar.", "dTimEnd": "2013-07-12T23:00:00+02:00", "dTimStart": "2013-07-12T19:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. Broke lubricator and L/O guns.", "dTimEnd": "2013-07-13T00:00:00+02:00", "dTimStart": "2013-07-12T23:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_14
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-13T00:00:00+02:00
2013-07-14T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-14T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH with perforation BHA # 3RR. Correlate and perforate interval # 3. POOH and L/O BHA # 3RR. P/U and M/U perforation BHA # 4.", "hpht": "0", "md": "4768.7", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "47", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "L/O perforation BHA # 2. P/U and M/U perforation BHA # 3. RIH with BHA # 3 to 4420 m. Unable to communicate with tools. POOH with BHA # 3.\nTroubleshoot communication failure. Build new cablehead and P/U perforation BHA # 3RR.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "B/O and L/O perforation BHA # 2. Layed out wireline and cut same at cablehead.", "dTimEnd": "2013-07-13T01:30:00+02:00", "dTimStart": "2013-07-13T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Re-Build cablehead and prepared guns for perforation run # 3.", "dTimEnd": "2013-07-13T03:00:00+02:00", "dTimStart": "2013-07-13T01:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Tested interface between wireline tractor and logging tools Voltage Protection Module and Casing Collar Locator.", "dTimEnd": "2013-07-13T04:30:00+02:00", "dTimStart": "2013-07-13T03:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. P/U and M/U perforation BHA # 3. M/U lubricator and tested In-Situ Sub to 30/200 bar for 5/10 min.\n(Tool length: 30.85m, MAX OD:4.5 in, Tool Weight: 1184.65 kg)", "dTimEnd": "2013-07-13T06:00:00+02:00", "dTimStart": "2013-07-13T04:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 3 from surface to 4420 m.", "dTimEnd": "2013-07-13T11:15:00+02:00", "dTimStart": "2013-07-13T06:00:00+02:00", "md": "4420", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to correlate gun position for perforation interval # 3. Lost communication with perforation BHA # 3.", "dTimEnd": "2013-07-13T12:15:00+02:00", "dTimStart": "2013-07-13T11:15:00+02:00", "md": "4420", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH to surface. Closed-in well and inflow tested same. bleed off wellhead pressure to 0 bar and broke out lubricator.", "dTimEnd": "2013-07-13T17:45:00+02:00", "dTimStart": "2013-07-13T12:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "L/D BHA on cantiliver deck and troubleshoot communication failure. Communication failure identified in cablehead.", "dTimEnd": "2013-07-13T20:15:00+02:00", "dTimStart": "2013-07-13T17:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Build new cablehead and tested tools.", "dTimEnd": "2013-07-13T23:00:00+02:00", "dTimStart": "2013-07-13T20:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "P/U and M/U perforation BHA # 3RR.", "dTimEnd": "2013-07-14T00:00:00+02:00", "dTimStart": "2013-07-13T23:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_B_2013_07_15
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-14T00:00:00+02:00
2013-07-15T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-15T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH with perforation BHA # 4. Correlate and position guns for perforation, lost communication. POOH.and L/O perforation assemnbly. Install new wireline wench and re-build caplehead. P/U and M/U perforation BHA # 4RR and RIH.\n", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "48", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with perforation BHA # 3RR. Correlated and positioned guns between 4355 m to 4367 m. Perforated interval # 3 and POOH.\nL/O perforation BHA # 3RR and re-buil cablehead. P/U and M/U perforation BHA # 4 and RIH to 3825 m", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "M/U lubricator and tested In-Situ Sub to 30/200 bar for 5/10 min.", "dTimEnd": "2013-07-14T00:30:00+02:00", "dTimStart": "2013-07-14T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with perforation BHA # 3RR on wireline from surface to 3470 m. WHP 37 bar.\n(Tool length: 30.85m, MAX OD:4.5 in, Tool Weight: 1184.65 kg)", "dTimEnd": "2013-07-14T03:00:00+02:00", "dTimStart": "2013-07-14T00:30:00+02:00", "md": "3470", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with perforation BHA # 3RR on wireline tractor from 3470 m to 4450 m.", "dTimEnd": "2013-07-14T05:30:00+02:00", "dTimStart": "2013-07-14T03:00:00+02:00", "md": "4450", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Correlated across perforation interval # 3 and positioned guns.\nWHP: 39 bar", "dTimEnd": "2013-07-14T08:45:00+02:00", "dTimStart": "2013-07-14T05:30:00+02:00", "md": "4450", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Perforated interval # 3 from 4355 m to 4367 m. WHP stabilized at 39 bar.", "dTimEnd": "2013-07-14T09:00:00+02:00", "dTimStart": "2013-07-14T08:45:00+02:00", "md": "4367", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforation BHA # 3RR from 4367 m to surface.", "dTimEnd": "2013-07-14T12:15:00+02:00", "dTimStart": "2013-07-14T09:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. Closed-in well and inflow tested same. Bleed down pressure to 0 bar and broke out lubricator.", "dTimEnd": "2013-07-14T13:45:00+02:00", "dTimStart": "2013-07-14T12:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/O perforation BHA # 3RR.", "dTimEnd": "2013-07-14T15:30:00+02:00", "dTimStart": "2013-07-14T13:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Re-build cablehead and tested tools.", "dTimEnd": "2013-07-14T18:00:00+02:00", "dTimStart": "2013-07-14T15:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. P/U and M/U perforation BHA # 4\n(Tool length: 27.01m, MAX OD: 4.5in, Tool Weight: 974.65 kg)", "dTimEnd": "2013-07-14T20:00:00+02:00", "dTimStart": "2013-07-14T18:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U lubricator and pressure tested In-Situ Sub to 30/200 bar for 5/10 min. Eqaulized pressure and opened well.", "dTimEnd": "2013-07-14T20:30:00+02:00", "dTimStart": "2013-07-14T20:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 4 on wireline from surface to 3390 m. WHP 42 bar", "dTimEnd": "2013-07-14T23:00:00+02:00", "dTimStart": "2013-07-14T20:30:00+02:00", "md": "3390", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 4 on wireline tractor from 3390 m to 3825 m.", "dTimEnd": "2013-07-15T00:00:00+02:00", "dTimStart": "2013-07-14T23:00:00+02:00", "md": "3825", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_16
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-15T00:00:00+02:00
2013-07-16T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-16T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "M/U lubricator and test In-Situ Sub. RIH to correlation depth. Correlate and position guns. Perforate interval # 4.\nPOOH and L/O BHA # 4RR. P/U and M/U perforation BHA # 5.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "49", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with perforation BHA # 4 to 4470 m. Lost communication to tools. POOH with perforation BHA # 4 and L/O same. L/D lubricator and changed out wireline wench. Installed back-up wench and test wireline package, No Go. slipped and cut 800 m wireline caple and tested wireline. P/U and M/U perforation BHA # 4RR.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "RIH with perforation BHA # 4 on wireline tractor from 3825 m to 4470 m.", "dTimEnd": "2013-07-15T01:30:00+02:00", "dTimStart": "2013-07-15T00:00:00+02:00", "md": "4470", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to correlate across interval # 4 from 4470 m. Lost communication with tool string at 4450 m.", "dTimEnd": "2013-07-15T01:45:00+02:00", "dTimStart": "2013-07-15T01:30:00+02:00", "md": "4450", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforation BHA # 4 on wireline from 4450 m to surface. WHP 42 bar.", "dTimEnd": "2013-07-15T05:30:00+02:00", "dTimStart": "2013-07-15T01:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Closed-in well and inflow tested same. Bleed down pressure to 0 bar.", "dTimEnd": "2013-07-15T06:30:00+02:00", "dTimStart": "2013-07-15T05:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Broke out lubrictor and L/O tools.\nWireline logging computer blacked out at 07:30 hrs.", "dTimEnd": "2013-07-15T08:45:00+02:00", "dTimStart": "2013-07-15T06:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Cut wireline and L/D lubricator. R/D wireline wench and prepared to R/U back-up wench.", "dTimEnd": "2013-07-15T11:45:00+02:00", "dTimStart": "2013-07-15T08:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Spudded back-up wench on cantilever.", "dTimEnd": "2013-07-15T12:00:00+02:00", "dTimStart": "2013-07-15T11:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Hooked-up and tested wireline unit.\nInstalled new logging computer.", "dTimEnd": "2013-07-15T15:30:00+02:00", "dTimStart": "2013-07-15T12:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Attempted to test wireline caple, No Go. Slipped and cut 200m sections untill good test. Slipped and cut 800 m wireline and achieved good test.", "dTimEnd": "2013-07-15T18:00:00+02:00", "dTimStart": "2013-07-15T15:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Build cablehead and P/U lubricator.", "dTimEnd": "2013-07-15T20:30:00+02:00", "dTimStart": "2013-07-15T18:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "P/U and M/U wireline tractor to cablehead. Tested tractor communication and M/U lubricator.\n", "dTimEnd": "2013-07-15T22:15:00+02:00", "dTimStart": "2013-07-15T20:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Pressure tested In-situ sub to 30/200 bar, 5/10 min. Displaced lubricator and pressure tested same to 30/345 bar for 5/10 min.", "dTimEnd": "2013-07-15T23:30:00+02:00", "dTimStart": "2013-07-15T22:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Bleed off pressure and broke out lubricator. P/U and M/U perforation BHA # 4RR.", "dTimEnd": "2013-07-16T00:00:00+02:00", "dTimStart": "2013-07-15T23:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_B_2013_07_17
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-16T00:00:00+02:00
2013-07-17T00:00:00+02:00
normal
2018-05-03T13:51:38+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-17T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH with perforation BHA # 4RR2, No Go. POOH and L/O perforation BHA # 4RR2. P/U and M/U perforation BHA # 4RR3. RIH with perforation BHA # 4RR3.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "50", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "P/U and M/U perforation BHA # 4RR1. RIH from surface to 3670 m. Worked assembly from 3670 m to 3921 m. Unable to pass 3921 m.\nPOOH and L/O perforation BHA 4RR1. Changed out greasehead on wireline and RIH with perforation BHA # 4RR2 to 500 m.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "P/U and M/U perforation BHA # 4RR. M/U lubricator and tested In-situ Sub to 30/300 bar for 5/10 min.\n(Tool length: 30.85m, MAX OD:4.5 in, Tool Weight: 1184.65 kg)", "dTimEnd": "2013-07-16T01:00:00+02:00", "dTimStart": "2013-07-16T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with perforation BHA # 4RR on wireline from surface to 3400 m. WHP 47 bar", "dTimEnd": "2013-07-16T03:45:00+02:00", "dTimStart": "2013-07-16T01:00:00+02:00", "md": "3400", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with perforation BHA # 4RR on wireline tractor from 3400 m to 3670 m.", "dTimEnd": "2013-07-16T04:30:00+02:00", "dTimStart": "2013-07-16T03:45:00+02:00", "md": "3670", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Worked assembly from 3670 m to 3921 m. Unable to pass 3921 m.", "dTimEnd": "2013-07-16T10:00:00+02:00", "dTimStart": "2013-07-16T04:30:00+02:00", "md": "3921", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "POOH from 3921 m to surface.", "dTimEnd": "2013-07-16T12:30:00+02:00", "dTimStart": "2013-07-16T10:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Closed and inflow tested well. Broke lubricator and L/O BHA # 4RR.", "dTimEnd": "2013-07-16T15:45:00+02:00", "dTimStart": "2013-07-16T12:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "L/D lubricator and changed greasehead. R/U wireline, build caplehead and tested tools.", "dTimEnd": "2013-07-16T20:15:00+02:00", "dTimStart": "2013-07-16T15:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "P/U and M/U wireline tractor and lubricator. Pressure tested In-Situ Sub to 30/300 bar for 5/10 min and Lubricator to 30/345 bar for 5/10 min.", "dTimEnd": "2013-07-16T22:00:00+02:00", "dTimStart": "2013-07-16T20:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Broke out lubricator. P/U perforation guns and M/U perforation BHA # 4RR2", "dTimEnd": "2013-07-16T22:30:00+02:00", "dTimStart": "2013-07-16T22:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "M/U lubricator and tested In-Situ Sub to 30/300 bar for 5/10 min. Eqaulized pressure and opened well.", "dTimEnd": "2013-07-16T23:00:00+02:00", "dTimStart": "2013-07-16T22:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH perforation BHA # 4RR2 from surface to 500 m.", "dTimEnd": "2013-07-17T00:00:00+02:00", "dTimStart": "2013-07-16T23:00:00+02:00", "md": "500", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_B_2013_07_18
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-17T00:00:00+02:00
2013-07-18T00:00:00+02:00
normal
2018-05-03T13:51:39+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-18T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "L/O perforation BHA # 4RR3 and build new cablehaed. P/U and M/U perforation BHA # 5 and RIH to correlation depth. Correlate and position gun assembly. Perforate interval # 5. POOH to surface.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "51", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with perforation BHA # 4RR2. Attempted to correlate and position gun assembly, No Go. POOH with perforation BHA # 4RR2 to surface and L/O same. Changed out VPM-g, PTA, cablehead and tractor. P/U and M/U perforation BHA # 4RR3. RIH and positioned gun assembly. Perforated interval # 4 from 4304 m to 4316 m and POOH to surface.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "RIH with perforation BHA # 4RR2 on wireline from 500 m to 3332 m. Attempted to function Voltage Protection Module to engage tractor, No Go.", "dTimEnd": "2013-07-17T01:45:00+02:00", "dTimStart": "2013-07-17T00:00:00+02:00", "md": "3332", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Attempted to troubleshoot communication failure, No Go.", "dTimEnd": "2013-07-17T03:00:00+02:00", "dTimStart": "2013-07-17T01:45:00+02:00", "md": "3332", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "POOH with perforation BHA # 4RR2 on wireline from 3332 m to surface.", "dTimEnd": "2013-07-17T05:30:00+02:00", "dTimStart": "2013-07-17T03:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Closed and inflow tested Swab and Hydraulic master valves with 46 bar differential pressure. Broke out lubricator and L/O tools.", "dTimEnd": "2013-07-17T08:00:00+02:00", "dTimStart": "2013-07-17T05:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Troubleshoot tool failure. Build new cablehead and changed out Voltage Protection Moule, Power Track Advanced, swivel and tractor", "dTimEnd": "2013-07-17T11:00:00+02:00", "dTimStart": "2013-07-17T08:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "P/U tractor assembly and lubricator. M/U lubricator and tested tools. Eqaulized pressure and opened well. \n(Tool length: 30.85m, MAX OD:4.5 in, Tool Weight: 1184.65 kg)\nWHP: 51 bar", "dTimEnd": "2013-07-17T13:15:00+02:00", "dTimStart": "2013-07-17T11:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with perforation BHA # 4RR3 on wireline from surface to 3350 m.\nTools tested at 250 m.", "dTimEnd": "2013-07-17T16:00:00+02:00", "dTimStart": "2013-07-17T13:15:00+02:00", "md": "3350", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH with perforation BHA # 4RR3 on wireline tractor from 3350 m to 4040 m.", "dTimEnd": "2013-07-17T19:00:00+02:00", "dTimStart": "2013-07-17T16:00:00+02:00", "md": "4040", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Correlated and positioned gun assembly at perforation interval # 4 from 4304 m to 4316 m. WHP 51 bar", "dTimEnd": "2013-07-17T20:15:00+02:00", "dTimStart": "2013-07-17T19:00:00+02:00", "md": "4316", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Perforated interval # 4 from 4304 m to 4316 m, good indication of guns fired.\n51 bar WHP before and after perforation.", "dTimEnd": "2013-07-17T20:30:00+02:00", "dTimStart": "2013-07-17T20:15:00+02:00", "md": "4316", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforation BHA # 4RR3 from 4316 m to surface. WHP 52 bar", "dTimEnd": "2013-07-17T23:15:00+02:00", "dTimStart": "2013-07-17T20:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed and inflow tested Swab and Hydraulic master valves with 47 bar differential pressure.", "dTimEnd": "2013-07-18T00:00:00+02:00", "dTimStart": "2013-07-17T23:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_19
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-18T00:00:00+02:00
2013-07-19T00:00:00+02:00
normal
2018-05-03T13:51:39+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-19T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "M/U perforation BHA # 6. RIH from surface to 4300m. Correlate and position gun assembly. Perforate interval # 6 and POOH to surface. L/O perforation BHA # 6 and P/U BHA # 7.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "52", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "L/O perforation BHA # 4RR3. P/U and M/U perforation BHA # 5. RIH and perforated interval # 5. POOH from 4295 m to surface with perforation BHA # 5 and L/O same.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Bleed down pressure to 0 bar and broke out lubricator.", "dTimEnd": "2013-07-18T00:30:00+02:00", "dTimStart": "2013-07-18T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/O perforation BHA # 4RR3 and L/D lubricator", "dTimEnd": "2013-07-18T02:00:00+02:00", "dTimStart": "2013-07-18T00:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Re-build cablehead and tested tools.\nMeanwhile removed topdrive pipe handler for service.", "dTimEnd": "2013-07-18T05:00:00+02:00", "dTimStart": "2013-07-18T02:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U lubricator and M/U perforation BHA # 5.", "dTimEnd": "2013-07-18T07:15:00+02:00", "dTimStart": "2013-07-18T05:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U lubricator and pressure tested In-Situ Sub to 30/300 bar for 5/10 min. Eqaulized pressure and opened well.", "dTimEnd": "2013-07-18T08:00:00+02:00", "dTimStart": "2013-07-18T07:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 5 on wireline from surface to 3377 m.\n(Tool length: 27.01m, MAX OD: 4.5in, Tool Weight: 974.65 kg)", "dTimEnd": "2013-07-18T10:30:00+02:00", "dTimStart": "2013-07-18T08:00:00+02:00", "md": "3377", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 5 on wireline tractor from 3377 m to 4305 m.", "dTimEnd": "2013-07-18T12:30:00+02:00", "dTimStart": "2013-07-18T10:30:00+02:00", "md": "4305", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated and postioned gun assembly at perforation interval # 5 from 4295 m to 4286 m.\nWHP: 53.6 bar before and after perforation", "dTimEnd": "2013-07-18T14:15:00+02:00", "dTimStart": "2013-07-18T12:30:00+02:00", "md": "4295", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Perforated interval # 5, good indication of guns fired.", "dTimEnd": "2013-07-18T14:30:00+02:00", "dTimStart": "2013-07-18T14:15:00+02:00", "md": "4295", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforation BHA # 5 from 4295 m to surface.", "dTimEnd": "2013-07-18T17:30:00+02:00", "dTimStart": "2013-07-18T14:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed and inflow tested HMV/SWAB valve. Broke out lubricator and L/O perforation BHA # 5.", "dTimEnd": "2013-07-18T20:45:00+02:00", "dTimStart": "2013-07-18T17:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Re-biuld cablehead and tested tools.\nMeanwhile: Removed washpipe and checked bolts on topdrive main chaft bearing retainer.", "dTimEnd": "2013-07-18T23:15:00+02:00", "dTimStart": "2013-07-18T20:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U lubricator and perforation BHA # 6.", "dTimEnd": "2013-07-19T00:00:00+02:00", "dTimStart": "2013-07-18T23:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_20
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-19T00:00:00+02:00
2013-07-20T00:00:00+02:00
normal
2018-05-03T13:51:39+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-20T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH and position perforation BHA # 7. Perforate interval # 7 and POOH. L/O BHA # 7 and P/U perforation BHA # 8. RIH and Position gun assembly at interval # 8 from 4031 m to 4043 m.", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "53", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with perforation BHA # 6 and positioned gun assembly at interval # 6 from 4268 m to 4280 m. Perforated interval # 6 and POOH. L/O perforation BHA # 6 and re-build cablehead. P/U and M/U perforation BHA # 7. RIH with perforation BHA # 7 to 3693 m.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "M/U perforation BHA # 6.", "dTimEnd": "2013-07-19T02:00:00+02:00", "dTimStart": "2013-07-19T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U lubricator and pressure tested In-Situ Sub to 30/300 bar for 5/10 min. Eqaulized pressure and opened well. WHP 55 bar.", "dTimEnd": "2013-07-19T03:00:00+02:00", "dTimStart": "2013-07-19T02:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 6 on wireline from surface to 3400 m\n(Tool length: 30.85m, MAX OD:4.5 in, Tool Weight: 1184.65 kg)\nWHP: 56 bar", "dTimEnd": "2013-07-19T05:45:00+02:00", "dTimStart": "2013-07-19T03:00:00+02:00", "md": "3400", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 6 on wireline tractor from 3400 m to 4325 m.", "dTimEnd": "2013-07-19T08:15:00+02:00", "dTimStart": "2013-07-19T05:45:00+02:00", "md": "4325", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated across interval # 6 from 4280 m to 4268 m and positioned guns.", "dTimEnd": "2013-07-19T10:00:00+02:00", "dTimStart": "2013-07-19T08:15:00+02:00", "md": "4280", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Perforated interval # 6 from 4268 m to 4280 m, good indication of guns fired.", "dTimEnd": "2013-07-19T10:15:00+02:00", "dTimStart": "2013-07-19T10:00:00+02:00", "md": "4280", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforation BHA # 6 from 4280 m to surface. WHP 56 bar.", "dTimEnd": "2013-07-19T13:30:00+02:00", "dTimStart": "2013-07-19T10:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed and inflow tested HMV/SWAB valve with 51 bar differential pressure.", "dTimEnd": "2013-07-19T14:00:00+02:00", "dTimStart": "2013-07-19T13:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke out lubricator and L/O perforation BHA # 6.", "dTimEnd": "2013-07-19T16:15:00+02:00", "dTimStart": "2013-07-19T14:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Re-build cablehead and tested tools prior to P/U perforation BHA # 7.", "dTimEnd": "2013-07-19T18:30:00+02:00", "dTimStart": "2013-07-19T16:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U perforation BHA # 7", "dTimEnd": "2013-07-19T20:30:00+02:00", "dTimStart": "2013-07-19T18:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U lubricator and pressure tested In-Situ Sub to 30/300 bar for 5/10 min.", "dTimEnd": "2013-07-19T21:00:00+02:00", "dTimStart": "2013-07-19T20:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 7 on wireline from surface to 3529 m.", "dTimEnd": "2013-07-19T23:30:00+02:00", "dTimStart": "2013-07-19T21:00:00+02:00", "md": "3529", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 7 on wireline tractor from 3529 m to 3693 m.", "dTimEnd": "2013-07-20T00:00:00+02:00", "dTimStart": "2013-07-19T23:30:00+02:00", "md": "3693", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_21
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-20T00:00:00+02:00
2013-07-21T00:00:00+02:00
normal
2018-05-03T13:51:39+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-21T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Inflow test HMV and SCSSSV. L/O perforation BHA # 8 and R/D wireline equipment", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "54", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "RIH with perforation BHA # 7. Postioned guns and perforated interval # 7. POOH and L/O perforation BHA # 7. P/U and RIH perforation BHA # 8. Positioned perforation BHA # 8 and perforated interval # 8. POOH to surface perforation BHA # 8.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "RIH with perforation BHA # 7 on wireline tractor from 3693 m to 4130 m", "dTimEnd": "2013-07-20T01:00:00+02:00", "dTimStart": "2013-07-20T00:00:00+02:00", "md": "4130", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated and positioned gun assembly at perforation interval # 7 from 4075 m to 4065 m. WHP 57.5 bar", "dTimEnd": "2013-07-20T03:45:00+02:00", "dTimStart": "2013-07-20T01:00:00+02:00", "md": "4075", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Perforated interval # 7, good indication of guns fired. WHP 58.1 bar\n (Tool length: 30.85m, MAX OD:4.5 in, Tool Weight: 1184.65 kg)", "dTimEnd": "2013-07-20T04:00:00+02:00", "dTimStart": "2013-07-20T03:45:00+02:00", "md": "4075", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforation BHA # 7 from 4075 m to Surface. WHP 59 bar.", "dTimEnd": "2013-07-20T07:15:00+02:00", "dTimStart": "2013-07-20T04:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed and inflow tested HMV/SWAB valve with 54 bar differential pressure.", "dTimEnd": "2013-07-20T08:45:00+02:00", "dTimStart": "2013-07-20T07:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke out lubricator and L/O perforation BHA # 7.", "dTimEnd": "2013-07-20T10:30:00+02:00", "dTimStart": "2013-07-20T08:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Re-build cablehead and tested tools.", "dTimEnd": "2013-07-20T11:30:00+02:00", "dTimStart": "2013-07-20T10:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U perforation BHA # 8.", "dTimEnd": "2013-07-20T13:30:00+02:00", "dTimStart": "2013-07-20T11:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U lubricator and pressure tested In-Situ Sub to 30/300 bar for 5/10 min. Eqaulized pressure and opened well. WHP 59 bar.", "dTimEnd": "2013-07-20T14:30:00+02:00", "dTimStart": "2013-07-20T13:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with perforation BHA # 8 from surface to 4095 m", "dTimEnd": "2013-07-20T19:00:00+02:00", "dTimStart": "2013-07-20T14:30:00+02:00", "md": "4095", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated and positioned gun assembly at perforation interval # 8.", "dTimEnd": "2013-07-20T20:15:00+02:00", "dTimStart": "2013-07-20T19:00:00+02:00", "md": "4043", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Perforated interval # 8 from 4043 m to 4031 m.", "dTimEnd": "2013-07-20T20:30:00+02:00", "dTimStart": "2013-07-20T20:15:00+02:00", "md": "4043", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with perforation BHA # 8 from 4043 m to surface. WHP 59 bar.", "dTimEnd": "2013-07-21T00:00:00+02:00", "dTimStart": "2013-07-20T20:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_22
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-21T00:00:00+02:00
2013-07-22T00:00:00+02:00
normal
2018-05-03T13:51:39+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-22T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-09T00:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "None", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "55", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Inflow tested SCSSSV and HMV. R/D wireline equipment and prepared for skidding operations..", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Inflow tested surface controlled subsea safety valve for 30 min and hydraulic master valve for 10 min with 56 bar differential.", "dTimEnd": "2013-07-21T01:45:00+02:00", "dTimStart": "2013-07-21T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Purged riser and lubricator. B/O lubricator and L/O perforation BHA # 8.", "dTimEnd": "2013-07-21T04:15:00+02:00", "dTimStart": "2013-07-21T01:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/D wireline equipment.", "dTimEnd": "2013-07-21T10:30:00+02:00", "dTimStart": "2013-07-21T04:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "completion -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Prepared for skidding operation:\nInstalled weather deck hatches on slot F-11.\nInstalled drilling hatches on slot F-1\nR/D Enviro Unit hand rails and moved same 3 m port.\nPerformed deck manegement in preparation of equipment for 26\" section.\nPerformed maintenance of drilling equipment.\nSpudded Gyro wireline equipment on cantiliver deck.\nL/O 26\" mud motor BHA on cantiliver.\n\n******* Reporting transfered to F-1 *********", "dTimEnd": "2013-07-21T23:00:00+02:00", "dTimStart": "2013-07-21T10:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_23
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-22T00:00:00+02:00
2013-07-23T00:00:00+02:00
normal
2018-05-03T13:51:39+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-23T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-22T14:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "None", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "56", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Performed pressure testing of valves on F-11 Xmas tree in preparation for handover to production department.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Started reporting rig activity on F-1 at 23:00hrs on 21.07.2013\n\nPrepared for final pressure test on F-11B Xmas tree before handover to production department.\nPerformed testing on tree as follows:\n\n- Filled Xmas tree with MEG using MEG injection pump. Pressure tested tree cap to 30/200 bar for 5/10min, good test.\n- Pressure tested Swab valve to 30/200 bar for 5/10 mi, good test\n- Bullheaded 3 m3 MEG into tubing using MEG injection pump, followed by 6,6 m3 packer fluid using cement pump and 1,2 m3 MEG with MEG injection pump. Closed DHSV and inflow tested same for 30 min, good test.\n\nSuspended further testing on F-11 tree until F-1 26\" section below DHSV \n", "dTimEnd": "2013-07-22T18:00:00+02:00", "dTimStart": "2013-07-22T14:00:00+02:00", "md": "4768.7", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2013_07_24
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2013-07-23T00:00:00+02:00
2013-07-24T00:00:00+02:00
normal
2018-05-03T13:51:39+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-07-24T00:00:00+02:00", "dTimDiaHoleStart": "2013-07-22T14:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "None", "hpht": "0", "md": "4770", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "57", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Performed final pressure testing on F-11B tree and handed well over to production.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued offline pressure test operations on F-11 Xmas tree for handover to production department.\n\n- Inflow tested HMV for 10 min, good test.\n- Inflow tested MMV for 10 min, good test.\n- Installed 2\" weco blind cap on KWV.\n- Pressured tested Xmas tree KWV cap and KWV to 35/200 bar for 5/10 min, good test.\n\nWell F-11B handed over to production 23.07.2013 at 20:00 hrs.", "dTimEnd": "2013-07-23T20:00:00+02:00", "dTimStart": "2013-07-23T17:00:00+02:00", "md": "4768.7", "phase": "fixed", "proprietaryCode": "completion -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_10_25
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-10-24T00:00:00+02:00
2015-10-25T00:00:00+02:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-10-25T00:00:00+02:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Continue spotting equipment and prepare for R/U on XMT.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "1", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Lifted wireline equipment off vessel and started to spot same.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Vessel arrived rig. Unloaded WL equipment from vessel.", "dTimEnd": "2015-10-25T00:00:00+02:00", "dTimStart": "2015-10-24T21:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_10_26
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-10-25T00:00:00+02:00
2015-10-26T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-10-26T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Recieve well from production. Rig up WL equipment.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "2", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Spotted wireline equipment and hooked up same. Leak and function tested BOP. Started to build lubricator sections and GIH. ", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued to lift containers from vessel.", "dTimEnd": "2015-10-25T03:00:00+01:00", "dTimStart": "2015-10-25T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Spotted equipment on pipedeck according to spotting plan. Started to hook up units to power.\nMeanwhile spotted containers on drill floor.", "dTimEnd": "2015-10-25T06:00:00+01:00", "dTimStart": "2015-10-25T03:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Prepared cables for hookup of the general surface equipment.", "dTimEnd": "2015-10-25T07:30:00+01:00", "dTimStart": "2015-10-25T06:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held platform general alarm exercise with all crew.", "dTimEnd": "2015-10-25T08:00:00+01:00", "dTimStart": "2015-10-25T07:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up general surface equipment; WL winch and add on, Altus and Schlumberger logging units, working containers etc. Built scaffolding around units.", "dTimEnd": "2015-10-25T16:00:00+01:00", "dTimStart": "2015-10-25T08:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Leak tested BOP to 20/345 bar for 5/10 min on stump.", "dTimEnd": "2015-10-25T18:00:00+01:00", "dTimStart": "2015-10-25T16:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Function tested BOP rams from winch panel.", "dTimEnd": "2015-10-25T20:00:00+01:00", "dTimStart": "2015-10-25T18:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Finalized WL winch and function tested same.", "dTimEnd": "2015-10-25T20:30:00+01:00", "dTimStart": "2015-10-25T20:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted riser pieces to drill floor prior to start building lower riser section and lubricator. Lifted grease injection head, GIH, and prepared same.\nMeanwhile Altus and Schlumberger started to prepare BHA for testing.", "dTimEnd": "2015-10-25T22:00:00+01:00", "dTimStart": "2015-10-25T20:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Built lubricator horizontally using tugger and catwalk.\nMeanwhile built GIH.", "dTimEnd": "2015-10-26T00:00:00+01:00", "dTimStart": "2015-10-25T22:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_10_27
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-10-26T00:00:00+01:00
2015-10-27T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-10-27T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run in hole to perform PLT/RST logging.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "3", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Completed spotting equipment. Well handed over from production department. Rigged up wireline equipment.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued to build lubricator and installed same in elevator connected to top drive. Built lower riser section and top lubricator.\nMeanwhile production department started to close in well.", "dTimEnd": "2015-10-26T02:00:00+01:00", "dTimStart": "2015-10-26T00:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Spotted BOP in moonpool area. Connected GIH to top lubricator and treaded cable.", "dTimEnd": "2015-10-26T03:30:00+01:00", "dTimStart": "2015-10-26T02:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Hooked up airhose to line viper.\nMeanwhile Altus megged cable and built cablehead.", "dTimEnd": "2015-10-26T04:30:00+01:00", "dTimStart": "2015-10-26T03:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Spooled out hoses for BOP, test pump and hoses for HMV & DHSV down to moonpool. \nMeanwhile Altus megged cablehead and function tested tractor.", "dTimEnd": "2015-10-26T06:00:00+01:00", "dTimStart": "2015-10-26T04:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Connected hoses to grease injection head.", "dTimEnd": "2015-10-26T07:00:00+01:00", "dTimStart": "2015-10-26T06:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on production to complete shutting inn and inflow test well.\nMeanwhile performed toolbox talk for changing hatch and rigging up. Altus and Schlumberger tested toolstring.", "dTimEnd": "2015-10-26T11:00:00+01:00", "dTimStart": "2015-10-26T07:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Received well from production department.", "dTimEnd": "2015-10-26T11:30:00+01:00", "dTimStart": "2015-10-26T11:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed well hatch with wireline hatch.", "dTimEnd": "2015-10-26T12:30:00+01:00", "dTimStart": "2015-10-26T11:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected top cap and landed lower riser and BOP. Hooked up hoses and function tested same.\nMeanwhile Altus and Schlumberger completed string test.", "dTimEnd": "2015-10-26T15:00:00+01:00", "dTimStart": "2015-10-26T12:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up kill wing manifold, bleedoff hose and equalizing loop over to prod. wing.", "dTimEnd": "2015-10-26T19:00:00+01:00", "dTimStart": "2015-10-26T15:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Filled oil on pump for DHSV & HMV and prepared same, had some issue with air into system.", "dTimEnd": "2015-10-26T20:30:00+01:00", "dTimStart": "2015-10-26T19:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up via BOP for inflow test / Leak test of swab and kill wing manifold.", "dTimEnd": "2015-10-26T22:00:00+01:00", "dTimStart": "2015-10-26T20:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting for testing swab and Kill wing manifold.", "dTimEnd": "2015-10-26T22:15:00+01:00", "dTimStart": "2015-10-26T22:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Inflow tested / leak tested swab to 20/345 bar for 5/10 min according to program. Leak tested kill wing manifold and hoses to 20/345 bar for 5/10 min.", "dTimEnd": "2015-10-27T00:00:00+01:00", "dTimStart": "2015-10-26T22:15:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_10_28
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-10-27T00:00:00+01:00
2015-10-28T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-10-28T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Log RST IC pass.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "4", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Completed rigging up WL equipment. Leak tested R/U to 20/345 bar. Logged first sigma pass from 4530 m to 3440 m. Started to log first IC pass from 4254 m.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Hooked up hoses for local control of DHSV and HMV and tested same.", "dTimEnd": "2015-10-27T01:15:00+01:00", "dTimStart": "2015-10-27T00:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre job meeting prior to install lubricator sections.", "dTimEnd": "2015-10-27T01:30:00+01:00", "dTimStart": "2015-10-27T01:15:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted middle lubricator section and connected same to BOP. Lifted top lubricator.", "dTimEnd": "2015-10-27T02:00:00+01:00", "dTimStart": "2015-10-27T01:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U BHA #1 Tractor and PLT/RST and installed same.", "dTimEnd": "2015-10-27T04:30:00+01:00", "dTimStart": "2015-10-27T02:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Stabbed lubricator and filled rig up with MEG using production permanent lines via XMT cross. Leak tested R/U to 20/345 bar for 5/10 min.\nMeanwhile performed communication check with tools.", "dTimEnd": "2015-10-27T06:15:00+01:00", "dTimStart": "2015-10-27T04:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened HMV. Pressurized DHSV control line. Production pumped MEG via XMT cross to equalize across DHSV and opened same.", "dTimEnd": "2015-10-27T07:45:00+01:00", "dTimStart": "2015-10-27T06:15:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Equalized pressure across swab and opened same.", "dTimEnd": "2015-10-27T08:45:00+01:00", "dTimStart": "2015-10-27T07:45:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ BHA #1 (Tractor & PLT/RST) by gravity from surface to 540 m, WHP 94 bar.", "dTimEnd": "2015-10-27T09:30:00+01:00", "dTimStart": "2015-10-27T08:45:00+01:00", "md": "540", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Schlumberger performed communication check with toolstring.", "dTimEnd": "2015-10-27T10:00:00+01:00", "dTimStart": "2015-10-27T09:30:00+01:00", "md": "540", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to RIH by gravity from 540 m to 2750 m. Stopped for spinner calibration.\nDepth PU\n400 m 1150 lbs\n800 m 1350 lbs\n1200 m 2000 lbs\n1600 m 2300 lbs\n2000 m 2950 lbs\n2400 m 3450 lbs\nFF at 0,3 or slightly below", "dTimEnd": "2015-10-27T11:45:00+01:00", "dTimStart": "2015-10-27T10:00:00+01:00", "md": "2750", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed spinner calibration at 10, 20, 30 & 40 m/min.\nMeanwhile performed well control drill.", "dTimEnd": "2015-10-27T12:30:00+01:00", "dTimStart": "2015-10-27T11:45:00+01:00", "md": "2750", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to RIH by gravity. Observed tool stopped at 2800 m. PU weight 3850 lbs. Had to start tractor.", "dTimEnd": "2015-10-27T12:45:00+01:00", "dTimStart": "2015-10-27T12:30:00+01:00", "md": "2800", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor mode.", "dTimEnd": "2015-10-27T13:00:00+01:00", "dTimStart": "2015-10-27T12:45:00+01:00", "md": "2800", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH using tractor from 2800 m to 3570 m. Tractor software froze.", "dTimEnd": "2015-10-27T14:35:00+01:00", "dTimStart": "2015-10-27T13:00:00+01:00", "md": "3570", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Restarted tractor software, OK.", "dTimEnd": "2015-10-27T15:05:00+01:00", "dTimStart": "2015-10-27T14:35:00+01:00", "md": "3570", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to RIH using tractor from 3570 m to 4530 m. Stopped to perform first sigma logging pass.\nDepth PU\n3200 m 4200 lbs\n3600 m 4150 lbs\n4000 m 4800 lbs\n4500 m 6100 lbs\nFF at 0,3 or slightly below", "dTimEnd": "2015-10-27T17:25:00+01:00", "dTimStart": "2015-10-27T15:05:00+01:00", "md": "4530", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Powered up minitron and started 10 m/min up pass. Logged sigma across 4530 to 3430 m.", "dTimEnd": "2015-10-27T19:40:00+01:00", "dTimStart": "2015-10-27T17:25:00+01:00", "md": "3440", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor mode and tractored back down from 3440 m to 4270 m.", "dTimEnd": "2015-10-27T21:30:00+01:00", "dTimStart": "2015-10-27T19:40:00+01:00", "md": "4270", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Powered up RST tool to perform first IC up pass at 0,5 m/min. Logged across interval 4254 to 4200 m. WHP 102 bar.", "dTimEnd": "2015-10-28T00:00:00+01:00", "dTimStart": "2015-10-27T21:30:00+01:00", "md": "4200", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_10_29
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-10-28T00:00:00+01:00
2015-10-29T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-10-29T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Continue to log RST or bean up well to perform PLT logging.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "5", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Completed first set of RST IC logging passes from 4254 to 3470 m. Started second set of RST IC logging passes in same intervals.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued to log RST IC pass at 0,5 m/min across interval from 4200 to 4188 m, 4045 to 3895 m and 3827 up to 3818 m. \nMeanwhile performed well control drill.", "dTimEnd": "2015-10-28T06:00:00+01:00", "dTimStart": "2015-10-28T00:00:00+01:00", "md": "3818", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to log IC pass at 0,5 m/min from 3818 to 3660 m and 3522 to 3470 m. Completed logging first IC pass.", "dTimEnd": "2015-10-28T13:10:00+01:00", "dTimStart": "2015-10-28T06:00:00+01:00", "md": "3470", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor and tractored down from 3470 m to 4270 m.", "dTimEnd": "2015-10-28T15:05:00+01:00", "dTimStart": "2015-10-28T13:10:00+01:00", "md": "4270", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to logging mode and started second IC pass. Logged IC pass at 0,5 m/min from 4254 to 4188 m, 4045 to 3895 m and 3827 to 3780 m. WHP 109.", "dTimEnd": "2015-10-29T00:00:00+01:00", "dTimStart": "2015-10-28T15:05:00+01:00", "md": "3780", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_10_30
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-10-29T00:00:00+01:00
2015-10-30T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-10-30T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Perform flowing PLT passes.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "6", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Completed logging RST IC passes. Performed shut in PLT pass. Started to bean up well for flowing PLT passes.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued to log RST IC pass at 0,5 m/min from 3780 to 3660 and 3522 to 3470 m. Completed logging second IC pass.", "dTimEnd": "2015-10-29T06:00:00+01:00", "dTimStart": "2015-10-29T00:00:00+01:00", "md": "3470", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor and tractored back down to 4525 m to perform PLT shut in pass.", "dTimEnd": "2015-10-29T08:25:00+01:00", "dTimStart": "2015-10-29T06:00:00+01:00", "md": "4525", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to logging mode and performed shut in PLT pass at 20 m/min across interval 4520 to 4000 m. Parked toolstring at 3994 m.", "dTimEnd": "2015-10-29T08:50:00+01:00", "dTimStart": "2015-10-29T08:25:00+01:00", "md": "3994", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Petec evaluated data. RST data was good. Challenging to evaluate PLT shut in passes. Had to re-arrange wells prior to startup F-11 B for production. Production ready to open well.", "dTimEnd": "2015-10-29T14:15:00+01:00", "dTimStart": "2015-10-29T08:50:00+01:00", "md": "3994", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Equalized pressure PWV using equalizing loop. Well routed towards HP separator. \nOpened choke 6%. WHP 108 bar and DHPG 302 bar.", "dTimEnd": "2015-10-29T15:10:00+01:00", "dTimStart": "2015-10-29T14:15:00+01:00", "md": "3994", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened choke stepwise up to 12%. WHP 59 bar and DHPG 258 bar.", "dTimEnd": "2015-10-29T19:00:00+01:00", "dTimStart": "2015-10-29T15:10:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened choke stepwise up to 20%. WHP 46 bar and DHPG 239 bar. \nMeanwhile observed pressure in DHSV CL was at 520 bar.", "dTimEnd": "2015-10-29T22:00:00+01:00", "dTimStart": "2015-10-29T19:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened choke stepwise up to 24%. WHP 43 bar and DHPG 235 bar.\nMeanwhile Isolated DHSV CL on wellhead and bled of pressure at pump to avoid bleeding off to 0 bar. Repeated sequence until CL pressure was 420 bar.", "dTimEnd": "2015-10-29T22:30:00+01:00", "dTimStart": "2015-10-29T22:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened choke stepwise up to 34%. WHP 38 bar and DHPG 227 bar.", "dTimEnd": "2015-10-30T00:00:00+01:00", "dTimStart": "2015-10-29T22:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_10_31
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-10-30T00:00:00+01:00
2015-10-31T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-10-31T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH with perforation guns. Correlate and perforate. POOH.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "7", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Logged three flowing PLT passes. Evaluated data and decided to perforate two new zones. POOH and L/D BHA. Started to prepare perforation gun.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Opened choke stepwise to 70 %. WHP 32 bar and DHPG 222 bar.", "dTimEnd": "2015-10-30T02:30:00+01:00", "dTimStart": "2015-10-30T00:00:00+01:00", "md": "3994", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened choke stepwise to 100 %. WHP 32 bar and DHPG 222 bar.", "dTimEnd": "2015-10-30T05:00:00+01:00", "dTimStart": "2015-10-30T02:30:00+01:00", "md": "3994", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor mode and RIH to perform 1. PLT flowing pass. Observed higher pullforce on tractor headtension 600 lbs compared to 300 lbs during shut in passes. Stopped at 4530 m.", "dTimEnd": "2015-10-30T06:35:00+01:00", "dTimStart": "2015-10-30T05:00:00+01:00", "md": "4530", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to logging mode and picked back up. Tension peaked at 9000 lbs (SLB counter) but decreased to approx. 6900 lbs. Logged PLT flowing pass at 10 m/min across interval 4520 m to 4000 m.", "dTimEnd": "2015-10-30T07:15:00+01:00", "dTimStart": "2015-10-30T06:35:00+01:00", "md": "3997", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor mode and RIH to perform 2. PLT flowing pass.", "dTimEnd": "2015-10-30T08:40:00+01:00", "dTimStart": "2015-10-30T07:15:00+01:00", "md": "4530", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to logging mode and picked back up. Logged PLT flowing pass at 20 m/min across interval 4520 m to 4000 m.", "dTimEnd": "2015-10-30T09:15:00+01:00", "dTimStart": "2015-10-30T08:40:00+01:00", "md": "3990", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor mode and RIH to perform 3. PLT flowing pass.", "dTimEnd": "2015-10-30T10:25:00+01:00", "dTimStart": "2015-10-30T09:15:00+01:00", "md": "4530", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to logging mode and picked back up. Logged PLT flowing pass at 30 m/min across interval 4520 m to 4000 m.", "dTimEnd": "2015-10-30T10:45:00+01:00", "dTimStart": "2015-10-30T10:25:00+01:00", "md": "3986", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "PETEC evaluated data from PLT flowing passes. Decision made to re-run one pass. Observed trouble to start tractor.", "dTimEnd": "2015-10-30T15:30:00+01:00", "dTimStart": "2015-10-30T10:45:00+01:00", "md": "3986", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Problem with tractor power supply. Had to change power supply on surface. OK.", "dTimEnd": "2015-10-30T16:45:00+01:00", "dTimStart": "2015-10-30T15:30:00+01:00", "md": "3986", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Decision made to not run the additional pass. PLT data was good enough for further decision. Shut in well and POOH. WHP 35 bar.", "dTimEnd": "2015-10-30T17:00:00+01:00", "dTimStart": "2015-10-30T16:45:00+01:00", "md": "3986", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 3986 m to surface. WHP 90 bar.", "dTimEnd": "2015-10-30T20:00:00+01:00", "dTimStart": "2015-10-30T17:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed SV and bled off lubricator. Inflow tested SV. Closed HMV and inflow tested same, monitored pressure in XMT cross. Meanwhile purged lubricator with N2 via bleed manifold.", "dTimEnd": "2015-10-30T21:40:00+01:00", "dTimStart": "2015-10-30T20:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed toolbox talk prior to L/D BHA#1.", "dTimEnd": "2015-10-30T21:50:00+01:00", "dTimStart": "2015-10-30T21:40:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator. L/D BHA #1 on deck.", "dTimEnd": "2015-10-30T23:30:00+01:00", "dTimStart": "2015-10-30T21:50:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Altus and Schlumberger strated to prepare toolstring for perforation run #1.", "dTimEnd": "2015-10-31T00:00:00+01:00", "dTimStart": "2015-10-30T23:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_11_01
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-10-31T00:00:00+01:00
2015-11-01T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-11-01T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Prepare next perforation gun. Install toolstring and RIH.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "8", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "M/U BHA #2 Tractor and 4,5\" perforating guns. RIH and performed correlation and orientation of the perforation gun. ", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Altus performed communication check with tools. Not able to communicate with Altus VPM through tractor.", "dTimEnd": "2015-10-31T02:00:00+01:00", "dTimStart": "2015-10-31T00:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Restarted all surface systems and changed to different VPM sub. Communication with VPM sub OK, but not able to switch same. Reviewed issue from last campaign, not similar issue.", "dTimEnd": "2015-10-31T03:30:00+01:00", "dTimStart": "2015-10-31T02:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Contacted onshore duty and continued to troubleshoot.", "dTimEnd": "2015-10-31T04:30:00+01:00", "dTimStart": "2015-10-31T03:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed the additional rig-grounding on the tool and switched VPM directly from the panel. VPM was switching OK. Issue most likely related to current grounding.", "dTimEnd": "2015-10-31T05:20:00+01:00", "dTimStart": "2015-10-31T04:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted tractor and assembled with Schlumberger toolstring to perform Schlumberger tool check.", "dTimEnd": "2015-10-31T06:00:00+01:00", "dTimStart": "2015-10-31T05:20:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted tools to rig floor due to wind picking up. Continued to check tools.", "dTimEnd": "2015-10-31T07:00:00+01:00", "dTimStart": "2015-10-31T06:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Powered down tools prior to handling explosives.", "dTimEnd": "2015-10-31T07:15:00+01:00", "dTimStart": "2015-10-31T07:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed toolbox talk prior to M/U BHA#2 tractor & perforation guns.", "dTimEnd": "2015-10-31T07:30:00+01:00", "dTimStart": "2015-10-31T07:15:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U BHA #2 Tractor and perforation gun. Added 40 litres of Starlube into lubricator. Challenging to handle heavy 4,5\" perforation gun. Leak tested QTS to 20/345 bar.", "dTimEnd": "2015-10-31T10:30:00+01:00", "dTimStart": "2015-10-31T07:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Filled lubricator with MEG using production permanent line into XMT cross. Equalized and opened HMV. Equalized and opened SV. WHP 118 bar.\nMeanwhile performed well control drill, leak in connection above BOP.", "dTimEnd": "2015-10-31T11:45:00+01:00", "dTimStart": "2015-10-31T10:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with BHA#2 Tractor and 4,5\" Perforation guns from surface to 70 m below seabed.", "dTimEnd": "2015-10-31T12:20:00+01:00", "dTimStart": "2015-10-31T11:45:00+01:00", "md": "210", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed communications check with tractor and tools.", "dTimEnd": "2015-10-31T12:30:00+01:00", "dTimStart": "2015-10-31T12:20:00+01:00", "md": "210", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to RIH from 210 m to 2800 m. Observed tool stopped. Had to start tractor.\nDepth PU (Altus winch)\n400 m 2070 lbs\n800 m 2630 lbs\n1200 m 3100 lbs \n1600 m 3800 lbs \n2000 m 4150 lbs \n2400 m 5050 lbs \n2800 m 6000 lbs", "dTimEnd": "2015-10-31T14:15:00+01:00", "dTimStart": "2015-10-31T12:30:00+01:00", "md": "2800", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor. Tractored down from 2800 m to 4030 m. Observed tractor speed decreased to approx. 2-3 m/min.\nDepth PU (Altus winch)\n3200 m 7000 lbs \n3600 m 6700 lbs\n4000 m 8000 lbs", "dTimEnd": "2015-10-31T18:30:00+01:00", "dTimStart": "2015-10-31T14:15:00+01:00", "md": "4030", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed gun check, OK. Performed first correlation pass at 10 m/min from 4030 to 3930 m. Observed high pulling weighs at between 8000-9000 lbs (Schlumberger counter). Adjusted depth by +4 m.", "dTimEnd": "2015-10-31T18:50:00+01:00", "dTimStart": "2015-10-31T18:30:00+01:00", "md": "3930", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor and tractored back down. Tractor speed approx. 2-3 m/min.", "dTimEnd": "2015-10-31T20:10:00+01:00", "dTimStart": "2015-10-31T18:50:00+01:00", "md": "4034", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to logging. Performed second correlation pass at 10 m/min. Max tension 9800 lbs (Schlumberger counter).", "dTimEnd": "2015-10-31T20:40:00+01:00", "dTimStart": "2015-10-31T20:10:00+01:00", "md": "3930", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Repeated sequence and performed 3 passes between 4030 to 3930 m, to ensure perforation guns properly oriented.", "dTimEnd": "2015-10-31T23:30:00+01:00", "dTimStart": "2015-10-31T20:40:00+01:00", "md": "3930", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Tractored back down prior to position guns for perforation.", "dTimEnd": "2015-11-01T00:00:00+01:00", "dTimStart": "2015-10-31T23:30:00+01:00", "md": "4020", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_11_02
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-11-01T00:00:00+01:00
2015-11-02T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-11-02T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "L/D toolstring. Inflow test XMT barriers for handover. R/D WL equipment.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "9", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Perforated zone from 3960-3969 m. POOH and prepared toolstring for next perforation. RIH and started to correlate depth prior to perforate.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Switched over to logging. Logged up from 4020 m and positioned toolstring with top shot at 3960 m. Perforated interval 3960 - 3969 m. WHP 119 bar. No indication on cable tension, DHPG increased by 0,3 bar. Logged up after shooting.", "dTimEnd": "2015-11-01T00:30:00+01:00", "dTimStart": "2015-11-01T00:00:00+01:00", "md": "3900", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 3900 m to 2800 m . Observed leak on grease skid.", "dTimEnd": "2015-11-01T01:30:00+01:00", "dTimStart": "2015-11-01T00:30:00+01:00", "md": "2800", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Leak on the drum for one of the hoses running from the grease skid up to GIH. Isolated same and continued POOH with only one hose injecting grease to GIH.", "dTimEnd": "2015-11-01T02:00:00+01:00", "dTimStart": "2015-11-01T01:30:00+01:00", "md": "2800", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to POOH from 2800 m to surface. When at DHSV depth performed PA announcement for handling explosives on drillfloor.", "dTimEnd": "2015-11-01T03:40:00+01:00", "dTimStart": "2015-11-01T02:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed SV and HMV and inflow tested same. Purged lubricator with N2.", "dTimEnd": "2015-11-01T05:25:00+01:00", "dTimStart": "2015-11-01T03:40:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed toolbox talk prior to break lubricator and L/D toolstring.", "dTimEnd": "2015-11-01T05:35:00+01:00", "dTimStart": "2015-11-01T05:25:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator and L/D BHA #2. Observed all shots fired.", "dTimEnd": "2015-11-01T07:00:00+01:00", "dTimStart": "2015-11-01T05:35:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Altus and Schlumberger started tool check for next perforation toolstring.\nMeanwhile Altus wireline changed grease hose on GIH.", "dTimEnd": "2015-11-01T11:30:00+01:00", "dTimStart": "2015-11-01T07:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed toolbox talk prior to M/U BHA#3.", "dTimEnd": "2015-11-01T11:45:00+01:00", "dTimStart": "2015-11-01T11:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed BHA #3 tractor and 4,5\" perforation guns into lubricator.\nAdded 40 litres of Starlube into lubricator.", "dTimEnd": "2015-11-01T12:50:00+01:00", "dTimStart": "2015-11-01T11:45:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Stabbed lubricator and leak tested QTS to 20/345 bar for 5/10 min. Production filled lubricator with MEG using permanent line into XMT cross. Equalized and opened HMV and SV. WHP 119 bar.", "dTimEnd": "2015-11-01T14:00:00+01:00", "dTimStart": "2015-11-01T12:50:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ BHA #3 Tractor and 4,5\" perforation guns from surface to 300 m.", "dTimEnd": "2015-11-01T14:20:00+01:00", "dTimStart": "2015-11-01T14:00:00+01:00", "md": "300", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Powered up tool and checked communication.", "dTimEnd": "2015-11-01T14:25:00+01:00", "dTimStart": "2015-11-01T14:20:00+01:00", "md": "300", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to RIH from 300 m to 2800 m. Tool stopped. Had to start tractor.", "dTimEnd": "2015-11-01T16:15:00+01:00", "dTimStart": "2015-11-01T14:25:00+01:00", "md": "2800", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor. Observed problems with tractor communication.", "dTimEnd": "2015-11-01T16:30:00+01:00", "dTimStart": "2015-11-01T16:15:00+01:00", "md": "2800", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Checked tractor power supply. OK. Checked all connections. Found loose connection. Communication OK.", "dTimEnd": "2015-11-01T17:30:00+01:00", "dTimStart": "2015-11-01T16:30:00+01:00", "md": "2800", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Tractored down from 2800 m to 4030 m. Tractor speed decreased to approx. 2-4 m/min.", "dTimEnd": "2015-11-01T21:35:00+01:00", "dTimStart": "2015-11-01T17:30:00+01:00", "md": "4030", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Swiched over to logging and performed first correlation pass at 10 m/min from 4030 to 3860 m. Run back in and repeated sequence for orientation of guns. Run back in with tractor.", "dTimEnd": "2015-11-02T00:00:00+01:00", "dTimStart": "2015-11-01T21:35:00+01:00", "md": "3860", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2015_11_03
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2015-11-02T00:00:00+01:00
2015-11-03T00:00:00+01:00
normal
2018-05-03T13:51:40+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2015-11-03T00:00:00+01:00", "dTimDiaHoleStart": "2015-10-24T21:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Rig up wireline equipment on F-5.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "4770", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "10", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Perforated zone from 3910 m to 3919 m. POOH and L/D toolstring. Rigged down equipment and tested XMT barriers. Handed well over to production.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Switched over logging and performed second orientation pass at 10 m/min from 4030 m to 3860 m.", "dTimEnd": "2015-11-02T00:30:00+01:00", "dTimStart": "2015-11-02T00:00:00+01:00", "md": "3860", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to tractor and RIH to position gun prior to perforate.", "dTimEnd": "2015-11-02T01:30:00+01:00", "dTimStart": "2015-11-02T00:30:00+01:00", "md": "4020", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched over to logging and P/U to position for perforation. Observed log was 1 meter shallow. Repeated pass, still shallow. Shifted depth +0,7 m. Performed new pass and positioned gun. Perforated interval 3910 - 3919 m. Observed shots fired on tension. WHP 118 bar.", "dTimEnd": "2015-11-02T02:45:00+01:00", "dTimStart": "2015-11-02T01:30:00+01:00", "md": "3918", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Logged up. Observed logging tool not communicating. Stopped and checked communication. Possible short in tool after perforation.", "dTimEnd": "2015-11-02T03:00:00+01:00", "dTimStart": "2015-11-02T02:45:00+01:00", "md": "3853", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 3853 m to surface.", "dTimEnd": "2015-11-02T05:30:00+01:00", "dTimStart": "2015-11-02T03:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed SV & HMV and inflow tested same. Purged lubricator with N2.", "dTimEnd": "2015-11-02T07:30:00+01:00", "dTimStart": "2015-11-02T05:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed toolbox talk prior to L/D BHA #3.", "dTimEnd": "2015-11-02T07:45:00+01:00", "dTimStart": "2015-11-02T07:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator and L/D BHA #3 on deck. All shots fired.", "dTimEnd": "2015-11-02T08:30:00+01:00", "dTimStart": "2015-11-02T07:45:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Latched lubricator for lifting lubricator & BOP.", "dTimEnd": "2015-11-02T09:00:00+01:00", "dTimStart": "2015-11-02T08:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed BOP and opened HMV for inflow testing of DHSV. Bled off pressure above DHSV. \nMeanwhile held toolbox talk prior to rig down lubricator, BOP and riser from XMT.", "dTimEnd": "2015-11-02T14:30:00+01:00", "dTimStart": "2015-11-02T09:00:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- test scsssv", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed HMV and bleed off pressure below BOP.", "dTimEnd": "2015-11-02T14:55:00+01:00", "dTimStart": "2015-11-02T14:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected hoses to BOP and prepared to lift rig up off XMT. Disconnected riser on XMT. Lifted lubricator, BOP and riser using top-drive and double securing, secured same in rotary.", "dTimEnd": "2015-11-02T18:10:00+01:00", "dTimStart": "2015-11-02T14:55:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed top cap and leak tested XMT top cap to 20/345 bar for 5/10 min.\nMeanwhile prepared for skidding rig.", "dTimEnd": "2015-11-02T18:45:00+01:00", "dTimStart": "2015-11-02T18:10:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- test scsssv", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Had to wait due to skidding from F-11B to F-5.", "dTimEnd": "2015-11-02T19:30:00+01:00", "dTimStart": "2015-11-02T18:45:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed KWV cap and leak tested same to 20/345 bar for 5/10 min.", "dTimEnd": "2015-11-02T20:30:00+01:00", "dTimStart": "2015-11-02T19:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- test scsssv", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected lines for local control of DHSV and HMV. Cleaned and tidyed area. Handed well over to production.\n\n------------------------- END OF OPERATION -----------------------------", "dTimEnd": "2015-11-02T21:00:00+01:00", "dTimStart": "2015-11-02T20:30:00+01:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_15
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-14T00:00:00+02:00
2016-04-15T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-15T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-14T19:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "R/U WL equipment. Perforate well.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "1", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Recieved and spotted equipment", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Held Pre-job meeting with night crew.", "dTimEnd": "2016-04-14T19:30:00+02:00", "dTimStart": "2016-04-14T19:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Vessel arrived rig. Unloaded WL equipment from vessel.", "dTimEnd": "2016-04-15T00:00:00+02:00", "dTimStart": "2016-04-14T19:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_16
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-15T00:00:00+02:00
2016-04-16T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-16T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-14T19:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "None", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "2", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Prepared WL equipment for rig up. Started to shut-in well.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Spotted equipment on pipedeck according to spotting plan. Checked and and verified all equipment recieved.", "dTimEnd": "2016-04-15T03:00:00+02:00", "dTimStart": "2016-04-15T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Prepared hoses and cables for hookup of surface equipment.", "dTimEnd": "2016-04-15T07:00:00+02:00", "dTimStart": "2016-04-15T03:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting with day crew.", "dTimEnd": "2016-04-15T07:30:00+02:00", "dTimStart": "2016-04-15T07:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to prepare equipment prior to rig up. \n\n", "dTimEnd": "2016-04-15T09:00:00+02:00", "dTimStart": "2016-04-15T07:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Started to verify equipment according to Maersk checklist for hookup to rig.\n", "dTimEnd": "2016-04-15T12:00:00+02:00", "dTimStart": "2016-04-15T09:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted Grease injection head and toolcatcher to drillfloor. \nFed cable through GIH.\n", "dTimEnd": "2016-04-15T13:30:00+02:00", "dTimStart": "2016-04-15T12:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Maersk electrician connected power to Altus and SLB units.\n\nMeanwhile, lifted PCE equipment to drillfloor.", "dTimEnd": "2016-04-15T16:00:00+02:00", "dTimStart": "2016-04-15T13:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox talk with involved personell prior to start building riser.", "dTimEnd": "2016-04-15T16:30:00+02:00", "dTimStart": "2016-04-15T16:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Built riser and lubricator section on catwalk using tugger.\n\nMeanwhile, finalized and function tested WL winch. Schlumberger built cable head.", "dTimEnd": "2016-04-15T19:00:00+02:00", "dTimStart": "2016-04-15T16:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Schlumberger tested primary BHA. \n\nMeanwhile, Leak tested BOP on stump to 20/345 bar for 5/10 min. Function tested BOP rams.", "dTimEnd": "2016-04-15T23:45:00+02:00", "dTimStart": "2016-04-15T19:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Production department started to close in well for handover.", "dTimEnd": "2016-04-16T00:00:00+02:00", "dTimStart": "2016-04-15T23:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_17
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-16T00:00:00+02:00
2016-04-17T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-17T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-14T19:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Perforate well. R/D WL equipment", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "3", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Prepared WL equipment for rig-up. Handover of well. Rigged up WL Equipment", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Altus worked on lubricator and riser section.\n\nMeanwhile, Schlumberger tested B/U equipment.", "dTimEnd": "2016-04-16T01:30:00+02:00", "dTimStart": "2016-04-16T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox talk prior to lifting BOP to moonpool area.", "dTimEnd": "2016-04-16T02:00:00+02:00", "dTimStart": "2016-04-16T01:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted BOP down to moonpool area. Spooled out hoses for BOP, HMV and DHSV to moonpool.", "dTimEnd": "2016-04-16T03:00:00+02:00", "dTimStart": "2016-04-16T02:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to feed cable head (3,125'') through lubricator. Unable to due to small ID of X-over (3'') in lubricator.", "dTimEnd": "2016-04-16T03:30:00+02:00", "dTimStart": "2016-04-16T03:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Schlumberger disconnected bottom of cable head and fed cable through lubricator.", "dTimEnd": "2016-04-16T04:00:00+02:00", "dTimStart": "2016-04-16T03:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Connected GIH to lubricator section using tugger and catwalk. Spooled out and connected hoses to GIH.\n\nMeanwhile, Schlumberger re-connected cable head and began signal test to equipment.", "dTimEnd": "2016-04-16T06:00:00+02:00", "dTimStart": "2016-04-16T04:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited while production department tested well barriers prior to handover.", "dTimEnd": "2016-04-16T09:00:00+02:00", "dTimStart": "2016-04-16T06:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed handover meeting between production and Intervention. Verified valve status on XMT with production representant.", "dTimEnd": "2016-04-16T09:45:00+02:00", "dTimStart": "2016-04-16T09:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox talk prior to lifting riser and lubricator section", "dTimEnd": "2016-04-16T10:10:00+02:00", "dTimStart": "2016-04-16T09:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted and replaced permanent hatch with WL hatch.", "dTimEnd": "2016-04-16T11:15:00+02:00", "dTimStart": "2016-04-16T10:10:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed XMT top cap on well.", "dTimEnd": "2016-04-16T11:40:00+02:00", "dTimStart": "2016-04-16T11:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted and connected lower riser to XMT.", "dTimEnd": "2016-04-16T12:00:00+02:00", "dTimStart": "2016-04-16T11:40:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed BOP on lower riser. Connected hoses to BOP and function tested same. Verified open / close time.", "dTimEnd": "2016-04-16T13:10:00+02:00", "dTimStart": "2016-04-16T12:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up KWV manifold and bleed-off hoses on wellhead.", "dTimEnd": "2016-04-16T14:00:00+02:00", "dTimStart": "2016-04-16T13:10:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted middle riser section and landed on top of BOP.", "dTimEnd": "2016-04-16T14:30:00+02:00", "dTimStart": "2016-04-16T14:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox talk prior to lifting lubricator to middle riser.", "dTimEnd": "2016-04-16T15:00:00+02:00", "dTimStart": "2016-04-16T14:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted lubricator and GIH to middle riser. Installed Schlumberger dummy BHA in lubricator and stabbed onto middle riser.", "dTimEnd": "2016-04-16T16:30:00+02:00", "dTimStart": "2016-04-16T15:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Connected hoses for operating HMV and DHSV.", "dTimEnd": "2016-04-16T17:00:00+02:00", "dTimStart": "2016-04-16T16:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Filled lubricator with MEG from production department.\nLeak tested rig-up to 20/345 bar for 5/10 min.", "dTimEnd": "2016-04-16T18:50:00+02:00", "dTimStart": "2016-04-16T17:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Purged lubricator with N2.", "dTimEnd": "2016-04-16T19:30:00+02:00", "dTimStart": "2016-04-16T18:50:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Verified no liquid in rig-up prior to installing perforation BHA in well. Broke lubricator and L/D Schlumberger dummy BHA.", "dTimEnd": "2016-04-16T19:50:00+02:00", "dTimStart": "2016-04-16T19:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox talk prior to installing perforation BHA in well.", "dTimEnd": "2016-04-16T20:15:00+02:00", "dTimStart": "2016-04-16T19:50:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U BHA for perforation run #1 (3 3/8'' PJN guns w/ 3 1/8'' Tufftrac). Leak tested QTS to 20/345 bar 5/10 min. \nDumped 40 l Starlube in lubricator.", "dTimEnd": "2016-04-16T23:00:00+02:00", "dTimStart": "2016-04-16T20:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened HMV and pressurized DHSV control line.", "dTimEnd": "2016-04-17T00:00:00+02:00", "dTimStart": "2016-04-16T23:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_18
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-17T00:00:00+02:00
2016-04-18T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-18T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-14T19:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Skid to F-5", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "4", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Perforated well. R/D WL equipment", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Standby while production department used another well to equalize and open DHSV.", "dTimEnd": "2016-04-17T02:20:00+02:00", "dTimStart": "2016-04-17T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened DHSV and SV. WHP = 69 bar.", "dTimEnd": "2016-04-17T02:40:00+02:00", "dTimStart": "2016-04-17T02:20:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ run #1 (Perforation guns w/ Tractor), 3,375\" OD guns by gravity from surface to 600 m.", "dTimEnd": "2016-04-17T03:25:00+02:00", "dTimStart": "2016-04-17T02:40:00+02:00", "md": "600", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Schlumberger performed communication check with toolstring.\n\nMeanwhile, Held well contol exercise with WL crew. \nScenario: Leakage in QTS with BHA at 1500 mMD.", "dTimEnd": "2016-04-17T03:45:00+02:00", "dTimStart": "2016-04-17T03:25:00+02:00", "md": "600", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continue to RIH with BHA #1 from 600 mMD to HUD at 2810 mMD taking PUW every 500m. \n\nDepth (m) PUW (lbs) Sim PUW (lbs) HW (lbs) \n1000 2810 2511 2360\n1500 3600 3258 3200\n2000 4300 4279 3840\n2500 5400 5482 4919\n\nActual friction factor: 0.289.\n\n", "dTimEnd": "2016-04-17T04:45:00+02:00", "dTimStart": "2016-04-17T03:45:00+02:00", "md": "2810", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Activated tractor and continued to RIH with from 2810 mMD to 3550 mMD . Average running speed w/ Tractor: 9 m/min.\n\nDepth (mMD) PUW (lbs) Sim PUW (lbs) \n3050 5450 5950 \n3300 5600 6270 \n", "dTimEnd": "2016-04-17T06:35:00+02:00", "dTimStart": "2016-04-17T04:45:00+02:00", "md": "3550", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Contined to RIH with tractor activated to 3642 mMD. Tractor seemed to struggle. Shut down tractor, picked up full weight and slacked off 10m. \nStarted tractor again and RIH to 3740 mMD.", "dTimEnd": "2016-04-17T07:10:00+02:00", "dTimStart": "2016-04-17T06:35:00+02:00", "md": "3740", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed orientation pass #1. Some stick and slip observed. Increased tractor arm force.", "dTimEnd": "2016-04-17T07:50:00+02:00", "dTimStart": "2016-04-17T07:10:00+02:00", "md": "3740", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to RIH with tractor activated to 3900mMD. Performed orientation pass #2 and stopped tractor.", "dTimEnd": "2016-04-17T09:10:00+02:00", "dTimStart": "2016-04-17T07:50:00+02:00", "md": "3900", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed correlation logging from 3900 mMD to 3600 mMD.", "dTimEnd": "2016-04-17T09:40:00+02:00", "dTimStart": "2016-04-17T09:10:00+02:00", "md": "3600", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Activated tractor and RIH to 3710 mMD. Tractor stalled out.", "dTimEnd": "2016-04-17T10:40:00+02:00", "dTimStart": "2016-04-17T09:40:00+02:00", "md": "3710", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched to logging mode. Performed correlation pass from 3710 mMD to 3600 mMD.", "dTimEnd": "2016-04-17T10:50:00+02:00", "dTimStart": "2016-04-17T10:40:00+02:00", "md": "3600", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Activated tractor and RIH to 3710 mMD. Tractor stalled out at same depth as previously.", "dTimEnd": "2016-04-17T11:40:00+02:00", "dTimStart": "2016-04-17T10:50:00+02:00", "md": "3710", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched to logging mode and performed correlation pass. Positioned Gun 1 with bottom shots at 3684 mMD.", "dTimEnd": "2016-04-17T12:00:00+02:00", "dTimStart": "2016-04-17T11:40:00+02:00", "md": "3684", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Perforated interval 3675 - 3684 mMD and lost 250 lbs on tension. \nWHP before/ after: 79,0 / 79,9 bar. \nA-annulus before / after: 12,4 / 12,1 bar.", "dTimEnd": "2016-04-17T12:05:00+02:00", "dTimStart": "2016-04-17T12:00:00+02:00", "md": "3684", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed correlation pass for gun #2 while pulling out to 3438 mMD.", "dTimEnd": "2016-04-17T12:27:00+02:00", "dTimStart": "2016-04-17T12:05:00+02:00", "md": "3438", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Activated tractor and RIH to 3562 mMD while performing correlation pass for gun #2.", "dTimEnd": "2016-04-17T12:55:00+02:00", "dTimStart": "2016-04-17T12:27:00+02:00", "md": "3562", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Switched to logging mode and performed correlation pass. Positioned Gun 2 with bottom shots at 3481 mMD.", "dTimEnd": "2016-04-17T13:10:00+02:00", "dTimStart": "2016-04-17T12:55:00+02:00", "md": "3481", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Perforated interval 3475 - 3481 mMD and lost 400 lbs on tension. \nWHP before/ after: 81,2 / 81,7 bar. \nA-annulus before / after: 12,0 / 12,0 bar.", "dTimEnd": "2016-04-17T13:15:00+02:00", "dTimStart": "2016-04-17T13:10:00+02:00", "md": "3481", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH to 3300 mMD while correlating depth.", "dTimEnd": "2016-04-17T13:25:00+02:00", "dTimStart": "2016-04-17T13:15:00+02:00", "md": "3300", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 3300 m to surface. WHP 84 bar.", "dTimEnd": "2016-04-17T15:50:00+02:00", "dTimStart": "2016-04-17T13:25:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed and inflow tested SV. Closed HMV. Valve needed to be greased before test.", "dTimEnd": "2016-04-17T17:05:00+02:00", "dTimStart": "2016-04-17T15:50:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited while production department greased HMV.", "dTimEnd": "2016-04-17T17:25:00+02:00", "dTimStart": "2016-04-17T17:05:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed and inflow tested HMV. Purged lubricator with N2.", "dTimEnd": "2016-04-17T18:00:00+02:00", "dTimStart": "2016-04-17T17:25:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox meeting prior to L/D BHA with explosives.", "dTimEnd": "2016-04-17T18:15:00+02:00", "dTimStart": "2016-04-17T18:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator and L/D BHA #1 (Perforation guns w/ tractor). Confirmed all shots fired.", "dTimEnd": "2016-04-17T19:00:00+02:00", "dTimStart": "2016-04-17T18:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U dummy BHA for testing lubricator. Installed and stabbed lubricator. Attempted to Leak tested QTS. Found leakage in a O-ring.", "dTimEnd": "2016-04-17T19:50:00+02:00", "dTimStart": "2016-04-17T19:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed damaged O-Ring in lubricator and leak tested same to 20/345 bar for 5/10 min.", "dTimEnd": "2016-04-17T20:10:00+02:00", "dTimStart": "2016-04-17T19:50:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed DHSV and opened HMV. Bled down pressure in tubing to 10 bar.", "dTimEnd": "2016-04-17T23:06:00+02:00", "dTimStart": "2016-04-17T20:10:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- test scsssv", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Inflow tested DHSV with 74 bar dP. Pressure increased 0,1 bar/30min.", "dTimEnd": "2016-04-17T23:40:00+02:00", "dTimStart": "2016-04-17T23:06:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- test scsssv", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Bled off pressure above DHSV before disconnecting lubricator.", "dTimEnd": "2016-04-18T00:00:00+02:00", "dTimStart": "2016-04-17T23:40:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_19
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-18T00:00:00+02:00
2016-04-19T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-19T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-14T19:00:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Move to F-5", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "5", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "R/D WL equipment", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued to bleed off tubing pressure to 0 bar. Slow progress due to unable to use PWV for bleed off.", "dTimEnd": "2016-04-18T02:45:00+02:00", "dTimStart": "2016-04-18T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed HMV. Broke lubricator and L/D dummy BHA.", "dTimEnd": "2016-04-18T03:00:00+02:00", "dTimStart": "2016-04-18T02:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D lubricator and GIH on catwalk using rig crane and top drive.", "dTimEnd": "2016-04-18T03:35:00+02:00", "dTimStart": "2016-04-18T03:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Connected lifting sub to middle riser section.", "dTimEnd": "2016-04-18T04:00:00+02:00", "dTimStart": "2016-04-18T03:35:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected lower riser from XMT. Lifted entire riser section and BOP from XMT up to moonpool area.", "dTimEnd": "2016-04-18T04:15:00+02:00", "dTimStart": "2016-04-18T04:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed top cap on XMT.", "dTimEnd": "2016-04-18T04:20:00+02:00", "dTimStart": "2016-04-18T04:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Tested KWV cap and top cap to 20/345 bar for 5/10 min.", "dTimEnd": "2016-04-18T04:55:00+02:00", "dTimStart": "2016-04-18T04:20:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Replaced WL hatch with permanent hatch. Handed well back to production.\n\n----------------- End of Operation ---------------------", "dTimEnd": "2016-04-18T06:00:00+02:00", "dTimStart": "2016-04-18T04:55:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_21
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-20T00:00:00+02:00
2016-04-21T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-21T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-20T06:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Rig up WL, Install Straddles (2 Run), R/D WL equipment", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "6", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Received well from production. Rigged up WL equipment. Unable to leak test Rig-up.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Waited for supply vessel to arrive with straddle equipment.\n\nMeanwhile, skidded rig to F-11.", "dTimEnd": "2016-04-20T09:30:00+02:00", "dTimStart": "2016-04-20T06:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Vessel arrived rig with equipment.", "dTimEnd": "2016-04-20T10:00:00+02:00", "dTimStart": "2016-04-20T09:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Checked and verified the received straddle equipment OK.", "dTimEnd": "2016-04-20T12:15:00+02:00", "dTimStart": "2016-04-20T10:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited while production department prepared well for handover.\n\nMeanwhile, cleaned and tidy rig floor and pipe deck.", "dTimEnd": "2016-04-20T16:30:00+02:00", "dTimStart": "2016-04-20T12:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Received well from production department.", "dTimEnd": "2016-04-20T16:45:00+02:00", "dTimStart": "2016-04-20T16:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Replaced permanent hatch with WL hatch", "dTimEnd": "2016-04-20T17:30:00+02:00", "dTimStart": "2016-04-20T16:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Inflow tested SV and TKV on XMT. Leak tested KWV to 20/345 bar for 5/10 min.", "dTimEnd": "2016-04-20T18:00:00+02:00", "dTimStart": "2016-04-20T17:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Hooked up chiksan manifold on KW and leak tested same to 20/345 bar for 5/10 min.", "dTimEnd": "2016-04-20T18:30:00+02:00", "dTimStart": "2016-04-20T18:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed top cap on XMT.", "dTimEnd": "2016-04-20T18:40:00+02:00", "dTimStart": "2016-04-20T18:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted riser section and BOP from moonpool area and landed on XMT.", "dTimEnd": "2016-04-20T19:45:00+02:00", "dTimStart": "2016-04-20T18:40:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Connected hoses for test pump and local control of DHSV and HMV on XMT.", "dTimEnd": "2016-04-20T20:35:00+02:00", "dTimStart": "2016-04-20T19:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox talk prior to lifting lubricator and GIH.", "dTimEnd": "2016-04-20T20:45:00+02:00", "dTimStart": "2016-04-20T20:35:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted lubricator and GIH from catwalk and hung off same above riser section on drill floor.", "dTimEnd": "2016-04-20T21:20:00+02:00", "dTimStart": "2016-04-20T20:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U BHA for run #2 (Straddle w/ tractor) in Lubricator. Added 80 L starlube in riser before stabbing lubricator. Filled lubricator with MEG. \nAttempted to leak test rig-up to 20/345 bar for 5/10 min. Dicovered leakage in GIH due to error in Grease pump.", "dTimEnd": "2016-04-20T22:45:00+02:00", "dTimStart": "2016-04-20T21:20:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited while Altus and Maersk mechanic fixed grease pump.", "dTimEnd": "2016-04-21T00:00:00+02:00", "dTimStart": "2016-04-20T22:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_22
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-21T00:00:00+02:00
2016-04-22T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-22T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-20T06:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Install straddles, R/D and demobilize WL equipment.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "7", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Waited for repair of grease pump. R/D WL equipment and changed O-rings in X-over. R/U WL equipment.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Waited for Altus and Maersk mechanic to fix grease pump. Achieved good test of 345 bar on lubricator, but pump still not working as it should. Grease pump stroke increased rapidly due to pump not able to deliver enough grease pressure.", "dTimEnd": "2016-04-21T00:45:00+02:00", "dTimStart": "2016-04-21T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to open HMV and equalizing manifold to pressure up lubricator with N2 and displace Starlube and MEG into well. Unable to open HMV due to error in HMV pump.", "dTimEnd": "2016-04-21T01:00:00+02:00", "dTimStart": "2016-04-21T00:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited while Altus fixed HMV pump. Most likely caused by air in pump system.", "dTimEnd": "2016-04-21T02:00:00+02:00", "dTimStart": "2016-04-21T01:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened HMV and injected N2 in lubricator and bullheaded MEG/Starlube mix into well.\n\nMeanwhile, Grease pump started to work properly again.", "dTimEnd": "2016-04-21T02:35:00+02:00", "dTimStart": "2016-04-21T02:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed HMV and bled off pressure in lubricator.", "dTimEnd": "2016-04-21T02:55:00+02:00", "dTimStart": "2016-04-21T02:35:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator and added 80 L Starlube in riser.", "dTimEnd": "2016-04-21T03:05:00+02:00", "dTimStart": "2016-04-21T02:55:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Stabbed lubricator and filled rig-up with MEG. Attempted to leak test rig-up, but grease pump was unable to deliver grease pressure.", "dTimEnd": "2016-04-21T03:30:00+02:00", "dTimStart": "2016-04-21T03:05:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Altus worked on grease pump issue with Maersk mechanic and electrician.", "dTimEnd": "2016-04-21T08:30:00+02:00", "dTimStart": "2016-04-21T03:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Grease pump OK.\n\nWaited for approval from onshore organisation if OK to RIH.", "dTimEnd": "2016-04-21T14:00:00+02:00", "dTimStart": "2016-04-21T08:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Leak tested lubricator to 20/345 bar for 5/10 min. Opened HMV", "dTimEnd": "2016-04-21T14:30:00+02:00", "dTimStart": "2016-04-21T14:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Equalized and opened DHSV. WHP = 62 bar. Observed leakage in O-ring on X-over between XMT and lower riser.", "dTimEnd": "2016-04-21T16:00:00+02:00", "dTimStart": "2016-04-21T14:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed DHSV and bled down pressure in tubing to 3 bar.", "dTimEnd": "2016-04-21T17:55:00+02:00", "dTimStart": "2016-04-21T16:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Inflow tested DHSV to 59 bar dP for 30 min.", "dTimEnd": "2016-04-21T18:50:00+02:00", "dTimStart": "2016-04-21T17:55:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Bled off remaining pressure in tubing to 0 bar", "dTimEnd": "2016-04-21T19:55:00+02:00", "dTimStart": "2016-04-21T18:50:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed HMV and purged lubricator with N2.", "dTimEnd": "2016-04-21T20:50:00+02:00", "dTimStart": "2016-04-21T19:55:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator and L/D BHA #2 (Straddle w/ Tractor) on drill floor.", "dTimEnd": "2016-04-21T21:30:00+02:00", "dTimStart": "2016-04-21T20:50:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected lower riser from X-over and liftet Riser section and BOP using top drive with double securing. \nChanged O-ring on X-over and stabbed riser back onto X-over.", "dTimEnd": "2016-04-21T22:10:00+02:00", "dTimStart": "2016-04-21T21:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected XMT from X-over and liftet Riser section and BOP using top drive with double securing. \nChanged O-ring on X-over and stabbed riser back onto XMT. \nOne of the O-rings had some small marks.", "dTimEnd": "2016-04-21T22:20:00+02:00", "dTimStart": "2016-04-21T22:10:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed shear ram on BOP and leak tested between SV and BOP to 200 bar for 10 min.", "dTimEnd": "2016-04-21T22:40:00+02:00", "dTimStart": "2016-04-21T22:20:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted lubricator and GIH and hung it off above riser section using rig crane and top drive.", "dTimEnd": "2016-04-21T23:10:00+02:00", "dTimStart": "2016-04-21T22:40:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U BHA for run #2 (Straddle w/ tractor).", "dTimEnd": "2016-04-22T00:00:00+02:00", "dTimStart": "2016-04-21T23:10:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_23
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-22T00:00:00+02:00
2016-04-23T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-23T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-20T06:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "POOH and L/D BHA. Inflowtest valves and hand over well to production dep. R/D.", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "8", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Tested RU. Opened well and RIH to 2830 m. Tractored down to 3735 mMD. Made multiple correlation passes. Set straddle across interval 3674.4 - 3685 mMD. POOH and L/D BHA. M/U BHA #3 (Straddle-Tractor) and RIH. ", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Stabbed on lubricator and leak tested rig-up to 20/345 bar for 5/10 min using 100% MEG.", "dTimEnd": "2016-04-22T01:15:00+02:00", "dTimStart": "2016-04-22T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened HMV. Equalized and opened DHSV. WHP 59 bar.", "dTimEnd": "2016-04-22T02:10:00+02:00", "dTimStart": "2016-04-22T01:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ run #2 (563-700 Straddle-Resolve-TuffTRAC; max OD 5.63\" straddle) from surface to HUD at 2830 m. Performed PU every 500 m.\n\nDepth (m) PUW (lbs)\n500 3000\n1000 3650\n1500 4650 \n2000 5250\n2500 6550", "dTimEnd": "2016-04-22T04:45:00+02:00", "dTimStart": "2016-04-22T02:10:00+02:00", "md": "2830", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Activated tractor and RIH with tractor from 2830 m to 3580 m. Average running speed 9 m/min. WHP 63 bar.", "dTimEnd": "2016-04-22T07:00:00+02:00", "dTimStart": "2016-04-22T04:45:00+02:00", "md": "3580", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued RIH with tractor activated from 3580 m to 3735 m. Average running speed 8 m/min.", "dTimEnd": "2016-04-22T07:35:00+02:00", "dTimStart": "2016-04-22T07:00:00+02:00", "md": "3735", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed 8 correlation passes in interval 3730 - 3640 mMD. Experienced severe stick-slip and difficulties getting on depth with correlation log.", "dTimEnd": "2016-04-22T13:00:00+02:00", "dTimStart": "2016-04-22T07:35:00+02:00", "md": "3745", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Made 2 attempt to position BHA at setting depth by logging up from 3720 mMD. Slightly off-depth from correlation log, unable to position straddle within desired uncertainty margin. Positioned BHA on third pass by logging up from 3720 mMD to 3766.8 mMD.", "dTimEnd": "2016-04-22T14:30:00+02:00", "dTimStart": "2016-04-22T13:00:00+02:00", "md": "3785.6", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Set straddle across interval 3674.4 - 3685.0 mMD. Lost 2000 lbs immediately. Tagged straddle with tractor to verify set.\nWHP 67 bar.", "dTimEnd": "2016-04-22T15:00:00+02:00", "dTimStart": "2016-04-22T14:30:00+02:00", "md": "3765.8", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 3765 mMD to surface. Average pulling speed 30 m/min. WHP 69 bar.", "dTimEnd": "2016-04-22T17:25:00+02:00", "dTimStart": "2016-04-22T15:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed and inflow tested SV and HMV. Purge riser with N2.", "dTimEnd": "2016-04-22T18:45:00+02:00", "dTimStart": "2016-04-22T17:25:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed tool-box talk on drillfloor prior to L/D BHA.", "dTimEnd": "2016-04-22T19:05:00+02:00", "dTimStart": "2016-04-22T18:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator. L/D BHA on deck.", "dTimEnd": "2016-04-22T19:30:00+02:00", "dTimStart": "2016-04-22T19:05:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Checked cable head and tractor for next run.", "dTimEnd": "2016-04-22T20:45:00+02:00", "dTimStart": "2016-04-22T19:30:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed tool-box talk on drillfloor prior to M/U BHA.", "dTimEnd": "2016-04-22T20:55:00+02:00", "dTimStart": "2016-04-22T20:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U BHA for run #3 (563-700 Straddle-Resolve-TuffTRAC).", "dTimEnd": "2016-04-22T21:35:00+02:00", "dTimStart": "2016-04-22T20:55:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Stabbed on lubricator and tested QTS to 20/345 bar for 5/10 min.", "dTimEnd": "2016-04-22T22:05:00+02:00", "dTimStart": "2016-04-22T21:35:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Equalized and opened HMV and SV. HW 2280 lbs. WHP 71 bar.", "dTimEnd": "2016-04-22T22:25:00+02:00", "dTimStart": "2016-04-22T22:05:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ run #2 (563-700 Straddle-Resolve-TuffTRAC; max OD 5.63\" straddle) from surface to 2050 mMD. Performed PU every 500 m.", "dTimEnd": "2016-04-23T00:00:00+02:00", "dTimStart": "2016-04-22T22:25:00+02:00", "md": "2050", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_24
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-23T00:00:00+02:00
2016-04-24T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-24T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-20T06:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Continue packing for demobilization. ", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "9", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Correlated and set straddle. POOH. L/D BHA and R/D WL equipment. ", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued RIH from 2050 mMD to HUD at 2830 mMD. Performed PU every 500 m.\n\nDepth (m) PUW (lbs)\n500 3000\n1000 3530\n1500 4500 \n2000 5200\n2500 6200", "dTimEnd": "2016-04-23T00:35:00+02:00", "dTimStart": "2016-04-23T00:00:00+02:00", "md": "2830", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with tractor activated from 2830 m to 3490 mMD. Average running speed 9 m/min.", "dTimEnd": "2016-04-23T02:10:00+02:00", "dTimStart": "2016-04-23T00:35:00+02:00", "md": "3490", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated multiple times across interval 3525 - 3470 mMD. Experience stick-slip and high tension (pulled maximum 9500 lbs), which affected logging quality.", "dTimEnd": "2016-04-23T04:45:00+02:00", "dTimStart": "2016-04-23T02:10:00+02:00", "md": "3515", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Positioned straddle with top element at 3474.5 mMD. Verified depth with Petec and picked up 1.5 m to 3473 mMD to have straddle elements symmetrical over perforations.", "dTimEnd": "2016-04-23T05:05:00+02:00", "dTimStart": "2016-04-23T04:45:00+02:00", "md": "3485.7", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Set straddle across interval 3473.0 - 3483.5 mMD. Lost appr. 3400 lbs on surface tension, head tension dropped 1000 lbs. Completed setting sequence and tagged straddle with tractor to verify set. WHP 77 bar.", "dTimEnd": "2016-04-23T05:35:00+02:00", "dTimStart": "2016-04-23T05:05:00+02:00", "md": "3484.2", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 3484mMD to surface. Average pulling speed 30 m/min.", "dTimEnd": "2016-04-23T07:40:00+02:00", "dTimStart": "2016-04-23T05:35:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed and inflow tested HMV and SV. WHP 80 bar.", "dTimEnd": "2016-04-23T09:00:00+02:00", "dTimStart": "2016-04-23T07:40:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed DHSV and bled of pressure above through PWV.", "dTimEnd": "2016-04-23T10:00:00+02:00", "dTimStart": "2016-04-23T09:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- test scsssv", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Inflow tested DHSV to 0.01 bar / 30 min .", "dTimEnd": "2016-04-23T11:45:00+02:00", "dTimStart": "2016-04-23T10:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- test scsssv", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed HMV and purged lubricator through XT-cross with N2.", "dTimEnd": "2016-04-23T12:15:00+02:00", "dTimStart": "2016-04-23T11:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed tool-box talk prior to L/D BHA on drillfloor.", "dTimEnd": "2016-04-23T12:35:00+02:00", "dTimStart": "2016-04-23T12:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator. L/D BHA on drillfloor.", "dTimEnd": "2016-04-23T13:10:00+02:00", "dTimStart": "2016-04-23T12:35:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D upper lubricator section and GIH to catwalk.", "dTimEnd": "2016-04-23T13:40:00+02:00", "dTimStart": "2016-04-23T13:10:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed tool-box talk prior to lifting riser of well.", "dTimEnd": "2016-04-23T13:45:00+02:00", "dTimStart": "2016-04-23T13:40:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected and lifted lower lubricator section above WL BOP to drillfloor. Lifted WL BOP from hatchdeck to PCE container. Lifted riser to cantilever deck.", "dTimEnd": "2016-04-23T14:40:00+02:00", "dTimStart": "2016-04-23T13:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed top cap and KW cap. Rewound all BOP and PCE hoses.\nInstalled permanent hatch.", "dTimEnd": "2016-04-23T16:15:00+02:00", "dTimStart": "2016-04-23T14:40:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Leak tested top cap and KW cap to 20/345 bar for 5/10 min. \nMeanwhile: Split lubricator on drillfloor.", "dTimEnd": "2016-04-23T17:45:00+02:00", "dTimStart": "2016-04-23T16:15:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Checked valve status with production operator and cleaned wellhead area. Prepared handover documention and handed well back to production dep.", "dTimEnd": "2016-04-23T18:45:00+02:00", "dTimStart": "2016-04-23T17:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Packed equipment and prepared for backload.", "dTimEnd": "2016-04-24T00:00:00+02:00", "dTimStart": "2016-04-23T18:45:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_04_25
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-04-24T00:00:00+02:00
2016-04-25T00:00:00+02:00
normal
2018-05-03T13:51:41+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-04-25T00:00:00+02:00", "dTimDiaHoleStart": "2016-04-20T06:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "End of operation", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "0", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "10", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "Packed equipment. Cleaned workspace. Demobilized personell.", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Packed equipment and prepared for backload. Cleaned drillfloor and cantilever.", "dTimEnd": "2016-04-24T11:00:00+02:00", "dTimStart": "2016-04-24T00:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed are inspection with barge engineer. Cleaned and tidied offices and workspace. Demobilized all personell. \n*** End of operation ***", "dTimEnd": "2016-04-24T17:00:00+02:00", "dTimStart": "2016-04-24T11:00:00+02:00", "md": "0", "phase": "wire line", "proprietaryCode": "workover -- wire line", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_19
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-18T00:00:00+02:00
2016-09-19T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-19T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- Finish R/U and testing WL well control equipment\n- Bullhead hydrocarbons into the well\n- Install and test deep set barrier plug\n- M/U WL cutter BHA and RIH", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "1", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- Skidded cantilever onto slot F-11\n- R/U WL equipment\n- Attempted to pressure test lower WL riser and WL BOP", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Performed prejob meeting to skid cantilever", "dTimEnd": "2016-09-18T06:00:00+02:00", "dTimStart": "2016-09-18T05:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Skidded cantilever onto F-11 slot, 3m to starboard", "dTimEnd": "2016-09-18T06:30:00+02:00", "dTimStart": "2016-09-18T06:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed after skid jobs and cleared in moon pool area", "dTimEnd": "2016-09-18T07:00:00+02:00", "dTimStart": "2016-09-18T06:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed production flow line from F11B. Meanwhile L/D HPDR to cantilever, R/D diverter chains and installed elevators, spotted WL equipment on rig floor, prepared for R/U manifolds and hoses to XT", "dTimEnd": "2016-09-18T12:00:00+02:00", "dTimStart": "2016-09-18T07:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued with preparations and R/U WL (started to R/U and check chicksan manifolds) . Meanwhile pressure tested blind flange on production wing valve", "dTimEnd": "2016-09-18T13:00:00+02:00", "dTimStart": "2016-09-18T12:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed the fox hole and started to lower the wire line BOP into moon pool, continued with R/U chicksan manifolds on X-mas tree.", "dTimEnd": "2016-09-18T15:00:00+02:00", "dTimStart": "2016-09-18T13:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U top hatches in the moon pool. Meanwhile continued with lowering the WL BOP and positioning in moon pool. Lowered hoses down to WL BOP", "dTimEnd": "2016-09-18T18:00:00+02:00", "dTimStart": "2016-09-18T15:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to remove XT cap and install lower riser and WL BOP", "dTimEnd": "2016-09-18T18:15:00+02:00", "dTimStart": "2016-09-18T18:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed XT cap and installed lower riser", "dTimEnd": "2016-09-18T19:30:00+02:00", "dTimStart": "2016-09-18T18:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to install WL BOP", "dTimEnd": "2016-09-18T19:45:00+02:00", "dTimStart": "2016-09-18T19:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted and installed WL BOP, installed hoses", "dTimEnd": "2016-09-18T21:30:00+02:00", "dTimStart": "2016-09-18T19:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested bleed off manifold. 20/345bar 5/10 min. Meanwhile P/U WL riser, performed housekeeping on rig floor, performed maintenance on gas trap in shaker", "dTimEnd": "2016-09-18T23:00:00+02:00", "dTimStart": "2016-09-18T21:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to pressure test lower riser and WL BOP. Observed leak in the connection between lower riser and XT. Drained riser and lifted lower riser and WL BOP from XT. Secured work place. Inspected connection. Observed scratches on the internal sealing face on the XT side", "dTimEnd": "2016-09-19T00:00:00+02:00", "dTimStart": "2016-09-18T23:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_20
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-19T00:00:00+02:00
2016-09-20T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-20T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- Set deep set barrier plug. Pressure test and inflow test same\n- Cut tubing above production packer\n- Set shallow set barrier plug, test same", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "2", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- R/U WL pressure control equipment \n- Bullheaded sea water into the well\n- RIH w/ deep set barrier plug", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Evaluated situation. Located replacement X-over on F-04 well. Meanwhile opened BOP on stump and serviced drilling equipment", "dTimEnd": "2016-09-19T02:00:00+02:00", "dTimStart": "2016-09-19T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited for production to prepare paperwork, isolate F-4 and bleed off pressure below tree cap. Meanwhile removed damaged X-over from F-11B XT. Built lubricator on rig floor", "dTimEnd": "2016-09-19T04:00:00+02:00", "dTimStart": "2016-09-19T02:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to disconnect tree cap from X-over on F-4. No-go. Meanwhile opened and inspected BOP for cement", "dTimEnd": "2016-09-19T07:00:00+02:00", "dTimStart": "2016-09-19T04:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed X-over from the XT and moved same to welders shop to attempt to release tree cap from X-over", "dTimEnd": "2016-09-19T07:30:00+02:00", "dTimStart": "2016-09-19T07:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Release tree can from the X-over in the welders shop with help of heating", "dTimEnd": "2016-09-19T09:30:00+02:00", "dTimStart": "2016-09-19T07:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed X-over on XT on F-11B well", "dTimEnd": "2016-09-19T10:00:00+02:00", "dTimStart": "2016-09-19T09:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed lower riser and WL BOP on XT", "dTimEnd": "2016-09-19T10:30:00+02:00", "dTimStart": "2016-09-19T10:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to pressure test of bleed off manifold and connection on WL lower riser to XT, 20/345bar 5/10 min. Observed leak on bleed off manifold", "dTimEnd": "2016-09-19T11:30:00+02:00", "dTimStart": "2016-09-19T10:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot leak on bleed off manifold", "dTimEnd": "2016-09-19T12:15:00+02:00", "dTimStart": "2016-09-19T11:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pressure test of bleed off manifold and connection on WL lower riser to XT, 20/345bar 5/10 min", "dTimEnd": "2016-09-19T12:45:00+02:00", "dTimStart": "2016-09-19T12:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to install riser and lubricator", "dTimEnd": "2016-09-19T13:00:00+02:00", "dTimStart": "2016-09-19T12:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed cover under WL BOP. Installed riser", "dTimEnd": "2016-09-19T13:45:00+02:00", "dTimStart": "2016-09-19T13:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed handling equipment. Installed WL lift equipment", "dTimEnd": "2016-09-19T14:00:00+02:00", "dTimStart": "2016-09-19T13:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted lubricator, M/U setting tool. Moved safety pin in sheave under elevator", "dTimEnd": "2016-09-19T15:15:00+02:00", "dTimStart": "2016-09-19T14:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed lubricator, M/U plug BHA", "dTimEnd": "2016-09-19T15:45:00+02:00", "dTimStart": "2016-09-19T15:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Filled riser and lubricator with 50/50 MEG. Pressure tested WL rig up to 20/345 bar 5/10 min using cement pump", "dTimEnd": "2016-09-19T16:45:00+02:00", "dTimStart": "2016-09-19T15:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to bullhead well to sea water", "dTimEnd": "2016-09-19T17:00:00+02:00", "dTimStart": "2016-09-19T16:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed SV, opened HMV. Pressured up DHSV control line to 520bar. Confirmed line up. Pumped 3m3 of 50/50 MEG w/ cement unit.", "dTimEnd": "2016-09-19T17:15:00+02:00", "dTimStart": "2016-09-19T17:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/U to rig pump. Pumped 10 m3 wash pill w/ 1200 l/min - 124 bar", "dTimEnd": "2016-09-19T17:45:00+02:00", "dTimStart": "2016-09-19T17:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Bullheaded 249 m3 sea water w/ 1300 l/min - 120 bar. Standpipe pressure slowly decreased and stabilised at 68 bar. Stopped pumps, SIWHP 35bar. Meanwhile performed TBT to RIH w/ deepset barrier plug", "dTimEnd": "2016-09-19T21:00:00+02:00", "dTimStart": "2016-09-19T17:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pumped 10m3 50/50 MEG w/ cement pump, 1300l/min - 80bar. Closed KV on XT", "dTimEnd": "2016-09-19T21:15:00+02:00", "dTimStart": "2016-09-19T21:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Equalized and opened SV. RIH w/ run #4, deep set barrier plug to 2838 m. Average running speed 35 m/min. Tool string stopped at 2838 m", "dTimEnd": "2016-09-19T23:45:00+02:00", "dTimStart": "2016-09-19T21:15:00+02:00", "md": "2838", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from to 2700 m", "dTimEnd": "2016-09-20T00:00:00+02:00", "dTimStart": "2016-09-19T23:45:00+02:00", "md": "2700", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_21
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-20T00:00:00+02:00
2016-09-21T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-21T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- R/D WL pressure control equipment\n- N/D XT and spacer spool\n- N/U HP riser and BOP", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "3", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- Installed deepset barrier plug. Pressure tested and inflow tested same\n- Cut 7in tubing above production packer\n- Instaled shallow set barrier plug. Pressure tested same\n- Started R/D WL pressure control equipment", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "RIH from 2700m. Tool string stopped at 2876m. POOH and RIH several times, worked gradually down to setting depth.", "dTimEnd": "2016-09-20T02:00:00+02:00", "dTimStart": "2016-09-20T00:00:00+02:00", "md": "3083", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated BHA across interval 3030 - 3092 m . Set plug with mid packer element at 3083 m . Lost 300 lbs of weight after setting sequence was complete. Tagged plug", "dTimEnd": "2016-09-20T02:30:00+02:00", "dTimStart": "2016-09-20T02:00:00+02:00", "md": "3083", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 3083 m to 0 m . Average pulling speed 35 m/min", "dTimEnd": "2016-09-20T04:15:00+02:00", "dTimStart": "2016-09-20T02:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested ME550-700 plug and SV to 20/265bar for 5/10min. Bled off pressure in tubing to 10bar to closed drain. Inflow tested deepset barrier plug for 30 min. Ok. Bled off remaining pressure in tubing to closed drain. Meanwhile continued to pressure test BOP.", "dTimEnd": "2016-09-20T07:30:00+02:00", "dTimStart": "2016-09-20T04:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to R/D BHA (run#4)", "dTimEnd": "2016-09-20T07:45:00+02:00", "dTimStart": "2016-09-20T07:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke lubricator and L/D BHA (run#4). Meanwhile serviced drilling equipment and continued with testing BOP", "dTimEnd": "2016-09-20T08:15:00+02:00", "dTimStart": "2016-09-20T07:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Built new cablehead.", "dTimEnd": "2016-09-20T09:00:00+02:00", "dTimStart": "2016-09-20T08:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U BHA, tested DECT cutter and connected cable head. Installed lubricator", "dTimEnd": "2016-09-20T10:00:00+02:00", "dTimStart": "2016-09-20T09:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Leak tested QTS to 20/345 bar for 5/10 min. Bleed down well pressure from 32bar to 1 bar. Opened SV", "dTimEnd": "2016-09-20T11:00:00+02:00", "dTimStart": "2016-09-20T10:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ cutter BHA (run #5), to 3065 m. Running speed 35 m/min.", "dTimEnd": "2016-09-20T12:45:00+02:00", "dTimStart": "2016-09-20T11:00:00+02:00", "md": "3065", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated across interval 3004 - 3065 m . Positioned cutter at 3055 m. Performed cut, tubing in compression. Tool stalled out. Retracted anchors", "dTimEnd": "2016-09-20T14:00:00+02:00", "dTimStart": "2016-09-20T12:45:00+02:00", "md": "3048", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with W/L . Average pulling speed 35 m/min", "dTimEnd": "2016-09-20T15:30:00+02:00", "dTimStart": "2016-09-20T14:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed SV and leak tested tree/cross to 345 bar.", "dTimEnd": "2016-09-20T16:30:00+02:00", "dTimStart": "2016-09-20T15:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke off lubricator and L/D tool string", "dTimEnd": "2016-09-20T17:30:00+02:00", "dTimStart": "2016-09-20T16:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U tool string w/ 572-700 ME plug (run#6), installed lubricator. Pressure tested QTS to 20/345 bar for 5/10 min. Ok", "dTimEnd": "2016-09-20T18:45:00+02:00", "dTimStart": "2016-09-20T17:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/U to pressure up tubing. Pressured up tubing to confirm cut. Pressure went up to +/- 90 bar, then dropped to 1 bar. Observed 0.5 bar increase in annulus pressure. Continued to pump slowly with cement unit down tubing. Pressure increased both in tubing and annulus which indicated communication to annulus. Stopped pumping w/ +/- 9 bar in well. Bled off tubing pressure to 3 bar and open SV .", "dTimEnd": "2016-09-20T20:15:00+02:00", "dTimStart": "2016-09-20T18:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ shallow set plug (run#6) to 256 m. Average running speed 35 m/min.", "dTimEnd": "2016-09-20T20:30:00+02:00", "dTimStart": "2016-09-20T20:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Correlated BHA across interval 229 - 276 m . Set plug with mid packer element at 246 m. P/U weight before/after setting 884/484 lbs. Tagged plug", "dTimEnd": "2016-09-20T21:00:00+02:00", "dTimStart": "2016-09-20T20:30:00+02:00", "md": "276", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 246 m to 0 m . Average pulling speed 35 m/min. Confirmed tool string in tool catcher and closed SV .Meanwhile held TBT for pressure testing shallow plug", "dTimEnd": "2016-09-20T21:30:00+02:00", "dTimStart": "2016-09-20T21:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up and tested shallow set barrier plug to 20bar/300bar for 5/10min. Bled off pressure to closed drain. Meanwhile TBT for rigging down wireline", "dTimEnd": "2016-09-20T22:15:00+02:00", "dTimStart": "2016-09-20T21:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drained lubricator and riser and purged w/ N2. Meanwhile disconnected WL BOP hoses", "dTimEnd": "2016-09-20T23:00:00+02:00", "dTimStart": "2016-09-20T22:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D lubricator, tool string, R/D sheaves", "dTimEnd": "2016-09-21T00:00:00+02:00", "dTimStart": "2016-09-20T23:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_22
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-21T00:00:00+02:00
2016-09-22T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-22T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- Pump open shallow set barrier plug\n- Retrieve TH and 500m of tubing \n- RIH w/ tubing on spear and place balanced cement plug in 9 5/8in casing\n", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "4", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- Finished R/D WL \n- N/D X-tree and spacer spool\n- N/U HP riser and BOP, performed connector test\n- R/U casing handling equipment \n- RIH w/ THRT", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "R/D WL riser above BOP, L/D same", "dTimEnd": "2016-09-21T00:30:00+02:00", "dTimStart": "2016-09-21T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/D WL BOP and lower riser joint. Removed all WL equipment from rig floor and moon pool. Pulled fox hole to be able to lift WL BOP from moon pool. Lifted WL BOP from the moon pool to the pipe deck", "dTimEnd": "2016-09-21T03:30:00+02:00", "dTimStart": "2016-09-21T00:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting to remove hatches. Meanwhile removed BX elevator and installed chains in bails", "dTimEnd": "2016-09-21T03:45:00+02:00", "dTimStart": "2016-09-21T03:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed split hatch on F-11. Removed hatch on adjacent well. Removed beam", "dTimEnd": "2016-09-21T04:15:00+02:00", "dTimStart": "2016-09-21T03:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to remove X-tree and AAR for WL operation", "dTimEnd": "2016-09-21T04:30:00+02:00", "dTimStart": "2016-09-21T04:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed lifting cap w/ tugger. Meanwhile performed pressure tests of kill/choke manifolds", "dTimEnd": "2016-09-21T04:45:00+02:00", "dTimStart": "2016-09-21T04:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed master bushing and outer ring. Meanwhile performed pressure tests of kill/choke manifolds", "dTimEnd": "2016-09-21T05:00:00+02:00", "dTimStart": "2016-09-21T04:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lowered diverter chains on TDS bails to wellhead and attached to X-tree with double securing. Took weight as per lifting plan and removed Grayloc clamp. Meanwhile performed pressure tests of kill/choke manifolds", "dTimEnd": "2016-09-21T05:30:00+02:00", "dTimStart": "2016-09-21T05:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted X-tree to moon pool. Transfered load to gantry crane in moon pool. Meanwhile performed pressure tests of kill/choke manifolds", "dTimEnd": "2016-09-21T06:15:00+02:00", "dTimStart": "2016-09-21T05:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attached lifting arrangement from TDS to Spacer spool. Lifted same to rig floor. Meanwhile performed pressure tests of kill/choke manifolds", "dTimEnd": "2016-09-21T06:45:00+02:00", "dTimStart": "2016-09-21T06:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed outer ring and MB. Meanwhile Landed X-tree on skid and started to make up Grayloc clamp. Meanwhile performed pressure tests of kill/choke manifolds", "dTimEnd": "2016-09-21T07:00:00+02:00", "dTimStart": "2016-09-21T06:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to install hatches in moon pool", "dTimEnd": "2016-09-21T07:15:00+02:00", "dTimStart": "2016-09-21T07:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to M/U X-tree to bracket. Installed fox hole. Installed hatches in moon pool, prepared to test TDS.", "dTimEnd": "2016-09-21T08:45:00+02:00", "dTimStart": "2016-09-21T07:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed communication collar on well head using tugger line from rig floor. Meanwhile P/U riser from cantilever", "dTimEnd": "2016-09-21T11:00:00+02:00", "dTimStart": "2016-09-21T08:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lowered HP riser to well head M/U same, installed master bushing and covers in moon pool", "dTimEnd": "2016-09-21T11:15:00+02:00", "dTimStart": "2016-09-21T11:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Built scaffolding in moon pool for BOP/NT2 connector. Meanwhile pressure tested TDS", "dTimEnd": "2016-09-21T12:45:00+02:00", "dTimStart": "2016-09-21T11:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted BOP from stump and skidded same F-11", "dTimEnd": "2016-09-21T13:15:00+02:00", "dTimStart": "2016-09-21T12:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot Bop lifter , sensor fault on test stump", "dTimEnd": "2016-09-21T13:45:00+02:00", "dTimStart": "2016-09-21T13:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Landed BOP on stump and M/U NT2 connector. Installed tension cylinder. Meanwhile drifted pipe in derrick", "dTimEnd": "2016-09-21T16:15:00+02:00", "dTimStart": "2016-09-21T13:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed master bushing and installed slick joint and diverter. M/U bolts on slick joint, and removed lift gear on diverter", "dTimEnd": "2016-09-21T18:00:00+02:00", "dTimStart": "2016-09-21T16:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressured up diverter system, meanwhile drop checked on BOP and carried out housekeeping in moon pool", "dTimEnd": "2016-09-21T18:15:00+02:00", "dTimStart": "2016-09-21T18:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Filled the well with sea water, using Trip tank", "dTimEnd": "2016-09-21T18:30:00+02:00", "dTimStart": "2016-09-21T18:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested connection on BOP and riser to 20/300 bar for 5/10min against shallow set plug", "dTimEnd": "2016-09-21T19:00:00+02:00", "dTimStart": "2016-09-21T18:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cleaned and cleared rig floor", "dTimEnd": "2016-09-21T19:30:00+02:00", "dTimStart": "2016-09-21T19:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lifted casing tong to rig floor. Meanwhile broke out FOSV from side entry assembly for testing offline", "dTimEnd": "2016-09-21T20:30:00+02:00", "dTimStart": "2016-09-21T19:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to R/U casing tong", "dTimEnd": "2016-09-21T20:45:00+02:00", "dTimStart": "2016-09-21T20:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U casing tong", "dTimEnd": "2016-09-21T21:45:00+02:00", "dTimStart": "2016-09-21T20:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to P/U THRT", "dTimEnd": "2016-09-21T22:00:00+02:00", "dTimStart": "2016-09-21T21:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U THRT. Reconfigured pups in the string for space out", "dTimEnd": "2016-09-21T22:45:00+02:00", "dTimStart": "2016-09-21T22:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot issues w/ casing tong, unable to B/O connection. Removed tong tension level and grinded same", "dTimEnd": "2016-09-21T23:30:00+02:00", "dTimStart": "2016-09-21T22:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to P/U and M/U tubingTHRT. POOH, installed control lines and inspected THRT", "dTimEnd": "2016-09-22T00:00:00+02:00", "dTimStart": "2016-09-21T23:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_23
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-22T00:00:00+02:00
2016-09-23T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-23T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- Place balanced cement plug in 9 5/8in casing\n- Pull and L/D 600m of tubing\n- RIH w/ tubing on spear and leave tubing in the well\n- Retrieve MS-T seal assy\n", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "5", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- Landed and engaged THRT\n- Pumped open shallow set barrier plug\n- Retrieved TH and 500m of tubing \n- RIH w/ tubing, circulated well clean to sea water", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "RIH and landed off THRT, engaged tool and confirmed w/ 2t overpull", "dTimEnd": "2016-09-22T00:15:00+02:00", "dTimStart": "2016-09-22T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Applied pressure to shear pin and then rotated string 8x turns CCW into communication collar", "dTimEnd": "2016-09-22T00:30:00+02:00", "dTimStart": "2016-09-22T00:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to pump open ME shallow set barrier plug", "dTimEnd": "2016-09-22T00:45:00+02:00", "dTimStart": "2016-09-22T00:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Dropped 2in steel ball in the well, installed swedge to Fig. 1502 connection, installed LTV and cement hose", "dTimEnd": "2016-09-22T01:15:00+02:00", "dTimStart": "2016-09-22T00:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested cement hose and LTV to 20/345bar for 5/10 min. Confirmed line up", "dTimEnd": "2016-09-22T01:45:00+02:00", "dTimStart": "2016-09-22T01:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Checked annulus pressure at wellhead 10bar. Started to pressure up tubing w/ cement unit with constant rate. Observed pressure drop after reaching 28 bar indicating that plug opened. Stopped pumping, pressure in tubing stabilized at 13 bar. Annulus pressure at wellhead went up and stabilized to 13 bar.", "dTimEnd": "2016-09-22T02:00:00+02:00", "dTimStart": "2016-09-22T01:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Bled off tubing pressure above DHSV to zero and monitored for buildup, no build up observed. Applied 520bar to the control line to open DHSV. Pressured up well w/ cementing unit. Observed indications of equalizing and openning of DHSV both on cement unit and on pressure gauge on control fluid pump. Stopped pumping. Bled off well to zero pressure. Annulus pressure 2 bar. No indications of gas below DHSV/in the well observed. Confirmed zero pressure below DHSV. Closed DHSV", "dTimEnd": "2016-09-22T02:30:00+02:00", "dTimStart": "2016-09-22T02:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RD swedge, LTV and cement hose. Meanwhile held TBT for pulling tubing hanger free", "dTimEnd": "2016-09-22T03:00:00+02:00", "dTimStart": "2016-09-22T02:30:00+02:00", "md": "3055", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressured upTHRT line to 2000psi and then bled down to 500 psi to release TH", "dTimEnd": "2016-09-22T03:15:00+02:00", "dTimStart": "2016-09-22T03:00:00+02:00", "md": "3055", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U to 166t , neutral weight, continued to P/U to 170t, TH released (5t overpull). Continued to POOH, observed +/- 20t drag, disconnected control hoses, RIH before start breaking and L/D landing string", "dTimEnd": "2016-09-22T03:45:00+02:00", "dTimStart": "2016-09-22T03:15:00+02:00", "md": "3055", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D landing string and THRT. Meanwhile held TBT for installing power slips and control line reel", "dTimEnd": "2016-09-22T04:45:00+02:00", "dTimStart": "2016-09-22T03:45:00+02:00", "md": "3034", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed power slips and positioned control line reel", "dTimEnd": "2016-09-22T05:45:00+02:00", "dTimStart": "2016-09-22T04:45:00+02:00", "md": "3034", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ 7in tubing from 3034m 3002m", "dTimEnd": "2016-09-22T06:30:00+02:00", "dTimStart": "2016-09-22T05:45:00+02:00", "md": "3002", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Repaired hydraulic hose for Flush mounted slips", "dTimEnd": "2016-09-22T07:00:00+02:00", "dTimStart": "2016-09-22T06:30:00+02:00", "md": "3002", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to pull tubing", "dTimEnd": "2016-09-22T07:15:00+02:00", "dTimStart": "2016-09-22T07:00:00+02:00", "md": "3002", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued pulling tubing from 3065m to 2833m. Average pulling speed 4,5 joints/hour", "dTimEnd": "2016-09-22T10:45:00+02:00", "dTimStart": "2016-09-22T07:15:00+02:00", "md": "2833", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed box protector on joint 239 w/ ME plug inside. Used crane to lay it out", "dTimEnd": "2016-09-22T11:00:00+02:00", "dTimStart": "2016-09-22T10:45:00+02:00", "md": "2833", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued pulling tubing from 2833m to 2608m. Average pulling speed 7 joints/hour", "dTimEnd": "2016-09-22T13:45:00+02:00", "dTimStart": "2016-09-22T11:00:00+02:00", "md": "2608", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed control line from DHSV, secured same on drum. L/D DHSV using crane. Observed back flow from well. Trip tank static. Waited for backflow to decrease", "dTimEnd": "2016-09-22T14:30:00+02:00", "dTimStart": "2016-09-22T13:45:00+02:00", "md": "2589", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U swedge to casing. Moved control line drum from drill floor", "dTimEnd": "2016-09-22T15:15:00+02:00", "dTimStart": "2016-09-22T14:30:00+02:00", "md": "2589", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/D casing tong. Installed clamp on pipe for control line", "dTimEnd": "2016-09-22T15:45:00+02:00", "dTimStart": "2016-09-22T15:15:00+02:00", "md": "2589", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed handling gear to RIH w/ 5,5in DP", "dTimEnd": "2016-09-22T16:00:00+02:00", "dTimStart": "2016-09-22T15:45:00+02:00", "md": "2589", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cleaned and cleared rig floor", "dTimEnd": "2016-09-22T16:15:00+02:00", "dTimStart": "2016-09-22T16:00:00+02:00", "md": "2589", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot and changed linear transducer on Iron roughneck. Meanwhile built pump in tee and M/U pup joints in fox hole", "dTimEnd": "2016-09-22T17:15:00+02:00", "dTimStart": "2016-09-22T16:15:00+02:00", "md": "2589", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Started RIH from 2589m. Adjusted clamp, M/U 1st stand", "dTimEnd": "2016-09-22T17:45:00+02:00", "dTimStart": "2016-09-22T17:15:00+02:00", "md": "2549", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed casing slips and installed slips for DP", "dTimEnd": "2016-09-22T18:15:00+02:00", "dTimStart": "2016-09-22T17:45:00+02:00", "md": "2549", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued RIH with back flow to 3050m. M/U TDS on all stands. Average RIH speed 215m/hour", "dTimEnd": "2016-09-22T20:30:00+02:00", "dTimStart": "2016-09-22T18:15:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Circulated SW w/ 3000 l/min - 155bar. Observed high reading of CO of 90ppm on portable gas sensors in shacker room. Returns OIW was over 100ppm, visually dirty", "dTimEnd": "2016-09-22T21:15:00+02:00", "dTimStart": "2016-09-22T20:30:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Stopped pumps, lined up to take returns to MGS, circulated w/ 1000l/min - 34bar. Confirmed zero gas readings", "dTimEnd": "2016-09-22T22:30:00+02:00", "dTimStart": "2016-09-22T21:15:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened BOP, resumed circulation w/ 3000 l/min - 155bar. Confirmed OIW content below 30ppm after total of 193m3 circulated", "dTimEnd": "2016-09-22T23:30:00+02:00", "dTimStart": "2016-09-22T22:30:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pumped wash pill of 20m3, 3000 l/min - 150 bar", "dTimEnd": "2016-09-22T23:45:00+02:00", "dTimStart": "2016-09-22T23:30:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/B stand, P/U single and pump in assembly", "dTimEnd": "2016-09-23T00:00:00+02:00", "dTimStart": "2016-09-22T23:45:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_24
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-23T00:00:00+02:00
2016-09-24T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-24T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- POOH w/ spear\n- Retrieve MS-T seal assy\n- Cut 10 3/4in tieback casing\n- RIH w/ spear and pull \n- 10 3/4in tieback casing\n- Release tieback adapter\n- Retrieve tieback adapter\n- Punch below 10 3/4in subsea casing hanger", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": "2853", "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "6", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- Placed balanced cement plug in 9 5/8in casing\n- Pulled and L/D 600m of tubing\n- RIH w/ tubing on spear, tagged cement\n- Released spear and left tubing in the well\n\n", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Installed cementing hose, pressure tested same to 250bar for 3 min.", "dTimEnd": "2016-09-23T00:30:00+02:00", "dTimStart": "2016-09-23T00:00:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting for cement job", "dTimEnd": "2016-09-23T00:45:00+02:00", "dTimStart": "2016-09-23T00:30:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Balanced cement plug (3050 m - 2850 m ): Mixed and pumped 9,2 m3 of 1,9 SG cement slurry, 600 l/min. Displaced the cement to the rig floor with 2900 l of drill water. Zeroed volume counters. Displaced the cement with 46 m3 (2076 strokes) of SW, 2000 l/min/ 40 bar. Pulled out of cement to 2850m at 4 min/stand. Theoretical TOC 2850 m MD.", "dTimEnd": "2016-09-23T02:00:00+02:00", "dTimStart": "2016-09-23T00:45:00+02:00", "md": "3050", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed sponge ball. Pumped 10m3 hi-vis at 1700l/min / 65 bar. Circulated 3000 l/min/ 140 bar. Held TBT for P/U BOP wash tool", "dTimEnd": "2016-09-23T04:15:00+02:00", "dTimStart": "2016-09-23T02:00:00+02:00", "md": "2850", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH and R/B 1x stand. Installed closed FOSV and BOP wash tool, made 10x passes in BOP and well head at 1500 LPM / 12 bar, operated rams and annular once", "dTimEnd": "2016-09-23T06:00:00+02:00", "dTimStart": "2016-09-23T04:15:00+02:00", "md": "2800", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 2829m to 2550m. Average pulling speed 280m/hour", "dTimEnd": "2016-09-23T07:00:00+02:00", "dTimStart": "2016-09-23T06:00:00+02:00", "md": "2550", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to R/U casing handling equipment", "dTimEnd": "2016-09-23T07:15:00+02:00", "dTimStart": "2016-09-23T07:00:00+02:00", "md": "2550", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed dril pipe slips, installed casing slips. Removed CL clamp", "dTimEnd": "2016-09-23T08:00:00+02:00", "dTimStart": "2016-09-23T07:15:00+02:00", "md": "2550", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U casing tong", "dTimEnd": "2016-09-23T09:00:00+02:00", "dTimStart": "2016-09-23T08:00:00+02:00", "md": "2550", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke off swedge. Changed handling equipment in elevator. M/U FOSV to swedge", "dTimEnd": "2016-09-23T09:30:00+02:00", "dTimStart": "2016-09-23T09:00:00+02:00", "md": "2550", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with 7in tubing from 2550m to 1944m. Average pulling speed 8,2 joints/hour", "dTimEnd": "2016-09-23T15:45:00+02:00", "dTimStart": "2016-09-23T09:30:00+02:00", "md": "1944", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to R/D casing handling equipment", "dTimEnd": "2016-09-23T16:00:00+02:00", "dTimStart": "2016-09-23T15:45:00+02:00", "md": "1944", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/D casing handling equipment. Cleaned and cleared rig floor", "dTimEnd": "2016-09-23T17:15:00+02:00", "dTimStart": "2016-09-23T16:00:00+02:00", "md": "1944", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Serviced PRSs", "dTimEnd": "2016-09-23T17:45:00+02:00", "dTimStart": "2016-09-23T17:15:00+02:00", "md": "1944", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Located and repaired/changed leaking hose on aft PRS", "dTimEnd": "2016-09-23T21:00:00+02:00", "dTimStart": "2016-09-23T17:45:00+02:00", "md": "1944", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and B/O FOSV from tubing swedge", "dTimEnd": "2016-09-23T21:15:00+02:00", "dTimStart": "2016-09-23T21:00:00+02:00", "md": "1944", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U spear assembly (run #11) and engaged into 7in tubing at RKB. RIH on DP from 1944m to 1978m", "dTimEnd": "2016-09-23T21:45:00+02:00", "dTimStart": "2016-09-23T21:15:00+02:00", "md": "1978", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed master bushings and install DP slips", "dTimEnd": "2016-09-23T22:00:00+02:00", "dTimStart": "2016-09-23T21:45:00+02:00", "md": "1978", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to RIH w/ tubing on spear from 1978m to 2810m. Average running speed 832m/hour. Meanwhile carried out TBT for pressure testing rig up of pumping lines to X-mas tree for slop injection", "dTimEnd": "2016-09-23T23:00:00+02:00", "dTimStart": "2016-09-23T22:00:00+02:00", "md": "2810", "phase": "fixed", "proprietaryCode": "plug abandon -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U TDS and washed down with 550 l/min - 15bar from 2810m, tagged TOC at 2853.4m w/ 10t. Release spear from tubing by rotating 2x turns clockwise. Top of tubing left in the well at 909m. Meanwhile prepared to test chicksan lines to X-mas tree on F-4", "dTimEnd": "2016-09-23T23:30:00+02:00", "dTimStart": "2016-09-23T23:00:00+02:00", "md": "2850", "phase": "fixed", "proprietaryCode": "plug abandon -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ spear BHA (run#11) on 5,5in DP from 909 m to 436 m . Avgerage tripping speed 950 m/hour", "dTimEnd": "2016-09-24T00:00:00+02:00", "dTimStart": "2016-09-23T23:30:00+02:00", "md": "436", "phase": "fixed", "proprietaryCode": "plug abandon -- trip", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_25
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-24T00:00:00+02:00
2016-09-25T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-25T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- Cut 9 5/8in casing\n- Mill 10 3/4in subsea casing hanger\n- Pull 10 3/4in casing to X-over, L/D same", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "7", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- POOH w/ spear\n- Retrieved MS-T seal assy\n- Cut 10 3/4in tieback casing\n- RIH w/ spear and pulled 10 3/4in tieback casing\n- Released and retrieved tieback adapter\n- Punched below 10 3/4in subsea casing hanger and ventilated annulus\n- M/U and RIH w/ cutter BHA to cut 9 5/8in casing", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued to POOH w/ spear BHA (run#11) on 5,5in DP from 436 m to 40 m . Avgerage tripping speed 800 m/hour", "dTimEnd": "2016-09-24T00:30:00+02:00", "dTimStart": "2016-09-24T00:00:00+02:00", "md": "40", "phase": "fixed", "proprietaryCode": "plug abandon -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled spear on surface. Inspected and R/B in derrick same", "dTimEnd": "2016-09-24T01:00:00+02:00", "dTimStart": "2016-09-24T00:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed DP slips and installed master bushing", "dTimEnd": "2016-09-24T01:15:00+02:00", "dTimStart": "2016-09-24T01:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U jetting tool and RIH to 20.6m", "dTimEnd": "2016-09-24T01:45:00+02:00", "dTimStart": "2016-09-24T01:15:00+02:00", "md": "20", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot pump control, unable to control mud pumps from rig floor due to PLC issue. Meanwhile carried out TBT for running pump local for jetting wellhead", "dTimEnd": "2016-09-24T02:15:00+02:00", "dTimStart": "2016-09-24T01:45:00+02:00", "md": "20", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Washed wellhead w/ 1500 l/min - 28 bar , 1360 strokes pumped", "dTimEnd": "2016-09-24T02:30:00+02:00", "dTimStart": "2016-09-24T02:15:00+02:00", "md": "20", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH and L/D jetting tool", "dTimEnd": "2016-09-24T02:45:00+02:00", "dTimStart": "2016-09-24T02:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U MS-T seal retrieval tool and tested same", "dTimEnd": "2016-09-24T04:00:00+02:00", "dTimStart": "2016-09-24T02:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH to 20.1m and engaged MS-T seal retrieval tool. Pulled seal free with 110t overpull", "dTimEnd": "2016-09-24T05:00:00+02:00", "dTimStart": "2016-09-24T04:00:00+02:00", "md": "20", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH from 20m and L/D MS-T seal and retrieval tool", "dTimEnd": "2016-09-24T05:15:00+02:00", "dTimStart": "2016-09-24T05:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U 10 3/4in cutter BHA (run#13)", "dTimEnd": "2016-09-24T05:45:00+02:00", "dTimStart": "2016-09-24T05:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ 10 3/4in cutter BHA (run#13) on 5,5in DP to 127 m cutting depth", "dTimEnd": "2016-09-24T06:15:00+02:00", "dTimStart": "2016-09-24T05:45:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Recorded parameters: 600 l/min - 125 bar, 400 l/min - 50 bar, 300 l/min - 25 bar, up/down weights 73t/69t", "dTimEnd": "2016-09-24T06:30:00+02:00", "dTimStart": "2016-09-24T06:15:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cut 10 3/4in tieback casing at 127m 400-600 l/min, 35-50 bar, 3-7 kNm", "dTimEnd": "2016-09-24T07:00:00+02:00", "dTimStart": "2016-09-24T06:30:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ 10 3/4in cutter BHA (run#13) on 5,5in DP, Inspected knives, ok, L/D BHA", "dTimEnd": "2016-09-24T07:30:00+02:00", "dTimStart": "2016-09-24T07:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U spear BHA (run#14), inspected same", "dTimEnd": "2016-09-24T07:45:00+02:00", "dTimStart": "2016-09-24T07:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ spear BHA and engaged spear in tieback casing. Pulled fish to surface", "dTimEnd": "2016-09-24T08:00:00+02:00", "dTimStart": "2016-09-24T07:45:00+02:00", "md": "107", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to R/U casing tong", "dTimEnd": "2016-09-24T08:15:00+02:00", "dTimStart": "2016-09-24T08:00:00+02:00", "md": "107", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Released spear from tieback casing fish. R/B spear in derrick", "dTimEnd": "2016-09-24T08:30:00+02:00", "dTimStart": "2016-09-24T08:15:00+02:00", "md": "107", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U casing handling equipment", "dTimEnd": "2016-09-24T09:45:00+02:00", "dTimStart": "2016-09-24T08:30:00+02:00", "md": "107", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to pull and L/D 10 3/4in casing", "dTimEnd": "2016-09-24T10:00:00+02:00", "dTimStart": "2016-09-24T09:45:00+02:00", "md": "107", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with 10 3/4in tieback casing from 107 m to 0 m", "dTimEnd": "2016-09-24T12:15:00+02:00", "dTimStart": "2016-09-24T10:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/D 10 3/4in casing handling equipment", "dTimEnd": "2016-09-24T13:00:00+02:00", "dTimStart": "2016-09-24T12:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed to left hand saver sub on TDS", "dTimEnd": "2016-09-24T14:15:00+02:00", "dTimStart": "2016-09-24T13:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U left hand torque tool with jet sub below (run#15). M/U torque to 67kNm, RIH same on left hand drill pipe from surface to 140m", "dTimEnd": "2016-09-24T15:15:00+02:00", "dTimStart": "2016-09-24T14:15:00+02:00", "md": "140", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U TDS to string and washed tieback adapter area w/ 1500 l/min - 12 bar", "dTimEnd": "2016-09-24T15:30:00+02:00", "dTimStart": "2016-09-24T15:15:00+02:00", "md": "140", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Engaged and released tieback adapter w/ 15 kNm", "dTimEnd": "2016-09-24T16:00:00+02:00", "dTimStart": "2016-09-24T15:30:00+02:00", "md": "140", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ left hand drill pipe from 140m to surface", "dTimEnd": "2016-09-24T16:15:00+02:00", "dTimStart": "2016-09-24T16:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed left hand saver sub", "dTimEnd": "2016-09-24T16:45:00+02:00", "dTimStart": "2016-09-24T16:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D torque tool", "dTimEnd": "2016-09-24T17:00:00+02:00", "dTimStart": "2016-09-24T16:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U spear BHA (run#16)", "dTimEnd": "2016-09-24T17:15:00+02:00", "dTimStart": "2016-09-24T17:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U saver sub to TDS", "dTimEnd": "2016-09-24T17:45:00+02:00", "dTimStart": "2016-09-24T17:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ spear to 129m, engage spear to tieback adapter fish", "dTimEnd": "2016-09-24T18:00:00+02:00", "dTimStart": "2016-09-24T17:45:00+02:00", "md": "129", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH slowly w/ fish on spear to surface", "dTimEnd": "2016-09-24T18:30:00+02:00", "dTimStart": "2016-09-24T18:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Released spear and L/D tieback adapter fish", "dTimEnd": "2016-09-24T19:00:00+02:00", "dTimStart": "2016-09-24T18:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/B spear BHA in the derrick. Meanwhile started step rate testing on F-4 well w/ cement unit", "dTimEnd": "2016-09-24T19:15:00+02:00", "dTimStart": "2016-09-24T19:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to handle perforation guns. Meanwhile changed handling gear", "dTimEnd": "2016-09-24T19:30:00+02:00", "dTimStart": "2016-09-24T19:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and RIH with perforation guns to 12m (run#17)", "dTimEnd": "2016-09-24T20:00:00+02:00", "dTimStart": "2016-09-24T19:30:00+02:00", "md": "12", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U wild single, 2x X-overs and firing head, M/U same", "dTimEnd": "2016-09-24T20:30:00+02:00", "dTimStart": "2016-09-24T20:00:00+02:00", "md": "24", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ perforation BHA to 145m bottom shot depth", "dTimEnd": "2016-09-24T20:45:00+02:00", "dTimStart": "2016-09-24T20:30:00+02:00", "md": "145", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed UPR, opened choke. Applied 10 bar on IBOP. Opened IBOP to confirm line up. Filled string. Opened UPR, Broke off TDS and dropped 1 3/8 ball in string. M/U TDS. Closed UPR and opened choke. Fired guns with 160 l/min - 137 bar. Top shot at 142m, bottom shot at 145m. Continued to circulate w/ 160l/min - 2 bar. No gas observed in returns", "dTimEnd": "2016-09-24T21:15:00+02:00", "dTimStart": "2016-09-24T20:45:00+02:00", "md": "145", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Increased pump rate to 1000l/min -12 bar. Observed only water in returns. Circulated 1x BU, gas reading close to 0ppm in fluid and no readings in air. Stoped pumps", "dTimEnd": "2016-09-24T21:45:00+02:00", "dTimStart": "2016-09-24T21:15:00+02:00", "md": "145", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Flowchecked well for 15 min through choke, stable. Meanwhile finished pumpin step rate insection test on F-4 well", "dTimEnd": "2016-09-24T22:00:00+02:00", "dTimStart": "2016-09-24T21:45:00+02:00", "md": "145", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ perforation BHA (run#17) from 145m to 28m", "dTimEnd": "2016-09-24T22:15:00+02:00", "dTimStart": "2016-09-24T22:00:00+02:00", "md": "28", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D perforation BHA (run#17). All shots fired", "dTimEnd": "2016-09-24T22:45:00+02:00", "dTimStart": "2016-09-24T22:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to P/U 9 5/8in casing cutter BHA (run#18)", "dTimEnd": "2016-09-24T23:00:00+02:00", "dTimStart": "2016-09-24T22:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U 9 5/8in casing cutter BHA (run#18)", "dTimEnd": "2016-09-24T23:15:00+02:00", "dTimStart": "2016-09-24T23:00:00+02:00", "md": "10", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ 9 5/8in casing cutter BHA (run#18) to 805m. Average tripping speed 1070m/hour", "dTimEnd": "2016-09-25T00:00:00+02:00", "dTimStart": "2016-09-24T23:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_26
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-25T00:00:00+02:00
2016-09-26T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-26T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- Finish puling 10 3/4in casing to X-over\n- Pull 9 5/8in casing \n- Install 14in EZSV (lower)\n- Cut 14in casing\n- Punch below 14in subsea casing hanger\n- RIH w/ 14in EZSV (upper)\n\n", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": "2853", "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "8", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- Cut 9 5/8in casing\n- Milled 10 3/4in subsea casing hanger\n- Fished 10 3/4in casing fish and secured on surface\n- Pulled 34 joints of 10 3/4in casing, L/D same", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued to RIH w/ 9 5/8in casing cutter BHA (run#18) from 805m to 885,5 m", "dTimEnd": "2016-09-25T00:15:00+02:00", "dTimStart": "2016-09-25T00:00:00+02:00", "md": "885", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U TDS, filled string, took parameters. 300l/min - 16 bar, 600 l/min - 80 bar", "dTimEnd": "2016-09-25T00:30:00+02:00", "dTimStart": "2016-09-25T00:15:00+02:00", "md": "885", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cut 9 5/8in casing at 885,5m w/ 300-400 l/min, 19-32 bar, 80rpm, 3-7 kNm. Observed good indications of cut: pressure dropped to 0 and reduction of torque. Measured gap of 90cm", "dTimEnd": "2016-09-25T01:00:00+02:00", "dTimStart": "2016-09-25T00:30:00+02:00", "md": "885", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed flowcheck. Observed losses of 1,6m3/hour. Losses soon stopped, totally lost of 0,3m3", "dTimEnd": "2016-09-25T01:30:00+02:00", "dTimStart": "2016-09-25T01:00:00+02:00", "md": "885", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ 9 5/8in casing cutter BHA (run#18) from 885 m to 10 m . Avg. tripping speed 580 m/hour. Meanwhile performed TBT to inject drilling slop in F-4. Started pumping preflush w/ 1000l/min - 145bar", "dTimEnd": "2016-09-25T02:45:00+02:00", "dTimStart": "2016-09-25T01:30:00+02:00", "md": "10", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D 9 5/8in casing cutter BHA (run#18)", "dTimEnd": "2016-09-25T03:00:00+02:00", "dTimStart": "2016-09-25T02:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting for drops inspection of TDS", "dTimEnd": "2016-09-25T03:15:00+02:00", "dTimStart": "2016-09-25T03:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Carried out TDS drops inspection and service. Meanwhile continued w/ drilling slop injection on F-4. Total preflush pumped of 70m3, started pumping drilling slop, Batch#1, 1000l/min - 145bar", "dTimEnd": "2016-09-25T03:45:00+02:00", "dTimStart": "2016-09-25T03:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U side entry assembly (used in last cement job) and B/O 2x pup joints", "dTimEnd": "2016-09-25T04:00:00+02:00", "dTimStart": "2016-09-25T03:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to P/U 12,25 milling BHA (run#19)", "dTimEnd": "2016-09-25T04:15:00+02:00", "dTimStart": "2016-09-25T04:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U 12,25in milling BHA (run#19). Meanwhile continued w/ drilling slop injection on F-4. Total drilling slop pumped of 93m3 (batch#1), started pumping postflush, 1000l/min - 146bar", "dTimEnd": "2016-09-25T06:15:00+02:00", "dTimStart": "2016-09-25T04:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ 12,25in milling BHA (run#19) to 135 m", "dTimEnd": "2016-09-25T06:30:00+02:00", "dTimStart": "2016-09-25T06:15:00+02:00", "md": "135", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Recorded parameters: 400l/min - 2bar, 1300l/min - 6bar, 2000l/min - 9bar, 80rpm - 2-5kNm, weights up/down - 22t/15t. Tagged top of 10 3/4in subsea casing hanger at 139.7m. Meanwhile finished w/ pumping postflush after batch#1 of drilling slop on F-4. Total postflush pumped of 140m3 (after batch#1), 1000l/min - 150bar. Stopped injection for 2 hours", "dTimEnd": "2016-09-25T06:45:00+02:00", "dTimStart": "2016-09-25T06:30:00+02:00", "md": "140", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Milled 10 3/4in subsea casing hanger from 140.1 to 140.4 meter. 1500-2000l/min, 11Bar, 60-120rpm, max 25 kNm, WOB 1-8t. Observed good indications of break through: reduction of torque and WOB. Meanwhile continued w/ pumping drilling slop batch#2 on F-4. Total preflush pumped of 70m3 (before batch#2), started pumping drilling slop, Batch#2, 1000l/min - 150bar", "dTimEnd": "2016-09-25T13:15:00+02:00", "dTimStart": "2016-09-25T06:45:00+02:00", "md": "140", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Run down and tagged top of 10 3/4in casing stump at 142.1m. Dressed off top of stump +/- 5 cm, 80-100rpm, 4t WOB, 2-4kNm, 2000l/min - 9bar", "dTimEnd": "2016-09-25T14:00:00+02:00", "dTimStart": "2016-09-25T13:15:00+02:00", "md": "140", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled up above casing hanger area and circulated 2x BU @ 3000 l/min - 21bar. Observed no losses, no gas in returns. R/B 1x stand", "dTimEnd": "2016-09-25T14:15:00+02:00", "dTimStart": "2016-09-25T14:00:00+02:00", "md": "100", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed drops inspection on TDS. Meanwhile carried out TBT for BHA handling", "dTimEnd": "2016-09-25T14:45:00+02:00", "dTimStart": "2016-09-25T14:15:00+02:00", "md": "100", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH and L/D milling BHA", "dTimEnd": "2016-09-25T16:30:00+02:00", "dTimStart": "2016-09-25T14:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U Spear assy (run#20). Checked and inspected same. RIH to 145m", "dTimEnd": "2016-09-25T17:00:00+02:00", "dTimStart": "2016-09-25T16:30:00+02:00", "md": "145", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U TDS. Engaged fish. Observed 10t overpull to pull fish free", "dTimEnd": "2016-09-25T17:15:00+02:00", "dTimStart": "2016-09-25T17:00:00+02:00", "md": "145", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with casing fish on spear. Set casing fish in slips. Bottom of casing fish at 747m. Meanwhile finished w/ pumping postflush after batch#2 of drilling slop on F-4. Total drilling slop pumped for batch#2 of 250m3, postflush pumped of 140m3 (after batch#2), 1000l/min - 150bar. Stopped injection for 2 hours", "dTimEnd": "2016-09-25T18:00:00+02:00", "dTimStart": "2016-09-25T17:15:00+02:00", "md": "747", "phase": "fixed", "proprietaryCode": "plug abandon -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Inspected spear, found grapple cracked. Secured grapple and R/B spear BHA in derrick. Meanwhile performed TBT to R/U casing handling equipment", "dTimEnd": "2016-09-25T18:15:00+02:00", "dTimStart": "2016-09-25T18:00:00+02:00", "md": "747", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U casing handling equipment for 10 3/4in casing", "dTimEnd": "2016-09-25T19:30:00+02:00", "dTimStart": "2016-09-25T18:15:00+02:00", "md": "747", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting/Brief to pull 10 3/4in x 9 5/8in casing", "dTimEnd": "2016-09-25T19:45:00+02:00", "dTimStart": "2016-09-25T19:30:00+02:00", "md": "747", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed master bushing and installed power slips", "dTimEnd": "2016-09-25T20:00:00+02:00", "dTimStart": "2016-09-25T19:45:00+02:00", "md": "747", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with 10 3/4in casing from 747 to 334m. Average pulling speed 8,5 joints/hr. Meanwhile continued w/ pumping drilling slop batch#3 on F-4. Total preflush pumped of 70m3 (before batch#3), started pumping drilling slop, Batch#3, 1000l/min - 145bar", "dTimEnd": "2016-09-26T00:00:00+02:00", "dTimStart": "2016-09-25T20:00:00+02:00", "md": "334", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_27
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-26T00:00:00+02:00
2016-09-27T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-27T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- WOC until 22:20\n- Start pressure testing C-annulus cement plug", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": "2853", "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "9", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- Finished puling 10 3/4in casing to X-over\n- Pulled 9 5/8in casing \n- Installed 14in EZSV (lower)\n- Cut 14in casing\n- Punched below 14in subsea casing hanger\n- Installed 14in EZSV (upper)\n- Displaced C-annulus to sea water\n\n", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Continued to POOH with 10 3/4in casing from 334 to 256m. Average pulling speed 8,7 joints/hr", "dTimEnd": "2016-09-26T00:30:00+02:00", "dTimStart": "2016-09-26T00:00:00+02:00", "md": "256", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to change handling gear", "dTimEnd": "2016-09-26T00:45:00+02:00", "dTimStart": "2016-09-26T00:30:00+02:00", "md": "256", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed handling equipment for 9 5/8in casing", "dTimEnd": "2016-09-26T01:00:00+02:00", "dTimStart": "2016-09-26T00:45:00+02:00", "md": "256", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to break 10 3/4in x 9 5/8in X-over. Not able to set tongs on the x-over due to no handling pup and OD of x-over bigger than collar of 10 3/4in. Repositioned x-over below and set lower tong jaws (adjustable) on x-over, confirmed length above 9 5/8in collar is not too long to pick up with elevator. Broke 10 3/4in joint from x-over and L/D x-over together w/ 9 5/8in joint", "dTimEnd": "2016-09-26T01:45:00+02:00", "dTimStart": "2016-09-26T01:00:00+02:00", "md": "256", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed BX inserts to 9 5/8in", "dTimEnd": "2016-09-26T02:00:00+02:00", "dTimStart": "2016-09-26T01:45:00+02:00", "md": "232", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Continued to POOH with 9 5/8in casing from 232 to 0m. Used manual slips. Average pulling speed 7,6 joints/hr, totally pulled 61 joints. Meanwhile finished w/ pumping postflush after batch#3 of drilling slop on F-4. Total drilling slop pumped for batch#3 of 250m3, postflush pumped of 140m3 (after batch#3), 1000l/min - 150bar. Stopped injection for 2 hours", "dTimEnd": "2016-09-26T04:45:00+02:00", "dTimStart": "2016-09-26T02:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cleaned and cleared rig floor", "dTimEnd": "2016-09-26T05:00:00+02:00", "dTimStart": "2016-09-26T04:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to R/D casing tong", "dTimEnd": "2016-09-26T05:15:00+02:00", "dTimStart": "2016-09-26T05:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/D casing tong", "dTimEnd": "2016-09-26T06:30:00+02:00", "dTimStart": "2016-09-26T05:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- equipment recovery", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to M/U combined cutter/EZSV plug BHA (run#21)", "dTimEnd": "2016-09-26T06:45:00+02:00", "dTimStart": "2016-09-26T06:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U cutting assy and broke off taper mill. M/U M/U combined cutter/EZSV plug BHA (run#21)", "dTimEnd": "2016-09-26T07:30:00+02:00", "dTimStart": "2016-09-26T06:45:00+02:00", "md": "13", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed master bushing, installed drill pipe slips", "dTimEnd": "2016-09-26T07:45:00+02:00", "dTimStart": "2016-09-26T07:30:00+02:00", "md": "13", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ combined cutter/EZSV plug BHA (run#21) from 13 m to 878 m . Average tripping speed 500 m/hr. Meanwhile continued w/ pumping drilling slop batch#4 on F-4. Total preflush pumped of 70m3 (before batch#4), 1000l/min - 145bar", "dTimEnd": "2016-09-26T09:30:00+02:00", "dTimStart": "2016-09-26T07:45:00+02:00", "md": "878", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Set EZSV @ 877.5m. Released running tool w/ +/- 25t overpull, tagged plug w/ 10 ton", "dTimEnd": "2016-09-26T09:45:00+02:00", "dTimStart": "2016-09-26T09:30:00+02:00", "md": "878", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Established and recorded parameters before cutting casing. 80 rpm - 1-6 kNm, 400 l/min - 42 bar, 500 l/min - 60 bar, 600 l/min - 83bar. Cut casing @ 867.5m, 80rpm, 22 kNm, 400 l/min - 42bar. Observed good indication of cut: pressure dropped to 5 bar when cut performed, pulled up 1m and pressure increased to 42bar again. Meanwhile continued w/ pumping drilling slop batch#4 on F-4, started pumping drilling slop, Batch#4, 1000l/min - 145bar", "dTimEnd": "2016-09-26T10:30:00+02:00", "dTimStart": "2016-09-26T09:45:00+02:00", "md": "868", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Flow checked well. Static. Dropped drift inside stand #22", "dTimEnd": "2016-09-26T10:45:00+02:00", "dTimStart": "2016-09-26T10:30:00+02:00", "md": "868", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH wet w/ combined cutter/EZSV tool BHA (run#21) from 868 m to 0 m. Avg. tripping speed 580 m/hr. Used mud bucket", "dTimEnd": "2016-09-26T12:15:00+02:00", "dTimStart": "2016-09-26T10:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed drill pipe slips, installed master bushing", "dTimEnd": "2016-09-26T12:30:00+02:00", "dTimStart": "2016-09-26T12:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke off and L/D EZSV running tool and X-overs, M/U taper mill to bottom of cutter and L/D cutter asembly", "dTimEnd": "2016-09-26T13:00:00+02:00", "dTimStart": "2016-09-26T12:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cut", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to P/U perforation BHA (run#22). Meanwhile changed BX inserts to 4,5in", "dTimEnd": "2016-09-26T13:15:00+02:00", "dTimStart": "2016-09-26T13:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U perforation BHA (run#22)", "dTimEnd": "2016-09-26T14:15:00+02:00", "dTimStart": "2016-09-26T13:15:00+02:00", "md": "15", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ perforation BHA (run#22) from 15 m to 145,5 m (btm shot)", "dTimEnd": "2016-09-26T14:45:00+02:00", "dTimStart": "2016-09-26T14:15:00+02:00", "md": "146", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed UPR, opened choke. Applied 10 bar on IBOP. Opened IBOP to confirm line up. Filled string. Opened UPR, Broke off TDS and dropped 1 3/8 ball in string. M/U TDS. Closed UPR and opened choke. Fired guns with 160 l/min - 138 bar. Top shot at 142,5m, bottom shot at 145,5m. Continued to circulate w/ 160l/min - 2 bar. No gas observed in returns", "dTimEnd": "2016-09-26T15:15:00+02:00", "dTimStart": "2016-09-26T14:45:00+02:00", "md": "146", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Increased pump rate to 1000l/min. Pressure went up to 25 bar and then dropped and stabilized at 4 bar. Circulated 1x BU, observed small losses, quickly stabilized, gas reading close to 0 in fluid and no readings in air. Stoped pumps", "dTimEnd": "2016-09-26T15:45:00+02:00", "dTimStart": "2016-09-26T15:15:00+02:00", "md": "146", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Flowchecked well over the choke for 15 min. Stable. Open UPR, flow checked well with BOP open, stable. Meanwhile finished w/ pumping postflush after batch#4 of drilling slop on F-4. Total drilling slop pumped for batch#4 of 220m3, postflush pumped of 140m3 (after batch#4), 1000l/min - 145bar. Stopped injection", "dTimEnd": "2016-09-26T16:15:00+02:00", "dTimStart": "2016-09-26T15:45:00+02:00", "md": "146", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ perforation BHA (run#22) from 146 m to 15 m", "dTimEnd": "2016-09-26T16:30:00+02:00", "dTimStart": "2016-09-26T16:15:00+02:00", "md": "15", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D perforation BHA (run#22). All shots fired", "dTimEnd": "2016-09-26T17:00:00+02:00", "dTimStart": "2016-09-26T16:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- perforate", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to P/U EZSV assembly (run#23)", "dTimEnd": "2016-09-26T17:15:00+02:00", "dTimStart": "2016-09-26T17:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U EZSV assembly (run#23)", "dTimEnd": "2016-09-26T18:00:00+02:00", "dTimStart": "2016-09-26T17:15:00+02:00", "md": "3", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U 2x 3m pup joints and 1x 1.5m pup joint for spaceout and RIH w/ EZSV assembly to 845m. Average running speed 480m/hour", "dTimEnd": "2016-09-26T19:45:00+02:00", "dTimStart": "2016-09-26T18:00:00+02:00", "md": "845", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U side entry sub assembly", "dTimEnd": "2016-09-26T20:00:00+02:00", "dTimStart": "2016-09-26T19:45:00+02:00", "md": "845", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U TDS and recorded weights up/down 98t/91t. Washed setting area w/ L/min. Set EZSV plug at 855,3m, tagged plug w/ 10t and keep 10t weight on EZSV", "dTimEnd": "2016-09-26T20:45:00+02:00", "dTimStart": "2016-09-26T20:00:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed UPR, confirmed line up through the choke and MGS", "dTimEnd": "2016-09-26T21:00:00+02:00", "dTimStart": "2016-09-26T20:45:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pumped 10m3 Hi-vis pill at 900l/min - 14bar, continued to displace C-annulus to sea water, staged up pumps to 1700l/min - 38bar. Max gas 2,6%, 1-2 ppm H2S in fluid. Oil base mud in returns initially and sea water towards the end. Totally sea water pumped of 1,4x BU", "dTimEnd": "2016-09-26T22:45:00+02:00", "dTimStart": "2016-09-26T21:00:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Opened UPR and closed choke, flow checked the well. Stable. Meanwhile held TBT before cement job", "dTimEnd": "2016-09-26T23:00:00+02:00", "dTimStart": "2016-09-26T22:45:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Connected cement hose and LT valve", "dTimEnd": "2016-09-26T23:15:00+02:00", "dTimStart": "2016-09-26T23:00:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pumped 20m3 wash pill ahead of cement job, 1300l/min - 13,4bar. Verified line up for cement job", "dTimEnd": "2016-09-27T00:00:00+02:00", "dTimStart": "2016-09-26T23:15:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_28
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-27T00:00:00+02:00
2016-09-28T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-28T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- N/D BOP\n\n- REPORTING ON 15/9-F-9A", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": "755", "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "10", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- WOC, meanwhile performed mantenance on rig equipment\n- Pressure tested C-annulus cement plug", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Cement plug in C-annulus (467 m - 867 m): Mixed and pumped 33 m3 of 1,95 SG cement slurry, 600 l/min. Displaced the cement with 12m3 of drill water. 1000 l/min/ 12 bar, after caught up w/ cement pressure went up to 52 bar. Stopped pumping, pressure went down to 31bar. Pulled w/ running tool out of EZSV, pressure dropped to 0 bar", "dTimEnd": "2016-09-27T01:15:00+02:00", "dTimStart": "2016-09-27T00:00:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected cementing hose and L/D side entry sub. M/U pup w/ preinstalled sponge ball", "dTimEnd": "2016-09-27T01:45:00+02:00", "dTimStart": "2016-09-27T01:15:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up and pumped 10m3 wash pill, 2300l/min - 20bar. Circulated well to clean sea water until OIW reading below 30ppm. Originally mud in returns and clean sea water in the end. Max gas 3.2%. Totally circulated 108 m3, 2x BU", "dTimEnd": "2016-09-27T03:15:00+02:00", "dTimStart": "2016-09-27T01:45:00+02:00", "md": "855", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ EZSV running tool from 855 m to 11 m, average pulling speed 850m/hour", "dTimEnd": "2016-09-27T04:15:00+02:00", "dTimStart": "2016-09-27T03:15:00+02:00", "md": "11", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/D 3x 5,5in pup joints and EZSV running tool", "dTimEnd": "2016-09-27T05:00:00+02:00", "dTimStart": "2016-09-27T04:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- mechanical plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "WOC (from 01:20). Meanwhile isolated both PRSs and carried out 3 monthly PMS", "dTimEnd": "2016-09-27T07:00:00+02:00", "dTimStart": "2016-09-27T05:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "WOC. Meanwhile started with maintenance on forward and aft PRS. Meanwhile continued w/ pumping drilling slop batch#5 on F-4. Total preflush pumped of 70m3 (before batch#5), started pumping drilling slop, Batch#5, 1000l/min - 145bar", "dTimEnd": "2016-09-27T10:00:00+02:00", "dTimStart": "2016-09-27T07:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "WOC. Meanwhile continued to perform maintenance on forward and aft PRS", "dTimEnd": "2016-09-27T12:30:00+02:00", "dTimStart": "2016-09-27T10:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "WOC. Work aloft suspended due to wind speed above 50 knots. Gusting upto 60 knots. Performed high wind checks. Meanwhile performed rig PMs and maintenance", "dTimEnd": "2016-09-27T15:00:00+02:00", "dTimStart": "2016-09-27T12:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "WOC. Wind speed 52-59 knots. Continued rig floor maintenance and PMs. Prepared to clean mud pits. Hooked up line from F-09 to rig choke manifold to bleed off gas. Meanwhile finished w/ pumping postflush after batch#5 of drilling slop on F-4. Total drilling slop pumped for batch#5 of 170m3, postflush pumped of 140m3 (after batch#5), 1000l/min - 145bar", "dTimEnd": "2016-09-27T16:30:00+02:00", "dTimStart": "2016-09-27T15:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "WOC. Wind speed now below 48 knots, continued to work on aft PRS. Continued to hook up line from F-09 to rig choke manifold. Started cleaning in mud pit No. 5", "dTimEnd": "2016-09-27T17:30:00+02:00", "dTimStart": "2016-09-27T16:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "WOC. Performed maintenance on TDS. Continued to hook up line from F-09 to rig choke manifold. Continued cleaning in mud pit No. 5", "dTimEnd": "2016-09-27T19:00:00+02:00", "dTimStart": "2016-09-27T17:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Deisolated TDS", "dTimEnd": "2016-09-27T19:15:00+02:00", "dTimStart": "2016-09-27T19:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to change grapple on 10 3/4in spear", "dTimEnd": "2016-09-27T19:30:00+02:00", "dTimStart": "2016-09-27T19:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed grapple on 10 3/4in spear BHA for the well of F-4", "dTimEnd": "2016-09-27T20:15:00+02:00", "dTimStart": "2016-09-27T19:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U MST tool and M/U to 5,5in DP, RIH to 20m", "dTimEnd": "2016-09-27T20:45:00+02:00", "dTimStart": "2016-09-27T20:15:00+02:00", "md": "20", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed Master Bushings and install PS21 slips", "dTimEnd": "2016-09-27T21:00:00+02:00", "dTimStart": "2016-09-27T20:45:00+02:00", "md": "20", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH w/ MST tool on 5,5in DP from 20m to 808m, average running speed of 790m/hour. Meanwhile lined up and started pressure testing surface lines", "dTimEnd": "2016-09-27T22:00:00+02:00", "dTimStart": "2016-09-27T21:00:00+02:00", "md": "808", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed UPR, performed line test to 120 bar, good test", "dTimEnd": "2016-09-27T23:00:00+02:00", "dTimStart": "2016-09-27T22:00:00+02:00", "md": "808", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Closed IBOP, lined up to test the well with cement unit. Pressure tested C-annulus surface cement plug to 115bar for 10min. Good test", "dTimEnd": "2016-09-27T23:30:00+02:00", "dTimStart": "2016-09-27T23:00:00+02:00", "md": "808", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke off TDS and spaced out for cement job", "dTimEnd": "2016-09-28T00:00:00+02:00", "dTimStart": "2016-09-27T23:30:00+02:00", "md": "808", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_09_29
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-09-28T00:00:00+02:00
2016-09-29T00:00:00+02:00
normal
2018-05-03T13:51:42+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-09-29T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "REPORTING ON F-9A", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": "2853", "mdStrengthForm": "3192", "presTestType": "formation integrity test", "reportNo": "11", "ropCurrent": "-999.99", "strengthForm": "1.65", "sum24Hr": "- Placed balanced cement plug in 14in casing\n- N/D BOP", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": "2780", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "P/U and M/U side entry sub assembly, installed cement hose", "dTimEnd": "2016-09-28T00:15:00+02:00", "dTimStart": "2016-09-28T00:00:00+02:00", "md": "853", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to place balanced cement plug", "dTimEnd": "2016-09-28T00:30:00+02:00", "dTimStart": "2016-09-28T00:15:00+02:00", "md": "853", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pumped 10m3 wash pill. Staged up rate to 2200l/min - 16bar", "dTimEnd": "2016-09-28T00:45:00+02:00", "dTimStart": "2016-09-28T00:30:00+02:00", "md": "853", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Balanced cement plug (755 m - 855 m ): Mixed and pumped 8 m3 of 1,95 SG cement slurry, 600 l/min. Zeroed volume counters. Displaced the cement with 9m3. 1000 l/min - 12 bar. Caught up with cement, pressure increased to 25bar. Theoretical TOC 755 m MD", "dTimEnd": "2016-09-28T01:30:00+02:00", "dTimStart": "2016-09-28T00:45:00+02:00", "md": "853", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of cement to 655m at 2 min/stand.", "dTimEnd": "2016-09-28T02:00:00+02:00", "dTimStart": "2016-09-28T01:30:00+02:00", "md": "655", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U pup w/ pre-installed sponge ball. Circulated above cement plug at 3300 l/min - 30 bar, 50 RPM. Diverted returns overboard. Total circulated 75m3 (1,7x BU)", "dTimEnd": "2016-09-28T02:45:00+02:00", "dTimStart": "2016-09-28T02:00:00+02:00", "md": "655", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH w/ MST tool from 655m to surface. Average tripping speed of 870 m/hour", "dTimEnd": "2016-09-28T03:30:00+02:00", "dTimStart": "2016-09-28T02:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed PS21 and installed master bushing", "dTimEnd": "2016-09-28T03:45:00+02:00", "dTimStart": "2016-09-28T03:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke off stand#1 and R/B same, L/D MST tool", "dTimEnd": "2016-09-28T04:15:00+02:00", "dTimStart": "2016-09-28T03:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U BOP jetting tool to stand#1. Jet BOP 1400l/min - 24 bar - 40 rpm. Function tested BOP. L/D BOP jetting tool and R/B DP stand", "dTimEnd": "2016-09-28T05:15:00+02:00", "dTimStart": "2016-09-28T04:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- cement plug", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to N/D diverter", "dTimEnd": "2016-09-28T05:30:00+02:00", "dTimStart": "2016-09-28T05:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drained riser, meanwhile removed BX elevators and rotator. Installed lifting chains for diverter to bails", "dTimEnd": "2016-09-28T06:00:00+02:00", "dTimStart": "2016-09-28T05:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled master bushing and outer ring, attached lifting chains to diverter. Bled down pressure on diverter, disconnected overshot hose", "dTimEnd": "2016-09-28T07:00:00+02:00", "dTimStart": "2016-09-28T06:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled diverter and secured same on DP set back area", "dTimEnd": "2016-09-28T08:00:00+02:00", "dTimStart": "2016-09-28T07:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Disconnected and pull slick joint to rig floor. Meanwhile hook up bleed off line to F-09", "dTimEnd": "2016-09-28T09:30:00+02:00", "dTimStart": "2016-09-28T08:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to release BOP tension system", "dTimEnd": "2016-09-28T09:45:00+02:00", "dTimStart": "2016-09-28T09:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed BOP tension cylinders. Meanwhile continued w/ pumping drilling slop batch#6 on F-4. Total preflush pumped of 70m3 (before batch#6), started pumping drilling slop, Batch#6, 1000l/min - 140bar", "dTimEnd": "2016-09-28T11:15:00+02:00", "dTimStart": "2016-09-28T09:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Skidded BOP from well center to test stump. Meanwhile perform maintenance on FWD PRS. Emptied skimmer tank", "dTimEnd": "2016-09-28T12:00:00+02:00", "dTimStart": "2016-09-28T11:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Dismantled scaffolding from well center. Meanwhile performed maintenance on FWD PRS", "dTimEnd": "2016-09-28T12:45:00+02:00", "dTimStart": "2016-09-28T12:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed master bushing and outer ring in RKB", "dTimEnd": "2016-09-28T13:00:00+02:00", "dTimStart": "2016-09-28T12:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed Pre-job Meeting to L/D high pressure riser", "dTimEnd": "2016-09-28T13:15:00+02:00", "dTimStart": "2016-09-28T13:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Connected lifting gear and pulled HP riser, L/D same", "dTimEnd": "2016-09-28T14:15:00+02:00", "dTimStart": "2016-09-28T13:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed split hatches on F-11 and installed solid cover. Meanwhile ventilated gas from annulus on F-09 to rig choke. Meanwhile finished w/ pumping postflush after batch#6 of drilling slop on F-4. Total drilling slop pumped for batch#6 of 123m3, postflush pumped of 140m3 (after batch#5), 1000l/min - 137bar \n\nREPORTING ON F-9A", "dTimEnd": "2016-09-28T16:15:00+02:00", "dTimStart": "2016-09-28T14:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_10_21
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-10-20T00:00:00+02:00
2016-10-21T00:00:00+02:00
normal
2018-05-03T13:51:43+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-10-21T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "- Skid to well F-1 C\n- Pull production riser on well F-1 C\n", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": null, "presTestType": "leak off test", "reportNo": "12", "ropCurrent": "-999.99", "strengthForm": null, "sum24Hr": "- Skidded to well F-11 B\n- Pulled production riser", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": null, "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "Performed TBT for skidding rig to F-11 B", "dTimEnd": "2016-10-20T08:30:00+02:00", "dTimStart": "2016-10-20T08:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Skidded cantilever to well F-11 B", "dTimEnd": "2016-10-20T08:45:00+02:00", "dTimStart": "2016-10-20T08:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed post-skid checks.", "dTimEnd": "2016-10-20T09:00:00+02:00", "dTimStart": "2016-10-20T08:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed hatch.\nBuilt scaffolding around hole opening in moonpool.\n\nMeanwhile: Installed deck hatches on well F-12.", "dTimEnd": "2016-10-20T09:30:00+02:00", "dTimStart": "2016-10-20T09:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed scaffolding on WH deck to access well F-11.\n\nMeanwhile: Changed elevator.", "dTimEnd": "2016-10-20T09:45:00+02:00", "dTimStart": "2016-10-20T09:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "moving -- skid", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lowered and N/U NT2 connector.\nInstalled master bushing.", "dTimEnd": "2016-10-20T10:15:00+02:00", "dTimStart": "2016-10-20T09:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U BHA and inner string.", "dTimEnd": "2016-10-20T11:15:00+02:00", "dTimStart": "2016-10-20T10:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Engaged Multibowl RT to Multibowl. Confirmed with 20 ton overpull.", "dTimEnd": "2016-10-20T11:30:00+02:00", "dTimStart": "2016-10-20T11:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Load shifted weight from tension cylinders to TDS.\nN/D tension cylinders and boat collision stool.\nBuilt scaffolding around hole opening.", "dTimEnd": "2016-10-20T13:30:00+02:00", "dTimStart": "2016-10-20T11:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Staged up flow rate to 2400 lpm / 80 bar.\nCut riser at 134,9m. Observed loss of overpull, good indication of cut.", "dTimEnd": "2016-10-20T13:45:00+02:00", "dTimStart": "2016-10-20T13:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/D hoses and valve outlets from Multibowl.\nPulled master bushing.", "dTimEnd": "2016-10-20T14:30:00+02:00", "dTimStart": "2016-10-20T13:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled Multibowl, riser and inner string to drill floor. Installed master bushing and C-plate.\nLaned off Multibowl onto C-plate.", "dTimEnd": "2016-10-20T14:45:00+02:00", "dTimStart": "2016-10-20T14:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U TDS and B/O Multibowl RT. R/B same.", "dTimEnd": "2016-10-20T15:00:00+02:00", "dTimStart": "2016-10-20T14:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U false rotary and C-plate.", "dTimEnd": "2016-10-20T15:15:00+02:00", "dTimStart": "2016-10-20T15:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with inner string. R/B cutter BHA.", "dTimEnd": "2016-10-20T16:00:00+02:00", "dTimStart": "2016-10-20T15:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U Mutlibowl RT.", "dTimEnd": "2016-10-20T16:15:00+02:00", "dTimStart": "2016-10-20T16:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with riser (Lift #1). Cleaned off marine growth on centralizer deck.\nMeanwhile: Performed TBT for L/O Multibowl and tensioner joint.", "dTimEnd": "2016-10-20T17:00:00+02:00", "dTimStart": "2016-10-20T16:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U cutting machine", "dTimEnd": "2016-10-20T17:15:00+02:00", "dTimStart": "2016-10-20T17:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to cut riser. Significant wave height 0,8m\nObserved vibrations after cut a few millimeters into the tensioner joint.\nCutter jammed several times.", "dTimEnd": "2016-10-20T19:00:00+02:00", "dTimStart": "2016-10-20T17:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed TBT with ongoing crew", "dTimEnd": "2016-10-20T19:15:00+02:00", "dTimStart": "2016-10-20T19:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Re-aligned cutter and started new cut.\nCut riser, vibrations still present. Significant wave height 0,7m.\nR/D cutting machine.", "dTimEnd": "2016-10-20T20:45:00+02:00", "dTimStart": "2016-10-20T19:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/O Multibowl and tensioner joint.\nRemoved Multibowl RT and NT2 connector.", "dTimEnd": "2016-10-20T21:15:00+02:00", "dTimStart": "2016-10-20T20:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled riser (Lift #2). Cleaned off marine growth on centralizer deck.\nLanded off riser onto elevator.", "dTimEnd": "2016-10-20T21:45:00+02:00", "dTimStart": "2016-10-20T21:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U cutting machine\nCut riser, no further vibrations observed. Significant wave height 0,8m\nR/D cutting machine", "dTimEnd": "2016-10-20T22:15:00+02:00", "dTimStart": "2016-10-20T21:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/O riser joint (Lift #2).\nPulled riser (Lift #3). Cleaned off marine growth on centralizer deck.\nLanded off riser onto elevator.\n", "dTimEnd": "2016-10-20T22:45:00+02:00", "dTimStart": "2016-10-20T22:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U cutting machine\nCut riser. Significant wave height 0,7m\nR/D cutting machine.", "dTimEnd": "2016-10-20T23:00:00+02:00", "dTimStart": "2016-10-20T22:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/O riser joint (Lift #3).\nPulled riser (Lift #4). Cleaned off marine growth on centralizer deck.\nLanded off riser onto elevator.\nRiser out of splash zone at 23:30", "dTimEnd": "2016-10-20T23:30:00+02:00", "dTimStart": "2016-10-20T23:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U cutting machine\nCut riser.\nR/D cutting machine.", "dTimEnd": "2016-10-21T00:00:00+02:00", "dTimStart": "2016-10-20T23:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_B_2016_10_22
NO 15/9-F-11 B
NO 15/9-F-11 B
name
2016-10-21T00:00:00+02:00
2016-10-22T00:00:00+02:00
normal
2018-05-03T13:51:43+02:00
{ "name": "15/9-F-11 B", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 B", "namingSystem": "NPD code" }, { "name": "7080", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-05-28T14:30:00+02:00", "dateDrillComplete": "2013-06-12", "daysBehind": null, "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2016-10-22T00:00:00+02:00", "dTimDiaHoleStart": "2016-09-18T05:45:00+02:00", "diaHole": null, "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "None", "hpht": "0", "md": "-999.99", "mdCsgLast": "4768.7", "mdDiaHoleStart": "3500", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": null, "presTestType": "leak off test", "reportNo": "13", "ropCurrent": "-999.99", "strengthForm": null, "sum24Hr": "None", "tightWell": "0", "tvd": null, "tvdCsgLast": "3257", "tvdStrengthForm": null, "waterDepth": "91", "wellheadElevation": "138.9" } ]
[]
[]
[]
[ { "comments": "L/O riser joint (Lift #4).\nPulled riser (Lift #5). Cleaned off marine growth on centralizer deck.\nLanded off riser onto elevator.", "dTimEnd": "2016-10-21T00:30:00+02:00", "dTimStart": "2016-10-21T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U cutting machine\nCut riser\nR/D cutting machine", "dTimEnd": "2016-10-21T00:45:00+02:00", "dTimStart": "2016-10-21T00:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/O riser joint (Lift #5).\nPulled riser (Lift #6). Cleaned off marine growth on centralizer deck.\nLanded off riser onto elevator.", "dTimEnd": "2016-10-21T01:15:00+02:00", "dTimStart": "2016-10-21T00:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U cutting machine\nCut riser\nR/D cutting machine", "dTimEnd": "2016-10-21T01:30:00+02:00", "dTimStart": "2016-10-21T01:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "L/O riser joint (Lift #6).\nPulled riser (Lift #7).\nL/O last riser joint.", "dTimEnd": "2016-10-21T02:15:00+02:00", "dTimStart": "2016-10-21T01:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cleaned and cleared drill floor", "dTimEnd": "2016-10-21T02:30:00+02:00", "dTimStart": "2016-10-21T02:15:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed hatches and hole covers in moonpool and WH deck.\nRemoved scaffolding.\n\n*** END OF REPORT ***", "dTimEnd": "2016-10-21T03:30:00+02:00", "dTimStart": "2016-10-21T02:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "plug abandon -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_03_24
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-23T00:00:00+01:00
2013-03-24T00:00:00+01:00
normal
2018-05-03T13:51:26+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "11.8", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-03-24T00:00:00+01:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "49", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill and orient 26\" hole from 306 m.", "hpht": "0", "md": "306", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "18", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Transferred over from well 15/9-F-11. Oriented drilled 26\" hole from 257 m to 266 m. Observed 30 tons overpull. Made wiper trip back to 30\" Conductor shoe at 202 m . Drilled and oriented 26\" hole from 266 m to 306 m.", "tightWell": "0", "tvd": "306", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-24T00:00:00+01:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "27", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14.5" } ]
[]
[ { "azi": "310.5", "dTim": "2013-03-24T00:00:00+01:00", "incl": "1.32", "md": "264", "tvd": "264" }, { "azi": "316.92", "dTim": "2013-03-24T00:00:00+01:00", "incl": "1.41", "md": "276.4", "tvd": "276.4" }, { "azi": "316.94", "dTim": "2013-03-24T00:00:00+01:00", "incl": "1.55", "md": "284.5", "tvd": "284.5" }, { "azi": "318.66", "dTim": "2013-03-24T00:00:00+01:00", "incl": "1.32", "md": "290.2", "tvd": "290.2" } ]
[ { "comments": "Transferred over from well 15/9-F-11.\n\nOriented time drilled 26\" hole from 257 m to 266 m, 3080 l/min, 75 bar, 1 - 2 tons WOB, 2 m/hrs. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-23T10:30:00+01:00", "dTimStart": "2013-03-23T05:30:00+01:00", "md": "266", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Attempted to take MWD Gyro trac survey, no-go.", "dTimEnd": "2013-03-23T11:00:00+01:00", "dTimStart": "2013-03-23T10:30:00+01:00", "md": "266", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Attempted to L/D single 5 1/2\" DP joint to prior to taking wirelien Gyro survey. P/U with 30 tons overpull and pulled free. Pumped Hi-vis sweep and circulated same out of hole. Increased flow to 4100 l/min, 130 bar and worked string over interval 237 m to 244 m.", "dTimEnd": "2013-03-23T12:30:00+01:00", "dTimStart": "2013-03-23T11:00:00+01:00", "md": "266", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Made wiper trip from 244 m to inside 30\" shoe at 202 m with 3000 l/min, 72 bar, 15 RPM, 2 kNm.", "dTimEnd": "2013-03-23T14:00:00+01:00", "dTimStart": "2013-03-23T12:30:00+01:00", "md": "238", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Washed and reamed down from 30\" Conductor shoe at 202 m to 244 m, 3000 l/min, 72 bar, 15 RPM, 2 kNm, no obstruction observed. Reamed back from 244 m to 238 m, 3000 l/min, 72 bar, 15 RPM, 2 kNm.", "dTimEnd": "2013-03-23T15:00:00+01:00", "dTimStart": "2013-03-23T14:00:00+01:00", "md": "244", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "R/U wireline, RIH and took Gyro survey (238 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 196 0.14 241.85", "dTimEnd": "2013-03-23T15:30:00+01:00", "dTimStart": "2013-03-23T15:00:00+01:00", "md": "238", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Washed down from 238 m to bottom at 266 m, 3000 - 3500 l/min, 72 - 90 bar. No obstruction observed.", "dTimEnd": "2013-03-23T16:30:00+01:00", "dTimStart": "2013-03-23T15:30:00+01:00", "md": "266", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "R/U wireline, RIH and took Gyro survey (265 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 223.6 0.58 285.5", "dTimEnd": "2013-03-23T17:00:00+01:00", "dTimStart": "2013-03-23T16:30:00+01:00", "md": "265", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Oriented toolface, POOH and R/D wireline. Oriented time drilled 26\" hole from 266 m to 272 m, 3460 l/min, 98 bar, 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-23T19:00:00+01:00", "dTimStart": "2013-03-23T17:00:00+01:00", "md": "279", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Evaluated directional data. Drilled 26\" hole from 272 m to 279 m, 3460 l/min, 98 bar, 40 RPM, 5 kNm, 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-23T20:30:00+01:00", "dTimStart": "2013-03-23T19:00:00+01:00", "md": "279", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "R/U wireline, RIH and took Gyro survey (277 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 236.9 0.59 283.17", "dTimEnd": "2013-03-23T21:00:00+01:00", "dTimStart": "2013-03-23T20:30:00+01:00", "md": "279", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Drilled 26 hole from 279 m to 292 m, 3670 l/min, 110 bar, 40 RPM, 5 kNm, 2 - 5 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-23T22:00:00+01:00", "dTimStart": "2013-03-23T21:00:00+01:00", "md": "292", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "R/U wireline, RIH and took Gyro survey (290 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 249.0 0.97 314.87", "dTimEnd": "2013-03-23T22:30:00+01:00", "dTimStart": "2013-03-23T22:00:00+01:00", "md": "292", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Drilled 26 hole from 292 m to 306 m, 3670 l/min, 110 bar, 40 RPM, 4 kNm, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-23T23:30:00+01:00", "dTimStart": "2013-03-23T22:30:00+01:00", "md": "306", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "R/U wireline, RIH and took Gyro survey (305 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 264.0 1.32 310.50", "dTimEnd": "2013-03-24T00:00:00+01:00", "dTimStart": "2013-03-23T23:30:00+01:00", "md": "306", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" } ]
[]
15_9_F_11_T2_2013_03_25
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-24T00:00:00+01:00
2013-03-25T00:00:00+01:00
normal
2018-05-03T13:51:26+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "12.3", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-03-25T00:00:00+01:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "107", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "POOH for repair of crown block.", "hpht": "0", "md": "454", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "19", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Oriented and drilled 26\" hole from 347 m to 454 m. Recorded Gyro surveys. Found out crown block fast-line sheave bearings had failed. Prepared to displace hole to 1.35 sg KCl mud and POOH 26\" BHA from 454 m.", "tightWell": "0", "tvd": "454", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-25T00:00:00+01:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "27", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14.5" } ]
[]
[ { "azi": "318.4", "dTim": "2013-03-25T00:00:00+01:00", "incl": "1.13", "md": "358.2", "tvd": "358.2" }, { "azi": "320.72", "dTim": "2013-03-25T00:00:00+01:00", "incl": "1.16", "md": "371.7", "tvd": "371.7" }, { "azi": "317.81", "dTim": "2013-03-25T00:00:00+01:00", "incl": "1.4", "md": "385", "tvd": "385" }, { "azi": "319.73", "dTim": "2013-03-25T00:00:00+01:00", "incl": "1.78", "md": "398.2", "tvd": "398.2" }, { "azi": "321.43", "dTim": "2013-03-25T00:00:00+01:00", "incl": "1.06", "md": "305", "tvd": "305" }, { "azi": "327.19", "dTim": "2013-03-25T00:00:00+01:00", "incl": ".98", "md": "317", "tvd": "317" }, { "azi": "321.81", "dTim": "2013-03-25T00:00:00+01:00", "incl": "1.08", "md": "332", "tvd": "332" }, { "azi": "325.46", "dTim": "2013-03-25T00:00:00+01:00", "incl": "1.07", "md": "344.7", "tvd": "344.7" } ]
[ { "comments": "Drilled 26\" hole from 306 m to 318 m, 3650 l/min, 105 bar, 40 RPM, 5 kNm, 2 - 5 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T01:30:00+01:00", "dTimStart": "2013-03-24T00:00:00+01:00", "md": "318", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "R/U wireline, RIH and took Gyro survey (317 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 276.4 1.41 316.92", "dTimEnd": "2013-03-24T02:00:00+01:00", "dTimStart": "2013-03-24T01:30:00+01:00", "md": "318", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Drilled 26\" hole from 318 m to 333 m, 3650 l/min, 105 bar, 40 RPM, 5 kNm, 2 - 5 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T03:00:00+01:00", "dTimStart": "2013-03-24T02:00:00+01:00", "md": "333", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "R/U wireline, RIH and took Gyro survey (332 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 290.2 1.30 318.66", "dTimEnd": "2013-03-24T03:30:00+01:00", "dTimStart": "2013-03-24T03:00:00+01:00", "md": "333", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Drilled 26\" hole from 333 m to 346 m, 3760 l/min, 110 bar, 40 RPM, 5 kNm, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T04:30:00+01:00", "dTimStart": "2013-03-24T03:30:00+01:00", "md": "346", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "R/U wireline, RIH and took Gyro survey (345 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 305 1.06 321.43", "dTimEnd": "2013-03-24T05:00:00+01:00", "dTimStart": "2013-03-24T04:30:00+01:00", "md": "346", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Drilled 26\" hole from 346 m to 359 m, 3760 l/min, 110 bar, 40 RPM, 5 kNm, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T06:00:00+01:00", "dTimStart": "2013-03-24T05:00:00+01:00", "md": "359", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U wireline, RIH and took Gyro survey (358 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 317.0 0.98 327.19", "dTimEnd": "2013-03-24T07:00:00+01:00", "dTimStart": "2013-03-24T06:00:00+01:00", "md": "359", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 26\" hole from 359 m to 374 m, 3760 l/min, 110 bar, 40 RPM, 5 kNm, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T08:00:00+01:00", "dTimStart": "2013-03-24T07:00:00+01:00", "md": "374", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U wireline, RIH and took Gyro survey (373 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 332.0 1.08 321.81", "dTimEnd": "2013-03-24T08:30:00+01:00", "dTimStart": "2013-03-24T08:00:00+01:00", "md": "374", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 26\" hole from 374 m to 387 m, 4400 l/min, 155 bar, 40 RPM, 5 kNm, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T09:30:00+01:00", "dTimStart": "2013-03-24T08:30:00+01:00", "md": "387", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to take MWD survey, no-go. R/U wireline, RIH and took Gyro survey (386 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 344.7 1.07 325.46", "dTimEnd": "2013-03-24T10:30:00+01:00", "dTimStart": "2013-03-24T09:30:00+01:00", "md": "387", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 26\" hole from 387 m to 402 m, 4500 l/min, 155 bar, 40 RPM, 5 kNm, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T11:00:00+01:00", "dTimStart": "2013-03-24T10:30:00+01:00", "md": "402", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to take MWD survey, no-go. R/U wireline, RIH and took Gyro survey (401 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 358.2 1.13 318.40", "dTimEnd": "2013-03-24T12:30:00+01:00", "dTimStart": "2013-03-24T11:00:00+01:00", "md": "402", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Orient drilled 26\" hole from 387 m to 402 m, 4500 l/min, 155 bar, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T13:00:00+01:00", "dTimStart": "2013-03-24T12:30:00+01:00", "md": "414", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U wireline, RIH and took Gyro survey (413 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 371.7 1.16 320.72", "dTimEnd": "2013-03-24T13:30:00+01:00", "dTimStart": "2013-03-24T13:00:00+01:00", "md": "414", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Orient drilled 26\" hole from 414 m to 421 m, 4500 l/min, 155 bar, 2 - 4 tons WOB. Started rotation, 40 RPM, 4 kNm and continued drilling 26\" hole from 421 m to 428 m, 4500 l/min, 155 bar, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T14:00:00+01:00", "dTimStart": "2013-03-24T13:30:00+01:00", "md": "428", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to take MWD survey, no-go. R/U wireline, RIH and took Gyro survey (427 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 385.0 1.40 317.81", "dTimEnd": "2013-03-24T15:00:00+01:00", "dTimStart": "2013-03-24T14:00:00+01:00", "md": "428", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 26\" hole from 428 m to 441 m, 3500 - 4500 l/min, 70 - 155 bar, 40 RPM, 5 kNm, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T15:30:00+01:00", "dTimStart": "2013-03-24T15:00:00+01:00", "md": "441", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to take MWD survey, no-go. R/U wireline, RIH and took Gyro survey (440 m bit depth):\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 398.2 1.78 319.73", "dTimEnd": "2013-03-24T16:30:00+01:00", "dTimStart": "2013-03-24T15:30:00+01:00", "md": "441", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 26\" hole from 428 m to 441 m, 4500 l/min, 155 bar, 40 RPM, 5 kNm, 2 - 4 tons WOB. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T17:00:00+01:00", "dTimStart": "2013-03-24T16:30:00+01:00", "md": "454", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Attempted to take MWD survey, no-go. Detected unusual noise from crown block fast-line sheave.", "dTimEnd": "2013-03-24T17:30:00+01:00", "dTimStart": "2013-03-24T17:00:00+01:00", "md": "454", "phase": "fixed", "proprietaryCode": "drilling -- survey", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Checked crown block fast-line sheave and found bearing ceased onto shaft. Evaluated situation and informed offshore and onshore managment. Prepared forward plan to POOH 26\" BHA prior to working on fast-line sheave. Barriered off rig floor and cantelever.\n\nMeanwhile:\nCirculated well 1100 l/min, 8 bar, 20 RPM, 2 kNm. Attempted to apply lubricant to fast-line sheave.", "dTimEnd": "2013-03-24T21:30:00+01:00", "dTimStart": "2013-03-24T17:30:00+01:00", "md": "454", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed Pre-job Meeting held SJA on drill floor prior to POOH.\n\nMeanwhile:\nCirculated well 1100 l/min, 8 bar, 20 RPM, 2 kNm. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-24T22:30:00+01:00", "dTimStart": "2013-03-24T21:30:00+01:00", "md": "454", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Prepared POOH from 453 m to surface. Installed grease pump in crown block. Transferred 1.35 sg KCl mud to active. Rigged down wireline equipment. \n\nMeanwhile:\nCirculated well 1100 l/min, 8 bar, 20 RPM, 2 kNm. Pumped Hi-vis sweeps.", "dTimEnd": "2013-03-25T00:00:00+01:00", "dTimStart": "2013-03-24T22:30:00+01:00", "md": "454", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_T2_2013_03_26
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-25T00:00:00+01:00
2013-03-26T00:00:00+01:00
normal
2018-05-03T13:51:26+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "13", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-03-26T00:00:00+01:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Dismantle failed fast-line sheave and prepare for installing replacement fast-line sheave in crown block. ", "hpht": "0", "md": "454", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "20", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "POOH 26\" BHA from bottom at 454 m to surface. L/D 26\" BHA to deck. Prepared for changing out fast-line sheave in crown block.", "tightWell": "0", "tvd": "454", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-26T00:00:00+01:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "27", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14.5" } ]
[]
[]
[ { "comments": "Prepared POOH from bottom at 453 m. Installed grease pump in crown block. Oriented 26\" steering BHA. Displaced well to 1.35 sg KCl mud, 1100 - 3100 l/min, 8 - 70 bar. Confirmed barriered off rig floor and cantelever. POOH from 454 m, recorded overpull of 30 tons. Broke circulation 650 l/min, 10 bar, 40 RPM, 15 kNm. POOH up through tight spot from 454 to 438 m. Stand of 5 1/2\" DP mistakenly released from elevators while still connected in rotary.", "dTimEnd": "2013-03-25T02:00:00+01:00", "dTimStart": "2013-03-25T00:00:00+01:00", "md": "438", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Connected PRS to 5 1/2\" DP stand in derrick and connected elevators to same.", "dTimEnd": "2013-03-25T02:30:00+01:00", "dTimStart": "2013-03-25T02:00:00+01:00", "md": "438", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "POOH 26\" BHA on 5 1/2\" DP from 438 m and above seabed at 144 m to 128 m observed by ROV.", "dTimEnd": "2013-03-25T06:00:00+01:00", "dTimStart": "2013-03-25T02:30:00+01:00", "md": "128", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "R/B 26\" BHA from 128 m to 100 m.", "dTimEnd": "2013-03-25T07:00:00+01:00", "dTimStart": "2013-03-25T06:00:00+01:00", "md": "100", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed Pre-job Meeting with new crew prior to handling 26\" BHA.", "dTimEnd": "2013-03-25T07:30:00+01:00", "dTimStart": "2013-03-25T07:00:00+01:00", "md": "100", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "R/B 26\" BHA from 100 m to 37 m.", "dTimEnd": "2013-03-25T10:00:00+01:00", "dTimStart": "2013-03-25T07:30:00+01:00", "md": "37", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed Pre-job Meeting prior to L/D 26\" BHA to deck.", "dTimEnd": "2013-03-25T10:30:00+01:00", "dTimStart": "2013-03-25T10:00:00+01:00", "md": "37", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Dumped MWD data and L/D 26\" BHA to deck.", "dTimEnd": "2013-03-25T13:30:00+01:00", "dTimStart": "2013-03-25T10:30:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Cleared and cleaned rig floor.", "dTimEnd": "2013-03-25T14:00:00+01:00", "dTimStart": "2013-03-25T13:30:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed Pre-job Meeting prior to preparing for changing out fast-line sheave in crown block.", "dTimEnd": "2013-03-25T14:30:00+01:00", "dTimStart": "2013-03-25T14:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Prepared for changing out fast-line sheave in crown block. Visually inspected top drive, hung off top drive, rigged down wireline equipment.", "dTimEnd": "2013-03-25T21:30:00+01:00", "dTimStart": "2013-03-25T14:30:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed pre-job meeting prior to work aloft on fast-line sheave in crown block.", "dTimEnd": "2013-03-25T22:00:00+01:00", "dTimStart": "2013-03-25T21:30:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Waited on flair prior to work aloft.\n\nMeanwhile: Made tools ready to work on fast-line sheave in crown block, cleared and cleaned rig floor, prepared BOP test stump and performed general rig maintenance.", "dTimEnd": "2013-03-26T00:00:00+01:00", "dTimStart": "2013-03-25T22:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_T2_2013_03_27
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-26T00:00:00+01:00
2013-03-27T00:00:00+01:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "14", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-03-27T00:00:00+01:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Replace fast-line sheave in crown block. M/U 26\" BHA and RIH to commence drilling 26\" hole.", "hpht": "0", "md": "454", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "21", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Prepared for changing out fast-line sheave in crown block. Performed general rig maintenance.", "tightWell": "0", "tvd": "454", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-27T00:00:00+01:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "27", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14.5" } ]
[]
[]
[ { "comments": "Prepared for changing out fast-line sheave in crown block. Transferred tools to derrick.\n\nMeanwhile: Performed general rig maintenance.", "dTimEnd": "2013-03-26T07:00:00+01:00", "dTimStart": "2013-03-26T00:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed pre-job meeting prior to work aloft on fast-line sheave in crown block.", "dTimEnd": "2013-03-26T07:30:00+01:00", "dTimStart": "2013-03-26T07:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Prepared for changing out fast-line sheave in crown block. Transferred high-torque tools to derrick. Loosened all bolts on sheave and secured same in derrick.\n\nMeanwhile: Performed general rig maintenance, changed wires on overhead cranes, detected leakage on BOP annular function and trouble shoot same.", "dTimEnd": "2013-03-26T19:00:00+01:00", "dTimStart": "2013-03-26T07:30:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed pre-job meeting prior to work aloft on fast-line sheave in crown block.", "dTimEnd": "2013-03-26T19:30:00+01:00", "dTimStart": "2013-03-26T19:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Prepared for transferring fast-line sheave from derrick to drill floor.\n\nMeanwhile: Performed general rig maintenance, trouble shoot leakage on BOP annular function.", "dTimEnd": "2013-03-27T00:00:00+01:00", "dTimStart": "2013-03-26T19:30:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_T2_2013_03_28
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-27T00:00:00+01:00
2013-03-28T00:00:00+01:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "15", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-03-28T00:00:00+01:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "M/U 26\" BHA and RIH to commence drilling 26\" hole. Drill 26\" hole.", "hpht": "0", "md": "454", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "22", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Repaired fast-line sheave in derrick. Performed general maintenance.", "tightWell": "0", "tvd": "454", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-28T00:00:00+01:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "27", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14.5" } ]
[]
[]
[ { "comments": "Transferred fast-line sheave from derrick to drill floor, and lifted same from rig floor to welders workshop.\n\nMeanwhile: Performed general rig maintenance, trouble shoot leakage on BOP annular function.", "dTimEnd": "2013-03-27T06:00:00+01:00", "dTimStart": "2013-03-27T00:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Repaired failed fast line sheave and re-assembled bearing assembly. \n\nMeanwhile: Performed service and visual inspection of forward and aft Pipe Racking System. Continued BOP annular repair. Tested backup MWD tools. Serviced TDS travelling block and dolly. Repaired TDS hangoff wire.", "dTimEnd": "2013-03-27T14:00:00+01:00", "dTimStart": "2013-03-27T06:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Transferred fast-line sheave to rig floor. Prepared sheave for transport to crown block.", "dTimEnd": "2013-03-27T14:30:00+01:00", "dTimStart": "2013-03-27T14:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed toolbox talk prior to hoisting fast-line sheave to crown.", "dTimEnd": "2013-03-27T15:00:00+01:00", "dTimStart": "2013-03-27T14:30:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Transferred fast-line sheave from drill floor to derrick. Installed sheave.\n\nMeanwhile: Performed general rig maintenance, trouble shoot leakage on BOP annular function.", "dTimEnd": "2013-03-28T00:00:00+01:00", "dTimStart": "2013-03-27T15:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_T2_2013_03_29
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-28T00:00:00+01:00
2013-03-29T00:00:00+01:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "16", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-03-29T00:00:00+01:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill and orient 26\" hole.", "hpht": "0", "md": "454", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "23", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Repaired fast-line sheave in derrick. Performed general maintenance. Picked up and made up 26\" bottom hole assembly.", "tightWell": "0", "tvd": "454", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-29T00:00:00+01:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "27", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14.5" } ]
[]
[ { "azi": "313.14", "dTim": "2013-03-29T00:00:00+01:00", "incl": "2.55", "md": "426.7", "tvd": "426.6" }, { "azi": "316.3", "dTim": "2013-03-29T00:00:00+01:00", "incl": "2.46", "md": "444.6", "tvd": "444.5" } ]
[ { "comments": "Continued installing fast-line sheave in derrick.\n\nMeanwhile: Repaired leakage on BOP annular function. Prepared to function test same.", "dTimEnd": "2013-03-28T07:00:00+01:00", "dTimStart": "2013-03-28T00:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed prejob meeting prior to rig down lifting gear and equipment from derrick.", "dTimEnd": "2013-03-28T07:30:00+01:00", "dTimStart": "2013-03-28T07:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Transfered equipment from derrick to rig floor and rigged down lifting equipment. Performed derrick inspection. Calibrated crown grease pump. Ran drawworks and confirmed sheave movement.", "dTimEnd": "2013-03-28T12:00:00+01:00", "dTimStart": "2013-03-28T07:30:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Rigged up wireline sheave.", "dTimEnd": "2013-03-28T12:30:00+01:00", "dTimStart": "2013-03-28T12:00:00+01:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Picked up and made up 26\" bottom hole assembly to 10m.", "dTimEnd": "2013-03-28T13:15:00+01:00", "dTimStart": "2013-03-28T12:30:00+01:00", "md": "10", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Waiting for stop of production on well F-14/F-12. \n\nMeanwhile: Performed general maintenance.", "dTimEnd": "2013-03-28T14:15:00+01:00", "dTimStart": "2013-03-28T13:15:00+01:00", "md": "10", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Picked up and made up 26\" bottom hole assembly to 140m.", "dTimEnd": "2013-03-28T22:00:00+01:00", "dTimStart": "2013-03-28T14:15:00+01:00", "md": "140", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Stung 26\" bit into conductor housing funnel and ran in hole with 26\" bottom hole assembly from 140m MD to 152m MD. Informed production supervisor - ready to start up F-14 production.", "dTimEnd": "2013-03-28T22:30:00+01:00", "dTimStart": "2013-03-28T22:00:00+01:00", "md": "152", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed Pre-job Meeting prior to run in hole with 26\" bottom hole assembly.\n\nMeanwhile: Ran wireline gyro and set to 356 degrees.", "dTimEnd": "2013-03-28T23:00:00+01:00", "dTimStart": "2013-03-28T22:30:00+01:00", "md": "152", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Ran in hole with 26\" bottom hole assembly on 5 1/2\" drill pipe from 152m MD to 230m MD.", "dTimEnd": "2013-03-29T00:00:00+01:00", "dTimStart": "2013-03-28T23:00:00+01:00", "md": "230", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_T2_2013_03_30
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-29T00:00:00+01:00
2013-03-30T00:00:00+01:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "16.3", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-03-30T00:00:00+01:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "339", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill 26\" hole.", "hpht": "0", "md": "793", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "24", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Drilled and oriented 26\" hole from 454m MD to 793m MD.", "tightWell": "0", "tvd": "792.1", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-30T00:00:00+01:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "27", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14.5" } ]
[]
[ { "azi": "319.47", "dTim": "2013-03-30T00:00:00+01:00", "incl": "2.46", "md": "485.3", "tvd": "485.2" }, { "azi": "319.82", "dTim": "2013-03-30T00:00:00+01:00", "incl": "2.57", "md": "522.7", "tvd": "522.6" }, { "azi": "325.09", "dTim": "2013-03-30T00:00:00+01:00", "incl": "2.48", "md": "563.1", "tvd": "562.9" }, { "azi": "280.95", "dTim": "2013-03-30T00:00:00+01:00", "incl": "1.5", "md": "651.9", "tvd": "651.6" }, { "azi": "324.39", "dTim": "2013-03-30T00:00:00+01:00", "incl": "2.57", "md": "603.5", "tvd": "603.3" }, { "azi": "292.15", "dTim": "2013-03-30T00:00:00+01:00", "incl": "1.68", "md": "644", "tvd": "643.8" }, { "azi": "266.71", "dTim": "2013-03-30T00:00:00+01:00", "incl": "2.45", "md": "692.4", "tvd": "692.1" }, { "azi": "240.45", "dTim": "2013-03-30T00:00:00+01:00", "incl": "5.45", "md": "732.9", "tvd": "732.5" }, { "azi": "234.01", "dTim": "2013-03-30T00:00:00+01:00", "incl": "8.06", "md": "773", "tvd": "772.3" } ]
[ { "comments": "Ran in hole with 26\" bottom hole assembly on 5 1/2\" drill pipe from 230m MD to 406m MD. Observed resistance at 406m MD. Attempted to pass restriction with 10MT - no go.", "dTimEnd": "2013-03-29T01:30:00+01:00", "dTimStart": "2013-03-29T00:00:00+01:00", "md": "406", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Established circulation with 2000 lpm and 30 bar. Attempted to pass restriction with 2000 lpm and 30 bar - no go. Increased flow to 3000 lpm and 90 bar. Washed in hole with 26\" bottom hole assembly on 5 1/2\" drill pipe with 3000 lpm and 90 bar from 406m MD to 454m MD. Tagged bottom with 10 MT.", "dTimEnd": "2013-03-29T02:30:00+01:00", "dTimStart": "2013-03-29T01:30:00+01:00", "md": "454", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Performed survey with GyroTrak.\n\nSurvey station (m) Inclination (deg) Azi (deg)\n 426.7 2.55 313.14\n", "dTimEnd": "2013-03-29T02:45:00+01:00", "dTimStart": "2013-03-29T02:30:00+01:00", "md": "454", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Drilled 26\" hole from 454m MD to 469m MD with 4500 lpm, 152 bar, 1.12 sg ECD, 40 surface RPM (130 total RPM), 4-9 kNm, 2-8 MT.\n\nPumped 10m3 hi-visc pill for every single.\n\nAverage ROP: 12 m/hr.\n\nPerformed survey with GyroTrak.\nSurvey station (m) Inclination (deg) Azi (deg)\n 444.6 2.46 316.30\n", "dTimEnd": "2013-03-29T04:00:00+01:00", "dTimStart": "2013-03-29T02:45:00+01:00", "md": "469", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 26\" hole from 469m MD to 639m MD with 4500 lpm, 152-162 bar, 1.12-1.14 sg ECD, 40-60 surface RPM (130-150 total RPM), 4-12 kNm, 2-15 MT.\n\nPumped 10m3 hi-visc pill for every single.\nGyro performed every stand.\n\nAverage ROP: 17.9 m/hr", "dTimEnd": "2013-03-29T13:30:00+01:00", "dTimStart": "2013-03-29T04:00:00+01:00", "md": "646", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Slided and oriented 26\" hole from 639m MD to 650m MD with 4500 lpm, 162-165 bar, 1.12 sg ECD, 5-10MT.\n\nAverage ROP: 11 m/hr", "dTimEnd": "2013-03-29T14:30:00+01:00", "dTimStart": "2013-03-29T13:30:00+01:00", "md": "650", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 26\" hole from 650m MD to 674m MD with 4500 lpm, 162-163 bar, 1.12 sg ECD, 60 surface RPM (150 total RPM), 6-9 kNm, 6-15 MT.\n\nPumped 10m3 hi-visc pill for every single.\n\nAverage ROP: 16 m/hr\n", "dTimEnd": "2013-03-29T16:00:00+01:00", "dTimStart": "2013-03-29T14:30:00+01:00", "md": "674", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and oriented 26\" hole from 674m MD to 793m MD with 4500 lpm, 162-168 bar, 1.12-1.14 sg ECD, 60 surface RPM (150 total RPM), 6-13 kNm, 5-17MT.\n\nPumped 10m3 hi-visc pill for every single.\n\nAverage ROP: 14.9 m/hr", "dTimEnd": "2013-03-30T00:00:00+01:00", "dTimStart": "2013-03-29T16:00:00+01:00", "md": "793", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_03_31
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-30T00:00:00+01:00
2013-03-31T00:00:00+01:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "16.7", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-03-31T00:00:00+01:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "309", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill and orient 26\" hole.", "hpht": "0", "md": "1102", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "25", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Drilled and oriented 26\" hole from 793m MD to 1102m MD.", "tightWell": "0", "tvd": "1095", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-31T00:00:00+01:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "27", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14.5" } ]
[]
[ { "azi": "238.43", "dTim": "2013-03-31T00:00:00+01:00", "incl": "11.55", "md": "813.2", "tvd": "812" }, { "azi": "251.76", "dTim": "2013-03-31T00:00:00+01:00", "incl": "12.87", "md": "853.8", "tvd": "851.6" }, { "azi": "260.17", "dTim": "2013-03-31T00:00:00+01:00", "incl": "12.46", "md": "894.2", "tvd": "891.1" }, { "azi": "261.74", "dTim": "2013-03-31T00:00:00+01:00", "incl": "10.59", "md": "934.5", "tvd": "930.5" }, { "azi": "266.13", "dTim": "2013-03-31T00:00:00+01:00", "incl": "10.64", "md": "967.6", "tvd": "963.1" }, { "azi": "273.81", "dTim": "2013-03-31T00:00:00+01:00", "incl": "10.71", "md": "1015.7", "tvd": "1010.4" }, { "azi": "275.02", "dTim": "2013-03-31T00:00:00+01:00", "incl": "10.6", "md": "1056.1", "tvd": "1050.1" }, { "azi": "287.17", "dTim": "2013-03-31T00:00:00+01:00", "incl": "12.58", "md": "1095.7", "tvd": "1088.9" } ]
[ { "comments": "Slided and oriented 26\" hole from 793m MD to 850m MD with 4500 lpm, 152-163 bar, 1.09-1.10 sg ECD, 8-20MT.\n\nPumped 10m3 hi-visc pill for every single.\n\nAverage ROP: 9,5 m/hr\n", "dTimEnd": "2013-03-30T06:00:00+01:00", "dTimStart": "2013-03-30T00:00:00+01:00", "md": "850", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Slided and oriented 26\" hole prior to entering Utsira formation from 850m MD to 885m MD with 4500 lpm, 163-174 bar, 1.09-1.13 sg ECD, 7-20MT.\n\nPumped 10m3 hi-visc pill for every single.\n\nAverage ROP: 10 m/hr\n\nEntered Utsira Fm at 885m MD.", "dTimEnd": "2013-03-30T09:30:00+01:00", "dTimStart": "2013-03-30T06:00:00+01:00", "md": "885", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and oriented 26\" hole from 885m MD to 1071m MD with 3000 lpm, 88-94 bar, 1.13-1.16 sg ECD, 30 surface RPM (120 total RPM), 3-14 kNm, 4-15 MT.\n\nObserved occational hard stringers.\nPumped 10m3 hi-visc pill for every single.\n\nAverage ROP: 19.6 m/hr\n\nBase Utsira Fm at 1071m MD.", "dTimEnd": "2013-03-30T19:00:00+01:00", "dTimStart": "2013-03-30T09:30:00+01:00", "md": "1071", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Slided and oriented 26\" hole from 1071m MD to 1102m MD with 4500 lpm, 171-176 bar, 1.09-1-13 sg ECD, 15-20 MT.\n\nObserved sticky formation and problems maintaining toolface.\n\nPumped 10m3 hi-visc pill for every single.\nReamed every stand prior to taking connection.\n\nAverage ROP: 6.2 m/hr", "dTimEnd": "2013-03-31T00:00:00+01:00", "dTimStart": "2013-03-30T19:00:00+01:00", "md": "1102", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_01
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-03-31T00:00:00+01:00
2013-04-01T00:00:00+02:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "17", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-01T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "243", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Circulate hole clean.\nDisplace open hole volume to 1.35 sg KCl mud.\nPull out of hole with 26\" bottom hole assembly.\nRig up to run 20\" casing.", "hpht": "0", "md": "1345", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "26", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Drilled and oriented 26\" hole from 1115m MD to 1345m MD.", "tightWell": "0", "tvd": "1324.5", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-03-31T08:00:00+02:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "32", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14" } ]
[]
[ { "azi": "292.51", "dTim": "2013-04-01T00:00:00+02:00", "incl": "17.73", "md": "1136.3", "tvd": "1128" }, { "azi": "289.22", "dTim": "2013-04-01T00:00:00+02:00", "incl": "22.38", "md": "1176.7", "tvd": "1166" }, { "azi": "286.77", "dTim": "2013-04-01T00:00:00+02:00", "incl": "22.25", "md": "1209.5", "tvd": "1196.3" }, { "azi": "283.62", "dTim": "2013-04-01T00:00:00+02:00", "incl": "23.65", "md": "1256.5", "tvd": "1239.6" }, { "azi": "284.95", "dTim": "2013-04-01T00:00:00+02:00", "incl": "20.95", "md": "1298.2", "tvd": "1278.2" }, { "azi": "283.12", "dTim": "2013-04-01T00:00:00+02:00", "incl": "21.87", "md": "1338.7", "tvd": "1315.9" }, { "azi": "283.32", "dTim": "2013-04-01T00:00:00+02:00", "incl": "22.86", "md": "1344.3", "tvd": "1321.1" } ]
[]
[]
15_9_F_11_T2_2013_04_02
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-01T00:00:00+02:00
2013-04-02T00:00:00+02:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "17.1", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-02T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "20", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Retrieve CTS.\nRig up casing running equipment.\nRun 26\" casing.", "hpht": "0", "md": "1365", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "27", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Drilled and oriented 26\" hole from 1345m MD to 1365m MD.\nCirculated hole clean.\nDisplaced open hole volume to 1.35 sg KCl mud.\nPulled out of hole with 26\" bottom hole assembly from 1365m MD to 144m MD.", "tightWell": "0", "tvd": "1340.5", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[]
[]
[]
[ { "comments": "Slided and oriented 26\" hole from 1345m MD to 1359m MD with 4500 lpm, 171-175 bar, 1.09-1.10 sg ECD, 12-18 MT.\n\nPumped 10m3 hi-visc pill for every single.\nReamed every stand prior to taking connection.\n\nAverage ROP: 7.0 m/hr", "dTimEnd": "2013-04-01T02:00:00+02:00", "dTimStart": "2013-04-01T00:00:00+02:00", "md": "1359", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Slided and oriented 26\" hole from 1359m MD to 1365m MD with 4500 lpm, 171-176 bar, 1.09-1.10 sg ECD, 12-18 MT.\n\nObserved hard formation.\nBase Skade Fm verified to 1330m MD. Section TD set to 1365m MD.\n\nAverage ROP: 4.5 m/hr", "dTimEnd": "2013-04-01T03:30:00+02:00", "dTimStart": "2013-04-01T02:00:00+02:00", "md": "1365", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Circulated hole clean with 4500-4800 lpm, 172-196 bar and 80 RPM. \n\nPumped 2 x 30m3 hi-visc sweeps and circulated 3 x bottoms up.", "dTimEnd": "2013-04-01T09:30:00+02:00", "dTimStart": "2013-04-01T03:30:00+02:00", "md": "1365", "phase": "fixed", "proprietaryCode": "drilling -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran in hole and tagged TD with 5MT. Displaced open hole volume with 1.35 sg KCl mud at 4800 lpm, 195 bar and 80 rpm. Observed problems with suction on mud pumps.", "dTimEnd": "2013-04-01T12:00:00+02:00", "dTimStart": "2013-04-01T09:30:00+02:00", "md": "1365", "phase": "fixed", "proprietaryCode": "drilling -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with 26\" bottom hole assembly from 1365m MD to 460m MD. Observed tight hole at 460m MD. Attempted to get past restriction with maximum 30MT overpull - no go.", "dTimEnd": "2013-04-01T15:30:00+02:00", "dTimStart": "2013-04-01T12:00:00+02:00", "md": "460", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Established circulation with KCl mud at 500 lpm. Attempted to lubricate out of hole with 26\" bottom hole assembly with 500 lpm and 10 rpm - no go.", "dTimEnd": "2013-04-01T16:00:00+02:00", "dTimStart": "2013-04-01T15:30:00+02:00", "md": "460", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Established circulation with seawater at 4000 lpm, 170 bar and 30 rpm. Reamed stand from 472m MD to 432m MD. Continued to circulate hole clean with 4000 lpm, 170-175 bar and 30 rpm. Circulation interupted by mud pumps shutting down.", "dTimEnd": "2013-04-01T17:30:00+02:00", "dTimStart": "2013-04-01T16:00:00+02:00", "md": "460", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot and repaired eletrical fault on mud pumps.\n\nMeanwhile: Pulled out of hole with 26\" bottom hole assembly from 460m MD to 350m MD to check hole conditions. No overpull observed.", "dTimEnd": "2013-04-01T18:30:00+02:00", "dTimStart": "2013-04-01T17:30:00+02:00", "md": "460", "phase": "fixed", "proprietaryCode": "interruption -- maintain", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Ran in hole with 26\" bottom hole assembly from 350m MD to 460m MD.", "dTimEnd": "2013-04-01T19:30:00+02:00", "dTimStart": "2013-04-01T18:30:00+02:00", "md": "460", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Displaced remaining open hole volume with 1.35 sg KCl mud at 4000 lpm, 10 rpm.", "dTimEnd": "2013-04-01T20:15:00+02:00", "dTimStart": "2013-04-01T19:30:00+02:00", "md": "460", "phase": "fixed", "proprietaryCode": "drilling -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled out of hole with 26\" bottom hole assembly from 460m MD to 185m MD. Informed Production Control Room to shut down producing wells according to SIMOPS.", "dTimEnd": "2013-04-01T21:15:00+02:00", "dTimStart": "2013-04-01T20:15:00+02:00", "md": "185", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed scheduled service on top drive and pipe racking system. Performed pre-job meeting prior to lay down / rack back 26\" bottom hole assembly.\n\nMeanwhile: Shut down producing wells (F-12 and F-14)", "dTimEnd": "2013-04-01T23:30:00+02:00", "dTimStart": "2013-04-01T21:15:00+02:00", "md": "185", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Racked back 5 1/2\" heavy weight drill pipe in derrick from 185m MD to 144m MD.", "dTimEnd": "2013-04-02T00:00:00+02:00", "dTimStart": "2013-04-01T23:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_03
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-02T00:00:00+02:00
2013-04-03T00:00:00+02:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "17.4", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-03T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "0", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run 20\" casing.", "hpht": "0", "md": "1365", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "28", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Racked back and laid down 26\" bottom hole assembly.\nRigged up to run 20\" casing.\nPicked up and made up shoe joint, float collar joint and one intermediate joint with thread lock.\nTroubleshooting and repairing of pipe deck machine (PDM)", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-04-02T08:00:00+02:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "32", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Broke out and racked back 5 1/2\" heavy weight drill pipe and 9 1/2\" drill collars in derrick from 144m MD to 60m MD.", "dTimEnd": "2013-04-02T03:00:00+02:00", "dTimStart": "2013-04-02T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Downloaded MWD.", "dTimEnd": "2013-04-02T03:30:00+02:00", "dTimStart": "2013-04-02T03:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke out and laid down OnTrak, GyroTrak and motor to deck.", "dTimEnd": "2013-04-02T06:45:00+02:00", "dTimStart": "2013-04-02T03:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed prejob meeting prior to rig up casing running equipment.", "dTimEnd": "2013-04-02T07:30:00+02:00", "dTimStart": "2013-04-02T06:45:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Made up cement stand and racked back in derrick. Rigged up to run 20\" casing. Removed drilling bails and elevators, installed casing bails and elevators. Observed that 20\" casing tong door had problems opening and closing.", "dTimEnd": "2013-04-02T14:30:00+02:00", "dTimStart": "2013-04-02T07:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Retrieved CTS and hoses from seabed. \n\nMeanwhile: Performed prejob meeting prior to run 20\" casing.", "dTimEnd": "2013-04-02T17:00:00+02:00", "dTimStart": "2013-04-02T14:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed 20\" casing bushings and slips.", "dTimEnd": "2013-04-02T18:00:00+02:00", "dTimStart": "2013-04-02T17:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up shoe joint on deck. Verified float by hosing water through it. Made up shoe joint and float collar joint. Thread locked to connection. Experienced problems with Pipedeck Machine (PDM). Claw did not open. Not able to pick up casing joints from pipedeck to catwalk.", "dTimEnd": "2013-04-02T20:30:00+02:00", "dTimStart": "2013-04-02T18:00:00+02:00", "md": "36", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot and repaired Pipedeck Machine (PDM). Found tilt function and boom extension not working.\n\nMeanwhile: Performed general maintanence.", "dTimEnd": "2013-04-03T00:00:00+02:00", "dTimStart": "2013-04-02T20:30:00+02:00", "md": "36", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" } ]
[]
15_9_F_11_T2_2013_04_04
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-03T00:00:00+02:00
2013-04-04T00:00:00+02:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "17.7", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-04T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run and land 20\" casing.\nCement 20\" casing.\n", "hpht": "0", "md": "1365", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "29", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Troubleshoot and repaired PDM (Pipe Deck Machine) Replaced solenoid valve.\nRan in hole with 20\" casing from 36 m MD to 656 m MD.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-04-03T08:00:00+02:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "32", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14" } ]
[]
[]
[ { "comments": "Troubleshoot and repaired PDM (Pipe Deck Machine) Replaced solenoid valve.\n\nMeanwhile: Performed general maintenance.", "dTimEnd": "2013-04-03T03:00:00+02:00", "dTimStart": "2013-04-03T00:00:00+02:00", "md": "36", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Ran in hole with 20\" casing from 36 m MD to 150 m MD. Average running speed 2,2 joints/hour.\nFilled every joint.", "dTimEnd": "2013-04-03T07:00:00+02:00", "dTimStart": "2013-04-03T03:00:00+02:00", "md": "150", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting with oncoming crews prior to run 20\" casing.\nChecked all equipment and barriers. \n\n", "dTimEnd": "2013-04-03T07:30:00+02:00", "dTimStart": "2013-04-03T07:00:00+02:00", "md": "188", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and installed casing circulation tool. Tested circulation tool, experienced TDS wash pipe leaking.", "dTimEnd": "2013-04-03T09:30:00+02:00", "dTimStart": "2013-04-03T07:30:00+02:00", "md": "188", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Replaced TDS wash pipe and pressure tested same to 100 bar / 10 minutes.\n\nMeanwhile changed leaking hydraulic fittings on elevators.", "dTimEnd": "2013-04-03T11:30:00+02:00", "dTimStart": "2013-04-03T09:30:00+02:00", "md": "188", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran in hole with 20\" casing from 188 m MD to 201 m MD.", "dTimEnd": "2013-04-03T12:30:00+02:00", "dTimStart": "2013-04-03T11:30:00+02:00", "md": "201", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cross threaded box joint 105 with pin joint 104, unable to obtain required torque. Decided to lay down both joints. Observed problems with laying down casing joints using HTS.", "dTimEnd": "2013-04-03T13:00:00+02:00", "dTimStart": "2013-04-03T12:30:00+02:00", "md": "201", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Decided to lay down joints manually using deck crane.\nPerformed toolbox talk prior to laying down the joints.\nLaid out 2 x damaged joint to deck using deck crane.", "dTimEnd": "2013-04-03T14:00:00+02:00", "dTimStart": "2013-04-03T13:00:00+02:00", "md": "201", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Ran in hole with 20\" casing from 201 m MD to 656 m MD. Average running speed 3-5 joints/hour.\nFilled every joint with SW.\nPerformed pre-job meeting with oncoming crews prior to run 20\".\nChecked all equipment and barriers. \n", "dTimEnd": "2013-04-04T00:00:00+02:00", "dTimStart": "2013-04-03T14:00:00+02:00", "md": "656", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_05
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-04T00:00:00+02:00
2013-04-05T00:00:00+02:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "18.1", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-05T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Cement 20\" casing.\nRelease WHH running tool and POOH.\nPrepare to run HP drilling riser.\n", "hpht": "0", "md": "1365", "mdCsgLast": "202.3", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "30", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Ran 20\" casing from 656 m to 1208 m.\nRan 20\" casing on 5 1/2\" HWDP landing string from 1208 m to 1344 m.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "202", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-04-04T08:00:00+02:00", "density": "1.35", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "455", "mudClass": "water based", "presBopRating": "345", "pv": "32", "tempHthp": null, "type": "KCl/Polymer/GEM", "visFunnel": "-999.99", "yp": "14" }, { "dTim": "2013-04-05T00:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": null, "md": "-999.99", "mudClass": "other", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "Seawater", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Ran in hole with 20\" casing from 656 m MD to 1208 m MD. Average running speed 5 joints/hour.\nFilled every joint with SW.", "dTimEnd": "2013-04-04T09:00:00+02:00", "dTimStart": "2013-04-04T00:00:00+02:00", "md": "1208", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting.\nRigged down casing circulation tool.\nRemoved 20\" casing elevator and installed 5 1/2\" DP elevator.", "dTimEnd": "2013-04-04T10:30:00+02:00", "dTimStart": "2013-04-04T09:00:00+02:00", "md": "1208", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and made up 18 3/4\" wellhead with 20\" casing pup to string.\nNot able to obtain correct torque turn graph. Decided to replace wellhead with backup.", "dTimEnd": "2013-04-04T11:00:00+02:00", "dTimStart": "2013-04-04T10:30:00+02:00", "md": "1208", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke out wellhead from string and laid down same to deck.\nPulled out of hole with 20\" casing string from 1208 m to 1195 m and broke out joint with damaged box threads, laid down same to deck.\nPicked up and made up new 20\" casing joint and ran in hole to 1208 meter.\nChanged to 5 1/2\" handling equipment.\nPrepared backup wellhead on HTS, made up same to running tool.\nPicked up and made up backup wellhead assembly.\nInstalled plug set in backup wellhead assembly.", "dTimEnd": "2013-04-04T17:00:00+02:00", "dTimStart": "2013-04-04T11:00:00+02:00", "md": "1208", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Removed casing bushings and slips.\nRan in hole with 20\" casing on landing string from 1208 m to 1223 m. \nInstalled 5 1/2\" slips.", "dTimEnd": "2013-04-04T17:30:00+02:00", "dTimStart": "2013-04-04T17:00:00+02:00", "md": "1223", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged down 20\" casing handling equipment.\nMoved casing string at regular intervals, no overpull or down weight observed.", "dTimEnd": "2013-04-04T19:00:00+02:00", "dTimStart": "2013-04-04T17:30:00+02:00", "md": "1223", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting.\nReplaced 20 ft bails with drilling bails.\nInstalled BX elevator dressed for 5 1/2\" DP.", "dTimEnd": "2013-04-04T20:00:00+02:00", "dTimStart": "2013-04-04T19:00:00+02:00", "md": "1223", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran in hole with 20\" casing on 5 1/2\" HWDP landing string from 1223 m MD to 1327 m MD.\nRigged up chain hoists in moonppol to center wellhead while running same through deck levels of platform.\nAt 1327 meter sat down 20 Ton. \nPulled back to 1317 meter and connected TDS to string.\n", "dTimEnd": "2013-04-04T23:00:00+02:00", "dTimStart": "2013-04-04T20:00:00+02:00", "md": "1327", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Established circulation in increments of 300 liter/min.\nWashed down 20\" casing from 1327 m to 1344 m with 1000 liter/min, 30 bar. No excessive weight observed.", "dTimEnd": "2013-04-05T00:00:00+02:00", "dTimStart": "2013-04-04T23:00:00+02:00", "md": "1344", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_06
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-05T00:00:00+02:00
2013-04-06T00:00:00+02:00
normal
2018-05-03T13:51:27+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "18.2", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-06T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Rig up and prepare for running HPDR.\nRun HPDR.", "hpht": "0", "md": "1365", "mdCsgLast": "1357.7", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "31", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Cemented 20\" casing.\nReleased WHH RT and POOH with same.\nRigged up and prepared for running HPDR.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-04-06T00:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": null, "md": "-999.99", "mudClass": "other", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "Seawater", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Picked up and made up cement stand.\nNot able to spin in TDS.", "dTimEnd": "2013-04-05T00:30:00+02:00", "dTimStart": "2013-04-05T00:00:00+02:00", "md": "1317", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot TDS spinning problem.\n\nMeanwhile: \nRacked back cement stand.\nReciprocated 20\" casing string.\nMade up cement stand into string.", "dTimEnd": "2013-04-05T01:30:00+02:00", "dTimStart": "2013-04-05T00:30:00+02:00", "md": "1317", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Established circulation in increments of 300 liter/min.\nWashed down 20\" casing from 1344 m to 1358 m with 1000 liter/min, 30 bar. No excessive weight observed.\nRecorded up / down weights 245 / 183 Ton.", "dTimEnd": "2013-04-05T02:00:00+02:00", "dTimStart": "2013-04-05T01:30:00+02:00", "md": "1358", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Landed 20\" casing at 1358 meter by setting down 15 Ton on hanger.\nPerformed over pull test to 270 Ton. ( 25 Ton overpull)", "dTimEnd": "2013-04-05T02:30:00+02:00", "dTimStart": "2013-04-05T02:00:00+02:00", "md": "1358", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Started production on F-12.\nCirculated 250 m3 with 2300 liter/min, 40 bar. \nLined up, flushed and pressure tested surface lines to 345 bar for 10 min.", "dTimEnd": "2013-04-05T05:00:00+02:00", "dTimStart": "2013-04-05T02:30:00+02:00", "md": "1358", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Dropped ball for bottom wiper plug.\nApplied 20 bar against lo-torq valve, opened same to verify lineup.\nMixed and pumped 308 m3 of 1,56 SG lead cement slurry with 1000-1050 l/min, 22-19 bar. \nMixed and pumped 30 m3 of 1,92 SG tail cement slurry with 840 l/min, 17 bar. \nReleased top dart and reset stroke counters.\n", "dTimEnd": "2013-04-05T11:00:00+02:00", "dTimStart": "2013-04-05T05:00:00+02:00", "md": "1358", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Displaced 3000 liter SW from cement unit using cement pump. \nDid not observe top plug shear after +/- 820 liters as prognosed.\nContinued to displace with SW using rig pumps at 3900 liter/min, 45-50 bar.\nAfter 2990 liter pumped observed pressure spike of 111 bar. Indicating top plug sheared.\nUnder displaced with 10 m3, did not bump plug.\nTotal displacement 201 m3 SW.\nBleed back pressure to trip tank and monitored for backflow, no flow observed.\nDisconnected cement hose and removed same.\n", "dTimEnd": "2013-04-05T13:00:00+02:00", "dTimStart": "2013-04-05T11:00:00+02:00", "md": "1358", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Released 18 3/4\" CART tool from hanger.\nPerformed pre-job meeting prior to laying out cement head and CART.", "dTimEnd": "2013-04-05T13:30:00+02:00", "dTimStart": "2013-04-05T13:00:00+02:00", "md": "1358", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Laid down cement head with 5 1/2\" HWDP single down on HTS.\nConnected TDS and circulated 2 ea. sponge balls through pipe.\nPOOH with 18 3/4\" CART on 5 1/2\" HWDP from 140 meter to surface.\nLaid down 18 3/4\" CART to cantilever.", "dTimEnd": "2013-04-05T15:30:00+02:00", "dTimStart": "2013-04-05T13:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held tool box talk with ROV and deck crew.\nAssisted ROV and deck crew with installing riser guide funnel.\n\nMeanwhile:\nDismantled TDS washpipe.\nCleaned and cleared rigfloor and prepared to spot equipment for HPDR running.\nInstalled teflon riser guides in hole openings on centralizer and tension decks.", "dTimEnd": "2013-04-05T20:00:00+02:00", "dTimStart": "2013-04-05T15:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to pickup and prepare HPDR equipment.", "dTimEnd": "2013-04-05T20:30:00+02:00", "dTimStart": "2013-04-05T20:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up Claxton tool and torqued up handling pup connection, laid down same to cantilever.\nMeanwhile:\nSpotted riser equipment on cantilever, centralizer and tension decks.", "dTimEnd": "2013-04-05T22:00:00+02:00", "dTimStart": "2013-04-05T20:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed tension ring on centralizer deck.\nMeanwhile:\nOrganized riser joints on cantilever.\nConnected BOP joint to Claxton tool.\n", "dTimEnd": "2013-04-06T00:00:00+02:00", "dTimStart": "2013-04-05T22:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_07
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-06T00:00:00+02:00
2013-04-07T00:00:00+02:00
normal
2018-05-03T13:51:28+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "18.8", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-07T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run and land HPDR.", "hpht": "0", "md": "1365", "mdCsgLast": "1357.7", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "32", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Rigged up and ran HPDR to 21 meter.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-04-07T00:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": null, "md": "-999.99", "mudClass": "other", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "Seawater", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Rigged up and prepared to run HPDR.\nPicked up HPU unit and tested Claxton running tool on cantilever.\nConnected Claxton tool to top riser joint, pressure tested same to 35 bar, OK.\n\nPerformed pre-job meeting with oncoming crews.\n", "dTimEnd": "2013-04-06T07:30:00+02:00", "dTimStart": "2013-04-06T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed master bushings and installed riser spider. \nFunction tested riser spider and removed lifting bridal.", "dTimEnd": "2013-04-06T09:00:00+02:00", "dTimStart": "2013-04-06T07:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to run HPDR.", "dTimEnd": "2013-04-06T09:30:00+02:00", "dTimStart": "2013-04-06T09:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up TBC / Stress joint and ran through rotary, landed same in spider.", "dTimEnd": "2013-04-06T10:30:00+02:00", "dTimStart": "2013-04-06T09:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up lower riser pup joint.\nPrepared seal faces on joint connection and landed same onto TBC / Stress joint in rotary.", "dTimEnd": "2013-04-06T12:00:00+02:00", "dTimStart": "2013-04-06T10:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Not able to make up flange between riser joints due to studs too long.\nTechnical Team fabricated spacer washer for shimming hydraulic jacks.\n\nMeanwhile:\nRigged up wires for guide line system in moonpool.\nPrepared next riser joints on cantilever deck.", "dTimEnd": "2013-04-06T17:30:00+02:00", "dTimStart": "2013-04-06T12:00:00+02:00", "md": "12", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Made up connection between TBC / Stress joint and lower riser pup joint.\nInstalled fairings (Anti collision protection).\n\nMeanwhile:\nInstalled lift nubbin on riser joint #4.", "dTimEnd": "2013-04-06T21:00:00+02:00", "dTimStart": "2013-04-06T17:30:00+02:00", "md": "12", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Function tested TBC in moonpool, functions OK.\nObserved minor leak from hotstab dummy with valves on TBC valve panel in open position.\nChecked position of valves and confirmed with town.\nShut valves on TBC valve panel. No leak observed.", "dTimEnd": "2013-04-06T23:00:00+02:00", "dTimStart": "2013-04-06T21:00:00+02:00", "md": "12", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran in hole from 12 m to 21 m with HPDR.\nPicked up joint #4, removed lift nubbin and checked seal faces.", "dTimEnd": "2013-04-07T00:00:00+02:00", "dTimStart": "2013-04-06T23:00:00+02:00", "md": "21", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_08
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-07T00:00:00+02:00
2013-04-08T00:00:00+02:00
normal
2018-05-03T13:51:28+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "19.4", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-08T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run and land HPDR.\nNipple up BOP. ", "hpht": "0", "md": "1365", "mdCsgLast": "1357.7", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "33", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Ran HPDR.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-04-08T00:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": null, "md": "-999.99", "mudClass": "other", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "Seawater", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Made up connection between lower riser pup joint and joint #4.\nInstalled fairings (Anti collision protection).\n\nMeanwhile:\nInstalled lifting nubbin on joint #3.", "dTimEnd": "2013-04-07T01:30:00+02:00", "dTimStart": "2013-04-07T00:00:00+02:00", "md": "21", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran in hole with riser.\nConnected guide line wires to guide ring on stress joint.\nContinued to RIH with riser from 21 m to 35 m.", "dTimEnd": "2013-04-07T04:30:00+02:00", "dTimStart": "2013-04-07T01:30:00+02:00", "md": "35", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up joint #3, removed lift nubbin and checked seal faces.\nMade up connection between riser joints #3 and #4 and tested same.\nInstalled fairings (Anti collision protection).\nRIH with riser from 35 m to 50 m.\n", "dTimEnd": "2013-04-07T07:00:00+02:00", "dTimStart": "2013-04-07T04:30:00+02:00", "md": "50", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "WOW due to significant sea above 2 meter.\n\nMeanwhile:\nWorked with installation of TDS washpipe.\nPrepared HPDR joints on cantilever.", "dTimEnd": "2013-04-07T09:00:00+02:00", "dTimStart": "2013-04-07T07:00:00+02:00", "md": "50", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up joint #6, removed lift nubbin and checked seal faces.\nMade up connection between riser joints #6 and #3 and tested same.\nNot able to obtain pressure test.", "dTimEnd": "2013-04-07T12:00:00+02:00", "dTimStart": "2013-04-07T09:00:00+02:00", "md": "50", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke out connection between riser joints #6 and #3 and inspected same.\nFound o-ring missing.\nInstalled o-ring in outer groove.\nMade up connection between riser joints #6 and #3 and re-tested same to 35 bar, test ok.\n", "dTimEnd": "2013-04-07T18:00:00+02:00", "dTimStart": "2013-04-07T12:00:00+02:00", "md": "50", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Installed fairings (Anti collision protection).\nRIH with HP drilling riser through splash zone from 50 m to 65 m.", "dTimEnd": "2013-04-07T20:30:00+02:00", "dTimStart": "2013-04-07T18:00:00+02:00", "md": "65", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up joint #7, removed lift nubbin and checked seal faces.\nMade up connection between riser joints #7 and #6 and tested same.\nNot able to obtain pressure test.", "dTimEnd": "2013-04-07T22:00:00+02:00", "dTimStart": "2013-04-07T20:30:00+02:00", "md": "65", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Broke out connection between riser joints #6 and #7 and inspected same.\nReplaced o-ring.", "dTimEnd": "2013-04-08T00:00:00+02:00", "dTimStart": "2013-04-07T22:00:00+02:00", "md": "65", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "operation failed" } ]
[]
15_9_F_11_T2_2013_04_09
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-08T00:00:00+02:00
2013-04-09T00:00:00+02:00
normal
2018-05-03T13:51:28+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-09T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run and land HPDR.\nTest riser and casing.\nNipple up BOP.", "hpht": "0", "md": "1365", "mdCsgLast": "1357.7", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "34", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Ran HPDR.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-04-08T12:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": null, "md": "-999.99", "mudClass": "other", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "Seawater", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Made up connection between riser joints #6 and #7 and re-tested same to 35 bar, test ok.", "dTimEnd": "2013-04-08T00:30:00+02:00", "dTimStart": "2013-04-08T00:00:00+02:00", "md": "65", "phase": "fixed", "proprietaryCode": "interruption -- wait", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "RIH with HP Drilling Riser from 65 m to 103 m.", "dTimEnd": "2013-04-08T05:30:00+02:00", "dTimStart": "2013-04-08T00:30:00+02:00", "md": "103", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up handling equipment prior to pick up tension joint. C-plate, long bails and elevators.", "dTimEnd": "2013-04-08T06:30:00+02:00", "dTimStart": "2013-04-08T05:30:00+02:00", "md": "103", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior to make up tension joint.\nPicked up tension joint, removed lift nubbin and checked seal faces, polished light scratches on tension joint sealface.\nMade up connection between riser joints and tested same.\nInstalled fairings (Anti collision protection).\nRIH with HPDR from 103 m to 121 m.\n\nMeanwhile:\nInstalled second guide wire on WHH.", "dTimEnd": "2013-04-08T13:30:00+02:00", "dTimStart": "2013-04-08T06:30:00+02:00", "md": "121", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Rigged up handling equipment prior to pick up BOP joint, drilling bails and BX elevators.", "dTimEnd": "2013-04-08T14:30:00+02:00", "dTimStart": "2013-04-08T13:30:00+02:00", "md": "121", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up BOP joint, removed lift nubbin and checked seal faces.\nMade up connection between BOP and tension joints, tested same.\n\nMeanwhile:\nPrepared landing joint with side entry sub.\nPrepared equipment for installation of tension ring.\n", "dTimEnd": "2013-04-08T17:00:00+02:00", "dTimStart": "2013-04-08T14:30:00+02:00", "md": "121", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed c-plate.\nPrepared to run Claxton tool and BOP joint through rotary.\nRemoved riser spider.\n", "dTimEnd": "2013-04-08T19:30:00+02:00", "dTimStart": "2013-04-08T17:00:00+02:00", "md": "121", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Ran in with HPDR from 121 m to 127 m.\nInstalled master bushing.\n", "dTimEnd": "2013-04-08T20:00:00+02:00", "dTimStart": "2013-04-08T19:30:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior to land riser.\nPicked up and made up landing string to TDS.\nCame down to land riser.\nDue to sideways movement the riser hit top of guide funnel. The funnel fell off the WHH.\n", "dTimEnd": "2013-04-08T21:00:00+02:00", "dTimStart": "2013-04-08T20:00:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting.\nRecovered riser guide funnel to surface for inspection and repair.\n", "dTimEnd": "2013-04-09T00:00:00+02:00", "dTimStart": "2013-04-08T21:00:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "operation failed" } ]
[]
15_9_F_11_T2_2013_04_10
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-09T00:00:00+02:00
2013-04-10T00:00:00+02:00
normal
2018-05-03T13:51:28+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20.2", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-10T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Install HPDR tensioner system.\nRun and nipple up BOP.\nRun wear bushing.\nPick up 17 1/2\" BHA.\n", "hpht": "0", "md": "1365", "mdCsgLast": "1357.7", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "35", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Ran HPDR and landed same.\nTook overpull test of riser.\nPressure tested 20\" casing and riser to 100 bar / 15 minutes.\nCommenced installation of HPDR tensioner system.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": null } ]
[ { "dTim": "2013-04-09T21:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "-999.99", "mudClass": "oil based", "presBopRating": "345", "pv": "29", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "6.5" } ]
[]
[]
[ { "comments": "Recovered riser guide funnel to surface for inspection and repair.\n\nMeanwhile:\nWorked with installation of new washpipe.\n", "dTimEnd": "2013-04-09T03:30:00+02:00", "dTimStart": "2013-04-09T00:00:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Repaired broken spindle on riser guide funnel.\n\nMeanwhile:\nWorked with installation of new washpipe.\n", "dTimEnd": "2013-04-09T06:30:00+02:00", "dTimStart": "2013-04-09T03:30:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Launched and installed riser guide funnel on WHH.", "dTimEnd": "2013-04-09T10:30:00+02:00", "dTimStart": "2013-04-09T06:30:00+02:00", "md": "127", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Held pre-job meeting prior to land riser.\nCame down with riser and stabilized TBC around WHH.\nReleased riser guide funnel from WHH.\nOriented TBC and landed same with 22 ton down weight.", "dTimEnd": "2013-04-09T14:00:00+02:00", "dTimStart": "2013-04-09T10:30:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "ROV installed hot stab into TBC and operated valves to lock position.\nPressured up mini reel 3000 psi / 15 min to lock TBC.\nROV operated valves into park position.", "dTimEnd": "2013-04-09T16:00:00+02:00", "dTimStart": "2013-04-09T14:00:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed overpull test on riser to 15 Ton.\nReplaced hot stab with dummy hot stab.", "dTimEnd": "2013-04-09T17:00:00+02:00", "dTimStart": "2013-04-09T16:00:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior to pressure test riser and 20\" casing.\nRigged up cement hose and lo-torq valve on drill floor.\nAttempted to pressure test lines and hose to 150 bar.\nNot able to obtain line test.", "dTimEnd": "2013-04-09T18:00:00+02:00", "dTimStart": "2013-04-09T17:00:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshot leak in surface lines. \nReplaced lo-torq valve.\nPressure tested lines and hose to 150 bar / 10 min.", "dTimEnd": "2013-04-09T19:30:00+02:00", "dTimStart": "2013-04-09T18:00:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "operation failed" }, { "comments": "Filled riser with SW and evacuated air from system.\nLined up and performed pressure test of riser and 20\" casing to 100 bar / 10 min.", "dTimEnd": "2013-04-09T21:00:00+02:00", "dTimStart": "2013-04-09T19:30:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held pre-job meeting prior to rig up tensioner system.\nWorked with installation of centralizer and boat collision stool.\n\nMeanwhile:\nInstalled new washpipe.", "dTimEnd": "2013-04-10T00:00:00+02:00", "dTimStart": "2013-04-09T21:00:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_11
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-10T00:00:00+02:00
2013-04-11T00:00:00+02:00
normal
2018-05-03T13:51:28+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20.1", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-11T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Test HPDR and BOP connections.\nRun and set seat protector.\nPick up 17 1/2\" drilling BHA and RIH.\nDrill out cement and float.", "hpht": "0", "md": "1365", "mdCsgLast": "1357.7", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "36", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Installed HPDR tensioner system.\nRan and nippled up BOP.\n", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": "139.2" } ]
[ { "dTim": "2013-04-10T12:00:00+02:00", "density": "-999.99", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "-999.99", "mudClass": "oil based", "presBopRating": "345", "pv": "28", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "6" }, { "dTim": "2013-04-10T23:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Reserve pit", "md": "-999.99", "mudClass": "oil based", "presBopRating": "345", "pv": "29", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "6" }, { "dTim": "2013-04-10T23:30:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "-999.99", "mudClass": "other", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "Seawater", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Installed centralizer and boat collision stool.\n\nMeanwhile:\nInstalled new washpipe.", "dTimEnd": "2013-04-10T02:00:00+02:00", "dTimStart": "2013-04-10T00:00:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed tensioner ring and cylinders.\n\nMeanwhile:\nReplaced soloniod valve on TDS spin function.", "dTimEnd": "2013-04-10T09:30:00+02:00", "dTimStart": "2013-04-10T02:00:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting.\nLoad shifted from TDS to tension cylinders.\nFinal tension on cylinders adjusted to 150 Ton.", "dTimEnd": "2013-04-10T11:30:00+02:00", "dTimStart": "2013-04-10T09:30:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Released Claxton tool and pulled back same to drill floor.\nBroke out and laid down Claxton tool to deck.", "dTimEnd": "2013-04-10T13:30:00+02:00", "dTimStart": "2013-04-10T11:30:00+02:00", "md": "139", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Prepared for skidding BOP to wellcenter.\nRigged up scaffolding for accessing NT2 connector.\nHeld toolbox talk prior to skidding and landing BOP.\nSkidded BOP to wellcenter and landed same.\nAt 1600 hrs. started production on well F-12 and F-14.", "dTimEnd": "2013-04-10T16:00:00+02:00", "dTimStart": "2013-04-10T13:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Nippled up BOP, slip joint and diverter systems.", "dTimEnd": "2013-04-11T00:00:00+02:00", "dTimStart": "2013-04-10T16:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_12
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-11T00:00:00+02:00
2013-04-12T00:00:00+02:00
normal
2018-05-03T13:51:28+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "19.4", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-12T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill shoetrack and displace well to 1,40 sg OBM.\nPerform FIT.\nDrill 17 1/2\" hole.", "hpht": "0", "md": "1365", "mdCsgLast": "1357.7", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "37", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Nippled up BOP, slip joint and diverter systems.\nTested BOP and HPDR connections.\nInstalled seat protector\nRIH with 17 1/2\" drilling BHA.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-11T23:30:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "-999.99", "mudClass": "other", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "Seawater", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "Nippled up BOP, slip joint and diverter systems.", "dTimEnd": "2013-04-11T01:30:00+02:00", "dTimStart": "2013-04-11T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with BOP test plug on 5 1/2 DP.\nTested BOP and HPDR connections to 30 bar / 5 min - 345 bar / 10 min.\nPOOH with BOP test plug.\n", "dTimEnd": "2013-04-11T04:30:00+02:00", "dTimStart": "2013-04-11T01:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Made up seat protector and RIH.\nInstalled seat protector and POOH with RT.", "dTimEnd": "2013-04-11T08:00:00+02:00", "dTimStart": "2013-04-11T04:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Installed new type wash pipe.", "dTimEnd": "2013-04-11T09:30:00+02:00", "dTimStart": "2013-04-11T08:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Continued to install new wash pipe. Tested same to 275 bar.", "dTimEnd": "2013-04-11T11:00:00+02:00", "dTimStart": "2013-04-11T09:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up and made up 17 1/2\" drilling BHA and RIH on 5 1/2\" HWDP from surface to 232 meter.", "dTimEnd": "2013-04-11T18:30:00+02:00", "dTimStart": "2013-04-11T11:00:00+02:00", "md": "232", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held toolbox talk.\nPerformed choke drills with both crews.", "dTimEnd": "2013-04-11T20:00:00+02:00", "dTimStart": "2013-04-11T18:30:00+02:00", "md": "232", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Picked up 5 1/2\" DP singles while RIH with 17 1/2\" BHA from 232 m to 473 m. Average tripping speed 120 m/hr.", "dTimEnd": "2013-04-11T22:00:00+02:00", "dTimStart": "2013-04-11T20:00:00+02:00", "md": "473", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 17 1/2\" BHA on 5 1/2\" DP from 473 m to 1159 m. Average tripping speed 343 m/hr.", "dTimEnd": "2013-04-12T00:00:00+02:00", "dTimStart": "2013-04-11T22:00:00+02:00", "md": "1159", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_13
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-12T00:00:00+02:00
2013-04-13T00:00:00+02:00
normal
2018-05-03T13:51:28+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "19.6", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-13T00:00:00+02:00", "dTimDiaHoleStart": "2013-03-23T05:30:00+01:00", "diaHole": "26", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill shoetrack and 3 meter new formation.\nPerform FIT.\nDrill ahead.", "hpht": "0", "md": "1365", "mdCsgLast": "1357.7", "mdDiaHoleStart": "257", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "38", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Drilled shoetrack.", "tightWell": "0", "tvd": "1345.5", "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-12T03:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1365", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8" }, { "dTim": "2013-04-12T12:00:00+02:00", "density": "1.03", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "-999.99", "mudClass": "other", "presBopRating": "345", "pv": "-999.99", "tempHthp": null, "type": "Seawater", "visFunnel": "-999.99", "yp": "-999.99" } ]
[]
[]
[ { "comments": "RIH with 17 1/2\" BHA on 5 1/2\" DP from 1159 m to 1236 m. Average tripping speed 154 m/hr.\nObserved 5 Ton loss in weight at 1236 meter.\nRecorded up / down weights 133 / 115 Ton.", "dTimEnd": "2013-04-12T00:30:00+02:00", "dTimStart": "2013-04-12T00:00:00+02:00", "md": "1236", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Washed / reamed down from 1236 m to 1262 m with 1500 l/min, 19 bar, 20 RPM, 4-8 kNm.\nAt 1262 meter tagged firm cement with 5 Ton", "dTimEnd": "2013-04-12T01:30:00+02:00", "dTimStart": "2013-04-12T00:30:00+02:00", "md": "1262", "phase": "fixed", "proprietaryCode": "drilling -- ream", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled firm cement from 1262 m to 1264,8 m with 3560 l/min, 105 bar, 40 RPM, 6-15 kNm, WOB 4-5 Ton.\nPerformed pre-job meeting prior to displacement job.\nObserved leak on longitudinal flowline on main deck.", "dTimEnd": "2013-04-12T02:30:00+02:00", "dTimStart": "2013-04-12T01:30:00+02:00", "md": "1264.8", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Stopped drilling and repaired leak.", "dTimEnd": "2013-04-12T03:00:00+02:00", "dTimStart": "2013-04-12T02:30:00+02:00", "md": "1264.8", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Drilled top plug from 1264,8 m to 1265,6 m with 3500 l/min, 106 bar, 40 RPM, 6-19 kNm, WOB 4-5 Ton.\nObserved black rubber pieces coming across shakers.", "dTimEnd": "2013-04-12T04:00:00+02:00", "dTimStart": "2013-04-12T03:00:00+02:00", "md": "1265.6", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Displaced well from SW to 1,40 sg OBM with 3530 l/min, 150 bar.\nDiverted SW returns to sea.", "dTimEnd": "2013-04-12T07:00:00+02:00", "dTimStart": "2013-04-12T04:00:00+02:00", "md": "1265.6", "phase": "fixed", "proprietaryCode": "drilling -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Circulated and conditioned OBM while reciprocating string from 1240 m to 1255 m with 20 rpm, 2-6 kNm.\nIncreased pump rate in incremens of 110 l/min to ensure shakers and surface system do not over flow.\n", "dTimEnd": "2013-04-12T11:00:00+02:00", "dTimStart": "2013-04-12T07:00:00+02:00", "md": "1265.6", "phase": "fixed", "proprietaryCode": "drilling -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled firm cement from 1265,6 m to 1356 m with 3000-3520 l/min, 183 bar, 40-90 RPM, 2-10 kNm, WOB 5-10 Ton.\nDrilled bottom wiper plug at 1358 m to 1358,7 m.\nObserved black / red rubber pieces coming across shakers.", "dTimEnd": "2013-04-13T00:00:00+02:00", "dTimStart": "2013-04-12T11:00:00+02:00", "md": "1356", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_14
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-13T00:00:00+02:00
2013-04-14T00:00:00+02:00
normal
2018-05-03T13:51:28+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "19.7", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-14T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "35", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill 17 1/2\".", "hpht": "0", "md": "1400", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "0", "presTestType": null, "reportNo": "39", "ropCurrent": "-999.99", "strengthForm": "0", "sum24Hr": "Drilled shoetrack and 3 meter new formation.\nPerform FIT.\nDrill ahead.", "tightWell": "0", "tvd": null, "tvdCsgLast": "1334", "tvdStrengthForm": "0", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-13T09:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1368", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "6.5" }, { "dTim": "2013-04-13T15:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1400", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8" }, { "dTim": "2013-04-13T21:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "1346", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8.5" }, { "dTim": "2013-04-13T02:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "1346", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9.5" }, { "dTim": "2013-04-13T16:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1400", "mudClass": "oil based", "presBopRating": "345", "pv": "32", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "10" } ]
[ { "dTim": "2013-04-14T00:00:00+02:00", "equivalentMudWeight": "1.03", "md": "1400", "readingKind": "estimated" } ]
[]
[ { "comments": "Drilled firm cement from 1365 m to 1368 m with 3700 l/min, 190 bar, 60-90 RPM, 5-20 kNm, WOB 3-10 Ton.\nCleaned out rathole 3 times.", "dTimEnd": "2013-04-13T02:00:00+02:00", "dTimStart": "2013-04-13T00:00:00+02:00", "md": "1365", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled new formation from 1365 m to 1368 m with 3700 l/min, 188 bar, 90 RPM, 2-8 kNm, WOB 5-10 Ton.", "dTimEnd": "2013-04-13T02:30:00+02:00", "dTimStart": "2013-04-13T02:00:00+02:00", "md": "1368", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pulled bit inside shoe.\nCirculated until even MW in out 1,40 sg with 3700 liter/min, 180 bar, 20 rpm, 5 kNm.", "dTimEnd": "2013-04-13T04:00:00+02:00", "dTimStart": "2013-04-13T02:30:00+02:00", "md": "1368", "phase": "fixed", "proprietaryCode": "drilling -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed pre-job meeting prior to FIT.\nConfirmed line up down string through TDS.\nAttempted to pressure test surface lines against upper / lower IBOP. No test obtained.\nDisconnected TDS and installed pump in sub.\nAttempted to pressure test surface lines against pump in sub. No test obtained.\n\n\n \n\n", "dTimEnd": "2013-04-13T07:30:00+02:00", "dTimStart": "2013-04-13T04:00:00+02:00", "md": "1368", "phase": "fixed", "proprietaryCode": "formation evaluation -- rft/fit", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Performed internal test of cement unit. Not able to obtain good test.\nInvestigated problems on unit.\nBy-passed shutt-off valve.\nObatined good pressure test on cement unit.\n\nMeanwhile:\nCirculated and pumped with 3500 liter/min, 173 bar, 60 rpm, 7-9 kNm.\nPerformed pre-job meeting prior to FIT.", "dTimEnd": "2013-04-13T12:00:00+02:00", "dTimStart": "2013-04-13T07:30:00+02:00", "md": "1368", "phase": "fixed", "proprietaryCode": "formation evaluation -- rft/fit", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Lined up to pump down string through TDS\nPressure tested lines to 30 / 200 bar - 5 /10 minutes.\nSpaced out and closed upper pipe ram.\nPerformed FIT to 1,55 sg EMW using 1,40 sg mud. \nPumped 320 liter from 5 bar to 20 bar at cement unit with 40 liter/min. \nBled back 320 liter.", "dTimEnd": "2013-04-13T12:30:00+02:00", "dTimStart": "2013-04-13T12:00:00+02:00", "md": "1368", "phase": "fixed", "proprietaryCode": "formation evaluation -- rft/fit", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Washed and reamed rathole with 4420 l/min, 256 bar, 60 RPM, 5-6 kNm", "dTimEnd": "2013-04-13T13:30:00+02:00", "dTimStart": "2013-04-13T12:30:00+02:00", "md": "1368", "phase": "fixed", "proprietaryCode": "drilling -- ream", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 17 1/2\" hole from 1368 m to 1400 m with 3675-4455 l/min, 188-257 bar, 60-140 RPM, 7-15 kNm, WOB 5 Ton, ECD 1,446-1,449 sg.\n5 ea. cuttings screw conveyors plugged up.", "dTimEnd": "2013-04-13T15:00:00+02:00", "dTimStart": "2013-04-13T13:30:00+02:00", "md": "1400", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Worked with unplugging cuttings screw conveyors.\n\nMeanwhile:\nMonitored well on trip tank and worked string from 1324 m to 1360 m.", "dTimEnd": "2013-04-14T00:00:00+02:00", "dTimStart": "2013-04-13T15:00:00+02:00", "md": "1400", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" } ]
[ { "dTim": "2013-04-14T00:00:00+02:00", "lithology": "Claystone", "mdBottom": "1390", "mdTop": "1365", "show": null, "tvdBottom": "1363", "tvdTop": "1340" }, { "dTim": "2013-04-14T00:00:00+02:00", "lithology": "Claystone", "mdBottom": "1400", "mdTop": "1390", "show": null, "tvdBottom": "1371", "tvdTop": "1363" } ]
15_9_F_11_T2_2013_04_15
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-14T00:00:00+02:00
2013-04-15T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "19.9", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-15T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "100", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill 17 1/2\" to TD.", "hpht": "0", "md": "1500", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "40", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "Drilled 17 1/2\" hole from 1400 m to 1500 m. Waited on weather.", "tightWell": "0", "tvd": null, "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-14T21:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1500", "mudClass": "oil based", "presBopRating": "345", "pv": "37", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-14T12:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1500", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8.5" }, { "dTim": "2013-04-14T02:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1500", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8" } ]
[ { "dTim": "2013-04-15T00:00:00+02:00", "equivalentMudWeight": "1.03", "md": "1500", "readingKind": "estimated" } ]
[ { "azi": "277.93", "dTim": "2013-04-15T00:00:00+02:00", "incl": "23.67", "md": "1385.2", "tvd": "1358.6" }, { "azi": "267.61", "dTim": "2013-04-15T00:00:00+02:00", "incl": "26.97", "md": "1427.2", "tvd": "1396.6" }, { "azi": "259.66", "dTim": "2013-04-15T00:00:00+02:00", "incl": "29.83", "md": "1467.5", "tvd": "1432.1" }, { "azi": "259.61", "dTim": "2013-04-15T00:00:00+02:00", "incl": "30.96", "md": "1486.2", "tvd": "1448.2" } ]
[ { "comments": "Worked with unplugging cuttings screw conveyors.\nEstablished circulation with 4500 liter/min, 280 bar.\nShakers and cuttings screw conveyors handled returns as required.\n\nMeanwhile:\nMonitored well on trip tank and worked string from 1324 m to 1360 m.\nUp / down weights 130 / 115 Ton.", "dTimEnd": "2013-04-14T02:00:00+02:00", "dTimStart": "2013-04-14T00:00:00+02:00", "md": "1400", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Washed down from 1360 m to 1400 m with 4400 liter/min, 274 bar, 60 rpm, 8 kNm.\nPerformed survey.\nRupture disk tripped on MP #1 and MP #2.\nReplaced rupture discs.", "dTimEnd": "2013-04-14T05:30:00+02:00", "dTimStart": "2013-04-14T02:00:00+02:00", "md": "1400", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "mud loss" }, { "comments": "Drilled 17 1/2\" hole from 1400 m to 1500 m with 3990-4300 l/min, 165-246 bar, 100-140 RPM, 7-11 kNm, WOB 1-3 Ton, ECD 1,434-1,448 sg.", "dTimEnd": "2013-04-14T16:00:00+02:00", "dTimStart": "2013-04-14T05:30:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather.\nNot able to back load cuttings from ISO tanks to supply vessel due to heavy wind and sea.\n\nMeanwhile:\nCirculated hole clean at 1500 meter with 4300 liter/min, 248 bar.\nPulled back into shoe.\nCirculated with 1440 liter/min, 35 bar.\nPicked up and racked back 5 1/2\" DP.\n", "dTimEnd": "2013-04-15T00:00:00+02:00", "dTimStart": "2013-04-14T16:00:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" } ]
[ { "dTim": "2013-04-15T00:00:00+02:00", "lithology": "Claystone", "mdBottom": "1440", "mdTop": "1400", "show": null, "tvdBottom": "1408", "tvdTop": "1372" }, { "dTim": "2013-04-15T00:00:00+02:00", "lithology": "Claystone", "mdBottom": "1470", "mdTop": "1440", "show": null, "tvdBottom": "1434", "tvdTop": "1408" }, { "dTim": "2013-04-15T00:00:00+02:00", "lithology": "Claystone", "mdBottom": "1500", "mdTop": "1470", "show": null, "tvdBottom": "1460", "tvdTop": "1434" } ]
15_9_F_11_T2_2013_04_16
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-15T00:00:00+02:00
2013-04-16T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20.1", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-16T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "0", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill 17 1/2\" hole to TD.", "hpht": "0", "md": "1500", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "41", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "Waited om weather.\nBack loaded cuttings to vessel. ", "tightWell": "0", "tvd": "1460", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-15T21:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "1500", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9.5" }, { "dTim": "2013-04-15T15:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1500", "mudClass": "oil based", "presBopRating": "345", "pv": "32", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "10" }, { "dTim": "2013-04-15T12:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1500", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8.5" }, { "dTim": "2013-04-15T03:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1500", "mudClass": "oil based", "presBopRating": "345", "pv": "35", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-15T23:30:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1779", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" } ]
[ { "dTim": "2013-04-16T00:00:00+02:00", "equivalentMudWeight": "1.03", "md": "1500", "readingKind": "estimated" } ]
[]
[ { "comments": "Waited on weather.\nNot able to back load cuttings from ISO tanks to supply vessel due to heavy wind and sea.\n\nMeanwhile:\nCirculated with 1440 liter/min, 35 bar.\nPicked up and racked back 5 1/2\" DP, 23 stands racked back.", "dTimEnd": "2013-04-15T16:00:00+02:00", "dTimStart": "2013-04-15T00:00:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Back loaded cuttings from ISO tanks to supply vessel, Total 40 Ton.", "dTimEnd": "2013-04-15T23:00:00+02:00", "dTimStart": "2013-04-15T16:00:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH with 17 1/2\" BHA on 5 1/2\" DP from 1333 m to 1482 m. Average tripping speed 298 m/hr.\n\nContinue to back load cuttings from ISO tanks to supply vessel.", "dTimEnd": "2013-04-15T23:30:00+02:00", "dTimStart": "2013-04-15T23:00:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Washed and reamed down from 1482 m to 1493 m with 3200 liter/min, 168 bar, 30 rpm, 9 kNm.\nLost all rig power supply on the rig due to work on faulty gas detector.", "dTimEnd": "2013-04-16T00:00:00+02:00", "dTimStart": "2013-04-15T23:30:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_17
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-16T00:00:00+02:00
2013-04-17T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20.3", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-17T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "280", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill 17 1/2\" to TD.", "hpht": "0", "md": "1780", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "42", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "Drilled 17 1/2\" hole from 1500 m to 1780 m.\n", "tightWell": "0", "tvd": "1694", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-16T09:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1620", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8.5" }, { "dTim": "2013-04-16T15:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1735", "mudClass": "oil based", "presBopRating": "345", "pv": "35", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" } ]
[ { "dTim": "2013-04-17T00:00:00+02:00", "equivalentMudWeight": "1.03", "md": "1780", "readingKind": "estimated" } ]
[ { "azi": "258.89", "dTim": "2013-04-17T00:00:00+02:00", "incl": "32.18", "md": "1507.5", "tvd": "1466.3" }, { "azi": "259.4", "dTim": "2013-04-17T00:00:00+02:00", "incl": "34.04", "md": "1548.1", "tvd": "1500.4" }, { "azi": "258.58", "dTim": "2013-04-17T00:00:00+02:00", "incl": "33.98", "md": "1588.6", "tvd": "1533.9" }, { "azi": "258.19", "dTim": "2013-04-17T00:00:00+02:00", "incl": "34.39", "md": "1628.6", "tvd": "1567" }, { "azi": "257.63", "dTim": "2013-04-17T00:00:00+02:00", "incl": "34.35", "md": "1668.7", "tvd": "1600.1" }, { "azi": "257.6", "dTim": "2013-04-17T00:00:00+02:00", "incl": "34.43", "md": "1709.3", "tvd": "1633.6" }, { "azi": "258.66", "dTim": "2013-04-17T00:00:00+02:00", "incl": "31.41", "md": "1750", "tvd": "1667.8" }, { "azi": "259.27", "dTim": "2013-04-17T00:00:00+02:00", "incl": "30.2", "md": "1764", "tvd": "1679.8" } ]
[ { "comments": "Restarted all rig systems.\n\nMeanwhile:\nLined up and observed well on trip tank.\nRotated string periodically to ensure free movement.\n", "dTimEnd": "2013-04-16T01:00:00+02:00", "dTimStart": "2013-04-16T00:00:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Restarted all rig systems.\n\nMeanwhile:\nEstablished circulation with 440 liter/min, 7 bar.\nReciprocated pipe.", "dTimEnd": "2013-04-16T02:00:00+02:00", "dTimStart": "2013-04-16T01:00:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "interruption -- other", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Continue to back load cuttings from ISO tanks to supply vessel.\n", "dTimEnd": "2013-04-16T02:30:00+02:00", "dTimStart": "2013-04-16T02:00:00+02:00", "md": "1500", "phase": "fixed", "proprietaryCode": "drilling -- ream", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 17 1/2\" hole from 1500 m to 1573 m with 4275-4320 l/min, 257-265 bar, 120-140 RPM, 9-11 kNm, WOB 5-8 Ton, ECD 1,441-1,449 sg. Average ROP 16,2 meter/hour.\nDrilled with reduced drilling rate due to surface cuttings transfer system restriction.", "dTimEnd": "2013-04-16T07:00:00+02:00", "dTimStart": "2013-04-16T02:30:00+02:00", "md": "1573", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 17 1/2\" hole from 1573 m to 1685 m with 4320 l/min, 254-260 bar, 140 RPM, 10-15 kNm, WOB 5-6 Ton, ECD 1,431-1,442 sg, max gas 0,57 %. Average ROP 22,5 meter/hour.\nDrilled with reduced drilling rate due to surface cuttings transfer system restrictions.", "dTimEnd": "2013-04-16T12:00:00+02:00", "dTimStart": "2013-04-16T07:00:00+02:00", "md": "1685", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled 17 1/2\" hole from 1685 m to 1780 m with 4320 l/min, 256-262 bar, 140 RPM, 12-15 kNm, WOB 5-6 Ton, ECD 1,438-1,443 sg, max gas 0,46 %. Average ROP 15,8 meter/hour.\nDrilled with reduced drilling rate due to surface cuttings transfer system restrictions. \nStopped drilling due to full ISO tanks.\nNot able to back load cuttings from ISO tanks to supply vessel due to heavy wind and sea.", "dTimEnd": "2013-04-16T18:00:00+02:00", "dTimStart": "2013-04-16T12:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Circulated hole clean 4300 liter/min, 254 bar, 120 rpm, 7 kNm.", "dTimEnd": "2013-04-16T21:00:00+02:00", "dTimStart": "2013-04-16T18:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "drilling -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with 17 1/2 BHA on 5 1/2\" DP from 1765 m to 1346 m. Average tripping speed 838 m/hr.", "dTimEnd": "2013-04-16T22:00:00+02:00", "dTimStart": "2013-04-16T21:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather.\nNot able to back load cuttings from ISO tanks to supply vessel due to heavy wind and sea.\n\nMeanwhile:\nCirculated with 1420 liter/min, 65 bar.", "dTimEnd": "2013-04-17T00:00:00+02:00", "dTimStart": "2013-04-16T22:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" } ]
[ { "dTim": "2013-04-17T00:00:00+02:00", "lithology": "Claystone", "mdBottom": "1570", "mdTop": "1500", "show": null, "tvdBottom": "1519", "tvdTop": "1460" }, { "dTim": "2013-04-17T00:00:00+02:00", "lithology": "Claystone", "mdBottom": "1650", "mdTop": "1570", "show": null, "tvdBottom": "1585", "tvdTop": "1519" }, { "dTim": "2013-04-17T00:00:00+02:00", "lithology": "Claystone with minor limestone stringers", "mdBottom": "1780", "mdTop": "1650", "show": null, "tvdBottom": "1693", "tvdTop": "1585" } ]
15_9_F_11_T2_2013_04_18
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-17T00:00:00+02:00
2013-04-18T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20.5", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-18T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "32", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "None", "hpht": "0", "md": "1812", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "43", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "None", "tightWell": "0", "tvd": "1721.5", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-17T16:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1779", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-17T20:30:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1779", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "10" }, { "dTim": "2013-04-17T12:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1779", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-17T01:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1822", "mudClass": "oil based", "presBopRating": "345", "pv": "35", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "10" } ]
[ { "dTim": "2013-04-18T00:00:00+02:00", "equivalentMudWeight": "1.03", "md": "1812", "readingKind": "estimated" } ]
[ { "azi": "260.32", "dTim": "2013-04-18T00:00:00+02:00", "incl": "28.25", "md": "1790.3", "tvd": "1702.8" } ]
[ { "comments": "Waited on weather.\nNot able to back load cuttings from ISO tanks to supply vessel due to heavy wind and sea.\n\nMeanwhile:\nCirculated with 1420 liter/min, 65 bar.", "dTimEnd": "2013-04-17T06:00:00+02:00", "dTimStart": "2013-04-17T00:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather.\n\nMeanwhile service TDS and PRS`s. Change valves on MP # 3", "dTimEnd": "2013-04-17T15:00:00+02:00", "dTimStart": "2013-04-17T06:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Backload cuttings to boat.\n\nMeanwhile circ with 1410lpm", "dTimEnd": "2013-04-17T16:00:00+02:00", "dTimStart": "2013-04-17T15:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Unable to start screw conveyor. Continue circ.", "dTimEnd": "2013-04-17T17:30:00+02:00", "dTimStart": "2013-04-17T16:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Test run augers. \n\nMeanwhile circ with 1420lpm", "dTimEnd": "2013-04-17T20:30:00+02:00", "dTimStart": "2013-04-17T17:30:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "TBT. RIH from 1345-1765m.", "dTimEnd": "2013-04-17T22:00:00+02:00", "dTimStart": "2013-04-17T20:30:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Wash in from 1765-1780m with 3300lpm, 30 RPM, 7Nm TRQ. Take SCR at 1780m.", "dTimEnd": "2013-04-17T22:30:00+02:00", "dTimStart": "2013-04-17T22:00:00+02:00", "md": "1780", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled from 1780-1812m", "dTimEnd": "2013-04-18T00:00:00+02:00", "dTimStart": "2013-04-17T22:30:00+02:00", "md": "1812", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" } ]
[ { "dTim": "2013-04-18T00:00:00+02:00", "lithology": "Claystone with Limestone stringers", "mdBottom": "1812", "mdTop": "1780", "show": null, "tvdBottom": "1722", "tvdTop": "1693" } ]
15_9_F_11_T2_2013_04_19
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-18T00:00:00+02:00
2013-04-19T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20.7", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-19T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "154", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill 17 1/2\" hole to TD.", "hpht": "0", "md": "1966", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "44", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "Drilled and orientated 17 1/2\" hole from 1812 m to 1966 m.\nWOW:\nUnable to backload cuttings due to high wind and sea.\nCirculated hole clean and POOH to 1320 m inside 20\" shoe at 1358 m.\nBack loaded 35 m3 from ISO pump system to supply vessel.\nStood off supply vessel and WOW", "tightWell": "0", "tvd": "1866", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-18T09:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1822", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9.5" }, { "dTim": "2013-04-18T21:30:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1966", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "10.5" }, { "dTim": "2013-04-18T12:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1966", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" } ]
[ { "dTim": "2013-04-19T00:00:00+02:00", "equivalentMudWeight": "1.03", "md": "1966", "readingKind": "estimated" } ]
[ { "azi": "261.22", "dTim": "2013-04-19T00:00:00+02:00", "incl": "25.02", "md": "1830.4", "tvd": "1738.6" }, { "azi": "260.33", "dTim": "2013-04-19T00:00:00+02:00", "incl": "21.55", "md": "1870.6", "tvd": "1775.5" }, { "azi": "261.1", "dTim": "2013-04-19T00:00:00+02:00", "incl": "18.65", "md": "1910.9", "tvd": "1813.4" }, { "azi": "264.1", "dTim": "2013-04-19T00:00:00+02:00", "incl": "15.46", "md": "1950.9", "tvd": "1851.6" } ]
[ { "comments": "Drilled and orientated 17 1/2\" hole from 1812 m to 1944 m with 4300 lpm, 270 bar, ECD 1.44 sg, WOB 5-7 MT, 140 rpm, 13-15 kNm, Inst. ROP 40 m/hr, Average ROP 26 m/hr.", "dTimEnd": "2013-04-18T05:00:00+02:00", "dTimStart": "2013-04-18T00:00:00+02:00", "md": "1944", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and orientated 17 1/2\" hole from 1944 m to 1963 m at reduced ROP due to cuttings handling system with 4000 lpm, 240 bar, ECD 1.44 sg, WOB 4 MT, 140 rpm, 12-13 kNm, Inst. ROP 30 m/hr, Average ROP 19 m/hr.\n\nLast survey: 1950.9m MD, 15.46 incl, 264.1 azimuth", "dTimEnd": "2013-04-18T06:00:00+02:00", "dTimStart": "2013-04-18T05:00:00+02:00", "md": "1963", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and orientated 17 1/2\" hole from 1963 m to 1966 m with 4000 lpm, 240 bar, ECD 1.44 sg, WOB 4 MT, 140 rpm, 12-13 kNm, Inst. ROP 30 m/hr. \nUnable to back load cuttings from ISO pumps to supply vessel due to high wind and sea state. \nCommenced circulating hole clean.\n", "dTimEnd": "2013-04-18T06:30:00+02:00", "dTimStart": "2013-04-18T06:00:00+02:00", "md": "1966", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather to back load cuttings.\nCirculated hole clean while reciprocating and rotating string with 4300 lpm, 267 bar, 120 rpm, 9 kNm, ECD 1.43 sg.", "dTimEnd": "2013-04-18T08:00:00+02:00", "dTimStart": "2013-04-18T06:30:00+02:00", "md": "1966", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather to back load cuttings.\nRacked back 5 1/2\" DP stand. Circulated hole clean while reciprocating and rotating string with 4300 lpm, 267 bar, 120 rpm, 9 kNm, ECD 1.42 sg.", "dTimEnd": "2013-04-18T10:00:00+02:00", "dTimStart": "2013-04-18T08:00:00+02:00", "md": "1898", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather to back load cuttings.\nHeld TBT and flowchecked well for 15 min - well static.", "dTimEnd": "2013-04-18T10:30:00+02:00", "dTimStart": "2013-04-18T10:00:00+02:00", "md": "1898", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather to back load cuttings.\nPOOH with 5 1/2\" DP wet from 1898 m to 1320 m inside 20\" shoe.", "dTimEnd": "2013-04-18T12:00:00+02:00", "dTimStart": "2013-04-18T10:30:00+02:00", "md": "1320", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather to back load cuttings.\nFlow checked well for 15 min - well static", "dTimEnd": "2013-04-18T12:30:00+02:00", "dTimStart": "2013-04-18T12:00:00+02:00", "md": "1320", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather to back load cuttings.\n\nMeanwhile:\nCirculated with 1400 lpm, 30 bar, 0 rpm.", "dTimEnd": "2013-04-18T20:00:00+02:00", "dTimStart": "2013-04-18T12:30:00+02:00", "md": "1318", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Called in supply vessel and hook up ISO pumps overboard hose. \n\nMeanwhile:\nCirculated with 1400 lpm, 30 bar, 0 rpm. \nFunction tested BOP", "dTimEnd": "2013-04-18T21:00:00+02:00", "dTimStart": "2013-04-18T20:00:00+02:00", "md": "1318", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Back loaded cuttings from ISO pump # 1 to supply vessel.\n\nMeanwhile:\nPulled back 10 m and circulated with 1400 lpm, 30 bar, 0 rpm.", "dTimEnd": "2013-04-18T22:00:00+02:00", "dTimStart": "2013-04-18T21:00:00+02:00", "md": "1308", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Back loaded cuttings from ISO pump # 2 to supply vessel. Cuttings transfer line plugged-up after 15 m3 pumped. Cleared lines and stood off supply vessel due to heavy wind and sea.\n\nMeanwhile:\nCirculated with 1400 lpm, 30 bar, 0 rpm. \nHeld PDSA meeting with all available personale", "dTimEnd": "2013-04-18T23:00:00+02:00", "dTimStart": "2013-04-18T22:00:00+02:00", "md": "1308", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Waited on weather to back load cuttings.\n\nMeanwhile:\nCirculated with 1420 lpm, 33 bar, 0 rpm. \nHeld PDSA meeting with all available personale", "dTimEnd": "2013-04-19T00:00:00+02:00", "dTimStart": "2013-04-18T23:00:00+02:00", "md": "1308", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" } ]
[ { "dTim": "2013-04-19T00:00:00+02:00", "lithology": "Claystone with Limestone stringers", "mdBottom": "1860", "mdTop": "1812", "show": null, "tvdBottom": "1766", "tvdTop": "1722" }, { "dTim": "2013-04-19T00:00:00+02:00", "lithology": "Claystone with Limestone stringers and rare Sandstone", "mdBottom": "1966", "mdTop": "1860", "show": null, "tvdBottom": "1866", "tvdTop": "1766" } ]
15_9_F_11_T2_2013_04_20
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-19T00:00:00+02:00
2013-04-20T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20.9", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-20T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "80", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill 17 1/2\" hole to section TD at 2567 m", "hpht": "0", "md": "2046", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "45", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "Waited on weather to transfer cuttings to supply vessel\nContinuously tranfered cuttings to supply vessel.\nRIH on 5 1/2\" DP and drilled 17 1/2\" hole to 2046 m", "tightWell": "0", "tvd": "1945", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-19T22:20:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2006", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-19T15:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "1966", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-19T01:30:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2086", "mudClass": "oil based", "presBopRating": "345", "pv": "30", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9.5" }, { "dTim": "2013-04-19T20:40:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2409", "mudClass": "oil based", "presBopRating": "345", "pv": "32", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8.5" } ]
[ { "dTim": "2013-04-20T00:00:00+02:00", "equivalentMudWeight": "1.03", "md": "2046", "readingKind": "estimated" } ]
[ { "azi": "266.24", "dTim": "2013-04-20T00:00:00+02:00", "incl": "11.66", "md": "1992.1", "tvd": "1891.6" }, { "azi": "271.93", "dTim": "2013-04-20T00:00:00+02:00", "incl": "8.11", "md": "2032.4", "tvd": "1931.3" } ]
[ { "comments": "Waited on weather to back load cuttings.\n\nMeanwhile:\nCirculated with 1420 lpm, 33 bar, 0 rpm.", "dTimEnd": "2013-04-19T15:30:00+02:00", "dTimStart": "2013-04-19T00:00:00+02:00", "md": "1308", "phase": "fixed", "proprietaryCode": "interruption -- waiting on weather", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Called in supply vessel and back loaded cuttings from ISO pumps.", "dTimEnd": "2013-04-19T17:00:00+02:00", "dTimStart": "2013-04-19T15:30:00+02:00", "md": "1308", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. RIH on 5 1/2\" DP from 1308 m to 1950 m.\n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-19T19:00:00+02:00", "dTimStart": "2013-04-19T17:00:00+02:00", "md": "1950", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Washed down from 1950 m to 1965 m with 3300 lpm, 183 bar, 40 rpm, 8 kNm. \nRecorded SCRs at 1965 m.\n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-19T19:30:00+02:00", "dTimStart": "2013-04-19T19:00:00+02:00", "md": "1365", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Established drilling parameters. Drilled and orientated 17 1/2\" hole from 1966 m to 1984 m at reduced ROP to establish rig solids control system running with cuttings prior to swiching to ISO pump system. \nDrilling parameters: 4300 lpm, 275 bar, 120 rpm, 10-12 kNm, WOB 5-6 MT, Inst ROP 15 m/hr, ECD 1.44 SG. \n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-19T21:30:00+02:00", "dTimStart": "2013-04-19T19:30:00+02:00", "md": "1984", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and orientated 17 1/2\" hole from 1984 m to 2046 m with 4300 lpm, 275 bar, 140 rpm, 12-15 kNm, WOB 8-10 MT, Inst ROP 35 m/hr, ECD 1.44 SG. \n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-20T00:00:00+02:00", "dTimStart": "2013-04-19T21:30:00+02:00", "md": "2046", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" } ]
[ { "dTim": "2013-04-20T00:00:00+02:00", "lithology": "Claystone with minor Limestone/Dolomite stringers", "mdBottom": "2020", "mdTop": "1966", "show": null, "tvdBottom": "1919.1", "tvdTop": "1866.2" }, { "dTim": "2013-04-20T00:00:00+02:00", "lithology": "Claystone with minor Limestone/Dolomite stringers", "mdBottom": "2046", "mdTop": "2020", "show": null, "tvdBottom": "1944.8", "tvdTop": "1919.1" } ]
15_9_F_11_T2_2013_04_21
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-20T00:00:00+02:00
2013-04-21T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "21.1", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-21T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "429", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Drill 17 1/2\" hole to TD and circulate hole clean. \nPOOH and L/O 17 1/2\" BHA.\nRetrieve wear bushing and R/U csg. running equioment.", "hpht": "0", "md": "2475", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "46", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "Drilled and orientated 17 1/2\" hole from 2046 m to 2475 m.", "tightWell": "0", "tvd": "2360", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-20T15:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2323", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-20T09:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2280", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "8.5" }, { "dTim": "2013-04-20T02:00:00+02:00", "density": "1.4", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2520", "mudClass": "oil based", "presBopRating": "345", "pv": "29", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "7" } ]
[ { "dTim": "2013-04-21T00:00:00+02:00", "equivalentMudWeight": "1.03", "md": "2475", "readingKind": "estimated" } ]
[ { "azi": "297.12", "dTim": "2013-04-21T00:00:00+02:00", "incl": "4.24", "md": "2095.2", "tvd": "1993.8" }, { "azi": "311.26", "dTim": "2013-04-21T00:00:00+02:00", "incl": "3.09", "md": "2112.8", "tvd": "2011.3" }, { "azi": "285.2", "dTim": "2013-04-21T00:00:00+02:00", "incl": "5.75", "md": "2072.5", "tvd": "1971.1" }, { "azi": "335", "dTim": "2013-04-21T00:00:00+02:00", "incl": "2.75", "md": "2134.7", "tvd": "2033.2" }, { "azi": "356.57", "dTim": "2013-04-21T00:00:00+02:00", "incl": "3.55", "md": "2152.9", "tvd": "2051.4" }, { "azi": "33.34", "dTim": "2013-04-21T00:00:00+02:00", "incl": "5.67", "md": "2193.1", "tvd": "2091.4" }, { "azi": "52.64", "dTim": "2013-04-21T00:00:00+02:00", "incl": "8.75", "md": "2234", "tvd": "2132" }, { "azi": "62.25", "dTim": "2013-04-21T00:00:00+02:00", "incl": "12.46", "md": "2274.3", "tvd": "2171.6" }, { "azi": "65.66", "dTim": "2013-04-21T00:00:00+02:00", "incl": "15.1", "md": "2314.3", "tvd": "2210.5" }, { "azi": "66.51", "dTim": "2013-04-21T00:00:00+02:00", "incl": "18.24", "md": "2355.2", "tvd": "2249.6" }, { "azi": "68.45", "dTim": "2013-04-21T00:00:00+02:00", "incl": "21.66", "md": "2395.5", "tvd": "2287.5" }, { "azi": "68.01", "dTim": "2013-04-21T00:00:00+02:00", "incl": "25.01", "md": "2435.6", "tvd": "2324.3" }, { "azi": "66.94", "dTim": "2013-04-21T00:00:00+02:00", "incl": "28.81", "md": "2475.9", "tvd": "2360.3" } ]
[ { "comments": "Drilled and orientated 17 1/2\" hole from 2046 m to 2113 m with 4300 lpm, 285 bar, 140 rpm, 13-15 kNm, WOB 9-11 MT, Inst ROP 35 m/hr, ECD 1.44 SG. \n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-20T03:00:00+02:00", "dTimStart": "2013-04-20T00:00:00+02:00", "md": "2113", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and orientated 17 1/2\" hole from 2113 m to 2178 m with 4230 lpm, 283 bar, 140 rpm, 12-16 kNm, WOB 8-10 MT, Inst ROP 35 m/hr, ECD 1.43 SG. \n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-20T06:00:00+02:00", "dTimStart": "2013-04-20T03:00:00+02:00", "md": "2178", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and orientated 17 1/2\" hole from 2178 m to 2290 m with 4252 lpm, 282 bar, 140 rpm, 16-19 kNm, WOB 12-16 MT, Inst ROP 35 m/hr, ECD 1.43 SG. \n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-20T11:30:00+02:00", "dTimStart": "2013-04-20T06:00:00+02:00", "md": "2290", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and orientated 17 1/2\" hole from 2290 m to 2330 m with 4230 lpm, 282 bar, 140 rpm, 16-19 kNm, WOB 9-11 MT, Inst ROP 10 m/hr, ECD 1.42 SG. \n\nMeanwhile:\nBack loaded cuttings to supply vessel\nFlushed U-tube with fresh mud", "dTimEnd": "2013-04-20T16:00:00+02:00", "dTimStart": "2013-04-20T11:30:00+02:00", "md": "2330", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and orientated 17 1/2\" hole from 2330 m to 2378 m with 4250 lpm, 283 bar, 140 rpm, 15-17 kNm, WOB 9-12 MT, Inst ROP 25 m/hr, ECD 1.43 SG. \nIdentified Balder formation at 2373 m.\n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-20T19:00:00+02:00", "dTimStart": "2013-04-20T16:00:00+02:00", "md": "2378", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled and orientated 17 1/2\" hole from 2378 m to 2475 m with 4300 lpm, 287 bar, 140 rpm, 20-25 kNm, WOB 18-20 MT, Inst ROP 25 m/hr, ECD 1.43 SG. \n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-21T00:00:00+02:00", "dTimStart": "2013-04-20T19:00:00+02:00", "md": "2475", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" } ]
[ { "dTim": "2013-04-21T00:00:00+02:00", "lithology": "Claystone with Limestone/Dolomite stringers", "mdBottom": "2221", "mdTop": "2046", "show": null, "tvdBottom": "2119.1", "tvdTop": "1844.8" }, { "dTim": "2013-04-21T00:00:00+02:00", "lithology": "Very fine to medium Sandstone", "mdBottom": "2290", "mdTop": "2221", "show": null, "tvdBottom": "2186.9", "tvdTop": "2119.1" }, { "dTim": "2013-04-21T00:00:00+02:00", "lithology": "Claystone with Limestone/Dolomite stringers", "mdBottom": "2310", "mdTop": "2290", "show": null, "tvdBottom": "2206.3", "tvdTop": "2186.9" }, { "dTim": "2013-04-21T00:00:00+02:00", "lithology": "Vari-coloured Claystone with Limestone/Dolomite stringers ", "mdBottom": "2373", "mdTop": "2310", "show": null, "tvdBottom": "2273.2", "tvdTop": "2206.3" }, { "dTim": "2013-04-21T00:00:00+02:00", "lithology": "Claystone with Tuff and Limestone/Dolomite stringers", "mdBottom": "2435", "mdTop": "2373", "show": null, "tvdBottom": "2323.8", "tvdTop": "2273.2" }, { "dTim": "2013-04-21T00:00:00+02:00", "lithology": "Claystone with Trace Lmestone/Dolomite", "mdBottom": "2475", "mdTop": "2435", "show": null, "tvdBottom": "2359.5", "tvdTop": "2323.8" } ]
15_9_F_11_T2_2013_04_22
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-21T00:00:00+02:00
2013-04-22T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "20.3", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-22T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "100", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH retrieve seat protector. R/U casing equipment and RIH 14\" casing.", "hpht": "0", "md": "2574", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "47", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "Drilled 17 1/2\" hole to section TD at 2574 m. POOH and L/O 17 1/2\" steerable BHA.", "tightWell": "0", "tvd": "2442", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-21T22:00:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-21T12:00:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-21T03:30:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" } ]
[]
[ { "azi": "67.2", "dTim": "2013-04-22T00:00:00+02:00", "incl": "31.89", "md": "2516.2", "tvd": "2395.1" }, { "azi": "68.22", "dTim": "2013-04-22T00:00:00+02:00", "incl": "36", "md": "2556.4", "tvd": "2428.4" }, { "azi": "68.07", "dTim": "2013-04-22T00:00:00+02:00", "incl": "36.31", "md": "2559.5", "tvd": "2430.9" } ]
[ { "comments": "Drilled and orientated 17 1/2\" hole from 2475 m to 2540 m with 4300 lpm, 292 bar, 140 rpm, 20-25 kNm, WOB 18-20 MT, Inst ROP 35 m/hr, ECD 1.44 SG. \nIdentified Lista formation at 2512 m\n\nMeanwhile:\nBack loaded cuttings to supply vessel", "dTimEnd": "2013-04-21T03:00:00+02:00", "dTimStart": "2013-04-21T00:00:00+02:00", "md": "2540", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled hole clean from 2540 m to 2570 with 4250 lpm, 290 bar, 140 rpm, 15-20 kNm, WOB 7-10 MT, Inst ROP 10 m/hr, ECD 1.43 SG.", "dTimEnd": "2013-04-21T06:00:00+02:00", "dTimStart": "2013-04-21T03:00:00+02:00", "md": "2570", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Drilled hole clean from 2570 to 17 1/2\" section TD at 2574 m with 4250 lpm, 290 bar, 140 rpm, 15-20 kNm, WOB 7-10 MT, Inst ROP 10 m/hr, ECD 1.43 SG. \nFinal TD called at 07:20 hrs.", "dTimEnd": "2013-04-21T07:30:00+02:00", "dTimStart": "2013-04-21T06:00:00+02:00", "md": "2574", "phase": "fixed", "proprietaryCode": "drilling -- drill", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Circulated hole clean with 4286 lpm, 289 bar, 140 rpm, 11-15 kNm, ECD 1.42 SG. Circulated total 3 B/U racking one 5 1/2\" DP stand on every B/U while increasing mud weigth 2 points to 1.42 sg.\n\nMeanwhile:\nBack loaded cuttings to supply vessel and stood off same. 4 empty ISO pumps onboard.", "dTimEnd": "2013-04-21T12:00:00+02:00", "dTimStart": "2013-04-21T07:30:00+02:00", "md": "2464", "phase": "fixed", "proprietaryCode": "drilling -- circulating conditioning", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Flow checked well for 15 min - well static. POOH 17 1/2\" BHA on 5 1/2\" DP 10 stands wet from 2464 m to 1354 m.", "dTimEnd": "2013-04-21T14:00:00+02:00", "dTimStart": "2013-04-21T12:00:00+02:00", "md": "2169", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pumped slug and POOH 17 1/2\" BHA on 5 1/2\" DP from 2169 m to 1354 m.\nNo overpull observed.", "dTimEnd": "2013-04-21T16:30:00+02:00", "dTimStart": "2013-04-21T14:00:00+02:00", "md": "1354", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH 17 1/2\" BHA on 5 1/2\" DP/HWDP from 1354 m to 272 m. Flow checked for 15 min - Well Static.", "dTimEnd": "2013-04-21T18:30:00+02:00", "dTimStart": "2013-04-21T16:30:00+02:00", "md": "272", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. POOH 17 1/2\" BHA from 272 m to surface. Racked back 2 x 8 1/4\" DC stands and layed out remaining 17 1/2\" BHA.\nBit grading: 1.3.WT.G.X.I.BT.TD", "dTimEnd": "2013-04-21T22:30:00+02:00", "dTimStart": "2013-04-21T18:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- trip", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Cleaned and cleared drill floor. Isolated drilling equipment, inspected and serviced same", "dTimEnd": "2013-04-22T00:00:00+02:00", "dTimStart": "2013-04-21T22:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_23
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-22T00:00:00+02:00
2013-04-23T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "18.9", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-23T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "0", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "RIH 14\" casing and cement same inplace.", "hpht": "0", "md": "2574", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "48", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "Retrieved Seat Protector and R/U casing handling equipment. M/U 14\" shoetrack and RIH 14\" casing to 854 m. ", "tightWell": "0", "tvd": "2442", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-22T10:00:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "33", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" }, { "dTim": "2013-04-22T21:00:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Active pit", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" } ]
[]
[]
[ { "comments": "Serviced and inspected drilling equipment and deisolated same.", "dTimEnd": "2013-04-22T00:30:00+02:00", "dTimStart": "2013-04-22T00:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Made up seat protector retrival tool and jet sub. RIH seat protector retrival tool to 137 m. Washed down from 137 m to 142 m with 2860 lpm, 54 bar. Engaged seat protector with 3 MT and 0.5 left hand turn.", "dTimEnd": "2013-04-22T02:30:00+02:00", "dTimStart": "2013-04-22T00:30:00+02:00", "md": "142", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "POOH with seat protector and dressed well head with 2770 lpm, 51 bar. Layed out seat protector and running tool.", "dTimEnd": "2013-04-22T04:00:00+02:00", "dTimStart": "2013-04-22T02:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- bop/wellhead equipment", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. R/U casing handling equipment", "dTimEnd": "2013-04-22T06:00:00+02:00", "dTimStart": "2013-04-22T04:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U casing handling equipment.", "dTimEnd": "2013-04-22T09:00:00+02:00", "dTimStart": "2013-04-22T06:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Held TBT. P/U 14\" float shoe and installed bypass baffle. P/U and M/U Intermmediate and landing collar 14\" casing joints. Tested float and RIH shoetrack to 33 m.", "dTimEnd": "2013-04-22T12:00:00+02:00", "dTimStart": "2013-04-22T09:00:00+02:00", "md": "33", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH 14\" 169.65 kg/m csg from 33 m to 327 m filling every joint with 1.42 sg OBM. Average running speed 6 jts./hr.", "dTimEnd": "2013-04-22T18:00:00+02:00", "dTimStart": "2013-04-22T12:00:00+02:00", "md": "327", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH 14\" 169.65 kg/m csg from 327 m to 854 m filling every joint with 1.42 sg OBM. Average running speed 8 jts./hr.", "dTimEnd": "2013-04-23T00:00:00+02:00", "dTimStart": "2013-04-22T18:00:00+02:00", "md": "854", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_24
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-23T00:00:00+02:00
2013-04-24T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "17.4", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-24T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Run 14\" casing to setting depth at 2570 m. Cement casing inplace, set seal assembly and wear bushing.", "hpht": "0", "md": "2574", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "49", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "RIH 14\" 169.65 kg/m casing from 901 m to 2133 m.", "tightWell": "0", "tvd": "2442", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-23T12:00:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9.5" }, { "dTim": "2013-04-23T04:30:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9" } ]
[]
[]
[ { "comments": "RIH 14\" 169.65 kg/m csg from 854 m to 901 m filling every joint with 1.42 sg OBM. \nLowered TDS to 3 m above rig floor, tilted bails forward to pick up 14\" 169.65 kg/m casing joint. When tilting forward a bolt on one out of four U-clamps sheared off. No personale in the area. Potential 0.12kg*4m*9.81=5J.", "dTimEnd": "2013-04-23T01:00:00+02:00", "dTimStart": "2013-04-23T00:00:00+02:00", "md": "901", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Isolated drilling equipment replaced broken U-clamp and inspected remaining three U-clamps. No wear or damage observed.", "dTimEnd": "2013-04-23T02:30:00+02:00", "dTimStart": "2013-04-23T01:00:00+02:00", "md": "901", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH 14\" 169.65 kg/m csg from 901 m to 953 m filling every joint with 1.42 sg OBM. Average running speed 6 jts./hr. \nObserved link arms pushing against U-clamp bolts on bails when using link tilt drill function.", "dTimEnd": "2013-04-23T03:00:00+02:00", "dTimStart": "2013-04-23T02:30:00+02:00", "md": "935", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Isolated drilling equipment and inspected same.\nEvaluated situation and formulized plan forward to only use link tilt retract function, thereby eliminating the pushing action on the bails. \n", "dTimEnd": "2013-04-23T04:00:00+02:00", "dTimStart": "2013-04-23T03:00:00+02:00", "md": "935", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH 14\" 169.65 kg/m csg from 935 m to 1057 m filling every joint with 1.42 sg OBM. Average running speed 6 jts./hr.", "dTimEnd": "2013-04-23T06:00:00+02:00", "dTimStart": "2013-04-23T04:00:00+02:00", "md": "1057", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH 14\" 169.65 kg/m csg from 1057 m to 1247 m filling every joint with 1.42 sg OBM. Average running speed 6 jts./hr. \nObserved leaking hose power tong.", "dTimEnd": "2013-04-23T09:00:00+02:00", "dTimStart": "2013-04-23T06:00:00+02:00", "md": "1247", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed out leaking hydraulic hose and connections on power tong.", "dTimEnd": "2013-04-23T10:00:00+02:00", "dTimStart": "2013-04-23T09:00:00+02:00", "md": "1247", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH 14\" 169.65 kg/m csg from 1247 m to 1348 m filling every joint with 1.42 sg OBM. Average running speed 6 jts./hr. \nEngaged fill up and circulation tool [FAC]. Broke circulation with 200 lpm, 10 bar. Staged up pumps in 100 lpm incriments to 1000 lpm, 14,7 bar.\nDis-engaged FAC. Observed connection on pack-off backed out.", "dTimEnd": "2013-04-23T12:30:00+02:00", "dTimStart": "2013-04-23T10:00:00+02:00", "md": "1348", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Made up connection on pack-off. Checked and re-tightent allen screw lock keys securing pack-off on FAC.", "dTimEnd": "2013-04-23T13:00:00+02:00", "dTimStart": "2013-04-23T12:30:00+02:00", "md": "1348", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH 14\" 169.65 kg/m csg from 1348 m to 1527 m filling every joint with 1.42 sg OBM. Average running speed 7 jts./hr. \nUnable to function power tong stabbing guide due to broken fitting on hydraulic hose.", "dTimEnd": "2013-04-23T15:30:00+02:00", "dTimStart": "2013-04-23T13:00:00+02:00", "md": "1527", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Removed hydraulic hose on stabbing guide and blanked off fitting on power tong.", "dTimEnd": "2013-04-23T16:00:00+02:00", "dTimStart": "2013-04-23T15:30:00+02:00", "md": "1527", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "RIH 14\" 169.65 kg/m csg from 1527 m to 2133 m filling every joint with 1.42 sg OBM. Average running speed 8 jts./hr.", "dTimEnd": "2013-04-24T00:00:00+02:00", "dTimStart": "2013-04-23T16:00:00+02:00", "md": "2133", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" } ]
[]
15_9_F_11_T2_2013_04_25
NO 15/9-F-11
NO 15/9-F-11 T2
name
2013-04-24T00:00:00+02:00
2013-04-25T00:00:00+02:00
normal
2018-05-03T13:51:29+02:00
{ "name": "15/9-F-11", "namingSystem": "NPD code" }
[ { "name": "15/9-F-11 T2", "namingSystem": "NPD code" }, { "name": "7078", "namingSystem": "NPD number" } ]
[ { "dTimSpud": "2013-03-07T17:30:00+01:00", "dateDrillComplete": "2013-05-09", "daysBehind": "15.6", "operator": "Statoil", "rigAlias": [ { "name": "MÆRSK INSPIRER", "namingSystem": "NPD Name" }, { "name": "369304", "namingSystem": "NPD code" } ] } ]
[ { "avgPresBH": null, "avgTempBH": null, "dTim": "2013-04-25T00:00:00+02:00", "dTimDiaHoleStart": "2013-04-13T12:30:00+02:00", "diaHole": "17.5", "diaPilot": null, "distDrill": "-999.99", "elevKelly": "54.9", "fixedRig": "false", "forecast24Hr": "Set and test seal assembly. Release hanger running tool, POOH and L/O same. RIH wearbushing and test BOPs.", "hpht": "0", "md": "2574", "mdCsgLast": "1357.7", "mdDiaHoleStart": "1368", "mdKickoff": null, "mdPlanned": "-999.99", "mdPlugTop": null, "mdStrengthForm": "1358", "presTestType": "formation integrity test", "reportNo": "50", "ropCurrent": "-999.99", "strengthForm": "1.55", "sum24Hr": "RIH and landed 14\" casing, shoe at 2570.68 m. Circulated 1.5 B/U and cemented 14\" casing inplace. \n\n", "tightWell": "0", "tvd": "2442", "tvdCsgLast": "1334", "tvdStrengthForm": "1334", "waterDepth": "91", "wellheadElevation": "138.9" } ]
[ { "dTim": "2013-04-24T14:00:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9.5" }, { "dTim": "2013-04-24T04:00:00+02:00", "density": "1.42", "filterCakeLtlp": null, "filtrateLtlp": null, "locationSample": "Flowline", "md": "2574", "mudClass": "oil based", "presBopRating": "345", "pv": "34", "tempHthp": "120", "type": "Enviromul Yellow", "visFunnel": "-999.99", "yp": "9.5" } ]
[]
[]
[ { "comments": "RIH 14\" 169.65 kg/m csg from 2133 m to 2424 m filling every joint with 1.42 sg OBM.Recorded Up/Dw weight 430/320 MT. Average running speed 8 jts./hr.", "dTimEnd": "2013-04-24T03:30:00+02:00", "dTimStart": "2013-04-24T00:00:00+02:00", "md": "2424", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Changed to 5 1/2\" handling equipment.", "dTimEnd": "2013-04-24T05:00:00+02:00", "dTimStart": "2013-04-24T03:30:00+02:00", "md": "2424", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "P/U and M/U 14\" casing hanger.\nAttempted to pick up 14\" casing hanger and RIH. Observed draw work drum pay out.", "dTimEnd": "2013-04-24T06:00:00+02:00", "dTimStart": "2013-04-24T05:00:00+02:00", "md": "2424", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Troubleshoot drawwork failure.\n\nMeanwhile: \nRemoved auto slips and lowered 14\" casing hanger below rotary in a controlled sequence, Up/Dw weight 430/320 MT. Installed master bushing and made up circulation swedge. Circulated with 200 lpm, 9 bar, 14\" casing shoe at 2433 m.", "dTimEnd": "2013-04-24T11:00:00+02:00", "dTimStart": "2013-04-24T06:00:00+02:00", "md": "2433", "phase": "fixed", "proprietaryCode": "interruption -- repair", "state": "ok", "stateDetailActivity": "equipment failure" }, { "comments": "Shot down pumps and flowchecked. R/D casing power tong, circulation swedge and surface lines.", "dTimEnd": "2013-04-24T12:30:00+02:00", "dTimStart": "2013-04-24T11:00:00+02:00", "md": "2433", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "RIH 14\" 169.65 kg/m casing on 5 1/2\" HWDP from 2433 m to 2516 m. Washed down from 2516 m to 2552 m with 500 lpm, 11 bar", "dTimEnd": "2013-04-24T14:00:00+02:00", "dTimStart": "2013-04-24T12:30:00+02:00", "md": "2552", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Recorded hole restriction at 2552 m. Worked and washed pass restriction with 1000 lpm, 16 bar, Up/Dw weight 440/318 MT.", "dTimEnd": "2013-04-24T15:30:00+02:00", "dTimStart": "2013-04-24T14:00:00+02:00", "md": "2552", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "M/U cement assembly and landed hanger at HOP 140.38 m. Set down 7 MT and marked pipe. Picked up and recorded 45 MT overpull, marked pipe. \nRotated landing string one right hand turn and verified stem free.", "dTimEnd": "2013-04-24T16:30:00+02:00", "dTimStart": "2013-04-24T15:30:00+02:00", "md": "2571", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "R/U cement hoses and circulated 1.5 B/U with 3000 lpm, 60 bar. No losses observed.", "dTimEnd": "2013-04-24T18:30:00+02:00", "dTimStart": "2013-04-24T16:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pumped 25 m3 of 1.75 SG spacer and dropped bottom dart. Mixed and pumped 24 m3 of 1.90 SG cement slurry, 600 lpm. Displaced the cement to the rig floor with 0.88 m3 and dropped top dart. \nZeroed stroke counters and displaced cement with 183 m3, 8262 strokes of 1.42 SG mud, 2970 lpm.\nObserved bottom plug shear after 7290 strokes.\n", "dTimEnd": "2013-04-24T21:00:00+02:00", "dTimStart": "2013-04-24T18:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Stepped down pumps to 500 lpm, FCP 31 bar and bumped top plug after 188 m3, 8480 strokes pumped. Pressured up t0 90 bar/10 min and eqaulized lines to cement unit.", "dTimEnd": "2013-04-24T21:30:00+02:00", "dTimStart": "2013-04-24T21:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- other", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Pressure tested casing to 340 bar/10 min, 2.2/2.2 m3 Pumped/Returned", "dTimEnd": "2013-04-24T23:00:00+02:00", "dTimStart": "2013-04-24T21:30:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" }, { "comments": "Slacked off weight and marked pipe. Picked up 45 MT overpull test, slacked of and rotated pipe 3.5 RH turns, Marked pipe and recorded 8.5\" travel. Sat seal assembly with 207 bar/10 min and picked up 45 MT.", "dTimEnd": "2013-04-25T00:00:00+02:00", "dTimStart": "2013-04-24T23:00:00+02:00", "md": "0", "phase": "fixed", "proprietaryCode": "drilling -- casing", "state": "ok", "stateDetailActivity": "success" } ]
[]